1000 resultados para Tropospheric Ozone


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Brazilian National Institute for Space Research (INPE) is operating the Brazilian Environmental Data Collection System that currently amounts to a user community of around 100 organizations and more than 700 data collection platforms installed in Brazil. This system uses the SCD-1, SCD-2, and CBERS-2 low Earth orbit satellites to accomplish the data collection services. The main system applications are hydrology, meteorology, oceanography, water quality, and others. One of the functionalities offered by this system is the geographic localization of the data collection platforms by using Doppler shifts and a batch estimator based on least-squares technique. There is a growing demand to improve the quality of the geographical location of data collection platforms for animal tracking. This work presents an evaluation of the ionospheric and tropospheric effects on the Brazilian Environmental Data Collection System transmitter geographic location. Some models of the ionosphere and troposphere are presented to simulate their impacts and to evaluate performance of the platform location algorithm. The results of the Doppler shift measurements, using the SCD-2 satellite and the data collection platform (DCP) located in Cuiabá town, are presented and discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim: The purpose of this review is to present the potential for the incorporation of ozone therapy into the practice of dentistry. Background: Ozone gas has a high oxidation potential and is 1.5 times greater than chloride when used as an antimicrobial agent against bacteria, viruses, fungi, and protozoa. It also has the capacity to stimulate blood circulation and the immune response. Such features justify the current interest in its application in medicine and dentistry and have been indicated for the treatment of 260 different pathologies. It can be used for the treatment of alveolitis as a replacement for antibiotic therapy, as a mouthwash for reducing the oral microflora, as well as the adherence of microorganisms to tooth surfaces. Ozone has been shown to stimulate remineralization of recent caries-affected teeth after a period of about six to eight weeks. Conclusion: The future of ozone therapy must focus on the establishment of safe and well-defined parameters in accordance with randomized, controlled trials to determine the precise indications and guidelines in order to treat various medical and dental pathologies. Scientific support, as suggested by demonstrated studies, for ozone therapy presents a potential for an atraumatic, biologically-based treatment for conditions encountered in dental practice.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This research aimed at studying the oxidation process, to verify the effectiveness of coliform inactivation and to evaluate the formation of ozonation disinfection byproducts (DBP) in anoxic sanitary wastewater treated with ozone/hydrogen peroxide applied at doses of 2.6 mg O3 L-1 and 2.0 mg H2O2 L-1 with contact time of 10 min and 8.1 mg O3 L-1 and 8.0 mg H2O2 L-1 with contact time of 20 min. The mean chemical oxygen demand (COD) reductions were 7.50 and 9.40% for applied dosages of 2.5-2.8 and 6.4-9.4 mg O3 L-1 + 2.0 and 8.0 mg H2O2.L-1, respectively. The Escherichia coli (E. coli) inactivation range was 2.98-4.04 log10 and the total coliform inactivation range was 2.77-4.01 log10. The aldehydes investigated were formaldehyde, acetaldehyde, glyoxal and methylglyoxal. It was observed only the formation of acetaldehyde that ranged 5.53 to 29.68 μg L-1.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This ex vivo study evaluated the antibacterial effect of intracanal medications in root canals contaminated with Enterococcus faecalis. Fifty single-rooted human teeth were contaminated with E. faecalis (ATCC 29212) and incubated at 37°C for 21 days. The specimens were randomly divided into 5 groups according to the intracanal medication used: OZ-PG: ozonized propylene glycol; CH/CPMC: calcium hydroxide/camphorated paramonochlorophenol; OZ-PG/CH ozonized PG/CH; PC: positive control group (no medication); and NC: negative control group (no contamination). The samples were collected after 7 days (post-medication) and 14 days (final). Bacterial growth was checked by counting the colony-forming units (CFU). OZ-PG and CH/CPMC reduced significantly the CFU counts compared with PC in the post-medication and final samples, with no statistically significant differences among them. On the other hand, OZ-PG/CH did not reduce significantly the number of bacteria compared with PC. In conclusion, among the evaluated medications OZ-PG and CH/CPMC were the most effective against E. faecalis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Since all analgesics currently available for use in dogs have been associated with some adverse effects, the search for an effective analgesic that does not cause harm is important. This study investigated the postoperative analgesic effects of ozone administered either intrarectally or into acupoints in bitches undergoing ovariohysterectomy (OH). Twenty-four healthy adult bitches were randomly assigned to one of the three treatments 10min after sedation, as follows: 0.2mg/kg of intramuscular (IM) meloxicam (M); rectal insufflation of 10mL of 30μg/mL ozone (OI), or acupoint injection of 0.5mL ozone (30μg/mL; OA). Following sedation with acetylpromazine, anaesthesia was induced with propofol and fentanyl and maintained with isoflurane/O2. Pain was assessed using the modified Glasgow pain scale (MGPS) and the visual analogue scale (VAS) on the day before surgery, before anaesthesia, and at 1, 2, 4, 6, 8, 12 and 24h after surgery. Rescue analgesia was performed using 0.5mg/kg of morphine IM if MGPS was >3.33 points.No statistically significant differences in pain scales were found among the three analgesic protocols or the time points in each group ( P>. 0.05). Two dogs treated with OA required rescue analgesia. Meloxicam, rectal insufflation of ozone and ozone injected into acupoints provided satisfactory analgesia for 24. h in bitches undergoing elective OH. Ozone had no measurable adverse effects and is an alternative option to promote pain relief. © 2013 Elsevier Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Estimation of tropospheric gradients in GNSS data processing is a well-known technique to improve positioning (e.g. Bar-Sever et al., 1998; Chen and Herring, 1997). More recently, several authors also focused on the estimation of such parameters for meteorological studies and demonstrated their potential benefits (e.g. Champollion et al., 2004). Today, they are routinely estimated by several global and regional GNSS analysis centres but they are still not yet used for operational meteorology.This paper discusses the physical meaning of tropospheric gradients estimated from GPS observations recorded in 2011 by 13 permanent stations located in Corsica Island (a French Island in the western part of Italy). Corsica Island is a particularly interesting location for such study as it presents a significant environmental contrast between the continent and the sea, as well as a steep topography.Therefore, we estimated Zenith Total Delay (ZTD) and tropospheric gradients using two software: GAMIT/GLOBK (GAMIT version 10.5) and GIPSY-OASIS II version 6.1. Our results are then compared to radiosonde observations and to the IGS final troposphere products. For all stations we found a good agreement between the ZWD estimated by the two software (the mean of the ZWD differences is 1 mm with a standard deviation of 6 mm) but the tropospheric gradients are in less good agreement (the mean of the gradient differences is 0.1 mm with a standard deviation of 0.7 mm), despite the differences in the processing strategy (double-differences for GAMIT/GLOBK versus zero-difference for GIPSY-OASIS).We also observe that gradient amplitudes are correlated with the seasonal behaviour of the humidity. Like ZWD estimates, they are larger in summer than in winter. Their directions are stable over the time but not correlated with the IWV anomaly observed by ERA-Interim. Tropospheric gradients observed at many sites always point to inland throughout the year. These preferred directions are almost opposite to the largest slope of the local topography as derived from the world Digital Elevation Model ASTER GDEM v2. These first results give a physical meaning to gradients but the origin of such directions need further investigations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)