974 resultados para Volume of fluid (VOF)


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Agitating liquids in unbaffled stirred tank leads to the formation of a vortex in the region of the impeller shaft when operating in the turbulent flow regime. A numerical model is presented here that captures such a vortex. The volume of fluid model, a multiphase flow model was employed in conjunction with a multiple reference frame model and the shear stress turbulence model. The dimensions of the tank considered here, were 0.585 m for the liquid depth and tank diameter with a 0.2925 m diameter impeller at a height of 0.2925 m. The impeller considered was an eight-bladed paddle type agitator that was rotating with an angular velocity of 7.54 rad s (72 rpm) giving a Reynolds number of 10 and Froude number of 0.043. Preliminary results of a second investigation into the effect of liquid phase properties on the vortex formed are also presented. © 2006 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND AND OBJECTIVE: Key factors of Fast Track (FT) programs are fluid restriction and epidural analgesia (EDA). We aimed to challenge the preconception that the combination of fluid restriction and EDA might induce hypotension and renal dysfunction. METHODS: A recent randomized trial (NCT00556790) showed reduced complications after colectomy in FT patients compared with standard care (SC). Patients with an effective EDA were compared with regard to hemodynamics and renal function. RESULTS: 61/76 FT patients and 59/75 patients in the SC group had an effective EDA. Both groups were comparable regarding demographics and surgery-related characteristics. FT patients received significantly less i.v. fluids intraoperatively (1900 mL [range 1100-4100] versus 2900 mL [1600-5900], P < 0.0001) and postoperatively (700 mL [400-1500] versus 2300 mL [1800-3800], P < 0.0001). Intraoperatively, 30 FT compared with 19 SC patients needed colloids or vasopressors, but this was statistically not significant (P = 0.066). Postoperative requirements were low in both groups (3 versus 5 patients; P = 0.487). Pre- and postoperative values for creatinine, hematocrit, sodium, and potassium were similar, and no patient developed renal dysfunction in either group. Only one of 82 patients having an EDA without a bladder catheter had urinary retention. Overall, FT patients had fewer postoperative complications (6 versus 20 patients; P = 0.002) and a shorter median hospital stay (5 [2-30] versus 9 d [6-30]; P< 0.0001) compared with the SC group. CONCLUSIONS: Fluid restriction and EDA in FT programs are not associated with clinically relevant hemodynamic instability or renal dysfunction.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: The arterial pulse pressure variation induced by mechanical ventilation (Delta PP) has been shown to be a predictor of fluid responsiveness. Until now, Delta PP has had to be calculated offline (from a computer recording or a paper printing of the arterial pressure curve), or to be derived from specific cardiac output monitors, limiting the widespread use of this parameter. Recently, a method has been developed for the automatic calculation and real-time monitoring of Delta PP using standard bedside monitors. Whether this method is to predict reliable predictor of fluid responsiveness remains to be determined. METHODS: We conducted a prospective clinical study in 59 mechanically ventilated patients in the postoperative period of cardiac surgery. Patients studied were considered at low risk for complications related to fluid administration (pulmonary artery occlusion pressure <20 mm Hg, left ventricular ejection fraction >= 40%). All patients were instrumented with an arterial line and a pulmonary artery catheter. Cardiac filling pressures and cardiac output were measured before and after intravascular fluid administration (20 mL/kg of lactated Ringer`s solution over 20 min), whereas Delta PP was automatically calculated and continuously monitored. RESULTS: Fluid administration increased cardiac output by at least 15% in 39 patients (66% = responders). Before fluid administration, responders and nonresponders were comparable with regard to right atrial and pulmonary artery occlusion pressures. In contrast, Delta PP was significantly greater in responders than in nonresponders, (17% +/- 3% vs 9% +/- 2%, P < 0.001). The Delta PP cut-off value of 12% allowed identification of responders with a sensitivity of 97% and a specificity of 95%. CONCLUSION: Automatic real-time monitoring of Delta PP is possible using a standard bedside rnonitor and was found to be a reliable method to predict fluid responsiveness after cardiac surgery. Additional studies are needed to determine if this technique can be used to avoid the complications of fluid administration in high-risk patients.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: Different hemodynamic parameters including static indicators of cardiac preload as right ventricular end-diastolic volume index (RVEDVI) and dynamic parameters as pulse pressure variation (PPV) have been used in the decision-making process regarding volume expansion in critically ill patients. The objective of this study was to compare fluid resuscitation guided by either PPV or RVEDVI after experimentally induced hemorrhagic shock. Methods: Twenty-six anesthetized and mechanically ventilated pigs were allocated into control (group I), PPV (group II), or RVEDVI (group III) group. Hemorrhagic shock was induced by blood withdrawal to target mean arterial pressure of 40 mm Hg, maintained for 60 minutes. Parameters were measured at baseline, time of shock, 60 minutes after shock, immediately after resuscitation with hydroxyethyl starch 6% (130/0.4), 1 hour and 2 hours thereafter. The endpoint of fluid resuscitation was determined as the baseline values of PPV and RVEDVI. Statistical analysis of data was based on analysis of variance for repeated measures followed by the Bonferroni test (p < 0.05). Results: Volume and time to resuscitation were higher in group III than in group II (group III = 1,305 +/- 331 mL and group II = 965 +/- 245 mL, p < 0.05; and group III = 24.8 +/- 4.7 minutes and group II = 8.8 +/- 1.3 minutes, p < 0.05, respectively). All static and dynamic parameters and biomarkers of tissue oxygenation were affected by hemorrhagic shock and nearly all parameters were restored after resuscitation in both groups. Conclusion: In the proposed model of hemorrhagic shock, resuscitation to the established endpoints was achieved within a smaller amount of time and with less volume when guided by PPV than when guided by pulmonary artery catheter-derived RVEDVI.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

RESUME : Objectif: Le glioblastome multiforme (GBM) est la tumeur cérébrale maligne la plus agressive qui conduit au décès de la majorité des patients moins d'une année après le diagnostic. La plupart des agents chimiothérapeutiques actuellement disponibles ne traversent pas la barrière hémato¬encéphalique et ne peuvent par conséquent pas être utilisés pour ce type de tumeur. Le Temozolomide (TMZ) est un nouvel agent alkylant récemment développé pour le traitement des gliomes malins. A ce jour, très peu d'informations sont disponibles sur la pénétration intra-cérébrale de cet agent. Au cours d'une étude pilote de phase II menée auprès de 64 patients atteints de GBM, l'administration précoce de TMZ combinée à une radiothérapie standard (RT) afin d'intervenir au plus tôt dans l'évolution de la maladie, a permis de prolonger la survie de ces patients, résultat qui pu être confirmé par la suite lors de l'étude randomisée de phase III. L'objectif de cette étude a été de déterminer les paramètres pharmacocinétique du TMZ dans le plasma et le liquide céphalo-rachidien (LCR), d'évaluer l'influence de certains facteurs individuels (âge, sexe, surface corporelle, fonction rénale/hépatique, co-médications, RT concomitante) sur ces différents paramètres, et enfin d'explorer la relation existant entre l'exposition au TMZ et certains marqueurs cliniques d'efficacité et de toxicité. Matériel et Méthode: Les concentrations de TMZ ont été mesurées par chromatographie liquide à haute performance (HPLC) dans le plasma et le LCR de 35 patients atteints de GBM nouvellement diagnostiqués (étude pilote) ou de gliomes malins en récidive (étude récidive). L'analyse pharmacocinétique de population a été réalisée à l'aide du programme NONMEM. L'exposition systémique et cérébrale, définie par les AUC (Area Under the time-concentration Curve) dans le plasma et le LCR, a été estimée pour chaque patient et corrélée à la toxicité, la survie ainsi que la survie sans progression tumorale. Résultats: Un modèle à 1 compartiment avec une cinétique d'absorption et de transfert Kplasma -> LCR de ordre a été retenu afin de décrire le profil pharmacocinétique du TMZ. Les valeurs moyennes de population ont été de 10 L/h pour la clairance, de 30.3 L pour le volume de distribution, de 2.1 h pour la 1/2 vie d'élimination, de 5.78 hE-1 pour la constante d'absorption, de 7.2 10E4 hE-1 pour Kplasma->LCR et de 0.76 hE-1 pour KLCR plasma. La surface corporelle a montré une influence significative sur la clairance et le volume de distribution, alors que le sexe influence la clairance uniquement. L'AUC mesurée dans le LCR représente ~20% de celle du plasma et une augmentation de 15% de Kplasma->LCR a été observée lors du traitement concomitant de radiochimiothérapie. Conclusions: Cette étude est la première analyse pharmacocinétique effectuée chez l'homme permettant de quantifier la pénétration intra-cérébrale du TMZ. Le rapport AUC LCR/AUC Plasma a été de 20%. Le degré d'exposition systémique et cérébral au TMZ ne semble pas être un meilleur facteur prédictif de la survie ou de la tolérance au produit que ne l'est la dose cumulée seule. ABSTRACT Purpose: Scarce information is available on the brain penetration of temozolomide (TMZ), although this novel methylating agent is mainly used for the treatment of ma¬lignant brain tumors. The purpose was to assess TNIZ phar¬macokinetics in plasma and cerebrospinal fluid (CSF) along with its inter-individual variability, to characterize covari¬ates and to explore relationships between systemic or cere¬bral drug exposure and clinical outcomes. Experimental Design: TMZ levels were measured by high-performance liquid chromatography in plasma and CSF samples from 35 patients with newly diagnosed or recurrent malignant gliomas. The population pharmacoki¬netic analysis was performed with nonlinear mixed-effect modeling software. Drug exposure, defined by the area un¬der the concentration-time curve (AUC) in plasma and CSF, was estimated for each patient and correlated with toxicity, survival, and progression-free survival. Results: A three-compartment model with first-order absorption and transfer rates between plasma and CSF described the data appropriately. Oral clearance was 10 liter/h; volume of distribution (VD), 30.3 liters; absorption constant rate, 5.8 hE-1; elimination half-time, 2.1 h; transfer rate from plasma to CSF (Kplasma->CSF), 7.2 x 10E-4hE-1 and the backwards rate, 0.76hE-1. Body surface area signifi¬cantly influenced both clearance and VD, and clearance was sex dependent. The AU CSF corresponded to 20% of the AUCplasma. A trend toward an increased K plasma->CSF of 15% was observed in case of concomitant radiochemo-therapy. No significant correlations between AUC in plasma or CSF and toxicity, survival, or progression-free survival were apparent after deduction of dose-effect. Conclusions: This is the first human pharmacokinetic study on TMZ to quantify CSF penetration. The AUC CSF/ AUC plasma ratio was 20%. Systemic or cerebral exposures are not better predictors than the cumulative dose alone for both efficacy and safety.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The main objective of this work is to analyze the importance of the gas-solid interface transfer of the kinetic energy of the turbulent motion on the accuracy of prediction of the fluid dynamic of Circulating Fluidized Bed (CFB) reactors. CFB reactors are used in a variety of industrial applications related to combustion, incineration and catalytic cracking. In this work a two-dimensional fluid dynamic model for gas-particle flow has been used to compute the porosity, the pressure, and the velocity fields of both phases in 2-D axisymmetrical cylindrical co-ordinates. The fluid dynamic model is based on the two fluid model approach in which both phases are considered to be continuous and fully interpenetrating. CFB processes are essentially turbulent. The model of effective stress on each phase is that of a Newtonian fluid, where the effective gas viscosity was calculated from the standard k-epsilon turbulence model and the transport coefficients of the particulate phase were calculated from the kinetic theory of granular flow (KTGF). This work shows that the turbulence transfer between the phases is very important for a better representation of the fluid dynamics of CFB reactors, especially for systems with internal recirculation and high gradients of particle concentration. Two systems with different characteristics were analyzed. The results were compared with experimental data available in the literature. The results were obtained by using a computer code developed by the authors. The finite volume method with collocated grid, the hybrid interpolation scheme, the false time step strategy and SIMPLEC (Semi-Implicit Method for Pressure Linked Equations - Consistent) algorithm were used to obtain the numerical solution.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The assessment of fluid volume in neonates by a noninvasive, inexpensive, and fast method can contribute significantly to increase the quality of neonatal care. The objective of the present study was to calibrate an acquisition system and software to estimate the bioelectrical impedance parameters obtained by a method of bioelectrical impedance spectroscopy based on step response and to develop specific equations for the neonatal population to determine body fluid compartments. Bioelectric impedance measurements were performed by a laboratory homemade instrument. The volumes were estimated in a clinical study on 30 full-term neonates at four different times during the first month of life. During the first 24 hours of life the total body water, extracellular water and intracellular water were 2.09 ± 0.25, 1.20 ± 0.19, and 0.90 ± 0.25 liters, respectively. By the 48th hour they were 1.87 ± 0.27, 1.08 ± 0.17, and 0.79 ± 0.21 liters, respectively. On the 10th day they were 2.02 ± 0.25, 1.29 ± 0.21, and 0.72 ± 0.14 liters, respectively, and after 1 month they were 2.34 ± 0.27, 1.62 ± 0.20, and 0.72 ± 0.13 liters, respectively. The behavior of the estimated volume was correlated with neonatal body weight changes, leading to a better interpretation of such changes. In conclusion, this study indicates the feasibility of bioelectrical impedance spectroscopy as a method to help fluid administration in intensive care neonatal units, and also contribute to the development of new equations to estimate neonatal body fluid contents.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this paper, the concept of available potential energy (APE) density is extended to a multicomponent Boussinesq fluid with a nonlinear equation of state. As shown by previous studies, the APE density is naturally interpreted as the work against buoyancy forces that a parcel needs to perform to move from a notional reference position at which its buoyancy vanishes to its actual position; because buoyancy can be defined relative to an arbitrary reference state, so can APE density. The concept of APE density is therefore best viewed as defining a class of locally defined energy quantities, each tied to a different reference state, rather than as a single energy variable. An important result, for which a new proof is given, is that the volume integrated APE density always exceeds Lorenz’s globally defined APE, except when the reference state coincides with Lorenz’s adiabatically re-arranged reference state of minimum potential energy. A parcel reference position is systematically defined as a level of neutral buoyancy (LNB): depending on the nature of the fluid and on how the reference state is defined, a parcel may have one, none, or multiple LNB within the fluid. Multiple LNB are only possible for a multicomponent fluid whose density depends on pressure. When no LNB exists within the fluid, a parcel reference position is assigned at the minimum or maximum geopotential height. The class of APE densities thus defined admits local and global balance equations, which all exhibit a conversion with kinetic energy, a production term by boundary buoyancy fluxes, and a dissipation term by internal diffusive effects. Different reference states alter the partition between APE production and dissipation, but neither affect the net conversion between kinetic energy and APE, nor the difference between APE production and dissipation. We argue that the possibility of constructing APE-like budgets based on reference states other than Lorenz’s reference state is more important than has been previously assumed, and we illustrate the feasibility of doing so in the context of an idealised and realistic oceanic example, using as reference states one with constant density and another one defined as the horizontal mean density field; in the latter case, the resulting APE density is found to be a reasonable approximation of the APE density constructed from Lorenz’s reference state, while being computationally cheaper.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this study, different methods of cutting fluid application are used in turning of a difficult-to-machine steel (SAE EV-8). Initially, a semisynthetic cutting fluid was applied using a conventional method (i.e. overhead flood cooling), minimum quantity of cutting fluid, and pulverization. A lubricant of vegetable oil (minimum quantity of lubricant) was also applied using the minimum quantity method. Thereafter, a cutting fluid jet under high pressure (3.0 MPa) was singly applied in the following regions: chip-tool interface, top surface of the chip (between workpiece and chip) and tool-workpiece contact. Moreover, two other methods were used: an interflow between conventional application and chip-tool interface jet (combined method) and, finally, three jets simultaneously applied. In order to carry out these tests, it was necessary to set up a high-pressure system using a piston pump for generating a cutting fluid jet, a venturi for fluid application (minimum quantity of cutting fluid and minimum quantity of lubricant) and a nozzle for cutting fluid pulverization. The output variables analyzed included tool life, surface roughness, cutting tool temperature, cutting force, chip form, chip compression rate and machined specimen microstructure. Among the results, it can be observed that the tool life increases and the cutting force decreases with the application of cutting fluid jet, mainly when it is directed to the chip-tool interface. Excluding the methods involving jet fluid, the conventional method seems to be more efficient than other methods of low pressure, such as minimum quantity of volume and pulverization, when considering just the cutting tool wear. © 2013 IMechE.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: Previously, we identified that the ATC/TTC haplotype formed by polymorphisms in the Interleukin-(IL)8 gene conferred susceptibility to chronic periodontitis (CP). The aim of the study was to investigate whether the IL8 haplotype ATC/TTC was associated with the volume of gingival crevicular fluid (GCF), the concentration of interleukin IL-8 in the GCF, as well as periodontal conditions in patients with CP in comparison to controls without CP. Methods: Seventy-nine individuals (CP: n = 41, controls: n = 38) were grouped according to the presence (susceptible for CP) or absence (not susceptible for CP) of the IL8 ATC/TTC haplotype. After periodontal clinical evaluation, they were subdivided by the presence or absence of CP. GCF was collected from each patient and the IL-8 levels were determined by ELISA. The GCF volume of each subject was measured by means of a calibrated electronic device. Comparisons of means between carriers and non-carriers of the ATC/TTC haplotype were evaluated using the Mann-Whitney test. Linear regression and stepwise linear regression analysis were used to analyse the association of the GCF volume with potential covariates and their contribution for the phenotype. Results: We did not find significant differences of both periodontal conditions and IL-8 concentration in the GCF of patients with the presence or absence of the IL8 ATC/TTC haplotype. However, the GCF volume was significantly higher amongst the patients affected by CP that are absent for the IL8 ATC/TTC haplotype. In addition, linear regression analysis showed a statistically significant association between GCF volume and CP, IL8 haplotype ATC/TTC and IL-8 concentration. Conclusions: The IL8 haplotype of susceptibility to CP was neither associated with IL-8 cytokine levels nor with clinical periodontal parameters. Also, CP, IL8 haplotype and IL-8 concentration showed a positive association with the GCF volume levels in the studied patients. (c) 2012 Published by Elsevier Ltd.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The measurement of fluid volumes in cases of pericardial effusion is a necessary procedure during autopsy. With the increased use of virtual autopsy methods in forensics, the need for a quick volume measurement method on computed tomography (CT) data arises, especially since methods such as CT angiography can potentially alter the fluid content in the pericardium. We retrospectively selected 15 cases with hemopericardium, which underwent post-mortem imaging and autopsy. Based on CT data, the pericardial blood volume was estimated using segmentation techniques and downsampling of CT datasets. Additionally, a variety of measures (distances, areas and 3D approximations of the effusion) were examined to find a quick and easy way of estimating the effusion volume. Segmentation of CT images as shown in the present study is a feasible method to measure the pericardial fluid amount accurately. Downsampling of a dataset significantly increases the speed of segmentation without losing too much accuracy. Some of the other methods examined might be used to quickly estimate the severity of the effusion volumes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Calorimetry is a nonspecific technique which allows direct measurement of heat generated by biological processes in the living cell. We evaluated the potential of calorimetry for rapid detection of bacterial growth in cerebrospinal fluid (CSF) in a rat model of bacterial meningitis. METHODS: Infant rats were infected on postnatal day 11 by direct intracisternal injection with either Streptococcus pneumoniae, Neisseria meningitidis or Listeria monocytogenes. Control animals were injected with sterile saline or heat-inactivated S. pneumoniae. CSF was obtained at 18 hours after infection for quantitative cultures and heat flow measurement. For calorimetry, 10 microl and 1 microl CSF were inoculated in calorimetry ampoules containing 3 ml trypticase soy broth (TSB). RESULTS: The mean bacterial titer (+/- SD) in CSF was 1.5 +/- 0.6 x 108 for S. pneumoniae, 1.3 +/- 0.3 x 106 for N. meningitidis and 3.5 +/- 2.2 x 104 for L. monocytogenes. Calorimetric detection time was defined as the time until heat flow signal exceeded 10 microW. Heat signal was detected in 10-microl CSF samples from all infected animals with a mean (+/- SD) detection time of 1.5 +/- 0.2 hours for S. pneumoniae, 3.9 +/- 0.7 hours for N. meningitidis and 9.1 +/- 0.5 hours for L. monocytogenes. CSF samples from non-infected animals generated no increasing heat flow (<10 microW). The total heat was the highest in S. pneumoniae ranging from 6.7 to 7.5 Joules, followed by L. monocytogenes (5.6 to 6.1 Joules) and N. meningitidis (3.5 to 4.4 Joules). The lowest detectable bacterial titer by calorimetry was 2 cfu for S. pneumoniae, 4 cfu for N. meningitidis and 7 cfu for L. monocytogenes. CONCLUSION: By means of calorimetry, detection times of <4 hours for S. pneumoniae and N. meningitidis and <10 hours for Listeria monocytogenes using as little as 10 microl CSF were achieved. Calorimetry is a new diagnostic method allowing rapid and accurate diagnosis of bacterial meningitis from a small volume of CSF.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND Ventricular torsion is an important component of cardiac function. The effect of septic shock on left ventricular torsion is not known. Because torsion is influenced by changes in preload, we compared the effect of fluid loading on left ventricular torsion in septic shock with the response in matched healthy control subjects. METHODS We assessed left ventricular torsion parameters using transthoracic echocardiography in 11 patients during early septic shock and in 11 age- and sex-matched healthy volunteers before and after rapid volume loading with 250 mL of a Ringer's lactate solution. RESULTS Peak torsion and peak apical rotation were reduced in septic shock (10.2 ± 5.2° and 5.6 ± 5.4°) compared with healthy volunteers (16.3 ± 4.5° and 9.6 ± 1.5°; P = 0.009 and P = 0.006 respectively). Basal rotation was delayed and diastolic untwisting velocity reached its maximum later during diastole in septic shock patients than in healthy volunteers (104 ± 16% vs 111 ± 14% and 13 ± 5% vs 21 ± 10%; P = 0.03 and P = 0.034, respectively). Fluid challenge increased peak torsion in both groups (septic shock, 10.2 ± 5.3° vs 12.6 ± 3.9°; healthy volunteers, 16.3 ± 4.5° vs 18.1 ± 6°; P = 0.01). Fluid challenge increased left ventricular stroke volume in septic shock patients (P = 0.003). CONCLUSIONS Compared with healthy volunteers, left ventricular torsion is impaired in septic shock patients. Fluid loading attenuates torsion abnormalities in parallel with increasing stroke volume. Reduced torsional motion might constitute a relevant component of septic cardiomyopathy, a notion that merits further testing in larger populations.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We postulated that neuromuscular disuse results in deleteriously affected tissue-vascular fluid exchange processes and subsequently damages the important oxidative bioenergetic process of intramuscular lipid metabolism. The in-depth research reported in the literature is somewhat limited by the ex vivo nature and sporadic time-course characterization of disuse atrophy and recovery. Thus, an in vivo controlled, localized animal model of disuse atrophy was developed in one of the hindlimbs of laboratory rabbits (employing surgically implanted tetrodotoxin (TTX)-filled mini-osmotic pump-sciatic nerve superfusion system) and tested repeatedly with magnetic resonance (MR) throughout the 2-week period of temporarily induced disuse and during the recovery period (following explantation of the TTX-filled pump) for a period of 3 weeks. Controls consisted of saline/"sham"-implanted rabbit hindlimbs. The validity of this model was established with repeated electrophysiologic nerve conduction testing using a clinically appropriate protocol and percutaneously inserted small needle stimulating and recording electrodes. Evoked responses recorded from proximal (P) and distal (D) sites to the sciatic nerve cuff in the TTX-implanted group revealed significantly decreased (p $<$ 0.001) proximal-to-distal (P/D) amplitude ratios (as much as 50-70% below Baseline/pre-implanted and sham-implanted group values) and significantly increased (p $<$ 0.01) differential latency (PL-DL) values (as much as 1.5 times the pre- and sham-implanted groups). By Day 21 of recovery, observed P/D and PL-DL levels matched Baseline/sham-implemented levels. MRI-determined cross-sectional area (CSA) values of Baseline/pre-implanted, sham- or TTX-implanted, and recovering/explanted and the corresponding contralateral hindlimb tibialis anterior (TA) muscles normalized to tibial bone (TB) CSA (in TA/TB ratios) revealed that there was a significant decline (indicative of atrophic response) from pre- and sham-implanted controls by as much as 20% (p $<$ 0.01) at Day 7 and 50-55% (p $<$ 0.001) at Day 13 of TTX-implantation. In the non-implanted contralaterals, a significant increase (indicative of hypertrophic response) by as much as 10% (p $<$ 0.025) at Day 7 and 27% (p $<$ 0.001) at Day 13 + TTX was found. The induced atrophic/hypertrophic TA muscles were observed to be fully recovered by Day 21 post-explantation as evidenced by image TA/TB ratios. End-point biopsy results from a small group of rabbits revealed comprehensive atrophy of both Type I and Type II fibers, although the heterogeneity of the response supports the use of image-guided, volume-localized proton magnetic resonance spectroscopy (MRS) to noninvasively assess tissue-level metabolic changes. MRS-determined results of a 0.25cc volume of tissue within implanted limb TA muscles under resting/pre-ischemic, ischemic-stressed, and post-ischemic conditions at timepoints during and following disuse atrophy/recovery revealed significantly increased intramuscular spectral lipid levels, as much as 2-3 times (p $<$ 0.01) the Baseline/pre-implanted values at Day 7 and 6-7 times (p $<$ 0.001) at Day 13 + TTX, which approached normal levels (compared to pre- and sham-implanted groups) by Day 21 of post-explanation recovery. (Abstract shortened by UMI.) ^