974 resultados para Semiology pharmaceutical


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper describes a simple, portable and environmentally friendly method for the rapid determination of dipyrone in pharmaceuticals by using diffuse reflectance spectroscopy. The proposed method is based on the reflectance measurements of the orange compound produced from the spot test reaction between dipyrone and p-dimethylaminocinnamaldehyde (p-DAC), in acid medium, using a filter paper as solid support. Experimental design methodologies were used to optimize the measurement conditions. All reflectance measurements were carried out at 510 nm and the linear range was from 1.42 × 10-4-2.85 × 10-3 mol L-1, with a correlation coefficient of 0.999. The limit of detection (LOD) and the limit of quantification (LOQ) were 1.20 × 10-5 mol L-1 and 4.00 × 10-5 mol L-1, respectively. The intraday precision and interday precision were studied for 10 replicate analyses of 7.90 × 10-4 mol L-1 dipyrone solution. The coefficients of variation were 1.1 and 0.9%, respectively. The proposed method was applied successfully to the determination of dipyrone in commercial brands of pharmaceuticals. No interferences were observed from the common excipients in formulations. The results obtained by the proposed method were favorably compared with those given by the Brazilian Pharmacopoeia procedure at 95% confidence level. ©2007 Sociedade Brasileira de Química.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A simple analytical method for quantification of atenolol in pharmaceutical formulations by diffuse reflectance spectroscopy is described. The method is based on the reaction, on the filter paper surface, between the drug and p-chloranil producing a colored compound. The best reaction conditions were obtained with 20 μL of atenolol solution and 20 μL of p-chloranil. All reflectance measurements were carried out at 550 nm and the linear range was from 1.13×10-2 to 7.88×10-2 mol L-1 (r = 0.9992). The limit of detection was 2.80 × 10-3 mol L-1. The proposed method was successfully applied to analysis of different commercial brands of pharmaceutical formulations and the results obtained by the proposed method were in good agreement with those obtained using the British Pharmacopoeia method.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

X-ray computed tomography (CT) refers to the cross-sectional imaging of an object measuring the transmitted radiation at different directions. In this work, we describe a non-conventional application of computerized tomography: visualization and improvements in the understanding of some internal structural features of solid dosage forms. A micro-CT X-ray scanner, with a minimum resolution of 30 μm was used to characterize some pharmaceutical tablets, granules, controlled-release osmotic tablet and liquid-filled soft-gelatin capsules. The analysis presented in this work are essentially qualitative, but quantitative parameters, such as porosity, density distribution, tablets dimensions, etc. could also be obtained using the related CT techniques. © 2010 American Institute of Physics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The intension of this paper was to review and discuss some of the current quantitative analytical procedures which are used for quality control of pharmaceutical products. The selected papers were organized according to the analytical technique employed. Several techniques like ultraviolet/visible spectrophotometry, fluorimetry, titrimetry, electroanalytical techniques, chromatographic methods (thin-layer chromatography, gas chromatography and high-performance liquid chromatography), capillary electrophoresis and vibrational spectroscopies are the main techniques that have been used for the quantitative analysis of pharmaceutical compounds. In conclusion, although simple techniques such as UV/VIS spectrophotometry and TLC are still extensively employed, HPLC is the most popular instrumental technique used for the analysis of pharmaceuticals. Besides, a review of recent works in the area of pharmaceutical analysis showed a trend in the application of techniques increasingly rapid such as ultra performance liquid chromatography and the use of sensitive and specific detectors as mass spectrometers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A simple, rapid, accurate and inexpensive spectrophotometric method for the determination of tetracycline and doxycycline has been developed. The method is based on the reaction between these drugs and chloramine-T in alkaline medium producing red color products with absorbance maximum at the λ=535 and 525 nm for the tetracycline and doxycycline, respectively. The best conditions for the reactions have been found using multivariate method. Beer's law is obeyed in a concentration ranges 1. 03 x 10 -5 to 3. 61 x 10 4mol L -1 and 1. 75 x 10 -5 to 3. 48 x 10 4mol L -1 for the tetracycline and doxycycline, respectively. The quantification limits were 5. 63 x 10 -6 mol L -1 and 7. 12 x 10 -7 mol L -1 for the tetracycline and doxycycline, respectively. The proposed method was successfully applied to the determination of these drugs in pharmaceutical formulations and the results obtained were in good agreement with those obtained by the comparative method at the 95% confidence level.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Orbifloxacin is a fluoroquinolone with broad-spectrum antimicrobial activity, and belongs to the third generation of quinolones. Regarding the quality control of medicines, a validated microbiological assay for determination of orbifloxacin in pharmaceutical formulations has not as yet been reported. For this purpose, this paper reports the development and validation of a simple, sensitive, accurate and reproducible agar diffusion method to quantify orbifloxacin in tablet formulations. The assay is based on the inhibitory effect of orbifloxacin upon the strain of Staphylococcus aureus ATCC 25923 used as test microorganism. The results were treated statistically by analysis of variance and were found to be linear (r = 0.9992) in the selected range of 16.0-64.0 μg/mL, precise with relative standard deviation (RSD) of repeatability intraday = 2.88%, intermediate precision RSD = 3.33%, and accurate (100.31%). The results demonstrated the validity of the proposed bioassay, which allows reliable orbifloxacin quantitation in pharmaceutical samples and therefore can be used as a useful alternative methodology for the routine quality control of this medicine. © 2011 by the authors; licensee MDPI, Basel, Switzerland.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper describes a simple, environmentally friendly and rapid quantitative spot test procedure for the determination of captopril (CPT) in bulk drug and in pharmaceutical formulations by using diffuse reflectance spectroscopy. The proposed method is based on the reflectance measurements of the orange compound (λ max 490 nm) produced by the spot test reaction between CPT and p-chloranil (CL). Under optimal conditions, calibration curves were obtained for CPT by plotting the optical density of the reflectance signal (A R) vs. the log of the mol L -1 concentration, from 6.91×10 -3 to 1.17×10 -1, with a good coefficient of determination (R 2 = 0.9992). The common excipients used as additives in pharmaceuticals do not interfere in the proposed method. The method was applied to determine CPT in commercial pharmaceutical formulations. The results obtained by the proposed method are compared favorably with those obtained by an official procedure at 95% confidence level. The method validation results showed that the sensitivity and selectivity of the methods were adequated for drug monitoring in industrial quality control laboratories. © 2011 Moment Publication.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Includes bibliography

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Presenta las recomendaciones de la reunion en la que se trato el rol del CCCT en la promocion del intercambio de informacion, el estrechamiento de la asistencia tecnica entre los paises de la region, y el de aunar los esfuerzos de los cientificos en la busqueda de soluciones a los problemas comunes en el sector farmaceutico.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Descreve-se um eletrodo de carbono modificado com fosfato de cobre (II) imobilizado em uma resina de poliéster (Cu3(PO4)2-Poly) para a determinação de rutina em amostras farmacêuticas por voltametria de onda quadrada. O eletrodo modificado permite a determinação de rutina em potencial (0.20 V vs Ag / AgCl (3,0 mol L-1 KCl)) menor que o observado em um eletrodo não modificado. Verificou-se que a corrente de pico foi linear com a concentração de rutina na faixa de 9,9 × 10-8 a 2,5 × 10-6 mol L-1, com um limite de detecção de 1,2 × 10-8 mol L-1. A resposta do eletrodo foi estável, sem variação significativa dentro de várias horas de operação contínua. A morfologia da superfície do eletrodo modificado foi caracterizada por microscopia eletrônica de varredura (MEV) e pelo sistema de energia dispersiva de raios-X (EDX). Os resultados obtidos foram precisos e exatos. Ademais, estes resultados estão de acordo com aqueles obtidos pelo método cromatográfico a um nível de confiança de 95%.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Extracts of plants of the Sclerolobium genus are disclosed, as well as methods for preparing same and cosmetic and pharmaceutical formulations containing these extracts. These extracts can be obtained by polar and/or apolar extraction, each fraction containing different anti-oxidants, all of which are useful for topical treatment. Also disclosed is the use of this extract in cosmetic and/or pharmaceutical formulations for topical use.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: This article describes the application and the performance of a cheap, simple and portable device that can be used for colorimetric quantitative determination of captopril (CPT) in pharmaceutical preparations. Methods: The sensor is a light detector resistor (LDR) placed into a black PTFE cell and coupled to a low cost multimeter (Ohmmeter). The instrument has been tested and is easy and fast to use. The quantitative study is based mainly on reduction of ammonium molybdate by captopril, in the presence of sulphuric acid, producing a green-yellow compound (max 407 nm). The calibration curves were obtained by plotting the electric resistance of the LDR against the CPT concentration on the range of 4.60 x 10-4 to 1.84 x 10-3 mol l-1 with a good coefficient of determination (R2 = 0.9962). Results: Statistical analysis of the obtained results showed no significant difference between the proposed methodology and the official reported method as evident from the t-test and variance ratio at 95% confidence level. Conclusion: The results of this study demonstrate that the instrument can be used for simple, accurate, precise, fast, in situ and low-cost colorimetric analysis of captopril in pharmaceuticals products.