957 resultados para Thínk tank
Resumo:
Agitating liquids in unbaffled stirred tank leads to the formation of a vortex in the region of the impeller shaft when operating in the turbulent flow regime. A numerical model is presented here that captures such a vortex. The volume of fluid model, a multiphase flow model was employed in conjunction with a multiple reference frame model and the shear stress turbulence model. The dimensions of the tank considered here, were 0.585 m for the liquid depth and tank diameter with a 0.2925 m diameter impeller at a height of 0.2925 m. The impeller considered was an eight-bladed paddle type agitator that was rotating with an angular velocity of 7.54 rad s (72 rpm) giving a Reynolds number of 10 and Froude number of 0.043. Preliminary results of a second investigation into the effect of liquid phase properties on the vortex formed are also presented. © 2006 Elsevier B.V. All rights reserved.
Resumo:
For the first time, fully functional human mesenchymal stem cells (hMSCs) have been cultured at the litre-scale on microcarriers in a stirred-tank 5 l bioreactor, (2.5 l working volume) and were harvested via a potentially scalable detachment protocol that allowed for the successful detachment of hMSCs from the cell-microcarrier suspension. Over 12 days, the dissolved O2 concentration was >45 % of saturation and the pH between 7.2 and 6.7 giving a maximum cell density in the 5 l bioreactor of 1.7 × 105 cells/ml; this represents >sixfold expansion of the hMSCs, equivalent to that achievable from 65 fully-confluent T-175 flasks. During this time, the average specific O2 uptake of the cells in the 5 l bioreactor was 8.1 fmol/cell h and, in all cases, the 5 l bioreactors outperformed the equivalent 100 ml spinner-flasks run in parallel with respect to cell yields and growth rates. In addition, yield coefficients, specific growth rates and doubling times were calculated for all systems. Neither the upstream nor downstream bioprocessing unit operations had a discernible effect on cell quality with the harvested cells retaining their immunophenotypic markers, key morphological features and differentiation capacity. © 2013 Springer Science+Business Media Dordrecht.
Resumo:
General note: Title and date provided by Bettye Lane.
Resumo:
Audit report on the Iowa Petroleum Underground Storage Tank Board (UST Board) for the year ended June 30, 2015
Resumo:
In this study, the dynamic response of a vertical flexible cylinder vibrating at low mode numbers with combined x-y motion was investigated in a towing tank. The uniform flow was simulated by towing the flexible cylinder along the tank in still water; therefore, the turbulence intensity of the free flow was negligible in obtaining more reliable results. A lower branch of dominant frequencies with micro vibration amplitude was found in both cross-flow and in-line directions. This justifiable discrepancy was likely caused by an initial lock-in. The maximum attainable amplitude, modal analysis and x-y trajectory in cross-flow and in-line directions are reported here and compared with previous literature, along with some good agreements and different observations that were obtained from the study. Drag and lift coefficients are also evaluated by making use of a generalized integral transform technique approach, yielding an alternative method to study fluid force acting upon a flexible cylinder.
Resumo:
As advances in numerical modelling techniques support the increased confidence in predictions from computer simulations, the need remains to have experimental verification built into the design process. This paper outlines the experimental investigation carried out on a shielded vertical axis turbine in a marine environment. The experiments consist of performance measurements and the use of particle image velocimetry on a small scale device in a marine current flume. The results demonstrate that the performance of the device can be modelled numerically; in particular, the results show that the numerical model used can correctly predict the increase in performance with Reynolds number.
Resumo:
One key step of the industrial development of a tidal energy device is the testing of scale prototype devices within a controlled laboratory environment. At present, there is no available experimental protocol which addresses in a quantitative manner the differences which can be expected between results obtained from the different types of facilities currently employed for this type of testing. As a consequence, where differences between results are found it has been difficult to confirm the extent to which these differences relate to the device performance or to the test facility type. In the present study, a comparative ”Round Robin” testing programme has been conducted as part of the EC FP VII MaRINET program in order to evaluate the impact of different experimental facilities on the test results. The aim of the trials was to test the same model tidal turbine in four different test facilities to explore the sensitivity of the results to the choice of facility. The facilities comprised two towing tanks, of very different size, and two circulating water channels. Performance assessments in terms of torque, drag and inflow speed showed very similar results in all facilities. However, expected differences between the different tank types (circulating and towing) were observed in the fluctuations of torque and drag measurements. The main facility parameters which can influence the behaviour of the turbine were identified; in particular the effect of blockage was shown to be significant in cases yielding for high thrust coefficients, even at relatively small blockage ratios.
Resumo:
Despite the development of improved performance test protocols by renowned researchers, there are still road networks which experience premature cracking and failure. One area of major concern in asphalt science and technology, especially in cold regions in Canada is thermal (low temperature) cracking. Usually right after winter periods, severe cracks are seen on poorly designed road networks. Quality assurance tests based on improved asphalt performance protocols have been implemented by government agencies to ensure that roads being constructed are at the required standard but asphalt binders that pass these quality assurance tests still crack prematurely. While it would be easy to question the competence of the quality assurance test protocols, it should be noted that performance tests which are being used and were repeated in this study, namely the extended bending beam rheometer (EBBR) test, double edge-notched tension test (DENT), dynamic shear rheometer (DSR) test and X-ray fluorescence (XRF) analysis have all been verified and proven to successfully predict asphalt pavement behaviour in the field. Hence this study looked to probe and test the quality and authenticity of the asphalt binders being used for road paving. This study covered thermal cracking and physical hardening phenomenon by comparing results from testing asphalt binder samples obtained from the storage ‘tank’ prior to paving (tank samples) and recovered samples for the same contracts with aim of explaining why asphalt binders that have passed quality assurance tests are still prone to fail prematurely. The study also attempted to find out if the short testing time and automated procedure of torsion bar experiments can replace the established but tedious procedure of the EBBR. In the end, it was discovered that significant differences in performance and composition exist between tank and recovered samples for the same contracts. Torsion bar experimental data also indicated some promise in predicting physical hardening.
Resumo:
The objective of the present study was to evaluate the occurrence of Staphylococcus aureus in milk produced in 37 farms located in the regions of Ribeirão Preto and São Carlos, state of São Paulo, Brazil. Two-hundred and eight samples of milk from individual cows showing subclinical mastitis, and 37 samples of bulk tank milk were analyzed. S. aureus strains were detected in 18 (7.3%) milk samples: 14 (6.7%) from samples of individual cows, and 4 (10.8%) from bulk tank milk. Two individual milk samples (14.3%) and two bulk milk samples contained enterotoxigenic S. aureus. PFGE analysis revealed the genetic heterogeneity of the strains isolated from raw milk, which presented to 13 S. aureus patterns. Results confirmed the potential transmission of staphylococcal food poisoning to consumers via milk of cows affected by subclinical mastitis, mainly when raw milk is ingested.
Resumo:
Este trabalho faz uma análise das estimativas de teores de umidade obtidas com o método Ground Penetrating Radar (GPR) comparativamente às determinadas com os métodos Time Domain Reflectometry (TDR) e gravimétrico. Os dados foram obtidos em dois experimentos diferentes: um experimento controlado em laboratório buscando reproduzir um meio homogêneo onde foram obtidas as medidas de umidade com GPR (antenas de 1 GHz) e TDR, e outro experimento de campo onde foram obtidos dados com GPR (antenas de 200 MHz) e de amostras de solos do local. Para a obtenção das estimativas a partir do método GPR foram analisados os eventos relativos à onda de transmissão direta entre as antenas, onda refratada criticamente e onda refletida em interfaces com diferentes propriedades elétricas.O GPR mostrou-se sensível às variações de umidades presentes nos dois experimentos e apresentou boa correlação com os dados obtidos com TDR (REQM de0,007 m³m-3) e das amostras (REQM de 0,039 m³m-3).
Resumo:
The vinasse, awaste produced in the proportion of 13 liters for each liter of alcohol. It has a high potential of polluting groundwater and superficial water resources, changes the soil behaviour and can also develop sanilization problems. This work aims to evaluate the efficiency of the DC-resistivity method in detecting and mapping anomalies caused by inappropriate disposal of vinasse in an inactive infiltration tank located at Sepé-Tiarajú settlement of landless agricultural laborers in the Ribeirão Preto region. Besides, as secondary goals, this work aims to characterize the type of anomaly residue as well as to diagnose its influence inside and outside of the limits of the tank. Eleven electrical resistivity tomography profiles were carried out with the dipole-dipole array, 10m of dipoles length and 5 leveis of investigation The geophysical survey enabled us to conclude that the DC-resistivity method is appropriate for mapping the contamination plume caused by intense vinasse disposal and its influence. It enabled also to conclude that the contamination exceeds the tank limits. The vinasse influence can be characterized by low resistivity values between 10 Ohm.m and 90 Ohm.m and its behavior can be compared with the one of the chorume, which is also conductive.