857 resultados para Waist-to-hip ratio


Relevância:

100.00% 100.00%

Publicador:

Resumo:

In the present thesis, questions of spectral tuning, the relation of spectral and thermal properties of visual pigments, and evolutionary adaptation to different light environments were addressed using a group of small crustaceans of the genus Mysis as a model. The study was based on microspectrophotometric measurements of visual pigment absorbance spectra, electrophysiological measurements of spectral sensitivities of dark-adapted eyes, and sequencing of the opsin gene retrieved through PCR. The spectral properties were related to the spectral transmission of the respective light environments, as well as to the phylogentic histories of the species. The photoactivation energy (Ea) was estimated from temperature effects on spectral sensitivity in the long-wavelength range, and calculations were made for optimal quantum catch and optimal signal-to-noise ratio in the different light environments. The opsin amino acid sequences of spectrally characterized individuals were compared to find candidate residues for spectral tuning. The general purpose was to clarify to what extent and on what time scale adaptive evolution has driven the functional properties of (mysid) visual pigments towards optimal performance in different light environments. An ultimate goal was to find the molecular mechanisms underlying the spectral tuning and to understand the balance between evolutionary adaptation and molecular constraints. The totally consistent segregation of absorption maxima (λmax) into (shorter-wavelength) marine and (longer-wavelength) freshwater populations suggests that truly adaptive evolution is involved in tuning the visual pigment for optimal performance, driven by selection for high absolute visual sensitivity. On the other hand, the similarity in λmax and opsin sequence between several populations of freshwater M. relicta in spectrally different lakes highlights the limits to adaptation set by evolutionary history and time. A strong inverse correlation between Ea and λmax was found among all visual pigments studied in these respects, including those of M. relicta and 10 species of vertebrate pigments, and this was used to infer thermal noise. The conceptual signal-to-noise ratios thus calculated for pigments with different λmax in the Baltic Sea and Lake Pääjärvi light environments supported the notion that spectral adaptation works towards maximizing the signal-to-noise ratio rather than quantum catch as such. Judged by the shape of absorbance spectra, the visual pigments of all populations of M. relicta and M. salemaai used exclusively the A2 chromophore (3, 4-dehydroretinal). A comparison of amino acid substitutions between M. relicta and M. salemaai indicated that mysid shrimps have a small number of readily available tuning sites to shift between a shorter - and a longer -wavelength opsin. However, phylogenetic history seems to have prevented marine M. relicta from converting back to the (presumably) ancestral opsin form, and thus the more recent reinvention of marine spectral sensitivity has been accomplished by some other novel mechanism, yet to be found

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A three-dimensional rigorous solution for determining thermal stresses in a finite solid cylinder due to a steady state axisymmetric temperature field over one of its end surfaces is given. Numerical results for a solid cylinder having a length to diameter ratio equal to one and subjected to a symmetric temperature variation over half the radius of the cylinder at the end surfaces are included. These results have been compared with the results of the approximate solution given by W. Nowacki.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A better understanding of vacuum arcs is desirable in many of today's 'big science' projects including linear colliders, fusion devices, and satellite systems. For the Compact Linear Collider (CLIC) design, radio-frequency (RF) breakdowns occurring in accelerating cavities influence efficiency optimisation and cost reduction issues. Studying vacuum arcs both theoretically as well as experimentally under well-defined and reproducible direct-current (DC) conditions is the first step towards exploring RF breakdowns. In this thesis, we have studied Cu DC vacuum arcs with a combination of experiments, a particle-in-cell (PIC) model of the arc plasma, and molecular dynamics (MD) simulations of the subsequent surface damaging mechanism. We have also developed the 2D Arc-PIC code and the physics model incorporated in it, especially for the purpose of modelling the plasma initiation in vacuum arcs. Assuming the presence of a field emitter at the cathode initially, we have identified the conditions for plasma formation and have studied the transitions from field emission stage to a fully developed arc. The 'footing' of the plasma is the cathode spot that supplies the arc continuously with particles; the high-density core of the plasma is located above this cathode spot. Our results have shown that once an arc plasma is initiated, and as long as energy is available, the arc is self-maintaining due to the plasma sheath that ensures enhanced field emission and sputtering. The plasma model can already give an estimate on how the time-to-breakdown changes with the neutral evaporation rate, which is yet to be determined by atomistic simulations. Due to the non-linearity of the problem, we have also performed a code-to-code comparison. The reproducibility of plasma behaviour and time-to-breakdown with independent codes increased confidence in the results presented here. Our MD simulations identified high-flux, high-energy ion bombardment as a possible mechanism forming the early-stage surface damage in vacuum arcs. In this mechanism, sputtering occurs mostly in clusters, as a consequence of overlapping heat spikes. Different-sized experimental and simulated craters were found to be self-similar with a crater depth-to-width ratio of about 0.23 (sim) - 0.26 (exp). Experiments, which we carried out to investigate the energy dependence of DC breakdown properties, point at an intrinsic connection between DC and RF scaling laws and suggest the possibility of accumulative effects influencing the field enhancement factor.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We address the problem of detecting cells in biological images. The problem is important in many automated image analysis applications. We identify the problem as one of clustering and formulate it within the framework of robust estimation using loss functions. We show how suitable loss functions may be chosen based on a priori knowledge of the noise distribution. Specifically, in the context of biological images, since the measurement noise is not Gaussian, quadratic loss functions yield suboptimal results. We show that by incorporating the Huber loss function, cells can be detected robustly and accurately. To initialize the algorithm, we also propose a seed selection approach. Simulation results show that Huber loss exhibits better performance compared with some standard loss functions. We also provide experimental results on confocal images of yeast cells. The proposed technique exhibits good detection performance even when the signal-to-noise ratio is low.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We address the problem of speech enhancement using a risk- estimation approach. In particular, we propose the use the Stein’s unbiased risk estimator (SURE) for solving the problem. The need for a suitable finite-sample risk estimator arises because the actual risks invariably depend on the unknown ground truth. We consider the popular mean-squared error (MSE) criterion first, and then compare it against the perceptually-motivated Itakura-Saito (IS) distortion, by deriving unbiased estimators of the corresponding risks. We use a generalized SURE (GSURE) development, recently proposed by Eldar for MSE. We consider dependent observation models from the exponential family with an additive noise model,and derive an unbiased estimator for the risk corresponding to the IS distortion, which is non-quadratic. This serves to address the speech enhancement problem in a more general setting. Experimental results illustrate that the IS metric is efficient in suppressing musical noise, which affects the MSE-enhanced speech. However, in terms of global signal-to-noise ratio (SNR), the minimum MSE solution gives better results.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This work aims at asymptotically accurate dimensional reduction of non-linear multi-functional film-fabric laminates having specific application in design of envelopes for High Altitude Airships (HAA). The film-fabric laminate for airship envelope consists of a woven fabric core coated with thin films on each face. These films provide UV protection and Helium leakage prevention, while the core provides required structural strength. This problem is both geometrically and materially non-linear. To incorporate the geometric non-linearity, generalized warping functions are used and finite deformations are allowed. The material non-linearity is handled by using hyper-elastic material models for each layer. The development begins with three-dimensional (3-D) nonlinear elasticity and mathematically splits the analysis into a one-dimensional through-the-thickness analysis and a two-dimensional (2-D) plate analysis. The through-the-thickness analysis provides the 2-D constitutive law which is then given as an input to the 2-D reference surface analysis. The dimensional reduction is carried out using Variational Asymptotic Method (VAM) for moderate strains and very small thickness-to-wavelength ratio. It features the identification and utilization of additional small parameters such as ratio of thicknesses and stiffness coefficients of core and films. Closed form analytical expressions for warping functions and 2-D constitutive law of the film-fabric laminate are obtained.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Single scan longitudinal relaxation measurement experiments enable rapid estimation of the spin-lattice relaxation time (T-1) as the time series of spin relaxation is encoded spatially in the sample at different slices resulting in an order of magnitude saving in time. We consider here a single scan inversion recovery pulse sequence that incorporates a gradient echo sequence. The proposed pulse sequence provides spectra with significantly enhanced signal to noise ratio leading to an accurate estimation of T-1 values. The method is applicable for measuring a range of T-1 values, thus indicating the possibility of routine use of the method for several systems. A comparative study of different single scan methods currently available is presented, and the advantage of the proposed sequence is highlighted. The possibility of the use of the method for the study of cross-correlation effects for the case of fluorine in a single shot is also demonstrated. Copyright (C) 2015 John Wiley & Sons, Ltd.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Single scan longitudinal relaxation measurement experiments enable rapid estimation of the spin-lattice relaxation time (T-1) as the time series of spin relaxation is encoded spatially in the sample at different slices resulting in an order of magnitude saving in time. We consider here a single scan inversion recovery pulse sequence that incorporates a gradient echo sequence. The proposed pulse sequence provides spectra with significantly enhanced signal to noise ratio leading to an accurate estimation of T-1 values. The method is applicable for measuring a range of T-1 values, thus indicating the possibility of routine use of the method for several systems. A comparative study of different single scan methods currently available is presented, and the advantage of the proposed sequence is highlighted. The possibility of the use of the method for the study of cross-correlation effects for the case of fluorine in a single shot is also demonstrated. Copyright (C) 2015 John Wiley & Sons, Ltd.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Two different spatial levels are involved concerning damage accumulation to eventual failure. nucleation and growth rates of microdamage nN* and V*. It is found that the trans-scale length ratio c*/L does not directly affect the process. Instead, two independent dimensionless numbers: the trans-scale one * * ( V*)including the * **5 * N c V including mesoscopic parameters only, play the key role in the process of damage accumulation to failure. The above implies that there are three time scales involved in the process: the macroscopic imposed time scale tim = /a and two meso-scopic time scales, nucleation and growth of damage, (* *4) N N t =1 n c and tV=c*/V*. Clearly, the dimensionless number De*=tV/tim refers to the ratio of microdamage growth time scale over the macroscopically imposed time scale. So, analogous to the definition of Deborah number as the ratio of relaxation time over external one in rheology. Let De be the imposed Deborah number while De represents the competition and coupling between the microdamage growth and the macroscopically imposed wave loading. In stress-wave induced tensile failure (spallation) De* < 1, this means that microdamage has enough time to grow during the macroscopic wave loading. Thus, the microdamage growth appears to be the predominate mechanism governing the failure. Moreover, the dimensionless number D* = tV/tN characterizes the ratio of two intrinsic mesoscopic time scales: growth over nucleation. Similarly let D be the “intrinsic Deborah number”. Both time scales are relevant to intrinsic relaxation rather than imposed one. Furthermore, the intrinsic Deborah number D* implies a certain characteristic damage. In particular, it is derived that D* is a proper indicator of macroscopic critical damage to damage localization, like D* ∼ (10–3~10–2) in spallation. More importantly, we found that this small intrinsic Deborah number D* indicates the energy partition of microdamage dissipation over bulk plastic work. This explains why spallation can not be formulated by macroscopic energy criterion and must be treated by multi-scale analysis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A doença Inflamatória Intestinal (DII) é uma desordem caracterizada pela inflamação crônica do trato gastrointestinal. Os dois principais tipos de DII são a Retocolite Ulcerativa (RCU) e a Doença de Crohn (DC) e ambas cursam com importantes alterações no estado nutricional (EN). O objetivo deste estudo foi identificar as diferenças na composição corporal entre pacientes com DC, RCU e indivíduos saudáveis, além de comparar o estado nutricional dos três grupos de pacientes, ajustando para fatores que podem interferir no EN, como o uso atual de corticosteróides, a atividade física, a atividade de doença, a idade e o sexo. Foi realizado um estudo transversal que incluiu 101 pacientes com DII (50 com DC e 51 com RCU) e 35 indivíduos saudáveis, selecionados no Ambulatório do Hospital Universitário Pedro Ernesto (HUPE) da Universidade do Estado do Rio de Janeiro (UERJ). Foram colhidas informações sócio-demográficas e pessoais, tais como: prática de atividade física, tabagismo, doenças pregressas e procedimentos cirúrgicos prévios. Outras informações necessárias à pesquisa foram coletadas em prontuário médico. A avaliação antropométrica foi realizada por meio das seguintes medidas: peso corporal; altura; circunferências do braço, da cintura (CC) e do quadril; dobras cutâneas do tríceps, subescápula, supra-ilíaca e da coxa; e circunferência muscular do braço (CMB). A análise da composição corporal foi realizada por meio da bioimpedância elétrica (BIA), utilizando-se o aparelho Biodynamics modelo 450. As variáveis laboratoriais analisadas foram: glicose, hemograma completo, perfil lipídico, proteínas totais, albumina, globulina, velocidade de hemossedimentação e proteína C reativa. O peso, o índice de massa corporal, a CC e o percentual de gordura corporal calculado a partir da aferição das dobras cutâneas, foram menores nos pacientes com DC, quando comparados aos indivíduos saudáveis e/ou aos pacientes com RCU. A CMB foi menor nos pacientes com DC e RCU quando comparados aos indivíduos saudáveis, porém sem apresentar diferenças entre os dois grupos de pacientes. Por BIA, verificou-se que os pacientes com DC apresentaram valores de massa magra, massa celular corpórea, massa extracelular, água corporal total e água extracelular menores quando comparados aos indivíduos saudáveis. Os níveis séricos de colesterol total, proteínas totais e albumina, e a contagem total de hemácias foram menores nos indivíduos com DC quando comparados aos indivíduos do grupo controle e/ou aos indivíduos do grupo da RCU. Os pacientes com RCU exibem composição corporal semelhante à da população saudável. Em contraposição, os pacientes com DC apresentam EN amplamente comprometido com depleção de gordura corporal e massa magra em relação aos demais indivíduos

Relevância:

100.00% 100.00%

Publicador:

Resumo:

O período pós-parto pode ser considerado a fase em que a mulher está exposta a retenção de massa corporal (MC) e desenvolvimento da obesidade. Na maioria das situações valorizam-se mais a perda de MC e pouco se conhece a respeito dos componentes que estão sendo mobilizados. Desta forma, há interesse de se validar técnicas acessíveis, como a impedância bioelétrica (BIA), que possam ser aplicadas no acompanhamento nutricional destas mulheres. O presente estudo teve como objetivo validar diferentes modelos de impedância bioelétrica (BIA) para a determinação da composição corporal em mulheres pós-parto tendo como ?padrão ouro? a técnica de absorciometria de dupla energia de raio X(DXA). A amostra foi composta por 46 mulheres no período pós-parto com idade acima de 18anos, inicialmente recrutadas e convidadas a participar da pesquisa, logo após o parto, para posteriormente serem avaliadas. A composição corporal (CC) foi mensurada através de três aparelhos distintos de BIA: RJL , BIO e Tanita e pela DXA. Os componentes101450BC 533corporais medidos foram: massa livre de gordura (MLG), massa gorda (MG) e percentual degordura corporal (%GC). Na análise estatística foram calculadas as médias e desvio-padrãodas variáveis contínuas. A concordância entre os componentes corporais determinados pelaDXA e cada BIA foi avaliada pelo método de Bland & Altman e pelo coeficiente decorrelação de concordância (CCC). Para comparação de médias das variáveis obtidas por BIAe DXA para cada faixa de índice de massa corporal (IMC), foi aplicada a ANOVA e oadotado o teste post-hoc de Tukey. O nível de significância adotado foi de 95% (p=0,05). Amédia ( desvio padrão) de idade foi de 25,5 4,6 anos, a MC de 73,6 12,2kg, o IMC de28,7 4,3kg/m, a MG de 29,87,4kg, a MLG de 43,25,7kg e o %GC de 41,84,3%,obtidos pelo DXA. Ao comparar-se os resultados dos diferentes equipamentos com o método padrão-ouro, verificou-se que houve diferença significativa entre a DXA e as BIA para todos componentes corporais, com exceção da MG fornecida pelo RJL (27,1Kg) e TAN (27,1Kg)em relação à DXA (29,8Kg). Os resultados mostraram haver uma boa reprodutibilidade emrelação aos aparelhos de BIA TAN (r=0,74; r=0,90) e RJL (r=0,78; r=0,89) para MLG e MG.Verificou-se que os equipamentos de BIA TAN e RJL forneceram estimativas semelhantes em relação à MLG, MG e %GC. Em relação aos valores da DXA o equipamento que mais se aproximou foi a TAN e o RJL quando avaliada a MG considerando todas as mulheres, mas quando estratificadas segundo o IMC, a análise foi mais acurada em mulheres obesas.Entretanto, a concordância não foi satisfatória entre os componentes corporais fornecidos pelas BIA em relação à DXA. As BIAs avaliadas no presente estudo subestimaram o %GC e superestimaram a MLG para esse grupo de mulheres no período pós-parto. Conclui-se que as BIA avaliadas não são recomendadas para avaliação da CC neste grupo de mulheres no período pós-parto.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A Doença Inflamatória Intestinal (DII) é uma desordem caracterizada pela inflamação difusa do trato gastrointestinal. Os dois principais tipos de DII são a Retocolite Ulcerativa (RCU) e a Doença de Crohn (DC) e ambas cursam com alterações no estado nutricional (EN). O objetivo deste estudo foi comparar a composição corporal, obtida por meio de diferentes métodos, em pacientes com DC e RCU em atendimento ambulatorial, avaliando possíveis diferenças nos grupos de doentes entre si e quando comparados a indivíduos saudáveis. Foi realizado um estudo transversal incluindo 101 pacientes com DII, sendo 50 com DC (GDC) e 51 com RCU (GRCU), além de 35 indivíduos saudáveis (GCON), selecionados no Ambulatório do Hospital Universitário Pedro Ernesto (HUPE) da Universidade do Estado do Rio de Janeiro (UERJ). Informações sócio-demográficas e pessoais, como prática de exercício físico, tabagismo, doenças pregressas e procedimentos cirúrgicos prévios foram coletadas. A avaliação antropométrica consistiu de: peso; altura; circunferências do braço, da cintura e do quadril; circunferência muscular do braço (CMB) e pregas cutâneas do tríceps, bíceps, peitoral, axilar, subescapular, suprailíaca, supraespinhal, abdominal, perna e coxa. O percentual de gordura corporal (% GC) foi estimado a partir de equações que utilizam o somatório de pregas cutâneas e por meio de bioimpedância elétrica (BIA). Para estimar o percentual de gordura subcutânea foi utilizado o somatório de dez dobras. As variáveis laboratoriais analisadas foram: hemograma completo, proteínas totais, albumina, globulina, velocidade de hemossedimentação e proteína C reativa. As análises estatísticas foram realizadas utilizando-se o software STATA versão 10.0. A classificação do EN, por meio do índice de massa corporal (IMC), evidenciou baixa prevalência de desnutrição nos três grupos avaliados. Ao analisar diretamente as medidas antropométricas de peso e IMC, observou-se que os pacientes com DC apresentaram valores significativamente menores do que os indivíduos do grupo controle. A avaliação da CMB mostrou que os pacientes do GDC e GRCU apresentaram depleção de massa magra em comparação aos indivíduos do GCON, porém sem apresentar diferenças entre os dois grupos de pacientes com DII. Em relação ao %GC obtido por BIA não foram verificadas diferenças entre os três grupos de estudo. Ao se verificar o %GC com a utilização das fórmulas de Peterson, Durnin & Womersley e Jackson & Pollock (que utiliza o somatório de três dobras) observou-se que os pacientes com DC apresentaram tecido adiposo significativamente depletado em relação aos indivíduos do GCON e do GRCU. Ao compararmos os %GC obtidos por diferentes métodos de estimativa, observou-se que as equações de Jackson & Pollock (que utilizam o somatório de três e sete dobras) apresentaram resultados significativamente menores quando comparados aos das equações de Peterson e Durnin & Womersley, nos dois grupos de pacientes. Os níveis séricos de proteínas totais e albumina, e a contagem total de hemácias foram menores nos indivíduos com DC quando comparados aos indivíduos do grupo controle e/ou aos indivíduos do grupo com RCU. Os pacientes com DC apresentaram comprometimento importante do EN em comparação aos pacientes com RCU e, notadamente, em relação aos indivíduos saudáveis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Brevetoxin uptake was analyzed in 2 common planktivorous fish that are likely foodweb vectors for dolphin mortality events associated with brevetoxin-producing red tides. Fish were exposed to brevetoxin-producing Karenia brevis for 10 h under conditions previously reported to produce optimal uptake of toxin in blood after oral exposure. Striped mullet Mugil cephalus were exposed to a low dose of brevetoxin, and uptake and depuration by specific organs were evaluated over a 2 mo period. Atlantic menhaden Brevoortia tyrannus specimens were used to characterize a higher brevetoxin dose uptake into whole body components and evaluate depuration over 1 mo. We found a high uptake of toxin by menhaden, with a body to water ratio of 57 after a 10 h exposure and a slow elimination with a half life (t1/2) of 24 d. Elimination occurred rapidly from the intestine (t1/2 < 1 wk) and muscle (t1/2 ≈ 1 wk) compartments and redistributed to liver which continued to accumulate body stores of toxin for 4 wk. The accumulation and elimination characteristics of the vectoring capacity of these 2 fish species are interpreted in relation to data from the Florida Panhandle dolphin mortality event of 2004. We show that due to slow elimination rate of brevetoxin in planktivorous fish, brevetoxin-related dolphin mortality events may occur without evidence of a concurrent harmful algal bloom event.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

mark Unsteady ejectors can be driven by a wide range of driver jets. These vary from pulse detonation engines, which typically have a long gap between each slug of fluid exiting the detonation tube (mark-space ratios in the range 0.1-0.2) to the exit of a pulsejet where the mean mass flow rate leads to a much shorter gap between slugs (mark-space ratios in the range 2-3). The aim of this paper is to investigate the effect of mark-space ratio on the thrust augmentation of an unsteady ejector. Experimental testing was undertaken using a driver jet with a sinusoidal exit velocity profile. The mean value, amplitude and frequency of the velocity profile could be changed allowing the length to diameter ratio of the fluid slugs L/D and the mark-space ratio (the ratio of slug length to the spacing between slugs) L/S to be varied. The setup allowed L/S of the jet to vary from 0.8 to 2.3, while the L/D ratio of the slugs could take any values between 3.5 and 7.5. This paper shows that as the mark-space ratio of the driver jet is increased the thrust augmentation drops. Across the range of mark-space ratios tested, there is shown to be a drop in thrust augmentation of 0.1. The physical cause of this reduction in thrust augmentation is shown to be a decrease in the percentage time over which the ejector entrains ambient fluid. This is the direct result ofthe space between consecutive slugs in the driver jet decreasing. The one dimensional model reported in Heffer et al. [1] is extended to include the effect of varying L/S and is shown to accurately capture the experimentally measured behavior ofthe ejector. Copyright © 2010 by the American Institute of Aeronautics and Astronautics, Inc.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Meat to water ratio used for washing was 1:3 for oil sardine and mackerel; but for pink perch and croaker, it was 1:2. Again the washing process was repeated three times for oil sardine and mackerel; but two times for pink perch and croaker. The washed meat was mixed with 2.5% NaC1 and set at +5°C and +40°C for 1, 2 and 3hrs. The gel strength and expressible water content was measured. Basing on this study, setting temperature at +40°C was selected and with respect to time 1hr for sardine and mackerel and 3hrs for pink perch and croaker was selected.