985 resultados para Respiratory system
Resumo:
Aflatoxin B1 (AFB1) has been recognized to cause cancer in the humans liver. Epidemiological and laboratory evidence also point towards the respiratory system as target for carcinogenesis. Exposure occurs mainly through food chain but inhalation represent an additional route of exposure. Agricultural workers have the greatest risk of occupational exposure due to their exposition to airborne aflatoxin through inhalation of dust.
Resumo:
Aflatoxin B1 (AFB1) has been recognized to produce cancer in human liver. In addition, epidemiological and laboratory studies demonstrated that the respiratory system was a target for AFB1. Exposure occurs predominantly through the food chain, but inhalation represents an additional route of exposure. The present study aimed to examine AFB1 exposure among poultry workers in Portugal. Blood samples were collected from a total of 31 poultry workers from six poultry farms. In addition, a control group (n = 30) was included comprised of workers who undertook administrative tasks. Measurement of AFB1 in serum was performed by enzyme-linked immunosorbent assay (ELISA). For examining fungi contamination, air samples were collected through an impaction method. Air sampling was obtained in pavilion interior and outside the premises, since this was the place regarded as the reference location. Using molecular methods, toxicogenic strains (aflatoxin-producing) were investigated within the group of species belonging to Aspergillus flavus complex. Eighteen poultry workers (59%) had detectable levels of AFB1 with values ranging from <1 ng/ml to4.23 ng/ml and with a mean value of 2 ± 0.98ng/ml. AFB1 was not detected in the serum sampled from any of the controls. Aspergillus flavus was the fungal species third most frequently found in the indoor air samples analyzed (7.2%) and was the most frequently isolated species in air samples containing only Aspergillus genus (74.5%). The presence of aflatoxigenic strains was only confirmed in outdoor air samples from one of the units, indicating the presence of a source inside the building in at least one case. Data indicate that AFB1 inhalation represents an additional risk in this occupational setting that needs to be recognized, assessed, and prevented.
Resumo:
Dust is a complex mixture of particles of organic and inorganic origin and different gases absorbed in aerosol droplets. In a poultry unit include dried faecal matter and urine, skin flakes, ammonia, carbon dioxide, pollens, feed and litter particles, feathers, grain mites, fungi spores, bacteria, viruses and their constituents. Dust particles vary in size and differentiation between particle size fractions is important in health studies in order to quantify penetration within the respiratory system. A descriptive study was developed in order to assess exposure to particles in a poultry unit during different operations, namely routine examination and floor turn over. Direct-reading equipment was used (Lighthouse, model 3016 IAQ). Particle measurement was performed in 5 different sizes (PM0.5; PM1.0; PM2.5; PM5.0; PM10). The chemical composition of poultry litter was also determined by neutron activation analysis. Normally, the litter of poultry pavilions is turned over weekly and it was during this operation that the higher exposure of particles was observed. In all the tasks considered PM5.0 and PM10.0 were the sizes with higher concentrations values. PM10 is what turns out to have higher values and PM0.5 the lowest values. The chemical element with the highest concentration was Mg (5.7E6 mg.kg-1), followed by K (1.5E4 mg.kg-1), Ca (4.8E3 mg.kg-1), Na (1.7E3 mg.kg-1), Fe (2.1E2 mg.kg-1) and Zn (4.2E1 mg.kg-1). This high presence of particles in the respirable range (<5–7μm) means that poultry dust particles can penetrate into the gas exchange region of the lung. Larger particles (PM10) present a range of concentrations from 5.3E5 and 3.0E6 mg/m3.
Resumo:
Mestrado em Engenharia Química
Resumo:
The self similar branching arrangement of the airways makes the respiratory system an ideal candidate for the application of fractional calculus theory. The fractal geometry is typically characterized by a recurrent structure. This study investigates the identification of a model for the respiratory tree by means of its electrical equivalent based on intrinsic morphology. Measurements were obtained from seven volunteers, in terms of their respiratory impedance by means of its complex representation for frequencies below 5 Hz. A parametric modeling is then applied to the complex valued data points. Since at low-frequency range the inertance is negligible, each airway branch is modeled by using gamma cell resistance and capacitance, the latter having a fractional-order constant phase element (CPE), which is identified from measurements. In addition, the complex impedance is also approximated by means of a model consisting of a lumped series resistance and a lumped fractional-order capacitance. The results reveal that both models characterize the data well, whereas the averaged CPE values are supraunitary and subunitary for the ladder network and the lumped model, respectively.
Resumo:
Introduction: Lower Respiratory Tract Infections (LRTIs) are highly prevalent in institutionalised people with dementia, constituting an important cause of morbidity and mortality. Computerised auscultation of Adventitious Lung Sounds (ALS) has shown to be objective and reliable to assess and monitor respiratory diseases, however its application in people with dementia is unknown. Aim: This study characterised ALS (crackles and wheezes) in institutionalised people with dementia. Methods: An exploratory descriptive study, including 6 long-term care institutions was conducted. The sample included a dementia group (DG) of 30 people with dementia and a match healthy group (HG) of 30 elderly people. Socio-demographic and anthropometric data, cognition, type and severity of dementia, cardio-respiratory parameters, balance, mobility and activities and participation were collected. Lung sounds were recorded with a digital stethoscope following Computerised Respiratory Sound Analysis (CORSA) guidelines. Crackles’ location, number (N), frequency (F), two-cycle duration (2CD), initial deflection width (IDW) and largest deflection width (LDW) and wheezes’ number (N), ratio (R) and frequency (F) were analysed per breathing phase. Statistical analyses were performed using PASW Statistics(v.19). Results: There were no significant differences between the two groups in relation to the mean N of crackles during inspiration and expiration in both trachea and thorax. DG trachea crackles had significant higher F during inspiration and lower IDW, 2CD and LDW during expiration when compared with HG. At the thorax, the LDW during inspiration was also significantly lower in the DG. A significant higher N of inspiratory wheezes was found in the HG. Both groups had a low ratio of high frequency wheezes. Conclusion: Computerised analyses of ALS informed on the respiratory system and function of people with dementia and elderly people. Hence, this could be the step towards prevention, early diagnosis and continuous monitoring of respiratory diseases in people with cognitive impairment.
Resumo:
Inhalation injuries are currently the factor most responsible for mortality in thermally injured patients. Inhalation injuries may occur independently, but generally occur together with skin burn. Smoke inhalation affects all levels of the respiratory system and the extent of the inhalation injury depends on the duration, exposure, amount and toxicity of the fume temperature, concentration and solubility of toxic gases, the occurrence of the accident in a closed space and pre-existing diseases. Smoke inhalation also induces changes in the systemic organs with the need for more fluid for resuscitation. Systemic vasoconstriction, with an elevation in systemic vascular resistance, a fall in myocardial contractility and a great increase in lymphatic flow in soft tissue are the most important changes in systemic organs. On admission of a burn patient there is a high suspicion of inhalation injury when there are signs and symptoms such as hoarseness, strides, dyspnea, carbonaceous sputum, anxiety or disorientation, with or without face burns. The patient with these findings has partial airway obstruction and there is substantial risk complete airway obstruction occurring of secondary to the edema. Patients with suspected inhalation injury should be intubated so as to maintain airway patency and avoid a total obstruction. This group of patients frequently develop respiratory failure with the need for mechanical ventilatory support. Nosocomial infections, sepsis and multiple organ system failure may occur. Late complications of inhalation injury are tracheitis, tracheal stenosis or tracheomalacia and chronic airway disease, which is relatively rare. Early diagnosis of inhalation injury and treatment in a Burn Unit by a group of highly motivated clinicians and a good team of nurses is essential in order to decrease the morbidity and mortality related to inhalation injury.
Resumo:
RESUMO: Relevância e Objectivos: O objectivo deste estudo consistiu em verificar a eficácia e segurança de uma técnica de higiene brônquica – Active Cycle breathing technique (ACBT), na remoção de secreções e desinsuflação em crianças asmáticas. É uma técnica recente, que ainda não foi estudada nesta população. Metodologia: A amostra foi constituída por um total de 14 crianças, com idades compreendidas entre os 6 e 18 anos, com o diagnóstico de asma. Foi dividida em dois grupos: grupo de controlo, constituído por asmáticos estáveis e grupo experimental constituído por asmáticos pós-crise. Ambos receberam o mesmo tratamento, que consistiu numa única sessão de ACBT. Realizaram um exame da função respiratória (variáveis FEV1, PEF, MEF75%, RV e FRC) antes e após a aplicação da técnica. Mediu-se a Saturação de O2 antes, a meio e no fim da aplicação da técnica. Por último, pesaram-se as secreções recolhidas durante a sessão de tratamento. Resultados: Como resultados, quando omparamos o antes e após aplicação do ACBT, obtivemos diferenças significativas no RV (p <0,05) e FRC (p <0,05); muito significativa na Sa02 (p <0,01) e peso de secreções, nos asmáticos pós crise. Ocorreu uma melhoria significativa da saturação (p <0,05) em asmáticos estáveis, não havendo secreções. Não houve efeitos adversos nem broncoespasmo em ambos os grupos.Conclusão: O ACBT é uma técnica que promove a remoção de secreções e diminuição da insuflação na população de asmáticos.--------------------ABSTRACT:Relevance and Goals: the goal of this study was to verify the efficiency and security of a bronchial hygienic technique - Active Cycle Breathing Technique (ACBT) – in the obstruction and insufflation of asthmatic children. This is a new technique that has not yet been studied in this population. Procedures: The subjects were 14 children aged between 6 and 18 years old with asthma diagnosis. They were divided in two groups: the control group with stable asthmatics and the experimental group with post-crisis asthmatics. Both received the same treatment that was a single session of ACBT. They made a lung function test before and after the application of the technique (variables FEV1, PEF, MEF75%, RV and FRC). The level of O2 saturation was measured before, during and after the procedure. In the end, the secretions collected during the treatment were weighted. Results: We observed a significant difference on RV (p ˂0,05), FRC (p ˂0,05), Sa02 (p ˂0,01) and in the weight of the secretions in the post-crisis asthmatics after ACBT. There was a significant improvement of saturation (p ˂0,05) only in the stable asthmatics. There were no adverse effects or bronchospasm in both groups.
Resumo:
We present a case of central nervous system (CNS) infection by a member of the Penicillium genera in a HIV-negative man in Brazil. The patient was admitted complaining of loss of visual fields and speech disturbances. CT scan revealed multiple brain abscesses. Stereothacic biopsies revealed fungal infection and amphotericin B treatment begun with initial improvement. The patient died few days later as a consequence of massive gastrointestinal bleeding due to ruptured esophageal varices. The necropsy and final microbiologic analyses disclosed infection by Penicillium sp. There are thousands of fungal species of the Penicillium genera. Systemic penicilliosis is caused by the P. marneffei and was formerly a rare disease, but now is one of the most common opportunistic infection of AIDS patients in Southeast Asia. The clinical presentation usually involves the respiratory system and the skin, besides general symptoms like fever and weight loss. Penicillium spp infection caused by species other than P. marneffei normally cause only superficial or allergic disease but rare cases of invasive disease do occur. We report the fourth case of Penicillium spp CNS infection.
Resumo:
Connective tissue diseases (CTDs) comprise several immunologic systemic disorders, each of which associated with a particular set of clinical manifestations and autoimmune profile. CTDs may cause numerous thoracic abnormalities, which vary in frequency and pattern according to the underlying disorder. The CTDs that most commonly involve the respiratory system are progressive systemic sclerosis, systemic lupus erythematosus, rheumatoid arthritis, Sjögren syndrome, polymyositis, dermatomyositis, and mixed connective tissue disease. Pulmonary abnormalities in this group of patients may result from CTD-related lung disease or treatment complications, namely drug toxicity and opportunistic infections. The most important thoracic manifestations of CTDs are interstitial lung disease and pulmonary arterial hypertension, with nonspecific interstitial pneumonia being the most common pattern of interstitial lung disease. High-resolution computed tomography is a valuable tool in the initial evaluation and follow-up of patients with CTDs. As such, general knowledge of the most common high-resolution computed tomographic features of CTD-related lung disease allows the radiologist to contribute to better patient management.
Resumo:
RESUMO - O ozono é o principal componente da poluição fotoquímica do ar. Como agente irritante do aparelho respiratório, os seus efeitos sobre a saúde caracterizam-se, essencialmente, por tosse, dispneia, desconforto torácico e alterações da função pulmonar, encontrando-se também associadas à exposição ambiental a O3 tanto uma maior frequência e gravidade de crises de asma como a ocorrência de quadros clínicos de irritação conjuntival. É sobretudo a partir dos anos 50, com a descoberta de concentrações elevadas de ozono em ambientes de trabalho respeitantes à actividade de soldadura «a arco», que aquele gás passa a ser encarado como factor profissional de risco. No início dos anos 60 surgem os primeiros estudos de exposição a O3 em cabinas de avião, suscitados pela ocorrência, em tripulantes e passageiros, de queixas clínicas de irritação do tracto respiratório. Esta sintomatologia era, até então, atribuída à acção de outros factores, designadamente o sistema de ventilação e o baixo teor de humidade do ar. Posteriormente, alguns estudos revelaram que, em voos comerciais subsónicos, os teores elevados de O3 observados no interior das cabinas poderiam ser provocados pela sua insuficiente destruição nos sistemas de entrada de ar.O presente estudo, efectuado em voos de longo curso realizados em aeronaves Airbus A340-300 numa única rota comercial, teve por objectivo avaliar a exposição a ozono no ar interior em cabina de avião. Os teores médios de concentração de ozono observados foram inferiores aos valores susceptíveis de provocarem efeitos adversos sobre o aparelho respiratório. Como valor máximo instantâneo, foi atingida a concentração de 152 ppb. Adicionalmente, foi constatada a influência das estações do ano nos teores de O3. O conjunto dos resultados obtidos permite concluir que as concentrações de ozono no ar interior nas cabinas de avião estudadas são inferiores às correspondentes concentrações máximas admissíveis, tendo, em todos os voos, sido observado o cumprimento da norma da FAA respeitante à protecção da exposição ao ozono em cabinas de aeronaves de aviação comercial.
Resumo:
Due to their high adsorption capacity of water vapor, earthen plasters can act as a moisture buffer, contributing to balance the relative humidity of the indoor environment of buildings. As a consequence of this capacity earthen plasters may also contribute to the perception of thermal comfort, since a high relative humidity increases the thermal conductivity of air and restricts skin evaporation, increasing the discomfort associated with the perception of heat or cold. Simultaneously, earthen plasters may also contribute to the indoor air quality. In one hand, by mitigating health problems of the respiratory system associated with indoor environment with high relative humidity, in which increases the risk of development of microorganisms usually responsible for infections, allergies or asthma. In the other hand, by mitigating the probability of inflammation of the respiratory system airways associated to exceedingly dry indoor environments. Therefore it also becomes expectable that earthen plasters may contribute for reducing the needs for air conditioning and mechanical ventilation in buildings and, thereby, also allowing the reduction of the associated energy consumption. The «Barrocal» region, located in the sedimentary basin of Algarve, South Portugal, presents geomorphological characteristics that promote the occurrence of soils with a clay mineralogy dominated by illite, which is a clay mineral characterized by a high adsorption capacity of water vapor and low expansibility. This fact turns expectable that these soils have a high potential for interior plastering. In order to evaluate this potential four mortars were formulated with an increasing content of clayey soil extracted from a selected clay quarry from «Barrocal» region. The results from the preliminary characterization campaign confirmed the reduced linear shrinkage of these mortars, as well as their high adsorption-desorption capacity, that is positively correlated with the content of clayey soil present in mortar formulation. However, the mechanical tests showed that the mechanical resistance of these mortars should be improved, for instance through the addition of natural fibers for reinforcement, which will be investigated in future research. This research contributed to increase certainty regarding the potential of clayey soils of the «Barrocal» sub-region of Algarve to produce mortars suitable for eco-efficient interior plastering.
Resumo:
RESUMO - Portugal continental, como outros países europeus, foi afectado por uma onda de calor de grande intensidade no Verão de 2003, com efeitos na mortalidade da população. O excesso de óbitos associados à onda de calor foi estimado pela comparação do número de óbitos observados entre 30 de Julho e 15 de Agosto de 2003 e o número de óbitos esperados se a população tivesse estado exposta às taxas de mortalidade médias do biénio 2000-2001 no respectivo período homólogo. Os óbitos esperados foram calculados com ajustamento para a idade. O número de óbitos observados (O) foi superior ao número esperado (E) em todos os dias do período estudado e o seu excesso global foi estimado em 1953 óbitos (excesso relativo de 43%), dos quais 1317 (61%) ocorreram no sexo feminino e 1742 no grupo de 75 e + anos (89%). A nível distrital, Portalegre teve o maior aumento relativo do número de óbitos (+89%) e Aveiro o menor (+18%). Numa área geográfica contínua do interior do território (Guarda, Castelo Branco, Portalegre e Évora) houve aumentos relativos superiores a 80%. Em termos absolutos, o maior excesso de óbitos ocorreu no distrito de Lisboa (mais cerca de 396) e no do Porto (mais cerca de 183). As causas de morte «golpe de calor» e «desidratação e outros distúrbios metabólicos» tiveram os aumentos relativos mais elevados (razões O/E de, respectivamente, 70 e 8,65). Os maiores aumentos absolutos do número de óbitos ocorreram no grupo das «doenças do aparelho circulatório» (mais 758), nas «doenças do aparelho respiratório» (mais 255) e no conjunto de «todas as neoplasias malignas» (mais 131). No período da onda de calor e no período de comparação, a percentagem dos óbitos que ocorreu nos hospitais (52% e 56%), no domicílio (32 e 33%) e em «outros locais» foi semelhante. A discussão sobre os factores que condicionaram a obtenção dos valores apresentados, relativos ao excesso de óbitos por sexo, grupo etário, distrito, causa e local da morte, permite concluir que os mesmos se afiguram adequados para medir a ordem de grandeza e caracterizar o efeito da onda de calor na mortalidade. O erro aleatório, medido pelos intervalos de confiança, e alguns possíveis erros sistemáticos associados ao período de comparação escolhido não deverão afectar de modo relevante as estimativas.
Resumo:
OBJECTIVE: To analyze parameters of respiratory system mechanics and oxygenation and cardiovascular alterations involved in weaning tracheostomized patients from long-term mechanical ventilation after cardiac surgery. METHODS: We studied 45 patients in their postoperative period of cardiac surgery, who required long-term mechanical ventilation for more than 10 days and had to undergo tracheostomy due to unsuccessful weaning from mechanical ventilation. The parameters of respiratory system mechanics, oxigenation and the following factors were analyzed: type of surgical procedure, presence of cardiac dysfunction, time of extracorporeal circulation, and presence of neurologic lesions. RESULTS: Of the 45 patients studied, successful weaning from mechanical ventilation was achieved in 22 patients, while the procedure was unsuccessful in 23 patients. No statistically significant difference was observed between the groups in regard to static pulmonary compliance (p=0.23), airway resistance (p=0.21), and the dead space/tidal volume ratio (p=0.54). No difference was also observed in regard to the variables PaO2/FiO2 ratio (p=0.86), rapid and superficial respiration index (p=0.48), and carbon dioxide arterial pressure (p=0.86). Cardiac dysfunction and time of extracorporeal circulation showed a significant difference. CONCLUSION: Data on respiratory system mechanics and oxygenation were not parameters for assessing the success or failure. Cardiac dysfunction and time of cardiopulmonary bypass, however, significantly interfered with the success in weaning patients from mechanical ventilation.
Resumo:
Pulmonary infection on cystic fibrosis (CF) patients are associated with a limited qualitative number of microorganisms. During the colonization process, Staphylococcus aureus usually preceedes Pseudomonas aeruginosa. This latter is at first non-mucoid, being replaced or associated to a mucoid morphotype which is rare in other diseases. In 1980, Pseudomonas cepacia appeared as an important agent in CF pulmonary infections with a mean frequency of about 6.1% isolations in different parts of the world. The primus colonization mainly occurs in the presence of pre-existent tissue lesions and the clinical progress of the disease is variable. In some patients it can be fulminant; in others it can cause a gradual and slow decrease in their pulmonary functions. The concern with this germ isolation is justified by its antibiotic multiple resistence and the possibility of direct transmission from a colonized patient to a non-colonized one. We reported the first case of P. cepacia infection in a CF patient in our area. The microbiological attendance to this patient had been made from 1986 to 1991 and the first positive culture appeared in 1988. The sensitivity profile showed that the primus colonization strain was sensitive to 9 of 17 tested antibiotics, however in the last culture the strain was resistent to all antibiotics. These data corroborate the need for monitoring the bacterial flora on CF patients respiratory system.