951 resultados para Reproducibility


Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE : To compare the reliability and convergent validity of instruments assessing quality of life in Brazilian older adults. METHODS : Cross-sectional study of 278 literate, community-dwelling older adults attending a municipal university for the elderly in Sao Carlos, SP, Southeastern Brazil between 2006 and 2008. The Brazilian versions of the SF-36 and WHOQOL-BREF instruments to assess quality of life were compared. Cronbach’s alpha coefficient was used to estimate reliability and Pearson’s correlation for comparison between the two scales. RESULTS : Most of participants were women (87.8%) with a mean age of 63.83±7.22 years. Both scales showed an acceptable internal consistency – WHOQOL-BREF Cronbach’s alpha was 0.832 and SF-36 was 0.868. There was a weak (r ≤ 0.6) correlation between the related fields in the two questionnaires. CONCLUSIONS : The SF-36 and WHOQOL-BREF are reliable instruments for clinical and research uses in Brazilian older women. To select one, researchers should consider which aspects of quality of life they aim to capture because of weak convergent validity signs. This study’s results indicate that WHOQOL-BREF may be more relevant to evaluate changes in the quality of life of older women because it prioritizes responses to the aging process and avoids focusing on impairment.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE Translate the Patient-centered Assessment and Counseling for Exercise questionnaire, adapt it cross-culturally and identify the psychometric properties of the psychosocial scales for physical activity in young university students.METHODS The Patient-centered Assessment and Counseling for Exercise questionnaire is made up of 39 items divided into constructs based on the social cognitive theory and the transtheoretical model. The analyzed constructs were, as follows: behavior change strategy (15 items), decision-making process (10), self-efficacy (6), support from family (4), and support from friends (4). The validation procedures were conceptual, semantic, operational, and functional equivalences, in addition to the equivalence of the items and of measurements. The conceptual, of items and semantic equivalences were performed by a specialized committee. During measurement equivalence, the instrument was applied to 717 university students. Exploratory factor analysis was used to verify the loading of each item, explained variance and internal consistency of the constructs. Reproducibility was measured by means of intraclass correlation coefficient.RESULTS The two translations were equivalent and back-translation was similar to the original version, with few adaptations. The layout, presentation order of the constructs and items from the original version were kept in the same form as the original instrument. The sample size was adequate and was evaluated by the Kaiser-Meyer-Olkin test, with values between 0.72 and 0.91. The correlation matrix of the items presented r < 0.8 (p < 0.05). The factor loadings of the items from all the constructs were satisfactory (> 0.40), varying between 0.43 and 0.80, which explained between 45.4% and 59.0% of the variance. Internal consistency was satisfactory (α ≥ 0.70), with support from friends being 0.70 and 0.92 for self-efficacy. Most items (74.3%) presented values above 0.70 for the reproducibility test.CONCLUSIONS The validation process steps were considered satisfactory and adequate for applying to the population.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Dissertation presented at the Faculty of Science and Technology of the New University of Lisbon in fulfillment of the requirements for the Masters degree in Electrical Engineering and Computers

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this paper the authors intend to demonstrate the utilization of remote experimentation (RE) using mobile computational devices in the Science areas of the elementary school, with the purpose to develop practices that will help in the assimilation process of the subjects taught in classroom seeking to interlink them with the daily students? activities. Allying mobility with RE we intend to minimize the space-temporal barrier giving more availability and speed in the information access. The implemented architecture utilizes technologies and freely distributed softwares with open code resources besides remote experiments developed in the Laboratory of Remote Experimentation (RExLab) of Federal University of Santa Catarina (UFSC), in Brazil, through the physical computation platform of the ?open hardware of construction of our own. The utilization of open code computational tools and the integration of hardware to the 3D virtual worlds, accessible through mobile devices, give to the project an innovative face with a high potential for reproducibility and reusability.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

ABSTRACT OBJECTIVE : To evaluate the validity and reliability of the Questionnaire for Compliance with Standard Precaution for nurses. METHODS : This methodological study was conducted with 121 nurses from health care facilities in Sao Paulo's countryside, who were represented by two high-complexity and by three average-complexity health care facilities. Internal consistency was calculated using Cronbach's alpha and stability was calculated by the intraclass correlation coefficient, through test-retest. Convergent, discriminant, and known-groups construct validity techniques were conducted. RESULTS : The questionnaire was found to be reliable (Cronbach's alpha: 0.80; intraclass correlation coefficient: (0.97) In regards to the convergent and discriminant construct validity, strong correlation was found between compliance to standard precautions, the perception of a safe environment, and the smaller perception of obstacles to follow such precautions (r = 0.614 and r = 0.537, respectively). The nurses who were trained on the standard precautions and worked on the health care facilities of higher complexity were shown to comply more (p = 0.028 and p = 0.006, respectively). CONCLUSIONS : The Brazilian version of the Questionnaire for Compliance with Standard Precaution was shown to be valid and reliable. Further investigation must be conducted with nurse samples that are more representative of the Brazilian reality. The use of the questionnaire may support the creation of educational measures considering the possible gaps that can be identified, focusing on the workers' health and on the patients' safety.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

ABSTRACT OBJECTIVE To validate a Spanish version of the Test of Gross Motor Development (TGMD-2) for the Chilean population. METHODS Descriptive, transversal, non-experimental validity and reliability study. Four translators, three experts and 92 Chilean children, from five to 10 years, students from a primary school in Santiago, Chile, have participated. The Committee of Experts has carried out translation, back-translation and revision processes to determine the translinguistic equivalence and content validity of the test, using the content validity index in 2013. In addition, a pilot implementation was achieved to determine test reliability in Spanish, by using the intraclass correlation coefficient and Bland-Altman method. We evaluated whether the results presented significant differences by replacing the bat with a racket, using T-test. RESULTS We obtained a content validity index higher than 0.80 for language clarity and relevance of the TGMD-2 for children. There were significant differences in the object control subtest when comparing the results with bat and racket. The intraclass correlation coefficient for reliability inter-rater, intra-rater and test-retest reliability was greater than 0.80 in all cases. CONCLUSIONS The TGMD-2 has appropriate content validity to be applied in the Chilean population. The reliability of this test is within the appropriate parameters and its use could be recommended in this population after the establishment of normative data, setting a further precedent for the validation in other Latin American countries.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

ABSTRACT OBJECTIVE To validate an instrument designed to assess health promotion in the school environment. METHODS A questionnaire, based on guidelines from the World Health Organization and in line with the Brazilian school health context, was developed to validate the research instrument. There were 60 items in the instrument that included 40 questions for the school manager and 20 items with direct observations made by the interviewer. The items’ content validation was performed using the Delphi technique, with the instrument being applied in 53 schools from two medium-sized cities in the South region of Brazil. Reliability (Cronbach’s alpha and split-half) and validity (principal component analysis) analyses were performed. RESULTS The final instrument remained composed of 28 items, distributed into three dimensions: pedagogical, structural and relational. The resulting components showed good factorial loads (> 0.4) and acceptable reliability (> 0.6) for most items. The pedagogical dimension identifies educational activities regarding drugs and sexuality, violence and prejudice, auto care and peace and quality of life. The structural dimension is comprised of access, sanitary structure, and conservation and equipment. The relational dimension includes relationships within the school and with the community. CONCLUSIONS The proposed instrument presents satisfactory validity and reliability values, which include aspects relevant to promote health in schools. Its use allows the description of the health promotion conditions to which students from each educational institution are exposed. Because this instrument includes items directly observed by the investigator, it should only be used during periods when there are full and regular activities at the school in question.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

ABSTRACT OBJECTIVE To assess the internal consistency of the measurements of the Self-Reporting Questionnaire (SRQ-20) in different occupational groups. METHODS A validation study was conducted with data from four surveys with groups of workers, using similar methods. A total of 9,959 workers were studied. In all surveys, the common mental disorders were assessed via SRQ-20. The internal consistency considered the items belonging to dimensions extracted by tetrachoric factor analysis for each study. Item homogeneity assessment compared estimates of Cronbach’s alpha (KD-20), the alpha applied to a tetrachoric correlation matrix and stratified Cronbach’s alpha. RESULTS The SRQ-20 dimensions showed adequate values, considering the reference parameters. The internal consistency of the instrument items, assessed by stratified Cronbach’s alpha, was high (> 0.80) in the four studies. CONCLUSIONS The SRQ-20 showed good internal consistency in the professional categories evaluated. However, there is still a need for studies using alternative methods and additional information able to refine the accuracy of latent variable measurement instruments, as in the case of common mental disorders.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

An in vitro assay system that included automated radiometric quantification of 14CO2 released as a result of oxidation of 14C- substrates was applied for studying the metabolic activity of M. tuberculosis under various experimental conditions. These experiments included the study of a) mtabolic pathways, b) detection times for various inoculum sizes, c) effect of filtration on reproducibility of results, d) influence of stress environment e) minimal inhibitory concentrations for isoniazid, streptomycin, ethambutol and rifampin, and f) generation times of M. tuberculosis and M. bovis. These organisms were found to metabolize 14C-for-mate, (U-14C) acetate, (U-14C) glycerol, (1-14C) palmitic acid, 1-14C) lauric acid, (U-14C) L-malic acid, (U-14C) D-glucose, and (U-14C) D-glucose, but not (1-14C) L-glucose, (U-14C) glycine, or (U-14C) pyruvate to 14CO2. By using either 14C-for-mate, (1-14C) palmitic acid, or (1-14C) lauric acid, 10(7) organisms/vial could be detected within 24 48 hours and as few as 10 organisms/vial within 16-20 days. Reproducible results could be obtained without filtering the bacterial suspension, provided that the organisms were grown in liquid 7H9 medium with 0.05% polysorbate 80 and homogenized prior to the study. Drugs that block protein synthesis were found to have lower minimal inhibitory concentrations with the radiometric method when compared to the conventional agar dilution method. The mean generation time obtained for M. bovis and different strains of M. tuberculosis with various substrates was 9 ± 1 hours.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Brain dopamine transporters imaging by Single Emission Tomography (SPECT) with 123I-FP-CIT (DaTScanTM) has become an important tool in the diagnosis and evaluation of Parkinson syndromes.This diagnostic method allows the visualization of a portion of the striatum – where healthy pattern resemble two symmetric commas - allowing the evaluation of dopamine presynaptic system, in which dopamine transporters are responsible for dopamine release into the synaptic cleft, and their reabsorption into the nigrostriatal nerve terminals, in order to be stored or degraded. In daily practice for assessment of DaTScan TM, it is common to rely only on visual assessment for diagnosis. However, this process is complex and subjective as it depends on the observer’s experience and it is associated with high variability intra and inter observer. Studies have shown that semiquantification can improve the diagnosis of Parkinson syndromes. For semiquantification, analysis methods of image segmentation using regions of interest (ROI) are necessary. ROIs are drawn, in specific - striatum - and in nonspecific – background – uptake areas. Subsequently, specific binding ratios are calculated. Low adherence of semiquantification for diagnosis of Parkinson syndromes is related, not only with the associated time spent, but also with the need of an adapted database of reference values for the population concerned, as well as, the examination of each service protocol. Studies have concluded, that this process increases the reproducibility of semiquantification. The aim of this investigation was to create and validate a database of healthy controls for Dopamine transporters with DaTScanTM named DBRV. The created database has been adapted to the Nuclear Medicine Department’s protocol, and the population of Infanta Cristina’s Hospital located in Badajoz, Spain.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Dissertação apresentada na Faculdade de Ciências e Tecnologia da Universidade Nova de Lisboa para obtenção do grau de Mestre em Conservação e Restauro

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In the present work the immune adherence hemagglutination test (IAHA) was standardized in a simplified procedure. This test showed good reproducibility, better than the classical mice serum neutralization test (SN). The tests showed high correlation degree: high titers in one test corresponded to high titers in the other one, and the same occured with low titers. The IAHA test is extremely simple, fast to perform, and of low cost when compared to tests such as SN or indirect immunofluorescense (IIF). It also proved to be useful in less sophisticated laboratories or even as a screening test for the titration of rabies antibodies.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A dot enzyme-linked immunosorbent assay (DOT-ELISA) was developed to detect specific antibodies in cerebrospinal fluid (CSF) for human neurocysticercosis immunodiagnosis, with Cysticercus cellulosae antigen dotted on a new solid-phase. This was represented by sheets of a synthetic polyester fabric impregnated with a polymerized resin (N-methylol-acrylamide). A very stable preparation was thus obtained, the antigen being covalently bound by cross-linking with free N-methylol groups on the resin. Since robust, no special care was necessary for handling the solid-phase. The test could be performed at room-temperature. From 30 CSF samples assayed, 14 were positive, from a group of 15 cases of neurocysticercosis, with titers from 1 to 128; 15 other samples, from normals or other neurological diseases, were all negative. Test characteristics seem to indicate it as adequate for epidemiological surveys. A more detailed study on sensitivity, specificity, reproducibility and the use in serum samples is being conducted.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Indirect Immunofluorescence (IFA), Plaque Reduction Neutralization (PRN) and Haemagglutination Inhibition (HI) tests for measles antibodies were carried out in 197 sera obtained from umbilical cord and vaccinated children. The IFA was also applied to blood samples collected with filter paper. IFA results demonstrated that the test is relatively simple to perform, with good reproducibility for different antigen lots. Good correlation was obtained between IFA, PRN and HI antibody titers. Better correlation was demonstrated with IFA and PRN than with HI and PRN tests. Sensitivity of IFA in detecting antibody was less effective than PRN, however more effective than HI using rhesus monkey red blood cells. PRN antibody titers over 100 were detected by IFA but not by HI (9.7% with negative results). IFA may be of considerable practical use and able to substitute HI in Seroepidemiological surveys and to evaluate vaccine efficacy. It also can be simplified by employing filter paper collected samples.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

An enzyme-linked immunosorbent assay (ELISA) for measles antibodies was compared with Plaque Neutralization (PRN), Haemagglutination inhibition (HI) and Fluorescent antibody (IFA) tests in 181 sera from vaccinated children and umbilical cord. Of 179 positive samples by the sensitive PRN, only two, with titers of 8, were negative by ELISA (copositivity of 98.9%). IFA and HI presented, respectively, copo-sitivities of 93.3% and 82.7%. The ELISA presented a high sensitivity as well as a good reproducibility and represents an alternative for the time consuming PRN for detection of low measles antibodies.