991 resultados para Vogt, KarlVogt, KarlKarlVogt
Resumo:
PURPOSE: Alpine ski performance relates closely to both anaerobic and aerobic capacities. During their competitive season, skiers greatly reduce endurance and weight training, and on-snow training becomes predominant. To typify this shift, we compared exhaustive ramp cycling and squat (SJ) and countermovement jumping (CMJ) performance in elite males before and after their competitive season. RESULTS: In postseason compared with preseason: 1) maximal oxygen uptake (VO 2 max) normalized to bodyweight was higher (55.2 +/- 5.2 vs 52.7 +/- 3.6 mL x kg(-1) x min(-1), P < 0.01), but corresponding work rate (W) was unchanged; 2) at ventilatory thresholds (VT), absolute and relative work rates were similar but heart rates were lower; 3) VO2/W slope was greater (9.59 +/- 0.6 vs 9.19 +/- 0.4 mL O2 x min(-1) x W(-1), P = 0.02), with similar flattening (P < 0.01) above V T1 at both time points; and 4) jump height was greater in SJ (47.4 +/- 4.4 vs 44.7 +/- 4.3 cm, P < 0.01) and CMJ (52.7 +/- 4.6 vs 50.4 +/- 5.0 cm, P < 0.01). DISCUSSION: We believe that aerobic capacity and leg power were constrained in preseason and that improvements primarily reflected an in-season recovery from a fatigued state, which was caused by incongruous preseason training. Residual adaptations to high-altitude exposure in preseason could have also affected the results. Nonetheless, modern alpine skiing seemingly provides an ample cardiovascular training stimulus for skiers to maintain their aerobic capacities during the racing season. CONCLUSIONS: We conclude that aerobic fitness and leg explosiveness can be maintained in-season but may be compromised by heavy or excessive preseason training. In addition, ramp test V O2/W slope analysis could be useful for monitoring both positive and negative responses to training.
Resumo:
BACKGROUND: Difference in pulse pressure (dPP) reliably predicts fluid responsiveness in patients. We have developed a respiratory variation (RV) monitoring device (RV monitor), which continuously records both airway pressure and arterial blood pressure (ABP). We compared the RV monitor measurements with manual dPP measurements. METHODS: ABP and airway pressure (PAW) from 24 patients were recorded. Data were fed to the RV monitor to calculate dPP and systolic pressure variation in two different ways: (a) considering both ABP and PAW (RV algorithm) and (b) ABP only (RV(slim) algorithm). Additionally, ABP and PAW were recorded intraoperatively in 10-min intervals for later calculation of dPP by manual assessment. Interobserver variability was determined. Manual dPP assessments were used for comparison with automated measurements. To estimate the importance of the PAW signal, RV(slim) measurements were compared with RV measurements. RESULTS: For the 24 patients, 174 measurements (6-10 per patient) were recorded. Six observers assessed dPP manually in the first 8 patients (10-min interval, 53 measurements); no interobserver variability occurred using a computer-assisted method. Bland-Altman analysis showed acceptable bias and limits of agreement of the 2 automated methods compared with the manual method (RV: -0.33% +/- 8.72% and RV(slim): -1.74% +/- 7.97%). The difference between RV measurements and RV(slim) measurements is small (bias -1.05%, limits of agreement 5.67%). CONCLUSIONS: Measurements of the automated device are comparable with measurements obtained by human observers, who use a computer-assisted method. The importance of the PAW signal is questionable.
Resumo:
BACKGROUND: The single-use supraglottic airway devices LMA-Supreme (LMA-S; Laryngeal Mask Company, Henley-on-Thames, United Kingdom) and i-gel (Intersurgical Ltd, Wokingham, Berkshire, United Kingdom) have a second tube for gastric tube insertion. Only the LMA-S has an inflatable cuff. They have the same clinical indications and might be useful for difficult airway management. This prospective, crossover, randomized controlled trial was performed in a simulated difficult airway scenario using an extrication collar limiting mouth opening and neck movement. METHODS: Sixty patients were included. Both devices were placed in random order in each patient. Primary outcome was overall success rate. Other measurements were time to successful ventilation, airway leak pressure, fiberoptic glottic view, and adverse events. RESULTS: Success rate for the LMA-S was 95% versus 93% for the i-gel (P = 1.000). LMA-S needed shorter insertion time (34 +/- 12 s vs. 42 +/- 23 s, P = 0.024). Tidal volumes and airway leak pressure were similar (LMA-S 26 +/- 8 cm H20; i-gel 27 +/- 9 cm H20; P = 0.441). Fiberoptic view through the i-gel showed less epiglottic downfolding. Overall agreement in insertion outcome was 54 (successes) and 1 (failure) or 55 (92%) of 60 patients. The difference in success rate was 1.7% (95% CI -11.3% to 7.6%). CONCLUSIONS: Both airway devices had similar insertion success and clinical performance in the simulated difficult airway situation. The authors found less epiglottic downfolding and better fiberoptic view but longer insertion time with the i-gel. Our study shows that both devices are feasible for emergency airway management in patients with reduced neck movement and limited mouth opening.
Resumo:
Laparoscopic surgery was introduced into clinical practice in the early 1950s by gynaecologists. Technical improvements allowed its use for more complex and longer lasting procedures. Reduction of postoperative pain, more favourable cosmetic results, quicker recovery and reduced length of hospital stay proved to be advantageous when compared to open surgery. As a result progressively older patients with corresponding pulmonary and cardiovascular comorbidities and morbidly obese patients are now undergoing advanced laparoscopic surgery. Detailed knowledge of the respiratory and hemodynamic pathophysiology induced by capnoperitoneum is necessary to administer safe anaesthesia to such patients. This review addresses the most important effects of capnoperitoneum and recent research as well as the possible implications for clinical practice.
Resumo:
BACKGROUND: To test the hypothesis that reduced responsiveness to adrenocorticotropin (ACTH) stimulation before elective major abdominal surgery is associated with an increased incidence of postoperative complications. METHODS: A low-dose (1 microg) ACTH test was performed the day before surgery, during the operation, on the first postoperative day, and before discharge from the hospital in 77 patients undergoing major abdominal surgery (age 62 [47;69] yrs [median, quartiles]; 30 female). Thirty-one patients undergoing minor, non-abdominal surgery (mostly inguinal hernia repair) (age 57 [40;66] yrs; 14 female) served as controls with minor surgical stress. A stimulated plasma cortisol concentration >or=500 nmol/l or an increment of >or=200 nmol/l in response to 1 microg ACTH was defined as normal. Scores for surgical stress and comprehensive risk, postoperative complications, and length of hospital stay (LOS) were assessed. RESULTS: On the day before major abdominal surgery, basal and stimulated plasma cortisol were 242 (165;299) nmol/l and 497 (404;568) nmol/l, respectively. Eighteen (23%) patients had an abnormal ACTH test, and 7 of these (39%) had complications versus 25 (42%) of the 59 patients with normal ACTH tests (P = .992). Surgical stress, comprehensive risk, and intra- and postoperative basal cortisol levels were higher and the response to ACTH stimulation smaller in patients with major abdominal compared to minor surgery. The peri-operative course of ACTH responses was not associated with complications or LOS in abdominal surgery patients. CONCLUSION: In patients scheduled for abdominal surgery, pre-operatively reduced adrenal response to stimulation with 1 microg ACTH is common but not associated with postoperative complications.