898 resultados para STAINLESS STEEL-316L


Relevância:

80.00% 80.00%

Publicador:

Resumo:

This present study aimed to investigate the fatigue life of unused (new) endodontic instruments made of NiTi with control memory by Coltene™ and subjected to the multi curvature of a mandibular first molar root canal. Additionally, the instrument‟s structural behaviour was analysed through non-linear finite element analysis (FEA). The fatigue life of twelve Hyflex™ CM files was assessed while were forced to adopt a stance with multiple radius of curvature, similar to the ones usually found in a mandibular first molar root canal; nine of them were subjected to Pecking motion, a relative movement of axial type. To achieve this, it was designed an experimental setup with the aim of timing the instruments until fracture while worked inside a stainless steel mandibular first molar model with relative axial motion to simulate the pecking motion. Additionally, the model‟s root canal multi-curvature was confirmed by radiography. The non-linear finite element analysis was conducted using the computer aided design software package SolidWorks™ Simulation, in order to define the imposed displacement required by the FEA, it was necessary to model an endodontic instrument with simplified geometry using SolidWorks™ and subsequently analyse the geometry of the root canal CAD model. The experimental results shown that the instruments subjected to pecking motion displayed higher fatigue life values and higher lengths of fractured tips than those with only rotational relative movement. The finite element non-linear analyses shown, for identical conditions, maximum values for the first principal stress lower than the yield strength of the material and those were located in similar positions to the instrument‟s fracture location determined by the experimental testing results.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Stents are rigid and perforated tubular structures, which are inserted into blood vessels in order to prevent or inhibit the constriction of blood flow, restoring the normal blood flow, when blood vessels are clogged, being used in 70% of angioplasties. These medical devices assume great importance in the treatment of cardiovascular diseases (CVD) which are the leading cause of death worldwide. In the European Union CVD account for 40% of deaths and assume an estimated annual cost of 196 billion euros[1]. Stents must possess certain requirements, in order to, adequately, perform its function, such as biocompatibility (so that its use does not c ause damage on the health of its user), mechanical strength, radiopacity (so that it is easy to view), longitudinal flexibility, ease of handling, corrosion resistance and having high strength and high radial expansion ability to recover. Stents can be made of different materials, but metals, particularly stainless steel, are the most common. However, metallic stents present several dRawbacks such as corrosion and restenosis, leading to health complications for the patient, or even death. In order to minimize these disadvantages, new materials, like fibrous materials, have been used [2]. Monofilaments present high potential for stents development because, in addition to its biocompatibility, these materials allow the application of various surface treatments, such as antibacterial coatings. Furthermore, monofilament exhibit excellent mechanical properties, like greater stiffness and good results when subjected to compression, tensile and bending forces, since these forces will be directly supported by the monofilament [3]. To minimize the reaction of the human body and Limit the adhesion of microorganisms to the stent surface, some coatings have been developed, including the use of novel metals with antimicrobial properties, like silver. The main objective of this study was the development of fibrous stents, incorporation of silver oxide nanocoating. For the development of the stent, polyester monofilaments with 0.27mm of diameter were used in braiding technology, with a mandrel diameter of 6mm and a braiding angle of 35⁰. The mechanical behaviour of the stent were evaluated by mechanical testing under longitudinal and radial compression, bending. The results of compressive strength tests are according with value from literature: 1.13 to 2.9 N for radial compression and 0. 16-5.28N to longitudinal compression. From literature is also possible to verify that stents must present 75% of unchanged diameter during the bending test and must possess a porosity between 70% and 80% [4]. The produced polyester stent presents values of 1.29N for radial compression, 0.23N for longitudinal compression, 80% of porosity and 85.5% of unchanged diameter, during bending tests. For the antibacterial functionalization, silver oxide nanocoatings were prepared, through reactive magnetron g, with an Ag target in an Ar +O2 atmosphere. In order to evaluate the nanostructure and morphology of the coatings, d ifferent technique s like X-ray diffraction (XRD), scanning electron microscopy (SEM) and and X- ray photoelectron spectroscopy (XPS were used. From the analyses of XRD it is possible to verify that the peaks corresponds to planes of Ag2 O and MATERIAIS 2015 Porto, 21-23 June, 2015 characterize a cubic phase. The presence of Ag2 O is corroborated by XPS spectrum, where it is possible to observe silver, not only, in oxide state, but a lso in mettalic state, and it is possible to verify the presence of silver clusters, confirmed by SEM analysis. Films’ roughness and topography, parameters influencing the wettability of the surface and microorganism adhesion, were measured by Atomic Force Microscopy (AFM), and it was observed that the roughness is very low (under 10 nm). Coatings’ hydrophobicity and surface tension parameters were determined by contact angle measurement, and it was verified the hydrophobic behavior of the coatings. For antibacterial tests were used Staphylococcus epidermidis strain (IE186) and Staphylococcus aureus(ATCC 6538), and halo inhibition zone tests were realized. Ag+release rates were studied by means of inductively coupled plasma mass spectrometry (ICP -MS). The obtained results suggest that silver oxide coatings do not modify significantly surface properties of the substrate, like hydrophobicity and roughness, and present antimicrobial properties for both bacteria used.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Dissertação de mestrado integrado em Engenharia Mecânica

Relevância:

80.00% 80.00%

Publicador:

Resumo:

OBJECTIVE: We determined the effects of losartan and PD 123319 (antagonists of the AT1 and AT2 angiotensin receptors, respectively), and [Sar¹, Ala8] ANG II (a relatively peptide antagonist of angiotensin receptors) injected into the paraventricular nucleus (PVN) on water and 3% NaCl intake, and the diuretic, natriuretic, and pressor effects induced by administration of angiotensin II (ANG II) into the medial septal area (MSA) of conscious rats. METHODS: Holtzman rats were used . Animals were anesthetized with tribromoethanol (20 mg) per 100 grams of body weight, ip. A stainless steel guide cannula was implanted into the MSA and PVN. All drugs were injected in 0.5-mul volumes for 10-15 seconds. Seven days after brain surgery, water and 3% NaCl intake, urine and sodium excretion, and arterial blood pressure were measured. RESULTS: Losartan (40 nmol) and [Sar¹, Ala8] ANG II (40 nmol) completely eliminated whereas PD 123319 (40 nmol) partially blocked the increase in water and sodium intake and the increase in arterial blood pressure induced by ANG II (10 nmol) injected into the MSA. The PVN administration of PD 123319 and [Sar¹, Ala8] ANG II blocked whereas losartan attenuated the diuresis and natriuresis induced by MSA administration of ANG II. CONCLUSION: MSA involvement with PVN on water and sodium homeostasis and arterial pressure modulation utilizing ANGII receptors is suggested.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

La deformación plástica puede inducir a la transformación de la austenita a martensita en los aceros inoxidables austeníticos metaestables. Para analizar este hecho, el inoxidable austenítico metaestable grado AISI 301 LN fue estudiado en dos condiciones diferentes: recocido y laminado en frío. En el primer caso, el acero era completamente austenítico, mientras que después de la laminación presentaba un importante porcentaje de α’-martensita. Se evaluó el cambio de fase cuando el acero es sometido a ensayos monotónicos y cíclicos, así como cuando ha sido modificada la superficie mediante el granallado o se han realizado tratamientos térmicos de reversión. Se utilizaron diferentes técnicas de caracterización microestructural para detectar y cuantificar la martensita, como microscopía óptica, difracción de rayos-X (DRX) y difracción de electrones retrodispersados (EBSD); como también de caracterización mecánica para evaluar el comportamiento de los aceros, trabajo esencial de fractura (TEF), conformabilidad, fatiga de alto número de ciclos (HCF) y nanoindentación. Los resultados mostraron un incremento en la resistencia mecánica del acero laminado en comparación al acero recocido; este hecho está relacionado con la presencia de martensita originada por la laminación. Sin embargo, en términos de deformación y endurecimiento el acero recocido presenta un mejor desempeño como consecuencia del elevado porcentaje de fase austenítica. Así mismo, revertir la martensita de laminación a austenita y refinar la austenita presente permite obtener un acero con una propiedades mecánicas similares a cuando esta en la condición laminado.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A simple wipe sampling procedure was developed for the surface contamination determination of ten cytotoxic drugs: cytarabine, gemcitabine, methotrexate, etoposide phosphate, cyclophosphamide, ifosfamide, irinotecan, doxorubicin, epirubicin and vincristine. Wiping was performed using Whatman filter paper on different surfaces such as stainless steel, polypropylene, polystyrol, glass, latex gloves, computer mouse and coated paperboard. Wiping and desorption procedures were investigated: The same solution containing 20% acetonitrile and 0.1% formic acid in water gave the best results. After ultrasonic desorption and then centrifugation, samples were analysed by a validated liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS) in selected reaction monitoring mode. The whole analytical strategy from wipe sampling to LC-MS/MS analysis was evaluated to determine quantitative performance. The lowest limit of quantification of 10 ng per wiping sample (i.e. 0.1 ng cm(-2)) was determined for the ten investigated cytotoxic drugs. Relative standard deviation for intermediate precision was always inferior to 20%. As recovery was dependent on the tested surface for each drug, a correction factor was determined and applied for real samples. The method was then successfully applied at the cytotoxic production unit of the Geneva University Hospitals pharmacy.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Objective: The NALP3 inflammasome functions as a sensor of danger signals and triggers processing and release of IL-1b. Mutations of NALP3 are responsible for the cryopyrin associated periodic syndromes, a group of autoinflammatory disorders that respond to IL1 inhibition. Genetic studies have also linked NALP3 to hypertension in man, but the mechanism is not understood. The aim of this study is to investigate the role of NAPL3 inflammasome in the development of hypertension in an animal model. Design and Method: Six-week old male WT and NALP3 KO mice were used for generating a two-kidney, one clip (2K1C) renovascular hypertension. A U-shaped stainless steel clip (O^ ¼0.12mm) was placed on left renal artery under anaesthesia. The same surgery without clipping was performed in sham mice. At week 6 and 12 after the clipping, intra-arterial blood pressure (BP) was measured in conscious mice. Blood was collected for plasma renin analysis. Heart and kidney were excised and stored for molecular and morphological examinations. n¼5-6 mice per group. Data are mean_SEM. Results: Mean BP was significantly increased at week 6 and 12 in WT-2K1C mice compared to WT-sham group (MBPweek6: 138_2 vs.124_3 mmHg, p<0.01 and MBPweek12: 141_5 vs.122_3 mmHg, p<0.01) followed with an significant increase in heart weight (HW) and a decrease in clipped kidney weight indices in WT-2K1C mice compared to the WT-sham (HW/ BWweek6: 4.65_0.04 vs. 3.99_0.12 mg/g, p<0.001 and HW/BWweek12: 4.94_0.15 vs. 4.22_0.12 mg/g, p<0.001). Interestingly, NALP3 KO-2K1C mice did not develop hypertension. The MBP of KO-2K1C mice was comparable to the KO-sham (MBPweek6: 122_3 vs. 119_3 mmHg, p>0.05 and MBPweek6: 128_5 vs.122_4 mmHg, p>0.05). There was also no significant change in heart and kidney weight indices between KO- 2K1C and KO-sham mice. Conclusion: The preliminary results suggest that absence of NALP3 protects mice from the development of renin-dependent hypertension. Further molecular and morphological examinations are ongoing for the confirmation and mechanism explanation.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

BACKGROUND: Coronary in-stent restenosis cannot be directly assessed by magnetic resonance angiography (MRA) because of the local signal void of currently used stainless steel stents. The aim of this study was to investigate the potential of a new, dedicated, coronary MR imaging (MRI) stent for artifact-free, coronary MRA and in-stent lumen and vessel wall visualization. METHODS AND RESULTS: Fifteen prototype stents were deployed in coronary arteries of 15 healthy swine and investigated with a double-oblique, navigator-gated, free-breathing, T2-prepared, 3D cartesian gradient-echo sequence; a T2-prepared, 3D spiral gradient-echo sequence; and a T2-prepared, 3D steady-state, free-precession coronary MRA sequence. Furthermore, black-blood vessel wall imaging by a dual-inversion-recovery, turbo spin-echo sequence was performed. Artifacts of the stented vessel segment and signal intensities of the coronary vessel lumen inside and outside the stent were assessed. With all investigated sequences, the vessel lumen and wall could be visualized without artifacts, including the stented vessel segment. No signal intensity alterations inside the stent when compared with the vessel lumen outside the stent were found. CONCLUSIONS: The new, coronary MRI stent allows for completely artifact-free coronary MRA and vessel wall imaging.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Les empreses sempre han buscat com optimitzar el màxim els seus recursos i ser més eficients a la hora de realitzar les tasques que li han estat encomanades. És per aquest motiu que constantment les empreses realitzen estudis i valoracions de com poder millorar dia a dia. Aquest fet no és diferenciador a l’empresa Serralleria i Alumini Vilaró (S.A.V), que dia a dia estudia com optimitzar els seus processos o de vegades introduir-ne de nous per tal d’expandir la seva oferta de serveis. L’empresa és dedica a la fabricació de peces metàl•liques el procés ja sigui només de tall i mecanitzat, plegat, soldadura, acabats en inoxidable, pintura i fins i tot embalatge pel que fa a la part productiva, respecte a la part d’oficina tècnica també ofereix serveis de desenvolupament de productes segons especificacions del client i reenginyeria de qualsevol producte, analitzant la part que és vol millorar. En l’actualitat l’empresa ha detectat una mancança que creu que es podria solucionar, el problema és que l’empresa disposa de varies màquines de tall, entre les quals hi ha una màquina de tall làser i el problema principal és que la càrrega de les planxes del calaix de magatzem a la bancada de la màquina es realitza o bé manualment o a través d’un gripper sostingut al pont grua, depenent del pes de la planxa a transportar. L’objectiu principal d’aquest treball és fer el disseny d’una màquina que permeti automatitzar el procés de transportar la planxa metàl•lica del calaix de magatzem dipositat sobre una taula mòbil a la bancada de la màquina de tall. El disseny que pretenem fer és complet començant per fer un disseny estructural de la màquina més els seus respectius càlculs, moviments que volem aconseguir, tria de components ( motors, sensors ...), elaboració d’un pressupost per poder fer una estimació i finalment la elaboració del programa de control de tota la màquina més la interacció amb la màquina a través d’una pantalla tàctil. Es a dir, el que pretenem és realitzar un projecte que puguem fabricar en la realitat utilitzant tota la informació continguda dins del mateix

Relevância:

80.00% 80.00%

Publicador:

Resumo:

We present structural and electrical properties for p- and n-type layers grown close to the transition between a-Si:H and nc-Si:H onto different substrates: Corning 1737 glass, ZnO:Al-coated glass and stainless steel. Structural properties were observed to depend on the substrate properties for samples grown under the same deposition conditions. Different behaviour was observed for n- and p-type material. Stainless steel seemed to enhance crystallinity when dealing with n-type layers, whereas an increased crystalline fraction was obtained on glass for p-type samples. Electrical conduction in the direction perpendicular to the substrate seemed to be mainly determined by the interfaces or by the existence of an amorphous incubation layer that might determine the electrical behaviour. In the direction perpendicular to the substrate, n-type layers exhibited a lower resistance value than p-type ones, showing better contact properties between the layer and the substrate.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A radiochemical procedure was developed for the sequential determination of Pu and Am radioisotopes in environmental samples. The radioisotope activities were then used to assess the origin and release date of the environmental plutonium. The radioanalytical procedure is based on the separation of Pu and Am on selective extraction chromatographic resins (Eichrom TEVA and DGA). Alpha sources were prepared by electrodeposition on stainless steel discs, and the alpha emitting radionuclides (238Pu, 239,240Pu and 241Am) were measured by alpha spectrometry. For the determination of the beta emitting 241Pu, the Pu alpha source was leached in hot concentrated nitric acid and the Pu fraction further purified by extraction chromatography on a small column of TEVA resin (100 μg of resin in a pipette tip). 241Pu is then measured by ultra low level liquid scintillation counting. Due to the lack of reference material for 241Pu, the proposed radiochemical method was nevertheless validated using four IAEA reference sediments with information values of 241Pu. The proposed method was then used to determine the 238Pu, 239,240Pu, 241Pu and 241Am activity concentrations in alpine soils of France and Switzerland. The soil is the primary receptor of the atmospheric radioactive fallout and, because of the strong binding interaction with soils particles, the isotopes are little fractionated. Therefore, the activity ratios 241Pu/239+240Pu and 238Pu/239,240Pu in soil samples were used to determine the origin (source) and date of the Pu contamination in the investigated alpine sites. The 241Pu/239,240Pu and 238Pu/239,240Pu activity ratios confirmed that the main origin of Pu in the alpine soils was the global fallout from the nuclear bomb tests (NBT) in the fifties and sixties. Furthermore, the 241Pu/241Am activity ratios were used to determine the age of the Pu contamination, which is also an important data for distinguishing the Pu sources. The estimation of the date of the contamination, by the 241Pu/241Am age-dating method, further confirmed the NBT as the Pu source. However, the 241Pu/241Am dating method was limited to samples where Pu-Am fractionation was insignificant. If any, the contribution of the Chernobyl accident in the studied sites is negligible.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Oxalic and oxamic acids are the ultimate and more persistent by-products of the degradation of N-aromatics by electrochemical advanced oxidation processes (EAOPs). In this paper, the kinetics and oxidative paths of these acids have been studied for several EAOPs using a boron-doped diamond (BDD) anode and a stainless steel or an air-diffusion cathode. Anodic oxidation (AO-BDD) in the presence of Fe2+ (AO-BDD-Fe2+) and under UVA irradiation (AO-BDD-Fe2+-UVA), along with electro-Fenton (EF-BDD), was tested. The oxidation of both acids and their iron complexes on BDD was clarified by cyclic voltammetry. AO-BDD allowed the overall mineralization of oxalic acid, but oxamic acid was removed much more slowly. Each acid underwent a similar decay in AO-BDD-Fe2+ and EFBDD, as expected if its iron complexes were not attacked by hydroxyl radicals in the bulk. The faster and total mineralization of both acids was achieved in AO-BDD-Fe2+-UVA due to the high photoactivity of their Fe(III) complexes that were continuously regenerated by oxidation of their Fe(II) complexes. Oxamic acid always released a larger proportion of NH4 + than NO3- ion, as well as volatile NOx species. Both acids were independently oxidized at the anode in AO-BDD, but in AO-BDD-Fe2+-UVA oxamic acid was more slowlydegraded as its content decreased, without significant effect on oxalic acid decay. The increase in current density enhanced the oxidation power of the latter method, with loss of efficiency. High Fe2+ contents inhibited the oxidation of Fe(II) complexes by the competitive oxidation of Fe2+ to Fe3+. Low current densities and Fe2+ contents are preferable to remove more efficiently these acids by the most potent AO-BDD-Fe2+-UVA method.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The purpose of the study was to evaluate the shear bond strength of stainless steel orthodontic brackets directly bonded to extracted human premolar teeth. Fifty teeth were randomly divided into ¿ve groups: (1) System One (chemically cured composite resin), (2) Light Bond (light-cured composite resin), (3) Vivaglass Cem (self-curing glass ionomer cement), (4) Fuji Ortho LC (light-cured glass ionomer cement) used after 37% orthophosphoric acid¿etching of enamel (5) Fuji Ortho LC without orthophosphoric acid¿etching. The brackets were placed on the buccal and lingual surfaces of each tooth, and the specimens were stored in distilled water (24 hours) at 378C and thermocycled. Teeth were mounted on acrylic block frames, and brackets were debonded using an Instron machine. Shear bond strength values at fracture (Nw)were recorded. ANOVA and Student-Newman-Keuls multiple comparison tests were performed (P , .05). Bonding failure site was recorded by stereomicroscope and analyzed by Chi-square test, selected specimens of each group were observed by scanning electron microscope. System One attained the highest bond strength. Light Bond and Fuji Ortho LC, when using an acid-etching technique, obtained bond strengths that were within the range of estimated bond strength values for successful clinical bonding. Fuji Ortho LC and Vivaglass Cem left an almost clean enamel surface after debracketing.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

New methodologies for the analysis of volatile compoundsusing needle traps. Applications to breath, atmospheric andwater analysis. A new preconcentration technique has been developed for the analysis of volatile compounds based on the use of needle traps. These traps are based on stainless steel needles filled with one or more adsorbents, which allows the preconcentration of the anilities inside the trap by passing a gas flow through the needle. The parameters affecting the sorption/desorption process have been assessed (e.g. needle and liner dimensions, injector temperature, split less time, memory effects, and stability inside the needle). For liquid samples, four different sampling methodologies were studied, including passive and active sampling methods. The best results, considering the simplicity and sensitivity, are obtained by sampling the headspace volume using various cycles of a small and fix volume. Once the best conditions of analysis have been found, the method has been validated for gas and liquid samples. The results obtained show that needle traps are a good analytical methodology for the analysis of breath, environmental and liquid samples

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Transverse joints are placed in portland cement concrete pavements to control the development of random cracking due to stresses induced by moisture and thermal gradients and restrained slab movement. These joints are strengthened through the use of load transfer devices, typically dowel bars, designed to transfer load across the joint from one pavement slab to the next. Epoxy coated steel bars are the materials of choice at the present time, but have experienced some difficulties with resistance to corrosion from deicing salts. The research project investigated the use of alternative materials, dowel size and spacing to determine the benefits and limitations of each material. In this project two types of fiber composite materials, stainless steel solid dowels and epoxy coated dowels were tested for five years in side by side installation in a portion of U.S. 65 near Des Moines, Iowa, between 1997 and 2002. The work was directed at analyzing the load transfer characteristics of 8-in. vs. 12-in. spacing of the dowels and the alternative dowel materials, fiber composite (1.5- and 1.88-in. diameter) and stainless steel (1.5-in. diameter), compared to typical 1.5-in. diameter epoxy-coated steel dowels placed on 12-in. spacing. Data were collected biannually within each series of joints and variables in terms of load transfer in each lane (outer wheel path), visual distress, joint openings, and faulting in each wheel path. After five years of performance the following observations were made from the data collected. Each of the dowel materials is performing equally in terms of load transfer, joint movement and faulting. Stainless steel dowels are providing load transfer performance equal to or greater than epoxy-coated steel dowels at the end of five years. Fiber reinforced polymer (FRP) dowels of the sizes and materials tested should be spaced no greater than 8 in. apart to achieve comparable performance to epoxy coated dowels. No evidence of deterioration due to road salts was identified on any of the products tested. The relatively high cost of stainless steel solid and FRP dowels was a limitation at the time of this study conclusion. Work is continuing with the subject materials in laboratory studies to determine the proper shape, spacing, chemical composition and testing specification to make the FRP and stainless (clad or solid) dowels a viable alternative joint load transfer material for long lasting portland cement concrete pavements.