997 resultados para Thoracic Surgery.


Relevância:

60.00% 60.00%

Publicador:

Resumo:

OBJECTIVE: The major source of hemolysis during cardiopulmonary bypass remains the cardiotomy suction and is primarily due to the interaction between air and blood. The Smart suction system involves an automatically controlled aspiration designed to avoid the mixture of blood with air. This study was set-up to compare this recently designed suction system to a Cell Saver system in order to investigate their effects on blood elements during prolonged intrathoracic aspiration. METHODS: In a calf model (n=10; mean weight, 69.3+/-4.5 kg), a standardized hole was created in the right atrium allowing a blood loss of 100 ml/min, with a suction cannula placed into the chest cavity into a fixed position during 6 h. The blood was continuously aspirated either with the Smart suction system (five animals) or the Cell Saver system (five animals). Blood samples were taken hourly for blood cell counts and biochemistry. RESULTS: In the Smart suction group, red cell count, plasma protein and free hemoglobin levels remained stable, while platelet count exhibited a significant drop from the fifth hour onwards (prebypass: 683+/-201*10(9)/l, 5 h: 280+/-142*10(9)/l, P=0.046). In the Cell Saver group, there was a significant drop of the red cell count from the third hour onwards (prebypass: 8.6+/-0.9*10(12)/l, 6 h: 6.3+/-0.4*10(12)/l, P=0.02), of the platelet count from the first hour onwards (prebypass: 630+/-97*10(9)/l, 1 h: 224+/-75*10(9)/l, P<0.01), and of the plasma protein level from the first hour onwards (prebypass: 61.7+/-0.6 g/l, 1 h: 29.3+/-9.1 g/l, P<0.01). CONCLUSIONS: In this experimental set-up, the Smart suction system avoids damage to red cells and affects platelet count less than the Cell Saver system which induces important blood cell destruction, as any suction device mixing air and blood, as well as severe hypoproteinemia with its metabolic, clotting and hemodynamic consequences.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Background: Although there has been an abundant literature in recent years about farmer's lung disease, few addressed occupational measures able to maintain the farmer in his work. Nevertheless we know now that most of the farmers can be kept at the workplace by the way of occupational preventive measures. Methods: This matter is discussed from a case report. A farmer affected by the farmer's lung disease was sent to us by his pneumologist, in order to estimate the possibility of maintaining him in his job and to determine relevant changes at his workplace to minimize risk of exposure to dust antigen. This approach required a visit to the workplace by occupational physician and hygienist. Results: The visit of the workplace pointed out different habits and architectural particularities which were potential sources of exposure. The two main proposed measures to reduce the risk, were to wear respiratory masks while working inside the barn, such as preparing hay, feeding the cattle or sweeping the floor, and to build a direct access from the bathroom (shower and toilet) to the outside, allowing to go out of the barn after taking a shower and changing, without risk of being contaminated again. Although upgrading the shower-toilet is not yet completed to date, the already performed modifications led currently to significant clinical improvements, despite the risk of exposure was high since the animals were in the barn for more than two months. Conclusion: The treatment of the farmer's lung disease must be multidisciplinary involving general practitioner, pneumologist, occupational hygienist and occupational physician.

Relevância:

60.00% 60.00%

Publicador:

Relevância:

60.00% 60.00%

Publicador:

Resumo:

BACKGROUND: This study was designed to determine whether the pain pattern in patients with an internal mammary artery (IMA) harvest differs from that in other cardiac operations and whether these patients present specific characteristics with clinical implications. METHODS: One hundred patients with left IMA grafting (IMA group) were compared prospectively with 100 patients who had a heart operation without IMA harvest (non-IMA group). Pain assessment was performed on postoperative days (POD) 1, 2, 3, and 7, and included pain intensity (10-point scale) and pain localization. RESULTS: In the IMA group, pain intensity was higher on POD 2 (4.2 +/- 2.4 versus 3.2 +/- 2.3, p < 0.01), and there were more patients without pain on POD 7 (32 versus 19, p = 0.03). In the IMA group, more patients had left basal thoracic pain throughout the entire study period and had sternal pain on POD 7, whereas more patients in the non-IMA group complained about back pain during the early postoperative period. CONCLUSIONS: The impact of IMA harvest on pain intensity is moderate, but the pain localization pattern of each group exhibits specific features that could help to better target pain management.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Background. Anastomotic leak remains a common and potentially deleterious complication after esophagectomy. Preoperative embolization of the left gastric artery and splenic artery (PAE) has been suggested to lower anastomotic leak rates. We present the results of our 5-year experience with this technique.Methods. All patients undergoing PAE before esophagectomy since introduction of this technique in 2004 were compared in a 1: 2 matched-pair analysis with patients without PAE. Matching criteria were type of anastomosis, neoadjuvant treatment, comorbidity, and age. Data were derived from a retrospective chart review from 2000 to 2006 that was perpetuated as a prospective database up to date. Outcome measures were anastomotic leak, overall complications, and hospital stay.Results. Between 2000 and 2009, 102 patients underwent esophagectomy for cancer in our institution with an overall leak rate of 19% and a mortality of 8%. All 19 patients having PAE since 2004 were successfully matched 1: 2 to 38 control patients without PAE; both groups were similar regarding demographics and operation characteristics. Two PAE (11%) and 8 control patients (21%) had an anastomotic leak, but the difference was statistically not significant (p = 0.469). Overall and major complication rates for PAE and control group were 89% versus 79% (p = 0.469) and 37% versus 34% (p = 1.000), respectively. Median intensive care unit and hospital stay were 3 versus 3 days (p = 1.000) and 22 versus 17 days (p = 0.321), respectively.Conclusions. In our experience, PAE has no significant impact on complications and anastomotic leak in particular after esophagectomy. (Ann Thorac Surg 2011;91:1556-61) (C) 2011 by The Society of Thoracic Surgeons

Relevância:

60.00% 60.00%

Publicador:

Resumo:

OBJECTIVE: Balloon-expandable stent valves require flow reduction during implantation (rapid pacing). The present study was designed to compare a self-expanding stent valve with annular fixation versus a balloon-expandable stent valve. METHODS: Implantation of a new self-expanding stent valve with annular fixation (Symetis, Lausanne, Switzerland) was assessed versus balloon-expandable stent valve, in a modified Dynatek Dalta pulse duplicator (sealed port access to the ventricle for transapical route simulation), interfaced with a computer for digital readout, carrying a 25 mm porcine aortic valve. The cardiovascular simulator was programmed to mimic an elderly woman with aortic stenosis: 120/85 mmHg aortic pressure, 60 strokes/min (66.5 ml), 35% systole (2.8 l/min). RESULTS: A total of 450 cardiac cycles was analysed. Stepwise expansion of the self-expanding stent valve with annular fixation (balloon-expandable stent valve) resulted in systolic ventricular increase from 120 to 121 mmHg (126 to 830+/-76 mmHg)*, and left ventricular outflow obstruction with mean transvalvular gradient of 11+/-1.5 mmHg (366+/-202 mmHg)*, systolic aortic pressure dropped distal to the valve from 121 to 64.5+/-2 mmHg (123 to 55+/-30 mmHg) N.S., and output collapsed to 1.9+/-0.06 l/min (0.71+/-0.37 l/min* (before complete obstruction)). No valve migration occurred in either group. (*=p<0.05). CONCLUSIONS: Implantation of this new self-expanding stent valve with annular fixation has little impact on haemodynamics and has the potential for working heart implantation in vivo. Flow reduction (rapid pacing) is not necessary.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

OBJECTIVE: Standard cardiopulmonary bypass (CPB) circuits with their large surface area and volume contribute to postoperative systemic inflammatory reaction and hemodilution. In order to minimize these problems a new approach has been developed resulting in a single disposable, compact arterio-venous loop, which has integral kinetic-assist pumping, oxygenating, air removal, and gross filtration capabilities (CardioVention Inc., Santa Clara, CA, USA). The impact of this system on gas exchange capacity, blood elements and hemolysis is compared to that of a conventional circuit in a model of prolonged perfusion. METHODS: Twelve calves (mean body weight: 72.2+/-3.7 kg) were placed on cardiopulmonary bypass for 6 h with a flow of 5 l/min, and randomly assigned to the CardioVention system (n=6) or a standard CPB circuit (n=6). A standard battery of blood samples was taken before bypass and throughout bypass. Analysis of variance was used for comparison. RESULTS: The hematocrit remained stable throughout the experiment in the CardioVention group, whereas it dropped in the standard group in the early phase of perfusion. When normalized for prebypass values, both profiles differed significantly (P<0.01). Both O2 and CO2 transfers were significantly improved in the CardioVention group (P=0.04 and P<0.001, respectively). There was a slightly higher pressure drop in the CardioVention group but no single value exceeded 112 mmHg. No hemolysis could be detected in either group with all free plasma Hb values below 15 mg/l. Thrombocyte count, when corrected by hematocrit and normalized by prebypass values, exhibited an increased drop in the standard group (P=0.03). CONCLUSION: The CardioVention system with its concept of limited priming volume and exposed foreign surface area, improves gas exchange probably because of the absence of detectable hemodilution, and appears to limit the decrease in the thrombocyte count which may be ascribed to the reduced surface. Despite the volume and surface constraints, no hemolysis could be detected throughout the 6 h full-flow perfusion period.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

BACKGROUND: Aortoplasty has been advocated for moderate dilatation of the ascending aorta associated with aortic valve disease. We report our results with this conservative approach. METHODS: Seventeen consecutive patients with unsupported aortoplasty were reviewed. Twelve patients had aortic valve regurgitation and 5 had stenosis. The aortic wall was analyzed histologically in 14 patients. Follow-up was complete, with a mean time of 6 years (range, 2.3 to 10.5 years). RESULTS: Two patients among the 15 hospital survivors died during follow-up of causes unrelated to aortic pathology. Survival at 7 years was 86.7% (+/- 8.8%). Recurring aortic aneurysms developed in 4 patients after a mean time of 63 months, with an event-free survival at 7 years of 41% (+/- 21%). All of these 4 patients had aortic valve regurgitation and cystic medial necrosis. CONCLUSIONS: The recurrence rate of aneurysms after unsupported aortoplasty and aortic valve replacement is high in patients with aortic regurgitation. This strongly suggests that in these patients, the aortic dilatation is related to an underlying wall deficiency, associated with the aortic valve pathology, rather than to the hemodynamic stress imposed by the aortic valve disease.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

BACKGROUND: Chronic post-lobectomy empyema is rare but may require space obliteration for infection control. We report our experience by using a tailored thoracomyoplasty for this specific indication with respect to infection control and functional outcome. METHODS: We retrospectively analyzed 17 patients (11 men, 6 women) with chronic postlobectomy empyema who were treated by thoracomyoplasty in our institution between 2000 and 2011. All patients underwent an initial treatment attempt by use of chest tube drainage and antibiotics except those with suspicion of pleural aspergillosis (n = 6). In 5 patients, bronchus stump insufficiency was identified at preoperative bronchoscopy. A tailored thoracoplasty was combined with a serratus anterior-rhomboid myoplasty, which also served to close a bronchopleural fistula, if present. The first rib was resected in 11 of 17 patients. RESULTS: The 90-day mortality was 11.7%. Thoracomyoplasty was successful in all surviving patients with respect to infection control, space obliteration, and definitive closure of bronchopleural fistula, irrespective of the type of infection, the presence of a bronchopleural fistula, or whether a first rib resection was performed. Postlobectomy pulmonary function testing before and after thoracoplasty revealed a mean predicted FEV(1) of 63.0% ± 8.5% and 51.5% ± 4.2% (p = 0.01) and a mean predicted DLCO of 59.8% ± 11.6% and 54.5% ± 12.5%, respectively. Postoperative shoulder girdle dysfunction and scoliosis were prevented in patients willing to undergo intense physiotherapy. CONCLUSIONS: Tailored thoracomyoplasty represents a valid option for patients with chronic postlobectomy empyema without requiring a preceding open window thoracostomy. Space obliteration and infection control were equally obtained with and without first rib resection.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Background: The pathogenic role of anti-HLA antibodies (AHA) after kidney transplantation is well established. However, its significance after liver transplantation remains unclear. The aim of our study was to determine the prevalence and significance of AHA after liver transplantation. Methods: Between January 2007 and November 2007, all liver transplant recipients who were greater than 6 months posttransplantation and followed regularly at our transplant outpatient clinic (n = 95) were screened for AHA. All clinical and electronic records were reviewed. Serum samples were tested using multiplex technology (Luminex). A liver biopsy had been performed in 55 out of the 95 patients based on clinical grounds but no routine protocol biopsies were performed. Immunosuppression was calcineurin inhibitor-based in 90 patients, sirolimus-based in 4 patients and one patient had no anti-rejection therapy (operationally tolerant recipient). Results: The mean time from transplantation to study was 85 months (range 6-248 months). Overall, AHA were found in 23/95 (24.2%) of patients (5 had anti-class I alone, 13 anti-class II alone, and 4 had both anti-class I and II). However, only 4/95 patients (4.2%) had donor-specific antibodies (DSA) (one anti-class I and 3 anti-class II). Twenty-one out of 95 patients (22.1%) had a history of past or current biopsy-proven or radiological biliary complications (chronic rejection, ischemic cholangitis, ischemic type biliary lesions or biliary anastomosis stricture). Among patients with AHA, 4/23 (17,4%) had biliary complications, while it was 17/72 (23.6%) in patients without AHA (NS). Among patients with DSA, 3/4 (75%) had biliary complications (two with biopsy-proven chronic rejection in association with biliary strictures and one with ischemic cholangitis following hepatic artery thrombosis), versus 1/19 (5.3%) patients with AHA but no DSA (p = 0.009), versus 16/72 (22.2%) patients without AHA (p = 0.046). In patients with DSA, immunosuppression was not different than in patients without DSA. Conclusions: We found a 24% AHA prevalence. The presence of DSA, but not of AHA, was significantly associated with an increased incidence of biliary complications including chronic liver allograft rejection. The exact mechanisms and possible causal relationship linking DSA to biliary complications remain to be studied. Larger prospective trials are thus needed to further define the role of AHA and in particular of DSA after liver transplantation.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Background: Graft right ventricular (RV) function is compromised directly posttransplant, especially in heart transplantation (HTx) recipients with pretransplant pulmonary hypertension (PH). Graft RV size and systolic function, and the effect of the recipient's pulmonary haemodynamics on the graft extracellular matrix are not well characterised in the patients long-term after HTx. Aim: Comparison of RV size and systolic function in HTx recipients' long-term posttransplant stratified by the presence of pretransplant PH. Methods: HTx survivors >/=2 years posttransplant were divided into group I without pretransplant PH (pulmonary vascular resistance, PVR <2.5Wood units, n=37) and group II with PH (PVR >/=2.5Wood units, n=16). RV size and systolic function were measured using cardiac magnetic resonance imaging (CMR). The collagen content was assessed in septal endomyocardial biopsies obtained at HTx and at study inclusion. Results: Mean posttransplant follow-up was 5.2+/-2.9 years (group I) and 4.9+/-2.2 years (group II) (p=0.70). PVR was 1.5+/-0.6 vs 4.1+/-1.7Wood units pretransplant (p<0.001), and 1.2+/-0.5 vs 1.3+/-0.5Wood units at study inclusion (p=0.43). Allograft RV size and systolic function were similar in both groups (p always >/=0.07). Collagen content at transplantation and at follow-up were not different (p always >/=0.60). Conclusion: Posttransplant normalisation of pretransplant PH is associated with normal graft RV function long-term after HTx.