804 resultados para REFRACTIVE ERRORS
Resumo:
At present, optical microscopy studies of minerals, especially diamonds, are hampered by the lack of available high refractive index (> 1.8) immersion fluids. We report here the syntheses and refractive indices of some 1-alkyl-3-methylimidazolium based ionic liquids containing polyhalide anions, which exhibit refractive indices between 1.6 and 2.23, and thus significantly extend the range of minerals which can be studied.
Resumo:
From perspective of structure synthesis, certain special geometric constraints, such as joint axes intersecting at one point or perpendicular to each other, are necessary in realizing the end-effector motion of kinematically decoupled parallel manipulators (PMs) along individual motion axes. These requirements are difficult to achieve in the actual system due to assembly errors and manufacturing tolerances. Those errors that violate the geometric constraint requirements are termed “constraint errors”. The constraint errors usually are more troublesome than other manipulator errors because the decoupled motion characteristics of the manipulator may no longer exist and the decoupled kinematic models will be rendered useless due to these constraint errors. Therefore, identification and prevention of these constraint errors in initial design and manufacturing stage are of great significance. In this article, three basic types of constraint errors are identified, and an approach to evaluate the effects of constraint errors on decoupling characteristics of PMs is proposed. This approach is illustrated by a 6-DOF PM with decoupled translation and rotation. The results show that the proposed evaluation method is effective to guide design and assembly.
Resumo:
Suicide attacks have raised the stakes for officers deciding whether or not to shoot a suspect ('Police Officer's Terrorist Dilemma'). Despite high-profile errors we know little about how trust in the police is affected by their response to the terrorist threat. Building on a conceptualisation of lay observers as intuitive signal detection theorists, a general population sample (N= 1153) were presented with scenarios manipulated in terms of suspect status (Armed/Unarmed), officer decision (Shoot/Not Shoot) and outcome severity (e.g. suspect armed with Bomb/Knife; police shoot suspect/ suspect plus child bystander). Supporting predictions, people showed higher trust in officers who made correct decisions. reflecting good discrimination ability and who decided to shoot, reflecting an 'appropriate' response bias given the relative costs and benefits. This latter effect was moderated by (a) outcome severity, suggesting it did not simply reflect a preference for a particular type of action, and (b) preferences for a tough stance towards terrorism indexed by Right-Wing Authoritarianism (RWA). Despite loss of civilian life, failure to prevent minor terror attacks resulted in no loss of trust amongst people low in RWA. whereas among people high in RWA trust was positive when police erroneously shot all unarmed suspect. Relations to alternative definitions of trust and procedural justice research are discussed. Copyright (C),. 2007 John Wiley & Sons, Ltd.
Resumo:
Three experiments examined developmental changes in serial recall of lists of 6 letters, with errors classified as movements, omissions, intrusions, or repetitions. In Experiments 1 and 2, developmental differences between groups of children aged from 7 to 11 years and adults were found in the pattern of serial recall errors. The errors of older participants were more likely to be movements than were those of younger participants, who made more intrusions and omissions. The number of repetition errors did not change with age, and this finding is interpreted in terms of a developmentally invariant postoutput response inhibition process. This interpretation was supported by the findings of Experiment 3, which measured levels of response inhibition in 7-, 9-, and 11-year-olds by comparing recall of lists with and without repeated items. Response inhibition remained developmentally invariant, although older children showed greater response facilitation (improved correct recall of adjacent repeated items). Group differences in the patterns of other errors are accounted for in terms of developmental changes in levels of output forgetting and changes in the efficiency of temporal encoding processes, (C) 2000 Academic Press.
Resumo:
Past measurements of the radiocarbon interhemispheric offset have been restricted to relatively young samples because of a lack of older dendrochronologically secure Southern Hemisphere tree-ring chronologies. The Southern Hemisphere calibration data set SHCal04 earlier than AD 950 utilizes a variable interhemispheric offset derived from measured 2nd millennium AD Southern Hemisphere/Northern Hemisphere sample pairs with the assumption of stable Holocene ocean/ atmosphere interactions. This study extends the range of measured interhemispheric offset values with 20 decadal New Zealand kauri and Irish oak sample pairs from 3 selected time intervals in the 1st millennium AD and is part of a larger program to obtain high-precision Southern Hemisphere 14C data continuously back to 200 BC. We found an average interhemispheric offset of 35 ± 6 yr, which although consistent with previously published 2nd millennium AD measurements, is lower than the offset of 55–58 yr utilized in SHCal04. We concur with McCormac et al. (2008) that the IntCal04 measurement for AD 775 may indeed be slightly too old but also suggest the McCormac results appear excessively young for the interval AD 755–785. In addition, we raise the issue of laboratory bias and calibration errors, and encourage all laboratories to check their consistency with appropriate calibration curves and invest more effort into improving the accuracy of those curves.
Resumo:
The development of a reflective, gold-coated long-period grating-based sensor for the measurement of chloride ions in solution is discussed. The sensor scheme is based around a long-period fiber grating (LPG)-based Michelson interferometer where the sensor was calibrated and evaluated in the laboratory using sodium chloride solutions, over a wide range of concentrations, from 0.01 to 4.00 M. The grating response creates shifts in the spectral characteristic of the interferometer, formed using the LPG and a reflective surface on the distal end of the fiber, due to the change of refracting index of the solution surrounding it. It was found that the sensitivity of the device could be enhanced over that obtained from a bare fiber by coating the LPG-based interferometer with gold nanoparticles and the results of a cross-comparison of performance were obtained and details discussed. The approach will be explored as a basis to create a portable, low-power device, developed with the potential for installation in concrete structures to determine the ingress of chloride ions, operating through monitoring the refractive index change.
Resumo:
Densities ([rho]) and viscosities ([eta]) of binary mixtures containing the Protic Ionic Liquid (PIL), pyrrolidinium octanoate with five molecular solvents: water, methanol, ethanol, n-butanol, and acetonitrile are determined at the atmospheric pressure as a function of the temperature and within the whole composition range. The refractive index of all mixtures (nD) is measured at 298.15†K. The excess molar volumes VE and deviation from additivity rules of viscosities [eta]E and refractive index [Delta][phi]n, of pyrrolidinium octanoate solutions were then deduced from the experimental results as well as apparent molar volumes V[phi]i, partial molar volumes and thermal expansion coefficients [alpha]p. The excess molar volumes VE are negative over the entire mole fraction range for mixture with water, acetonitrile, and methanol indicating strong hydrogen-bonding interaction for the entire mole fraction. In the case of longest carbon chain alcohols (such as ethanol and n-butanol)†+†pyrrolidinium octanoate solutions, the VE variation as a function of the composition describes an S shape. The deviation from additivity rules of viscosities is negative over the entire composition range for the acetonitrile, methanol, ethanol, and butanol, and becomes less negative with increasing temperature. Whereas, [eta]E of the {[Pyrr][C7CO2]†+†water} binary mixtures is positive in the whole mole fraction range and decreases with increasing temperature. the excess Gibbs free energies of activation of viscous flow ([Delta]G*E) for these systems were calculated. The deviation from additivity rules of refractive index [Delta][phi]n are positive over the whole composition range and approach a maximum of 0.25 in PIL mole fraction for all systems. The magnitude of deviation for [Delta][phi]n describes the following order: water†>†methanol†>†acetonitrile†>†ethanol. Results have been discussed in terms of molecular interactions and molecular structures in these binary mixtures.