988 resultados para Scatter plot


Relevância:

20.00% 20.00%

Publicador:

Resumo:

"Materials for the history of the Popish plot": p. 405-411.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cover title.: Electronic computer program for flood record compilation and frequency plot (BPR program HY-5) Developed by: U. S. Dept. of Commerce, Bureau of Public Roads.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An approach reported recently by Alexandrov et al (2005 Int. J Imag. Syst. Technol. 14 253-8) on optical scatter imaging, termed digital Fourier microscopy (DFM), represents an adaptation of digital Fourier holography to selective imaging of biological matter. The holographic mode of the recording of the sample optical scatter enables reconstruction of the sample image. The form-factor of the sample constituents provides a basis for discrimination of these constituents implemented via flexible digital Fourier filtering at the post-processing stage. As in dark-field microscopy, the DFM image contrast appears to improve due to the suppressed optical scatter from extended sample structures. In this paper, we present the theoretical and experimental study of DFM using a biological phantom that contains polymorphic scatterers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Contemporary medicine has much to its credit, but has created an insatiable demand for new technologies and more health services, fed by commercial promotion, professional advocacy and sociopolitical pressure. Total health expenditure at the national level is now almost 10% of gross domestic product and is expected to top 16% by 2020. After recent inquiries into the failings of its public health system, the Queensland Government has committed itself to a 25% increase in expenditure on health over the next 5 years. But will it lead to better population health, and is it sustainable? The return-on-investment curve for modern health care may be flattening out, in an environment of growing numbers of older patients with chronic illnesses, maldistribution of services and hospital overcrowding. A change in thinking is required if current medical practice is to avoid imploding when confronted with the next major economic downturn. Health policy, service funding and clinical training must focus on critical appraisal of the effectiveness of health care technologies and the structure and financing of health care systems. Practising clinicians will be obliged to provide leadership in determining value for money in the choice of health care for specific patient populations and how that care is delivered.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Regular monitoring of wastewater characteristics is undertaken on most wastewater treatment plants. The data acquired during this process are usually filed and forgotten. However, systematic analysis of these data can provide useful insights into plant behaviour. Conventional graphical techniques are inadequate to give a good overall picture of how wastewater characteristics vary, with time and along the lagoon system. An approach based on the use of contour plots was devised that largely overcomes this problem. Superimposition of contour plots for different parameters can be used to gain a qualitative understanding of the nature and strength of relationships between the parameters. This is illustrated in an analysis of monitoring data for lagoon 115 East at the Western Treatment Plant, near Melbourne, Australia. In this illustrative analysis, relationships between ammonia removal rates and parameters such as chlorophyll a level and temperature are explored using a contour plot superimposition approach. It is concluded that this approach can help improve our understanding, not only of lagoon systems, but of other wastewater treatment systems as well.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This article describes a 6-yr study of the radial growth rates (RGR, mm yr-1) of Rhizocarpon section Rhizocarpon thalli on a talus slope at Snoqualmie Pass in the Cascade Range, Washington State, United States (47°27'N; 121°26'W). At the end of the growth period, 32 of a total of 39 thalli had exhibited a positive RGR, and 7 of a total of 39 thalli showed no measurable growth. Mean RGR of all thalli was 0.07 mm yr-1 (range, 0-0.19 mm, SD = 0.06). Analysis of variance suggested no significant variation in RGR in successive growth periods, but significant differences were present both within and between thalli. The slope of a boulder facet did not influence RGR, but growth was affected by aspect, the least growth being observed on north-northwest facets. A plot of RGR against thallus diameter revealed a wide scatter of data points with little evidence for a significant change in growth with thallus size. Hence, the study showed that the RGR of Rhizocarpon thalli at Snoqualmie is extremely slow and highly variable and significantly less than estimates based on lichenometry. To determine the growth curve of a yellow-green Rhizocarpon by direct measurement at such a site would require a large sample of thalli and careful standardization of the species studied, the aspect conditions under which the thalli were measured, and the initial hypothallus width of the thalli. © 2005 Regents of the University of Colorado.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In some experimental situations, the factors may not be equivalent to each other and replicates cannot be assigned at random to all treatment combinations. A common case, called a ‘split-plot design’, arises when one factor can be considered to be a major factor and the other a minor factor. Investigators need to be able to distinguish a split-plot design from a fully randomized design as it is a common mistake for researchers to analyse a split-plot design as if it were a fully randomised factorial experiment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background Yellow filters are sometimes recommended to people with low vision. Our aim was investigate the effects of three commercial yellow filters on visual acuity and contrast sensitivity (with and without glare) and reading (without glare) under conditions of forward light scatter (FLS). Method Fifty-five healthy subjects were assessed with Corning Photochromic Filters (CPFs) 450, 511 and 527 and a filter producing FLS. The effects on log MAR visual acuity, Pelli–Robson contrast sensitivity with and without glare, and reading (measured with MNRead charts) without glare were determined. Results Statistically significant differences were found between the overall effect of glare and between CPFs for visual acuity and contrast sensitivity. A gradual decline in visual acuity, contrast sensitivity and reading with increasing CPF absorption was noted. Conclusion Effects of CPF450, 511, 527 on visual acuity, contrast sensitivity and reading under conditions of FLS were negative but not clinically significant.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

By applying narrative theory to the party political texts emerging within the UK Labour Party after 2010, which make up the corpus of One Nation discourse, we can grasp the underlying significance of this ideational revision of Labour Party and leftist thought. Through an identification and analysis of the sequence of texts and their constitution as a "story" that interpolates an underlying "plot," we can see how a revision of Labour's "tale" offers to leadership a new party discourse appropriate to it, mediating-if not reconciling-the problematic duality of narrative authorship by both party and leader. © The Political Quarterly Publishing Co. Ltd. 2013.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To assess the impact of light scatter, similar to that introduced by cataract on retinal vessel blood oxygen saturation measurements using poly-bead solutions of varying concentrations. Eight healthy, young, non-smoking individuals were enrolled for this study. All subjects underwent digital blood pressure measurements, assessment of non-contact intraocular pressure, pupil dilation and retinal vessel oximetry using dual wavelength photography (Oximetry Module, Imedos Systems, Germany). To simulate light scatter, cells comprising a plastic collar and two plano lenses were filled with solutions of differing concentrations (0.001, 0.002 and 0.004%) of polystyrene microspheres (Polysciences Inc., USA). The adopted light scatter model showed an artifactual increase in venous optical density ratio (p=0.036), with the 0.004% condition producing significantly higher venous optical density ratio values when compared to images without a cell in place. Spectrophotometric analysis, and thus retinal vessel oximetry of the retinal vessels, is altered by artificial light scatter. © 2013 Elsevier Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Scatter in medical imaging is typically cast off as image-related noise that detracts from meaningful diagnosis. It is therefore typically rejected or removed from medical images. However, it has been found that every material, including cancerous tissue, has a unique X-ray coherent scatter signature that can be used to identify the material or tissue. Such scatter-based tissue-identification provides the advantage of locating and identifying particular materials over conventional anatomical imaging through X-ray radiography. A coded aperture X-ray coherent scatter spectral imaging system has been developed in our group to classify different tissue types based on their unique scatter signatures. Previous experiments using our prototype have demonstrated that the depth-resolved coherent scatter spectral imaging system (CACSSI) can discriminate healthy and cancerous tissue present in the path of a non-destructive x-ray beam. A key to the successful optimization of CACSSI as a clinical imaging method is to obtain anatomically accurate phantoms of the human body. This thesis describes the development and fabrication of 3D printed anatomical scatter phantoms of the breast and lung.

The purpose of this work is to accurately model different breast geometries using a tissue equivalent phantom, and to classify these tissues in a coherent x-ray scatter imaging system. Tissue-equivalent anatomical phantoms were designed to assess the capability of the CACSSI system to classify different types of breast tissue (adipose, fibroglandular, malignant). These phantoms were 3D printed based on DICOM data obtained from CT scans of prone breasts. The phantoms were tested through comparison of measured scatter signatures with those of adipose and fibroglandular tissue from literature. Tumors in the phantom were modeled using a variety of biological tissue including actual surgically excised benign and malignant tissue specimens. Lung based phantoms have also been printed for future testing. Our imaging system has been able to define the location and composition of the various materials in the phantom. These phantoms were used to characterize the CACSSI system in terms of beam width and imaging technique. The result of this work showed accurate modeling and characterization of the phantoms through comparison of the tissue-equivalent form factors to those from literature. The physical construction of the phantoms, based on actual patient anatomy, was validated using mammography and computed tomography to visually compare the clinical images to those of actual patient anatomy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study intends to validate the sensitivity and specificity of coded aperture coherent scatter spectral imaging (CACSSI) by comparison to clinical histological preparation and pathologic analysis methods currently used for the differentiation of normal and neoplastic breast tissues. A composite overlay of the CACSSI rendered image and pathologist interpreted, stained sections validate the ability of coherent scatter imaging to differentiate cancerous tissues from normal, healthy breast structures ex-vivo. Via comparison to the pathologist annotated slides, the CACSSI system may be further optimized to maximized sensitivity and specificity for differentiation of breast carcinomas.