962 resultados para Scanning reference electrode technique


Relevância:

30.00% 30.00%

Publicador:

Resumo:

This work presents a method to obtain B-scan images based on linear array scanning and 2R-SAFT. Using this technique some advantages are obtained: the ultrasonic system is very simple; it avoids the grating lobes formation, characteristic in conventional SAFT; and subaperture size and focussing lens (to compensate emission-reception) can be adapted dynamically to every image point. The proposed method has been experimentally tested in the inspection of CFRP samples. © 2010 American Institute of Physics.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Modified fluorcanasite glasses were fabricated by either altering the molar ratios of Na 2O and CaO or by adding P 2O 5 to the parent stoichiometric glass compositions. Glasses were converted to glass-ceramics by a controlled two-stage heat treatment process. Rods (2 mm x 4 mm) were produced using the conventional lost-wax casting technique. Osteoconductive 45S5 bioglass was used as a reference material. Biocompatibility and osteoconductivity were investigated by implantation into healing defects (2 mm) in the midshaft of rabbit femora. Tissue response was investigated using conventional histology and scanning electron microscopy. Histological and histomorphometric evaluation of specimens after 12 weeks implantation showed significantly more bone contact with the surface of 45S5 bioglass implants when compared with other test materials. When the bone contact for each material was compared between experimental time points, the Glass-Ceramic 2 (CaO rich) group showed significant difference (p = 0.027) at 4 weeks, but no direct contact at 12 weeks. Histology and backscattered electron photomicrographs showed that modified fluorcanasite glass-ceramic implants had greater osteoconductivity than the parent stoichiometric composition. Of the new materials, fluorcanasite glass-ceramic implants modified by the addition of P 2O 5 showed the greatest stimulation of new mineralized bone tissue formation adjacent to the implants after 4 and 12 weeks implantation. © 2010 Wiley Periodicals, Inc.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A new device for irrigation, which presents hydrodynamic activation based on the pressure-suction technology, has recently been introduced to the market: the Rinsendo system. This study compared the efficacy of the Rinsendo system and conventional (manualdynamic) irrigation in the removal of debris from the root canal walls, using scanning electron microscopy (SEM). Twenty mandibular premolars with completely formed roots were selected and randomly divided into group 1 (irrigation with the Rinsendo system) and group 2 (conventional irrigation). The canals were irrigated with 1 ml of saline at each change of instrument. instrumentation started with a #15 K file and continued up to a #40 K file, which was standardized as the working length instrument. Then, the teeth were sectioned in buccolingual direction and the halves were sputter-coated with gold and examined by SEM. The apical, middle and cervical root canal thirds were evaluated, and the results were analyzed statistically by the Mann-Whitney test for comparison between methods, Kruskal-Wallis test for comparison among thirds, and Miller test for individual comparisons. A significance level of 5% was set for all analyses. The results did not show significant differences (p>0.05) between methods at each third and among thirds for each technique analyzed individually. in conclusion, there was no difference in the cleaning ability of the Rinsendo system and conventional irrigation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Voltammetric analysis of amodiaquine using a hemin biosensor revealed a well-defined peak at 0.14 V (vs. Ag/AgCl), corresponding to the oxidation of amodiaquine at pH 7.0. The electrodic behavior indicated that the oxidation process was irreversible, and that it was controlled by diffusion. In addition to advantages such as high selectivity and sensitivity, the method developed could be used for the analysis of breast milk containing amodiaquine without any need for prior sample treatment, an important consideration in routine analysis laboratories. Measurements of the drug contained in breast milk were used to validate the technique. The detection limit for standard solutions was 3.30 mg L-1, and the quantification limit was 11.0 mg L-1. ©The Electrochemical Society.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A major UK initiative, entitled 'Mapping the Underworld', is seeking to address the serious social, environmental and economic consequences arising from an inability to locate the buried utility service infrastructure without resorting to extensive excavations. Mapping the Underworld aims to develop and prove the efficacy of a multi-sensor device for accurate remote buried utility service detection, location and, where possible, identification. One of the technologies to be incorporated in the device is low-frequency vibro-acoustics, and the application of this technology for detecting buried infrastructure is currently being investigated. Here, a shear wave ground vibration technique for detecting buried pipes is described. For this technique, shear waves are generated at the ground surface, and the resulting ground surface vibrations measured, using geophones, along a line traversing the anticipated run of the pipe. Measurements were made at a test site with a single pressurized polyethylene mains water pipe. Time-extended signals were employed to generate the illuminating wave. Cross-correlation functions between the measured ground velocities and a reference measurement adjacent to the excitation were then calculated and summed using a stacking method to generate a cross-sectional image of the ground. The wide cross-correlation peaks caused by high ground attenuation were partially compensated for by using a generalized cross-correlation function called the smoothed coherence transform. To mitigate the effects of other potential sources of vibration in the vicinity, the excitation signal was used as an additional reference when calculating the generalized cross-correlation functions. For two out of three tests, the pipe was detected, indicating that this technique will be a valuable addition to the Mapping the Underworld armoury.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A voltammetric method for the determination of ethyl acetate in ethanol fuel using a Fe3+/Nafion®-coated glassy carbon electrode (GCE) is proposed. The ethyl acetate present in the ethanol fuel was previously converted to acetohydroxamic acid via pretreatment with hydroxylamine chloride. The acetohydroxamic acid promptly reacted with the iron (III) present in the film, producing iron (III) acetohydroxamate, which presents a well-defined voltammetric peak current at -0.02 V. Optimization of the voltammetric parameters for the cyclic, linear sweep, square wave, and differential pulse modalities was carried out for this chemically-modified electrode. Square wave voltammetry afforded the best response for acetohydroxamic acid detection. The analytical curve for this species was linear from 9 to 100 μmol L 1 according to the following equation: ip (μA) = 0.27 + 2.55Cacetohydroxamic acid (μmol L 1), with linear correlation coefficient equal to 0.993. The technique presented limit of detection equal to 5.3 μmol L 1 and quantification limit of 17.6 μmol L 1. The proposed method was compared to the official method of ethyl acetate analysis (Gas Chromatography), and a satisfactory correlation was found between these techniques. © 2012 Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Correlative fractography is a new expression proposed here to describe a new method for the association between scanning electron microscopy (SEM) and light microscopy (LM) for the qualitative and quantitative analysis of fracture surfaces. This article presents a new method involving the fusion of one elevation map obtained by extended depth from focus reconstruction from LM with exactly the same area by SEM and associated techniques, as X-ray mapping. The true topographic information is perfectly associated to local fracture mechanisms with this new technique, presented here as an alternative to stereo-pair reconstruction for the investigation of fractured components. The great advantage of this technique resides in the possibility of combining any imaging methods associated with LM and SEM for the same observed field from fracture surface. © Microscopy Society of America 2013.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective To describe the technique of deep anterior lamellar keratoplasty (DALK) with Descemet's membrane (DM) exposure in horse eyes. Also, to compare the efficacy and safety of viscodissection and big-bubble techniques for DALK. Animals studied Thirty-four ex vivo horse eyes. Procedure Deep anterior lamellar keratoplasty was performed in 34 ex vivo horse eyes. Two groups (Group V - viscodissection - 2% sodium hyaluronate; Group A - air - big-bubble) of 17 eyes were studied. Other than the substance used, the surgical technique was similar for both groups. Nonperforated eyes were submitted for light microscopic histologic evaluation and scanning electron microscopic (SEM) analysis. Results Group V - Perforations occurred in 18% of the eyes during surgery. Light microscopy revealed exposure of DM in 28% of the eyes with mean thickness of the remaining stroma being 70.4μm. Group A - Perforations occurred in 42% of the eyes. Light microscopy revealed exposure of DM in 60% of the eyes with mean thickness of the remaining stroma being 23.3μm. No significant differences in safety, efficacy and thickness of the remaining stroma (including all eyes or excluding those with DM exposure) were observed. SEM of the surgical site revealed a more even surface in those eyes with DM exposure compared to eyes with thicker remaining stroma in both groups. Conclusions We describe two DALK techniques (viscodissection and big-bubble) for use in horses. No significant differences in safety, efficacy and thickness of the remaining stroma were observed. However, a nonsignificant trend toward the big-bubble technique being more efficacious but less safe was observed. © 2012 American College of Veterinary Ophthalmologists.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this study was to evaluate the effect of final irrigation protocols (17% EDTA, BioPure MTAD, SmearClear, and QMiX) on microhardness and erosion of root canal dentin. Fifty roots were sectioned transversely at the cement-enamel junction and each root was sectioned horizontally into 4-mm-thick slices. The samples were divided into five groups (n=10) according to the final irrigation protocol: G1: distilled water (control group); G2: 17% EDTA; G3: BioPure MTAD; G4: SmearClear; and G5: QMiX. The dentin microhardness was then measured with a load of 25 g for 10 s. Initially, the reference microhardness values were obtained for the samples without any etching. The same samples were then submitted to the final irrigation protocols. A new measure was realized and the difference between before and after the procedures was the dentin microhardness reduction. In sequence, the specimens were submitted to SEM analysis to verify the dentinal erosion. The Kruskal Wallis and Dunn tests (α=5%) were used to compare the results. The dentin microhardness decreased for all final irrigation protocols. There was no significant difference between groups 2, 3, 4, and 5 (P>0.05), but this groups presented significant dentin microhardness reduction than G1 (P<0.05). In G2, occurred the highest incidence of dentinal erosion (P<0.05). 17% EDTA, BioPure MTAD, SmearClear, and QMiX promoted significant dentin microhardness reduction. © 2013 Wiley Periodicals, Inc.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Pós-graduação em Química - IQ

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A new voltammetric method for the determination of Delta(9)-tetrahydrocannabinol (Delta(9)-THC) is described. The voltammetric experiments were accomplished in N-N dimethylformamide/water (9: 1, v/v), using tetrabutylammonium tetrafluoroborate (TBATFB) 0.1 mol/L as supporting electrolyte and a glassy carbon disk electrode as the working electrode. The anodic peak current was observed at 0.0 V (vs. Ag/AgCl) after a 30 s pre-concentration step under an applied potential of -1.2 V (vs. Ag/AgCl). A linear dependence of Delta(9)-THC detection was obtained in the concentration range 2.4-11.3 ng/mL, with a linear correlation coefficient of 0.999 and a detection limit of 0.34 ng/mL. The voltammetric method was used to measure the content of Delta(9)-THC in samples (hemp and hashish) confiscated by the police. The elimination of chemical interferences from the samples was promptly achieved through prior purification using the TLC technique, by employing methanol/water (4: 1, v/v) as the mobile phase. The results showed excellent correlation with results attained by HPLC.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Sugar is widely consumed worldwide and Brazil is the largest producer, consumer, and exporter of this product. To guarantee proper development and productivity of sugar cane crops, it is necessary to apply large quantities of agrochemicals, especially herbicides and pesticides. The herbicide tebuthiuron (TBH) prevents pre- and post-emergence of infesting weed in sugarcane cultures. Considering that it is important to ensure food safety for the population, this paper proposes a reliable method to analyse TBH in sugar matrixes (brown and crystal) using square wave voltammetry (SWV) and differential pulse voltammetry (DPV) at bare glassy carbon electrode and investigate the electrochemical behavior of this herbicide by cyclic voltammetry (CV). Our results suggest that TBH or the product of its reaction with a supporting electrolyte is oxidized through irreversible transfer of one electron between the analyte and the working electrode, at a potential close to +1.16 V vs. Ag |AgClsat in 0.10 mol L-1 KOH as supporting electrolyte solution. Both DPV and SWV are satisfactory for the quantitative analysis of the analyte. DPV is more sensitive and selective, with detection limits of 0.902, 0.815 and 0.578 mg kg-1, and quantification limits of 0.009, 0.010 and 0.008 mg kg-1 in the absence of the matrix and in the presence of crystal and brown sugar matrix, respectively. Repeatability lay between 0.53 and 13.8%, precision ranged between 4.14 and 15.0%, and recovery remained between 84.2 and 113% in the case of DPV conducted in the absence of matrix and in the presence of the crystal sugar matrix, respectively.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Úlcera neuropática é uma das sequei as mais estigmatizantes da hanseníase. Sua presença é bastante incapacitante para o indivíduo, podendo levar a deformação e/ou amputação do membro afetado. Diversas técnicas de tratamento têm sido utilizadas no manejo destas úlceras, no entanto, os resultados nem sempre são satisfatórios, ocasionando a existência de pessoas que convivem há vários anos com ferimentos crônicos. A laserterapia de baixa intensidade (LBI) tem sido utilizada em diversos países no tratamento de úlceras de difícil cicatrização, entretanto seus resultados são inconclusivos e muitos dos trabalhos publicados apresentam falhas metodológicas. O objetivo deste estudo foi avaliar o efeito da LBI sobre o processo de cicatrização de úlceras em pacientes hansenianos, em um teste clínico controlado e randomizado. O estudo foi realizado no ambulatório de curativos da Unidade de Referência Estadual em Dermatologia Sanitária do Pará - Marcello Candia, a partir de um levantamento clínico-epidemiológico para caracterização da população estudada, por meio de anamnese, identificação da localização das úlceras, registro fotográfico digital, avaliação da área das lesões utilizando o programa ImageTool 3.0, e medida da profundidade das úlceras de 51 pacientes, totalizando 97 lesões. A comorbidade mais frequente nesta população foi a hipertensão arterial sistêmica (13 casos). Em seguida, 25 sujeitos foram distribuídos aleatoriamente em dois grupos de estudo. O grupo controle (GC), formado por 12 pacientes (14 Úlceras) permaneceu recebendo o tratamento de rotina, composto por curativos simples diários, uso de sulfadiazina de prata 1 %, e orientações para autocuidados e prevenção de incapacidades. O grupo experimental (GE), formado por 13 sujeitos (17 úlceras), permaneceu recebendo o mesmo tratamento de rotina do GC mais a aplicação de LBI três vezes por semana, durante um período de 12 semanas. A LBI foi aplicada com um equipamento de laser diodo A1GaInP (660 nm), na dose de 2 J/cm² com a técnica de varredura sem contato no leito da lesão, e 4 J/ponto nas bordas da lesão com aplicações pontuais com contato. A densidade de potência foi de 1 W/cm². As variáveis estudadas foram: área da lesão em cm², profundidade em milímetros e escore PUSH. No GC a média da área das úlceras foi de 5,3 (±9.2) antes e 4,4 (± 8,5) depois do tratamento, a profundidade foi de 6,3 (± 5,4) antes e 5,4 (± 5.7) depois, o escore PUSH foi 9,7 (± 3,4) antes e 8,4 (± 5.3) depois. No GE a média da área das Úlceras foi de 4,2 (± 5,9) antes e 3,8 (± 5,7) depois do tratamento, a profundidade foi de 6.2 (± 5.1) antes e 4,1 (± 3,9) depois, o escore PUSH foi 9,6 (± 3,3) antes e 7,9 (± 5,3) depois. A análise estatística não evidenciou diferença significativa (p > 0,05) em nenhuma das variáveis estudadas antes e depois do tratamento. A LBI, dentro dos parâmetros utilizados neste estudo, não demonstrou benefícios adicionais para a cicatrização de úlceras em hansenianos. A diminuição do peso exercido sobre a área da lesão e o controle da pressão arterial são medidas importantes no manejo destas úlceras.