872 resultados para Validation of test results


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Asphalt pavement recycling has grown dramatically over the last few years as a viable technology to rehabilitate existing asphalt pavements. Iowa's current Cold In-place Recycling (CIR) practice utilizes a generic recipe specification to define the characteristics of the CIR mixture. As CIR continues to evolve, the desire to place CIR mixture with specific engineering properties requires the use of a mix design process. A new mix design procedure was developed for Cold In-place Recycling using foamed asphalt (CIR-foam) in consideration of its predicted field performance. The new laboratory mix design process was validated against various Reclaimed Asphalt Pavement (RAP) materials to determine its consistency over a wide range of RAP materials available throughout Iowa. The performance tests, which include dynamic modulus test, dynamic creep test and raveling test, were conducted to evaluate the consistency of a new CIR-foam mix design process to ensure reliable mixture performance over a wide range of traffic and climatic conditions. The “lab designed” CIR will allow the pavement designer to take the properties of the CIR into account when determining the overlay thickness.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Le ROTEM est un test de coagulation réalisable au près du malade qui permet d'objectiver la coagulopathie, de distinguer la contribution des différents éléments du système de coagulation et de cibler les produits procoagulants comme le plasma frais congelé (PFC), les plaquettes, le fibrinogène et les facteurs de coagulation purifiés ou les antifibrinolytiques. 3 des tests disponibles pour le ROTEM sont: EXTEM, INTEM, HEPTEM. Le premier test est stable sous hautes doses d'héparine alors que le deuxième est très sensible à sa présence. Dans le dernier test on rajoute de l'héparinase pour mettre en évidence l'éventuel effet résiduel de l'héparine en le comparant à l'INTEM. Idéalement, le ROTEM devrait être effectué avant la fin du bypass cardiopulmonaire (CEC), donc sous anticoagulation maximale pas héparine, afin de pouvoir administrer des produits pro¬coagulants dans les délais les plus brefs et ainsi limiter au maximum les pertes sanguines. En effet la commande et la préparation de certains produits procoagulants peut prendre plus d'une heure. Le but de cette étude est de valider l'utilisation du ROTEM en présence de hautes concentrations d'héparine. Il s'agit d'une étude observationnelle prospective sur 20 patients opérés électivement de pontages aorto-coronariens sous CEC. Méthode : l'analyse ROTEM a été réalisée avant l'administration d'héparine (TO), 10 minutes après l'administration d'héparine (Tl), à la fin de la CEC (T2) et 10 minutes après la neutralisation de l'anticoagulation avec la protamine (T3). L'état.d'héparinisation a été évalué par l'activité anti-Xa à T1,T2,T3. Résultats : Comparé à TO, la phase de polymérisation de la cascade de coagulation et l'interaction fibrine-plaquettes sont significativement détériorées par rapport à Tl pour les canaux EXTEM et HEPTEM. A T2 l'analyse EXTEM et INTEM sont comparables à celles de EXTEM et HEPTEM à T3. Conclusion: les hautes doses d'héparine utilisées induisent une coagulopathie qui reste stable durant toute la durée de la CEC et qui persiste même après la neutralisation de l'anticoagulation. Les mesures EXTEM et HEPTEM sont donc valides en présence de hautes concentrations d'héparine et peuvent être réalisés pendant la CEC avant l'administration de protamine.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

ABSTRACT: BACKGROUND: Most scales that assess the presence and severity of psychotic symptoms often measure a broad range of experiences and behaviours, something that restricts the detailed measurement of specific symptoms such as delusions or hallucinations. The Psychotic Symptom Rating Scales (PSYRATS) is a clinical assessment tool that focuses on the detailed measurement of these core symptoms. The goal of this study was to examine the psychometric properties of the French version of the PSYRATS. METHODS: A sample of 103 outpatients suffering from schizophrenia or schizoaffective disorders and presenting persistent psychotic symptoms over the previous three months was assessed using the PSYRATS. Seventy-five sample participants were also assessed with the Positive And Negative Syndrome Scale (PANSS). RESULTS: ICCs were superior to .90 for all items of the PSYRATS. Factor analysis replicated the factorial structure of the original version of the delusions scale. Similar to previous replications, the factor structure of the hallucinations scale was partially replicated. Convergent validity indicated that some specific PSYRATS items do not correlate with the PANSS delusions or hallucinations. The distress items of the PSYRATS are negatively correlated with the grandiosity scale of the PANSS. CONCLUSIONS: The results of this study are limited by the relatively small sample size as well as the selection of participants with persistent symptoms. The French version of the PSYRATS partially replicates previously published results. Differences in factor structure of the hallucinations scale might be explained by greater variability of its elements. The future development of the scale should take into account the presence of grandiosity in order to better capture details of the psychotic experience.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Cardiovascular magnetic resonance (CMR) has become an important diagnostic imaging modality in cardiovascular medicine. However, insufficient image quality may compromise its diagnostic accuracy. We aimed to describe and validate standardized criteria to evaluate a) cine steady-state free precession (SSFP), b) late gadolinium enhancement (LGE), and c) stress first-pass perfusion images. These criteria will serve for quality assessment in the setting of the Euro-CMR registry. METHODS: Thirty-five qualitative criteria were defined (scores 0-3) with lower scores indicating better image quality. In addition, quantitative parameters were measured yielding 2 additional quality criteria, i.e. signal-to-noise ratio (SNR) of non-infarcted myocardium (as a measure of correct signal nulling of healthy myocardium) for LGE and % signal increase during contrast medium first-pass for perfusion images. These qualitative and quantitative criteria were assessed in a total of 90 patients (60 patients scanned at our own institution at 1.5T (n=30) and 3T (n=30) and in 30 patients randomly chosen from the Euro-CMR registry examined at 1.5T). Analyses were performed by 2 SCMR level-3 experts, 1 trained study nurse, and 1 trained medical student. RESULTS: The global quality score was 6.7±4.6 (n=90, mean of 4 observers, maximum possible score 64), range 6.4-6.9 (p=0.76 between observers). It ranged from 4.0-4.3 for 1.5T (p=0.96 between observers), from 5.9-6.9 for 3T (p=0.33 between observers), and from 8.6-10.3 for the Euro-CMR cases (p=0.40 between observers). The inter- (n=4) and intra-observer (n=2) agreement for the global quality score, i.e. the percentage of assignments to the same quality tertile ranged from 80% to 88% and from 90% to 98%, respectively. The agreement for the quantitative assessment for LGE images (scores 0-2 for SNR <2, 2-5, >5, respectively) ranged from 78-84% for the entire population, and 70-93% at 1.5T, 64-88% at 3T, and 72-90% for the Euro-CMR cases. The agreement for perfusion images (scores 0-2 for %SI increase >200%, 100%-200%,<100%, respectively) ranged from 81-91% for the entire population, and 76-100% at 1.5T, 67-96% at 3T, and 62-90% for the Euro-CMR registry cases. The intra-class correlation coefficient for the global quality score was 0.83. CONCLUSIONS: The described criteria for the assessment of CMR image quality are robust with a good inter- and intra-observer agreement. Further research is needed to define the impact of image quality on the diagnostic and prognostic yield of CMR studies.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A quantitative model of water movement within the immediate vicinity of an individual root is developed and results of an experiment to validate the model are presented. The model is based on the assumption that the amount of water transpired by a plant in a certain period is replaced by an equal volume entering its root system during the same time. The model is based on the Darcy-Buckingham equation to calculate the soil water matric potential at any distance from a plant root as a function of parameters related to crop, soil and atmospheric conditions. The model output is compared against measurements of soil water depletion by rice roots monitored using γ-beam attenuation in a greenhouse of the Escola Superior de Agricultura "Luiz de Queiroz"/Universidade de São Paulo(ESALQ/USP) in Piracicaba, State of São Paulo, Brazil, in 1993. The experimental results are in agreement with the output from the model. Model simulations show that a single plant root is able to withdraw water from more than 0.1 m away within a few days. We therefore can assume that root distribution is a less important factor for soil water extraction efficiency.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: To validate a revision of the Mini Nutritional Assessment short-form (MNA(R)-SF) against the full MNA, a standard tool for nutritional evaluation. METHODS: A literature search identified studies that used the MNA for nutritional screening in geriatric patients. The contacted authors submitted original datasets that were merged into a single database. Various combinations of the questions on the current MNA-SF were tested using this database through combination analysis and ROC based derivation of classification thresholds. RESULTS: Twenty-seven datasets (n=6257 participants) were initially processed from which twelve were used in the current analysis on a sample of 2032 study participants (mean age 82.3y) with complete information on all MNA items. The original MNA-SF was a combination of six questions from the full MNA. A revised MNA-SF included calf circumference (CC) substituted for BMI performed equally well. A revised three-category scoring classification for this revised MNA-SF, using BMI and/or CC, had good sensitivity compared to the full MNA. CONCLUSION: The newly revised MNA-SF is a valid nutritional screening tool applicable to geriatric health care professionals with the option of using CC when BMI cannot be calculated. This revised MNA-SF increases the applicability of this rapid screening tool in clinical practice through the inclusion of a "malnourished" category.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Summary Background: We previously derived a clinical prognostic algorithm to identify patients with pulmonary embolism (PE) who are at low-risk of short-term mortality who could be safely discharged early or treated entirely in an outpatient setting. Objectives: To externally validate the clinical prognostic algorithm in an independent patient sample. Methods: We validated the algorithm in 983 consecutive patients prospectively diagnosed with PE at an emergency department of a university hospital. Patients with none of the algorithm's 10 prognostic variables (age >/= 70 years, cancer, heart failure, chronic lung disease, chronic renal disease, cerebrovascular disease, pulse >/= 110/min., systolic blood pressure < 100 mm Hg, oxygen saturation < 90%, and altered mental status) at baseline were defined as low-risk. We compared 30-day overall mortality among low-risk patients based on the algorithm between the validation and the original derivation sample. We also assessed the rate of PE-related and bleeding-related mortality among low-risk patients. Results: Overall, the algorithm classified 16.3% of patients with PE as low-risk. Mortality at 30 days was 1.9% among low-risk patients and did not differ between the validation and the original derivation sample. Among low-risk patients, only 0.6% died from definite or possible PE, and 0% died from bleeding. Conclusions: This study validates an easy-to-use, clinical prognostic algorithm for PE that accurately identifies patients with PE who are at low-risk of short-term mortality. Low-risk patients based on our algorithm are potential candidates for less costly outpatient treatment.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Age-related changes in lumbar vertebral microarchitecture are evaluated, as assessed by trabecular bone score (TBS), in a cohort of 5,942 French women. The magnitude of TBS decline between 45 and 85 years of age is piecewise linear in the spine and averaged 14.5 %. TBS decline rate increases after 65 years by 50 %. INTRODUCTION: This study aimed to evaluate age-related changes in lumbar vertebral microarchitecture, as assessed by TBS, in a cohort of French women aged 45-85 years. METHODS: An all-comers cohort of French Caucasian women was selected from two clinical centers. Data obtained from these centers were cross-calibrated for TBS and bone mineral density (BMD). BMD and TBS were evaluated at L1-L4 and for all lumbar vertebrae combined using GE-Lunar Prodigy densitometer images. Weight, height, and body mass index (BMI) also were determined. To validate our all-comers cohort, the BMD normative data of our cohort and French Prodigy data were compared. RESULTS: A cohort of 5,942 French women aged 45 to 85 years was created. Dual-energy X-ray absorptiometry normative data obtained for BMD from this cohort were not significantly different from French prodigy normative data (p = 0.15). TBS values at L1-L4 were poorly correlated with BMI (r = -0.17) and weight (r = -0.14) and not correlated with height. TBS values obtained for all lumbar vertebra combined (L1, L2, L3, L4) decreased with age. The magnitude of TBS decline at L1-L4 between 45 and 85 years of age was piecewise linear in the spine and averaged 14.5 %, but this rate increased after 65 years by 50 %. Similar results were obtained for other region of interest in the lumbar spine. As opposed to BMD, TBS was not affected by spinal osteoarthrosis. CONCLUSION: The age-specific reference curve for TBS generated here could therefore be used to help clinicians to improve osteoporosis patient management and to monitor microarchitectural changes related to treatment or other diseases in routine clinical practice.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In the last five years, Deep Brain Stimulation (DBS) has become the most popular and effective surgical technique for the treatent of Parkinson's disease (PD). The Subthalamic Nucleus (STN) is the usual target involved when applying DBS. Unfortunately, the STN is in general not visible in common medical imaging modalities. Therefore, atlas-based segmentation is commonly considered to locate it in the images. In this paper, we propose a scheme that allows both, to perform a comparison between different registration algorithms and to evaluate their ability to locate the STN automatically. Using this scheme we can evaluate the expert variability against the error of the algorithms and we demonstrate that automatic STN location is possible and as accurate as the methods currently used.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Computational network analysis provides new methods to analyze the brain's structural organization based on diffusion imaging tractography data. Networks are characterized by global and local metrics that have recently given promising insights into diagnosis and the further understanding of psychiatric and neurologic disorders. Most of these metrics are based on the idea that information in a network flows along the shortest paths. In contrast to this notion, communicability is a broader measure of connectivity which assumes that information could flow along all possible paths between two nodes. In our work, the features of network metrics related to communicability were explored for the first time in the healthy structural brain network. In addition, the sensitivity of such metrics was analysed using simulated lesions to specific nodes and network connections. Results showed advantages of communicability over conventional metrics in detecting densely connected nodes as well as subsets of nodes vulnerable to lesions. In addition, communicability centrality was shown to be widely affected by the lesions and the changes were negatively correlated with the distance from lesion site. In summary, our analysis suggests that communicability metrics that may provide an insight into the integrative properties of the structural brain network and that these metrics may be useful for the analysis of brain networks in the presence of lesions. Nevertheless, the interpretation of communicability is not straightforward; hence these metrics should be used as a supplement to the more standard connectivity network metrics.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

INTRODUCTION: Auscultatory nonmercury manual devices seem good alternatives for the mercury sphygmomanometers in the clinic and for research settings, but individual internal validation of each device is time-consuming. The aim of this study was to validate a new technique capable of testing two devices simultaneously, based on the International protocol of the European Society of Hypertension. METHODS: The concept of the new technique is to measure blood pressure alternatively by two observers using a mercury sphygmomanometer and by two observers using the A&D UM-101 and Accoson Greenlight 300 devices, connected by Y-tube to obtain simultaneous readings with both nonmercury devices. Thirty-three participants were enrolled (mean age 47.2±14.0 years). Nine sequential blood pressure measurements were performed for each participant. RESULTS: Both devices passed phase 1 using 15 participants. In phase 2.1 (n=33), on a maximum of 99 measurements, the Accoson device produced 81/95/99 measurements within 5/10/15 mmHg for systolic blood pressure (SBP) and 87/98/99 for diastolic blood pressure (DBP). The A&D device produced 86/96/99 for SBP and 94/99/99 for DBP. In phase 2.2 (n=33), 30 participants had at least 2 out of 3 SBP obtained with Accoson device within 5 mmHg of the mercury device, as compared with 29 of 33 participants with the A&D device. For DBP, this was 33 of 33 participants for both devices. CONCLUSION: Both the nonmercury devices passed the International protocol. The new technique of simultaneous device testing using a Y-tube represents a time saving application of the International protocol.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND AND PURPOSE: The DRAGON score predicts functional outcome in the hyperacute phase of intravenous thrombolysis treatment of ischemic stroke patients. We aimed to validate the score in a large multicenter cohort in anterior and posterior circulation. METHODS: Prospectively collected data of consecutive ischemic stroke patients who received intravenous thrombolysis in 12 stroke centers were merged (n=5471). We excluded patients lacking data necessary to calculate the score and patients with missing 3-month modified Rankin scale scores. The final cohort comprised 4519 eligible patients. We assessed the performance of the DRAGON score with area under the receiver operating characteristic curve in the whole cohort for both good (modified Rankin scale score, 0-2) and miserable (modified Rankin scale score, 5-6) outcomes. RESULTS: Area under the receiver operating characteristic curve was 0.84 (0.82-0.85) for miserable outcome and 0.82 (0.80-0.83) for good outcome. Proportions of patients with good outcome were 96%, 93%, 78%, and 0% for 0 to 1, 2, 3, and 8 to 10 score points, respectively. Proportions of patients with miserable outcome were 0%, 2%, 4%, 89%, and 97% for 0 to 1, 2, 3, 8, and 9 to 10 points, respectively. When tested separately for anterior and posterior circulation, there was no difference in performance (P=0.55); areas under the receiver operating characteristic curve were 0.84 (0.83-0.86) and 0.82 (0.78-0.87), respectively. No sex-related difference in performance was observed (P=0.25). CONCLUSIONS: The DRAGON score showed very good performance in the large merged cohort in both anterior and posterior circulation strokes. The DRAGON score provides rapid estimation of patient prognosis and supports clinical decision-making in the hyperacute phase of stroke care (eg, when invasive add-on strategies are considered).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND & AIMS: Standardized instruments are needed to assess the activity of eosinophilic esophagitis (EoE) and to provide end points for clinical trials and observational studies. We aimed to develop and validate a patient-reported outcome (PRO) instrument and score, based on items that could account for variations in patient assessments of disease severity. We also evaluated relationships between patient assessment of disease severity and EoE-associated endoscopic, histologic, and laboratory findings. METHODS: We collected information from 186 patients with EoE in Switzerland and the United States (69.4% male; median age, 43 y) via surveys (n = 135), focus groups (n = 27), and semistructured interviews (n = 24). Items were generated for the instruments to assess biologic activity based on physician input. Linear regression was used to quantify the extent to which variations in patient-reported disease characteristics could account for variations in patient assessment of EoE severity. The PRO instrument was used prospectively in 153 adult patients with EoE (72.5% male; median age, 38 y), and validated in an independent group of 120 patients with EoE (60.8% male; median age, 40.5 y). RESULTS: Seven PRO factors that are used to assess characteristics of dysphagia, behavioral adaptations to living with dysphagia, and pain while swallowing accounted for 67% of the variation in patient assessment of disease severity. Based on statistical consideration and patient input, a 7-day recall period was selected. Highly active EoE, based on endoscopic and histologic findings, was associated with an increase in patient-assessed disease severity. In the validation study, the mean difference between patient assessment of EoE severity (range, 0-10) and PRO score (range, 0-8.52) was 0.15. CONCLUSIONS: We developed and validated an EoE scoring system based on 7 PRO items that assess symptoms over a 7-day recall period. Clinicaltrials.gov number: NCT00939263.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: A patient's chest pain raises concern for the possibility of coronary heart disease (CHD). An easy to use clinical prediction rule has been derived from the TOPIC study in Lausanne. Our objective is to validate this clinical score for ruling out CHD in primary care patients with chest pain. Methods: This secondary analysis used data collected from a oneyear follow-up cohort study attending 76 GPs in Germany. Patients attending their GP with chest pain were questioned on their age, gender, duration of chest pain (1-60 min), sternal pain location, pain increases with exertion, absence of tenderness point at palpation, cardiovascular risks factors, and personal history of cardiovascular disease. Area under the curve (ROC), sensitivity and specificity of the Lausanne CHD score were calculated for patients with full data. Results: 1190 patients were included. Full data was available for 509 patients (42.8%). Missing data was not related to having CHD (p = 0.397) or having a cardiovascular risk factor (p = 0.275). 76 (14.9%) were diagnosed with a CHD. Prevalence of CHD were respectively of 68/344 (19.8%), 2/62 (3.2%), 6/103 (5.8%) in the high, intermediate and low risk category. ROC was of 72.9 (CI95% 66.8; 78.9). Ruling out patients with low risk has a sensitivity of 92.1% (CI95% 83.0; 96.7) and a specificity of 22.4% (CI95% 18.6%; 26.7%). Conclusion: The Lausanne CHD score shows reasonably good sensitivity and can be used to rule out coronary events in patients with chest pain. Patients at risk of CHD for other rarer reasons should nevertheless also be investigated.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

5-aminosalicylic acid (5-ASA) is an antiinflammatory drug widely used in the treatment of inflammatory bowel diseases. It is known to inhibit the production of cytokines and inflammatory mediators, but the mechanism underlying the intestinal effects of 5-ASA remains unknown. Based on the common activities of peroxisome proliferator-activated receptor-gamma (PPAR-gamma) ligands and 5-ASA, we hypothesized that this nuclear receptor mediates 5-ASA therapeutic action. To test this possibility, colitis was induced in heterozygous PPAR-gamma(+/-) mice and their wild-type littermates, which were then treated with 5-ASA. 5-ASA treatment had a beneficial effect on colitis only in wild-type and not in heterozygous mice. In epithelial cells, 5-ASA increased PPAR-gamma expression, promoted its translocation from the cytoplasm to the nucleus, and induced a modification of its conformation permitting the recruitment of coactivators and the activation of a peroxisome-proliferator response element-driven gene. Validation of these results was obtained with organ cultures of human colonic biopsies. These data identify PPAR-gamma as a target of 5-ASA underlying antiinflammatory effects in the colon.