969 resultados para Reliability, Failure Distribution Function, Hazard Rate, Exponential Distribution
Resumo:
"Supported in part by the Atomic Energy Commission."
Resumo:
Thesis--Illinois.
Resumo:
"January 1981."
Resumo:
Mode of access: Internet.
Resumo:
Bibliography: leaves 41-43.
Resumo:
The purpose of this study is to analyze the distribution, forms, and function(s) of iron amulets deposited in the late Iron Age gravefields of Lovö, with the goal of ascertaining how (and so far as possible why) these objects were utilized in rituals carried out during and after burials. Particular emphasis is given to re-interpreting the largest group of iron amulets, the iron amulet rings, in a more relational and practice-focused way than has heretofore been attempted. By framing burial analyses, questions of typology, and evidence of ritualized actions in comparison with what is known of other cult sites in Mälardalen specifically– and theorized about the cognitive landscape(s) of late Iron Age Scandinavia generally– a picture of iron amulets as inscribed objects made to act as catalytic, protective, and mediating agents is brought to light.
Resumo:
Thesis (Ph.D.)--University of Washington, 2016-06
Resumo:
Background. Australian Aborigines living in remote areas have exceedingly high rates of renal failure together with increased cardiovascular morbidity and mortality. To examine the basis of this association, we studied markers of renal function and cardiovascular (CV) risk in a coastal Aboriginal community in a remote area of the Northern Territory of Australia. End-stage renal disease (ESRD) incidence rates in that community are 15 times the national non-Aboriginal rate and CV mortality rates in the region are increased 5-fold. Methods. A cross-sectional community survey was conducted. Markers of early renal disease examined included urine albumin/creatinine ratio (ACR), serum creatinine concentration and calculated glomerular filtration rate (GFR). CV risk markers included blood pressure as well as measures of glycaemia, diabetes and serum lipids. Results. The study group included 237 people, 58% of the adult population of the community. The crude prevalence of microalbuminuria (urine ACR: 3.4-33.9 g/mol, 30-299 mg/g) was 31% and of overt albuminuria (urine ACR: greater than or equal to34 g/mol, greater than or equal to300 mg/g), 13%. The prevalence of overt albuminuria increased with age, but the prevalence of microalbuminuria was greatest in the 45-54 year age group. Microalbuminuria was associated with increasing body mass index, whereas overt albuminuria was associated with increasing glycated haemoglobin (HbA1c) and systolic blood pressure and a history of diabetes. The prevalence of elevated serum creatinine concentration (greater than or equal to120 mumol/l) was 10%. GFR (calculated using the MDRD equation) was <60 ml/min/1.73m(2) in 12% and 60-79 ml/min/1.73 m(2) in a further 36% of the study population. Although many people with albuminuria had well preserved GFRs, mean GFR was lower in people with higher levels of albuminuria. Conclusions. The high prevalence of markers of renal disease in this community was consistent with their high rates of ESRD. The distribution of microalbuminuria suggested a 'cohort effect', representing a group who will progress to overt albuminuria. The powerful association of renal disease markers with CV risk factors confirms a strong link between renal and CV disease in the early, asymptomatic stages of each. Thus, pathologic albuminuria, in part, might be a manifestation of the metabolic/haemodynamic syndrome and both conditions might arise out of a common menu of risk factors. Hence, a single agenda of primary and secondary intervention may benefit both.
Resumo:
In this paper, we propose features extracted from the heart rate variability (HRV) based on the first and second conditional moments of time-frequency distribution (TFD) as an additional guide for seizure detection in newborn. The features of HRV in the low frequency band (LF: 0-0.07 Hz), mid frequency band (MF: 0.07-0.15 Hz), and high frequency band (HF: 0.15-0.6 Hz) have been obtained by means of the time-frequency analysis using the modified-B distribution (MBD). Results of ongoing time-frequency research are presented. Based on our preliminary results, the first conditional moment of HRV which is also known as the mean/central frequency in the LF band and the second conditional moment of HRV which is also known as the variance/instantaneous bandwidth (IB) in the HF band can be used as a good feature to discriminate the newborn seizure from the non-seizure
Resumo:
This work is concerned with a study of certain phenomena related to the performance and design of distributors in gas fluidized beds with particular regard to flowback of solid particles. The work to be described is divided into two parts. I. In Part one, a review of published material pertaining to distribution plates, including details from the patent specifications, has been prepared. After a chapter on the determination of the incipient fluidizing velocity, the following aspects of multi-orifice distributor plates in gas fluidized beds have been studied: (i) The effect of the distributor on bubble formation related to the way in which even distribution of bubbles on the top surface of the fluidized bed is obtained, e.g. the desirable pressure drop ratio ?PD/?PB for the even distribution of gas across the bed. Ratios of distributor pressure drop ?PD to bed pressure drop at which stable fluidization occurs show reasonable agreement with industrial practice. There is evidence that larger diameter beds tend to be less stable than smaller diameter beds when these are operated with shallow beds. Experiments show that in the presence of the bed the distributor pressure drop is reduced relative to the pressure drop without the bed, and this pressure drop in the former condition is regarded as the appropriate parameter for the design of the distributor. (ii) Experimental measurements of bubble distribution at the surface has been used to indicate maldistribution within the bed. Maldistribution is more likely at low gas flow rates and with distributors having large fractional free area characteristics (i.e. with distributors having low pressure drops). Bubble sizes obtained from this study, as well as those of others, have been successfully correlated. The correlation produced implies the existence of a bubble at the surface of an orifice and its growth by the addition of excess gas from the fluidized bed. (iii) For a given solid system, the amount of defluidized particles stagnating on the distributor plate is influenced by the orifice spacing, bed diameter and gas flow rate, but independent of the initial bed height and the way the orifices are arranged on the distributor plate. II. In Part two, solids flowback through single and multi-orifice distributors in two-dimensional and cylindrical beds of solids fluidized with air has been investigated. Distributors equipped with long cylindrical nozzles have also been included in the study. An equation for the prediction of free flowback of solids through multi-orifice distributors has been derived. Under fluidized conditions two regimes of flowback have been differentiated, namely Jumping and weeping. Data in the weeping regime have been successfully correlated. The limiting gas velocity through the distributor orifices at which flowback is completely excluded is found to be indepnndent of bed height, but a function of distributor design and physical properties of gas and solid used. A criterion for the prediction of this velocity has been established. The decisive advantage of increasing the distributor thickness or using nozzles to minimize solids flowback in fluidized beds has been observed and the opportunity taken to explore this poorly studied subject area. It has been noted, probably for the first time, that with long nozzles, there exists a critical nozzle length above which uncontrollable downflow of solids occurs. A theoretical model for predicting the critical length of a bundle of nozzles in terms of gas velocity through the nozzles has been set up. Theoretical calculations compared favourably with experiments.
Resumo:
An experimental method for characterizing the time-resolved phase noise of a fast switching tunable laser is discussed. The method experimentally determines a complementary cumulative distribution function of the laser's differential phase as a function of time after a switching event. A time resolved bit error rate of differential quadrature phase shift keying formatted data, calculated using the phase noise measurements, was fitted to an experimental time-resolved bit error rate measurement using a field programmable gate array, finding a good agreement between the time-resolved bit error rates.