951 resultados para Single-Trial
Resumo:
BACKGROUND: The aim of this multicenter trial was to prospectively evaluate neo-adjuvant chemotherapy followed by extrapleural pneumonectomy (EPP) and radiotherapy, including quality of life as outcome. PATIENTS AND METHODS: Eligible patients had malignant pleural mesothelioma of all histological types, World Health Organization performance status of zero to two and clinical stage T1-T3, N0-2, M0 disease considered completely resectable. Neo-adjuvant chemotherapy consisted of three cycles of cisplatin and gemcitabine followed by EPP. Postoperative radiotherapy was considered for all patients. RESULTS: In all, 58 of 61 patients completed three cycles of neo-adjuvant chemotherapy. Forty-five patients (74%) underwent EPP and in 37 patients (61%) the resection was complete. Postoperative radiotherapy was initiated in 36 patients. The median survival of all patients was 19.8 months [95% confidence interval (CI) 14.6-24.5]. For the 45 patients undergoing EPP, the median survival was 23 months (95% CI 16.6-32.9). Psychological distress showed minor variations over time with distress above the cut-off score indicating no morbidity with 82% (N = 36) at baseline and 76% (N = 26) at 3 months after surgery (P = 0.5). CONCLUSIONS: The observed rate of operability is promising. A median survival of 23 months for patients undergoing EPP compares favourably with the survival reported from single center studies of upfront surgery. This approach was not associated with an increase in psychological distress.
Resumo:
This phase III trial compared the efficacy and safety of gemcitabine (Gem) plus capecitabine (GemCap) versus single-agent Gem in advanced/metastatic pancreatic cancer.
Resumo:
BACKGROUND: Conventionally, endosseous dental implants have required 3 to 6 months of uninterrupted healing based on observations for dental implants that were characterized by a relatively smooth machined surface. Many studies have since demonstrated that implants with a roughened surface resulted in greater bone apposition, earlier bone contact, and a stronger bond between the implant and the bone, suggesting that implants with roughened surfaces could be loaded earlier than 3 to 6 months. Formal clinical studies confirmed that implants with rough surfaces can have abutments placed and be loaded occlusally as early as 6 weeks postplacement. The purpose of this prospective, human clinical investigation was to evaluate a large number of implants with a specific rough surface (sand-blasted acid-etched [SLA]) placed in everyday practice under routine private-practice conditions. METHODS: A prospective, multicenter, human clinical observational study was initiated with the goal of recruiting a minimum of 500 patients and 800 implants. The implants were to be placed and restored in predominantly private-practice settings around the world. Ninety-two practitioners in 16 countries agreed to participate, and 86 followed the study design. Patients had to be in good health, have sufficient bone to encase the implant, and agree to return for recall appointments. Exclusion criteria included heavy smoking (>10 cigarettes a day) and bone augmentation procedures at the implant site. All implants were two-piece (an abutment was to be placed after 6 weeks of healing) and were characterized by the presence of a transmucosal polished collar. Each implant had an SLA surface. All implants were positioned using a non-submerged (single-stage) surgical technique. Survival and success rates were calculated by life-table analyses. RESULTS: A total of 706 patients were enrolled and 1,406 implants were placed. In the final analyses, 590 patients with 990 implants (70.4% of those enrolled) met all inclusion criteria, including placement of an abutment and provisional restoration within 63 days of surgical placement. The majority of implants were 10 and 12 mm long (78.7%) and were placed in type II and III bone (87%). Seventy-three percent of the implants were placed in the mandible, and 27% were placed in the maxilla. The cumulative survival rate was 99.56% at 3 years and 99.26% at 5 years. The overall success rate was 99.12% at 3 years and 97.38% after 5 years. CONCLUSIONS: Under private-practice conditions, implants with an SLA surface could be placed and restored predictably within 6 to 8 weeks. Data from this prospective, multicenter, human observational study reinforced the results of more formal clinical studies and demonstrated that implants with the SLA surface can be restored in patients in approximately half of the time of conventional healing periods.
Resumo:
BACKGROUND: Coronary stents improve immediate and late results of balloon angioplasty by tacking up dissections and preventing wall recoil. These goals are achieved within weeks after angioplasty, but with current technology stents permanently remain in the artery, with many limitations including the need for long-term antiplatelet treatment to avoid thrombosis. We report a prospective multicentre clinical trial of coronary implantations of absorbable magnesium stents. METHODS: We enrolled 63 patients (44 men; mean age 61.3 [SD 9.5 years]) in eight centres with single de novo lesions in a native coronary artery in a multicentre, non-randomised prospective study. Follow-up included coronary angiography and intravascular ultrasound at 4 months and clinical assessment at 6 months and 12 months. The primary endpoint was cardiac death, non-fatal myocardial infarction, or clinically driven target lesion revascularisation at 4 months FINDINGS: 71 stents, 10-15 mm in length and 3.0-3.5 mm in diameter, were successfully implanted after pre-dilatation in 63 patients. Diameter stenosis was reduced from 61.5 (SD 13.1%) to 12.6 (5.6%) with an acute gain of 1.41 mm (0.46 mm) and in-stent late loss of 1.08 mm (0.49 mm). The ischaemia-driven target lesion revascularisation rate was 23.8% after 4 months, and the overall target lesion revascularisation rate was 45% after 1 year. No myocardial infarction, subacute or late thrombosis, or death occurred. Angiography at 4 months showed an increased diameter stenosis of 48.4 (17.0%). After serial intravascular ultrasound examinations, only small remnants of the original struts were visible, well embedded into the intima. Neointimal growth and negative remodelling were the main operating mechanisms of restenosis. INTERPRETATION: This study shows that biodegradable magnesium stents can achieve an immediate angiographic result similar to the result of other metal stents and can be safely degraded after 4 months. Modifications of stent characteristics with prolonged degradation and drug elution are currently in development.
Resumo:
PURPOSE: Two noninvasive methods to measure dental implant stability are damping capacity assessment (Periotest) and resonance frequency analysis (Osstell). The objective of the present study was to assess the correlation of these 2 techniques in clinical use. MATERIALS AND METHODS: Implant stability of 213 clinically stable loaded and unloaded 1-stage implants in 65 patients was measured in triplicate by means of resonance frequency analysis and Periotest. Descriptive statistics as well as Pearson's, Spearman's, and intraclass correlation coefficients were calculated with SPSS 11.0.2. RESULTS: The mean values were 57.66 +/- 8.19 implant stability quotient for the resonance frequency analysis and -5.08 +/- 2.02 for the Periotest. The correlation of both measuring techniques was -0.64 (Pearson) and -0.65 (Spearman). The single-measure intraclass correlation coefficients for the ISQ and Periotest values were 0.99 and 0.88, respectively (95% CI). No significant correlation of implant length with either resonance frequency analysis or Periotest could be found. However, a significant correlation of implant diameter with both techniques was found (P < .005). The correlation of both measuring systems is moderate to good. It seems that the Periotest is more susceptible to clinical measurement variables than the Osstell device. The intraclass correlation indicated lower measurement precision for the Periotest technique. Additionally, the Periotest values differed more from the normal (Gaussian) curve of distribution than the ISQs. Both measurement techniques show a significant correlation to the implant diameter. CONCLUSION: Resonance frequency analysis appeared to be the more precise technique.
Resumo:
BACKGROUND: Sedation is a cornerstone in the premedication for percutaneous coronary intervention (PCI). Benzodiazepines and opioids are frequently used. Previous results suggest that opioids mimic the adaptation to ischemia during repeated balloon inflations and may provide direct myocardial protection in addition to their sedative effect. However, no comparative data exist. METHODS: We conducted a prospective, randomized, controlled, single-blind trial comparing diazepam and fentanyl in 276 patients undergoing elective PCI. Patients were randomized to either diazepam 5 mg sublingually or fentanyl 0.05 mg or 0.1 mg intravenously at least 5 minutes prior to the first balloon inflation. The primary end-point was the postprocedural elevation of myocardial markers of necrosis defined as an elevation of cardiac troponin T > or = 0.01 ng/ml. RESULTS: The three groups had similar baseline clinical, angiographic, and procedural characteristics, with no significant differences in lesion morphology, procedural complexity, or adjunctive medical treatment. No significant variation in the hemodynamic response to the study drugs was observed in the three groups. The rate of postprocedural troponin T elevation was 28% in the diazepam group, 20% in the fentanyl 0.05 mg group, and 30% in the fentanyl 0.1 mg group (P = 0.26). Rates of postprocedural myocardial infarction were 3%, 2%, and 2%, respectively (P = 0.84), with one case of in-hospital death in the diazepam group and no urgent TVR in the whole study population. CONCLUSION: Although providing a well-tolerated alternative to diazepam for sedation during PCI, fentanyl did not provide additional cardioprotection assessed through the postinterventional elevation of cardiac troponin T during elective coronary intervention.
Resumo:
Single-screw extrusion is one of the widely used processing methods in plastics industry, which was the third largest manufacturing industry in the United States in 2007 [5]. In order to optimize the single-screw extrusion process, tremendous efforts have been devoted for development of accurate models in the last fifty years, especially for polymer melting in screw extruders. This has led to a good qualitative understanding of the melting process; however, quantitative predictions of melting from various models often have a large error in comparison to the experimental data. Thus, even nowadays, process parameters and the geometry of the extruder channel for the single-screw extrusion are determined by trial and error. Since new polymers are developed frequently, finding the optimum parameters to extrude these polymers by trial and error is costly and time consuming. In order to reduce the time and experimental work required for optimizing the process parameters and the geometry of the extruder channel for a given polymer, the main goal of this research was to perform a coordinated experimental and numerical investigation of melting in screw extrusion. In this work, a full three-dimensional finite element simulation of the two-phase flow in the melting and metering zones of a single-screw extruder was performed by solving the conservation equations for mass, momentum, and energy. The only attempt for such a three-dimensional simulation of melting in screw extruder was more than twenty years back. However, that work had only a limited success because of the capability of computers and mathematical algorithms available at that time. The dramatic improvement of computational power and mathematical knowledge now make it possible to run full 3-D simulations of two-phase flow in single-screw extruders on a desktop PC. In order to verify the numerical predictions from the full 3-D simulations of two-phase flow in single-screw extruders, a detailed experimental study was performed. This experimental study included Maddock screw-freezing experiments, Screw Simulator experiments and material characterization experiments. Maddock screw-freezing experiments were performed in order to visualize the melting profile along the single-screw extruder channel with different screw geometry configurations. These melting profiles were compared with the simulation results. Screw Simulator experiments were performed to collect the shear stress and melting flux data for various polymers. Cone and plate viscometer experiments were performed to obtain the shear viscosity data which is needed in the simulations. An optimization code was developed to optimize two screw geometry parameters, namely, screw lead (pitch) and depth in the metering section of a single-screw extruder, such that the output rate of the extruder was maximized without exceeding the maximum temperature value specified at the exit of the extruder. This optimization code used a mesh partitioning technique in order to obtain the flow domain. The simulations in this flow domain was performed using the code developed to simulate the two-phase flow in single-screw extruders.
Resumo:
BACKGROUND: Bleeding is a frequent complication during surgery. The intraoperative administration of blood products, including packed red blood cells, platelets and fresh frozen plasma (FFP), is often live saving. Complications of blood transfusions contribute considerably to perioperative costs and blood product resources are limited. Consequently, strategies to optimize the decision to transfuse are needed. Bleeding during surgery is a dynamic process and may result in major blood loss and coagulopathy due to dilution and consumption. The indication for transfusion should be based on reliable coagulation studies. While hemoglobin levels and platelet counts are available within 15 minutes, standard coagulation studies require one hour. Therefore, the decision to administer FFP has to be made in the absence of any data. Point of care testing of prothrombin time ensures that one major parameter of coagulation is available in the operation theatre within minutes. It is fast, easy to perform, inexpensive and may enable physicians to rationally determine the need for FFP. METHODS/DESIGN: The objective of the POC-OP trial is to determine the effectiveness of point of care prothrombin time testing to reduce the administration of FFP. It is a patient and assessor blind, single center randomized controlled parallel group trial in 220 patients aged between 18 and 90 years undergoing major surgery (any type, except cardiac surgery and liver transplantation) with an estimated blood loss during surgery exceeding 20% of the calculated total blood volume or a requirement of FFP according to the judgment of the physicians in charge. Patients are randomized to usual care plus point of care prothrombin time testing or usual care alone without point of care testing. The primary outcome is the relative risk to receive any FFP perioperatively. The inclusion of 110 patients per group will yield more than 80% power to detect a clinically relevant relative risk of 0.60 to receive FFP of the experimental as compared with the control group. DISCUSSION: Point of care prothrombin time testing in the operation theatre may reduce the administration of FFP considerably, which in turn may decrease costs and complications usually associated with the administration of blood products. TRIAL REGISTRATION: NCT00656396.
Resumo:
BACKGROUND: Single photodynamic therapy (PDT) has been effective in initial periodontal therapy, but only improved bleeding on probing (BoP) in maintenance patients after a single use. Repeated PDT has not been addressed. OBJECTIVES: To study the possible added benefits of repeated adjunctive PDT to conventional treatment of residual pockets in patients enrolled in periodontal maintenance. MATERIAL AND METHODS: Ten maintenance patients with 70 residual pockets [probing pocket depth (PPD)>or=5 mm] were randomly assigned for treatment five times in 2 weeks (Days 0, 1, 2, 7, 14) with PDT (test) or non-activated laser (control) following debridement. The primary outcome variable was PPD, and the secondary variables were clinical attachment level (CAL) and BoP. These were assessed at 3, 6 and 12 months following the interventions. RESULTS: Greater PPD reductions were observed in the test (-0.67 +/- 0.34; p=0.01) compared with the control patients (-0.04 +/- 0.33; NS) after 6 months. Significant CAL gain (+0.52 +/- 0.31; p=0.01) was noted for the test, but not in the control (-0.27 +/- 0.52; NS) patients after 6 months. BoP percentages decreased significantly in test (97-64%, 67%, 77%), but not control patients after 3, 6 and 12 months. CONCLUSIONS: Repeated (five times) PDT adjunctive to debridement yielded improved clinical outcomes in residual pockets in maintenance patients. The effects were best documented after 6 months.
Resumo:
To compare clinical benefit response (CBR) and quality of life (QOL) in patients receiving gemcitabine (Gem) plus capecitabine (Cap) versus single-agent Gem for advanced/metastatic pancreatic cancer.
Resumo:
BACKGROUND A newly developed collagen matrix (CM) of porcine origin has been shown to represent a potential alternative to palatal connective tissue grafts (CTG) for the treatment of single Miller Class I and II gingival recessions when used in conjunction with a coronally advanced flap (CAF). However, at present it remains unknown to what extent CM may represent a valuable alternative to CTG in the treatment of Miller Class I and II multiple adjacent gingival recessions (MAGR). The aim of this study was to compare the clinical outcomes following treatment of Miller Class I and II MAGR using the modified coronally advanced tunnel technique (MCAT) in conjunction with either CM or CTG. METHODS Twenty-two patients with a total of 156 Miller Class I and II gingival recessions were included in this study. Recessions were randomly treated according to a split-mouth design by means of MCAT + CM (test) or MCAT + CTG (control). The following measurements were recorded at baseline (i.e. prior to surgery) and at 12 months: Gingival Recession Depth (GRD), Probing Pocket Depth (PD), Clinical Attachment Level (CAL), Keratinized Tissue Width (KTW), Gingival Recession Width (GRW) and Gingival Thickness (GT). GT was measured 3-mm apical to the gingival margin. Patient acceptance was recorded using a Visual Analogue Scale (VAS). The primary outcome variable was Complete Root Coverage (CRC), secondary outcomes were Mean Root Coverage (MRC), change in KTW, GT, patient acceptance and duration of surgery. RESULTS Healing was uneventful in both groups. No adverse reactions at any of the sites were observed. At 12 months, both treatments resulted in statistically significant improvements of CRC, MRC, KTW and GT compared with baseline (p < 0.05). CRC was found at 42% of test sites and at 85% of control sites respectively (p < 0.05). MRC measured 71 ± 21% mm at test sites versus 90 ± 18% mm at control sites (p < 0.05). Mean KTW measured 2.4 ± 0.7 mm at test sites versus 2.7 ± 0.8 mm at control sites (p > 0.05). At test sites, GT values changed from 0.8 ± 0.2 to 1.0 ± 0.3 mm, and at control sites from 0.8 ± 0.3 to 1.3 ± 0.4 mm (p < 0.05). Duration of surgery and patient morbidity was statistically significantly lower in the test compared with the control group respectively (p < 0.05). CONCLUSIONS The present findings indicate that the use of CM may represent an alternative to CTG by reducing surgical time and patient morbidity, but yielded lower CRC than CTG in the treatment of Miller Class I and II MAGR when used in conjunction with MCAT.
Resumo:
OBJECTIVES This study aims to assess the effects of rinsing with zinc- and chlorhexidine-containing mouth rinse with or without adjunct tongue scraping on volatile sulfur compounds (VSCs) in breath air, and the microbiota at the dorsum of the tongue. MATERIAL AND METHODS A randomized single-masked controlled clinical trial with a cross-over study design over 14 days including 21 subjects was performed. Bacterial samples from the dorsum of the tongue were assayed by checkerboard DNA-DNA hybridization. RESULTS No halitosis (identified by VSC assessments) at day 14 was identified in 12/21 subjects with active rinse alone, in 10/21 with adjunct use of tongue scraper, in 1/21 for negative control rinse alone, and in 3/21 in the control and tongue scraping sequence. At day 14, significantly lower counts were identified only in the active rinse sequence (p < 0.001) for 15/78 species including, Fusobacterium sp., Porphyromonas gingivalis, Pseudomonas aeruginosa, Staphylococcus aureus, and Tannerella forsythia. A decrease in bacteria from baseline to day 14 was found in successfully treated subjects for 9/74 species including: P. gingivalis, Prevotella melaninogenica, S. aureus, and Treponema denticola. Baseline VSC scores were correlated with several bacterial species. The use of a tongue scraper combined with active rinse did not change the levels of VSC compared to rinsing alone. CONCLUSIONS VSC scores were not associated with bacterial counts in samples taken from the dorsum of the tongue. The active rinse alone containing zinc and chlorhexidine had effects on intra-oral halitosis and reduced bacterial counts of species associated with malodor. Tongue scraping provided no beneficial effects on the microbiota studied. CLINICAL RELEVANCE Periodontally healthy subjects with intra-oral halitosis benefit from daily rinsing with zinc- and chlorhexidine-containing mouth rinse.
Resumo:
The concept of platform switching has been introduced to implant dentistry based on clinical observations of reduced peri-implant crestal bone loss. However, published data are controversial, and most studies are limited to 12 months. The aim of the present randomized clinical trial was to test the hypothesis that platform switching has a positive impact on crestal bone-level changes after 3 years. Two implants with a diameter of 4 mm were inserted crestally in the posterior mandible of 25 patients. The intraindividual allocation of platform switching (3.3-mm platform) and the standard implant (4-mm platform) was randomized. After 3 months of submerged healing, single-tooth crowns were cemented. Patients were followed up at short intervals for monitoring of healing and oral hygiene. Statistical analysis for the influence of time and platform type on bone levels employed the Brunner-Langer model. At 3 years, the mean radiographic peri-implant bone loss was 0.69 ± 0.43 mm (platform switching) and 0.74 ± 0.57 mm (standard platform). The mean intraindividual difference was 0.05 ± 0.58 mm (95% confidence interval: -0.19, 0.29). Crestal bone-level alteration depended on time (p < .001) but not on platform type (p = .363). The present randomized clinical trial could not confirm the hypothesis of a reduced peri-implant crestal bone loss, when implants had been restored according to the concept of platform switching.
Resumo:
OBJECTIVES To report a 10-year single center experience with Amplatzer devices for left atrial appendage (LAA) occlusion. BACKGROUND Intermediate-term outcome data following LAA occlusion are scarce. METHODS Short- and intermediate-term outcomes of patients who underwent LAA occlusion were assessed. All procedures were performed under local aesthesia without transesophageal echocardiography. Patients were discharged on acetylsalicylic acid and clopidogrel for 1-6 months. RESULTS LAA occlusion was attempted in 152 patients (105 males, age 72 ± 10 years, CHA2 DS2 -Vasc-score 3.4 ± 1.7, HAS-BLED-score 2.4 ± 1.2). Nondedicated devices were used in 32 patients (21%, ND group) and dedicated Amplatzer Cardiac Plugs were used in 120 patients (79%, ACP group). A patent foramen ovale or atrial septal defect was used for left atrial access and closed at the end of LAA occlusion in 40 patients. The short-term safety endpoints (procedural complications, bleeds) occurred in 15 (9.8%) and the efficacy endpoints (death, stroke, systemic embolization) in 0 patients. Device embolization occurred more frequently in the ND as compared to the ACP group (5 patients or 12% vs. 2 patients or 2%). Mean intermediate-term follow up of the study population was 32 months (range 1-120). Late deaths occurred in 15 patients (5 cardiovascular, 7 noncardiac, 3 unexplained). Neurologic events occurred in 2, peripheral embolism in 1, and major bleeding in 4 patients. The composite efficacy and safety endpoint occurred in 7% and 12% of patients. CONCLUSION LAA closure may be a good alternative to oral anticoagulation. This hypothesis needs to be tested in a randomized clinical trial to ensure that all potential biases of this observational study are accounted for.
Resumo:
BACKGROUND The role of subsequent atrial tachycardias (AT) in the context of persistent atrial fibrillation (AF) remains undetermined. This study evaluated the prognostic role of subsequent ATs for arrhythmia recurrences after catheter ablation of persistent AF. METHODS AND RESULTS A total of 110 patients with persistent AF (63±9 years; 22 women; 61 long-lasting persistent AF) underwent pulmonary vein isolation followed by electrogram-guided ablation. After AF terminated to AT, patients were separated by the randomization protocol to receive either direct cardioversion (group A) or further ablation of subsequent ATs to sinus rhythm (group B). After a mean follow-up of 20.1±13.3 months after the first procedure, significantly more group B patients were in sinus rhythm as compared with patients in group A (30 [57%] versus 18 [34%]; P=0.02). Moreover, recurrences of AF were significantly less frequent of group B than in group A patients (10 [19%] versus 26 [49%]; P=0.001). After the last procedure (follow-up, 34.0±6.4 months), significantly more group B patients were free of AF as compared with patients of group A (49 [92%] versus 39 [74%]; P=0.01). The proportion of AT recurrences did not differ between the 2 groups after the first and final procedures. The strongest predictor for an arrhythmia-free survival after a single procedure was randomization to the procedural end point of termination to sinus rhythm by elimination of subsequent ATs (P=0.004). CONCLUSIONS Catheter ablation of subsequent ATs increases freedom from AF but not AT, suggesting a contributing role of subsequent ATs in the mechanisms of persistent AF. CLINICAL TRIAL REGISTRATION URL: http://www.clinicaltrials.gov. Unique identifier: NCT01896570.