847 resultados para Repetitive transcranial magnetic stimulation


Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper evaluates a new, low-frequency finite-difference time-domain method applied to the problem of induced E-fields/eddy currents in the human body resulting from the pulsed magnetic field gradients in MRI. In this algorithm, a distributed equivalent magnetic current is proposed as the electromagnetic source and is obtained by quasistatic calculation of the empty coil's vector potential or measurements therein. This technique circumvents the discretization of complicated gradient coil geometries into a mesh of Yee cells, and thereby enables any type of gradient coil modelling or other complex low frequency sources. The proposed method has been verified against an example with an analytical solution. Results are presented showing the spatial distribution of gradient-induced electric fields in a multi-layered spherical phantom model and a complete body model. (C) 2004 Elsevier Inc. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The topography of the visual evoked magnetic response (VEMR) to a pattern onset stimulus was studied in five normal subjects using a single channel BTi magnetometer. Topographic distributions were analysed at regular intervals following stimulus onset (chronotopograpby). Two distinct field distributions were observed with half field stimulation: (1) activity corresponding to the C11 m which remains stable for an average of 34 msec and (2) activity corresponding to the C111 m which remains stable for about 50 msec. However, the full field topography of the largest peak within the first 130 msec does not have a predictable latency or topography in different subjects. The data suggest that the appearance of this peak is dependent on the amplitude, latency and duration of the half field C11 m peaks and the efficiency of half field summation. Hence, topographic mapping is essential to correctly identify the C11 m peak in a full field response as waveform morphology, peak latency and polarity are not reliable indicators. © 1993.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The topography of the visual evoked magnetic response (VEMR) to a pattern onset stimulus was investigated using 4 check sizes and 3 contrast levels. The pattern onset response consists of three early components within the first 200ms, CIm, CIIm and CIIIm. The CIIm is usually of high amplitude and is very consistent in latency within a subject. Half field (HF) stimuli produce their strongest response over the contralateral hemisphere; the RHF stimulus exhibiting a lower positivity (outgoing field) and an upper negativity (ingoing field), rotated towards the midline. LHF stimulation produced the opposite response, a lower negative and an upper positive. Larger check sizes produce a single area of ingoing and outgoing field while smaller checks produce on area of ingoing and outgoing field over each hemisphere. Latency did not appear to vary with change in contrast but amplitudes increased with increasing contrast. A more detailed topographic study incorporating source localisation procedures suggested a source for CIIm - 4cm below the scalp, close to the midline with current flowing towards the lateral surface. Similar depth and position estimates but with opposite polarity were obtained for the pattern shift P100m previously. Hence, the P100m and the CIIm may originate in similar areas of visual cortex but reveal different aspects of visual processing. © 1992 Human Sciences Press, Inc.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The topography of the visual evoked magnetic response (VEMR) to pattern reversal stimulation was studied in four normal subjects using a single channel BTI magnetometer. VEMRs were recorded from 20 locations over the occipital scalp and the topographic distribution of the most consistent component (P100M) studied. A single dipole in a sphere model was fitted to the data. Topographic maps were similar when recorded two months apart on the same subject to the same stimulus. Half field (HF) stimulation elicited responses from sources on the medial surface of the calcarine fissure mainly in the contralateral hemisphere as predicted by the cruciform model. The full field (FF) responses to large checks were approximately the sum of the HF responses. However, with small checks, FF stimulation appeared to activate a different combination of sources than the two HFs. In addition, HF topography was more consistent between subjects than FF for small check sizes. Topographic studies of the VEMR may help to explain the analogous visual evoked electrical response and will be essential to define optimal recording positions for clinical applications.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Since the visual evoked potential to pattern reversal stimulation produces a paradoxical lateralisation of the major positive P100 component and since this paradoxical lateralisation is dependent on the stimulus parameters including check and field size, we have therefore, carried out a study of the magnetic response (VEMR) to a pattern reversal stimulus in four normal subjects using both full field and half field stimulation and two different check sizes.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Our motor and perceptual representations of actions seem to be intimately linked and the human mirror neuron system (MNS) has been proposed as the mediator. In two experiments, we presented biological or non-biological movement stimuli that were either congruent or incongruent to a required response prompted by a tone. When the tone occurred with the onset of the last movement in a series, i.e., it was perceived during the movement presentation, congruent biological stimuli resulted in faster reaction times than congruent non-biological stimuli. The opposite was observed for incongruent stimuli. When the tone was presented after visual movement stimulation, however, no such interaction was present. This implies that biological movement stimuli only affect motor behaviour during visual processing but not thereafter. These data suggest that the MNS is an “online” system; longstanding repetitive visual stimulation (Experiment 1) has no benefit in comparison to only one or two repetitions (Experiment 2).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

When required to represent a perspective that conflicts with one's own, functional magnetic resonance imaging (fMRI) suggests that the right ventrolateral prefrontal cortex (rvlPFC) supports the inhibition of that conflicting self-perspective. The present task dissociated inhibition of self-perspective from other executive control processes by contrasting belief reasoning-a cognitive state where the presence of conflicting perspectives was manipulated-with a conative desire state wherein no systematic conflict existed. Linear modeling was used to examine the effect of continuous theta burst stimulation (cTBS) to rvlPFC on participants' reaction times in belief and desire reasoning. It was anticipated that cTBS applied to rvlPFC would affect belief but not desire reasoning, by modulating activity in the Ventral Attention System (VAS). We further anticipated that this effect would be mediated by functional connectivity within this network, which was identified using resting state fMRI and an unbiased model-free approach. Simple reaction-time analysis failed to detect an effect of cTBS. However, by additionally modeling individual measures from within the stimulated network, the hypothesized effect of cTBS to belief (but, importantly, not desire) reasoning was demonstrated. Structural morphology within the stimulated region, rvlPFC, and right temporoparietal junction were demonstrated to underlie this effect. These data provide evidence that inconsistencies found with cTBS can be mediated by the composition of the functional network that is being stimulated. We suggest that the common claim that this network constitutes the VAS explains the effect of cTBS to this network on false belief reasoning. Hum Brain Mapp, 2016. © 2016 Wiley Periodicals, Inc.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper for the first time discusses a computational study of using magneto-electric (ME) nanoparticles to artificially stimulate the neural activity deep in the brain. The new technology provides a unique way to couple electric signals in the neural network to the magnetic dipoles in the nanoparticles with the purpose to enable a non-invasive approach. Simulations of the effect of ME nanoparticles for non-invasively stimulating the brain of a patient with Parkinson’s Disease to bring the pulsed sequences of the electric field to the levels comparable to those of healthy people show that the optimized values for the concentration of the 20-nm nanoparticles (with the magneto-electric (ME) coefficient of 100 V cm21 Oe21 in the aqueous solution) is 36106 particles/cc, and the frequency of the externally applied 300-Oe magnetic field is 80 Hz.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Résumé : Introduction: La douleur chronique et les problèmes de sommeil ont un impact significatif sur la qualité de vie. La prévalence de ces deux conditions augmente substantiellement avec l’âge. L’objectif de cette étude était d’évaluer la faisabilité d’une étude randomisée, contrôlée par placebo et de recueillir des données sur l’efficacité de la stimulation transcrânienne par courant direct (tDCS) pour réduire la douleur et améliorer le sommeil chez des aînés souffrant de douleur chronique d’origines musculo-squelettique. Méthodes: Quatorze patients souffrant de douleur chronique et de problèmes de sommeil ont reçu cinq séances quotidiennes consécutives de tDCS anodique appliquée au cortex moteur primaire (2 mA, 20 minutes) ou cinq séances de tDCS simulée de manière randomisée. L’intensité de la douleur était mesurée avec une échelle visuelle analogue et les paramètres de sommeil avec l’actigraphie. Pendant toute la durée de l’étude, des journaux de bord de douleur et de sommeil étaient aussi utilisés afin de mesurer l'effet de la tDCS sur la douleur et le sommeil du quotidien des participants. Résultats: Les résultats indiquent que la tDCS réelle engendre une analgésie de 59 %, alors que la tDCS simulée ne réduit pas la douleur (p < 0,05). Par contre, aucun changement n’a été observé au niveau des paramètres de sommeil (tous les p ≥ 0,18). Conclusion: Il appert que cinq séances de tDCS anodique appliquée au niveau du cortex moteur primaire seraient efficaces pour réduire la douleur des aînés souffrant de douleur chronique, mais pas pour améliorer leur sommeil. De futures études seront nécessaires afin de déterminer si d’autres paramètres de stimulation pourraient avoir un impact sur le sommeil et si ces résultats peuvent être reproduits en utilisant un plus grand nombre de patients.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Nanoparticles are often considered as efficient drug delivery vehicles for precisely dispensing the therapeutic payloads specifically to the diseased sites in the patient’s body, thereby minimizing the toxic side effects of the payloads on the healthy tissue. However, the fundamental physics that underlies the nanoparticles’ intrinsic interaction with the surrounding cells is inadequately elucidated. The ability of the nanoparticles to precisely control the release of its payloads externally (on-demand) without depending on the physiological conditions of the target sites has the potential to enable patient- and disease-specific nanomedicine, also known as Personalized NanoMedicine (PNM). In this dissertation, magneto-electric nanoparticles (MENs) were utilized for the first time to enable important functions, such as (i) field-controlled high-efficacy dissipation-free targeted drug delivery system and on-demand release at the sub-cellular level, (ii) non-invasive energy-efficient stimulation of deep brain tissue at body temperature, and (iii) a high-sensitivity contrasting agent to map the neuronal activity in the brain non-invasively. First, this dissertation specifically focuses on using MENs as energy-efficient and dissipation-free field-controlled nano-vehicle for targeted delivery and on-demand release of a anti-cancer Paclitaxel (Taxol) drug and a anti-HIV AZT 5’-triphosphate (AZTTP) drug from 30-nm MENs (CoFe2O4-BaTiO3) by applying low-energy DC and low-frequency (below 1000 Hz) AC fields to separate the functions of delivery and release, respectively. Second, this dissertation focuses on the use of MENs to non-invasively stimulate the deep brain neuronal activity via application of a low energy and low frequency external magnetic field to activate intrinsic electric dipoles at the cellular level through numerical simulations. Third, this dissertation describes the use of MENs to track the neuronal activities in the brain (non-invasively) using a magnetic resonance and a magnetic nanoparticle imaging by monitoring the changes in the magnetization of the MENs surrounding the neuronal tissue under different states. The potential therapeutic and diagnostic impact of this innovative and novel study is highly significant not only in HIV-AIDS, Cancer, Parkinson’s and Alzheimer’s disease but also in many CNS and other diseases, where the ability to remotely control targeted drug delivery/release, and diagnostics is the key.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador: