407 resultados para Preissmann slot


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Interoperability of water quality data depends on the use of common models, schemas and vocabularies. However, terms are usually collected during different activities and projects in isolation of one another, resulting in vocabularies that have the same scope being represented with different terms, using different formats and formalisms, and published in various access methods. Significantly, most water quality vocabularies conflate multiple concepts in a single term, e.g. quantity kind, units of measure, substance or taxon, medium and procedure. This bundles information associated with separate elements from the OGC Observations and Measurements (O&M) model into a single slot. We have developed a water quality vocabulary, formalized using RDF, and published as Linked Data. The terms were extracted from existing water quality vocabularies. The observable property model is inspired by O&M but aligned with existing ontologies. The core is an OWL ontology that extends the QUDT ontology for Unit and QuantityKind definitions. We add classes to generalize the QuantityKind model, and properties for explicit description of the conflated concepts. The key elements are defined to be sub-classes or sub-properties of SKOS elements, which enables a SKOS view to be published through standard vocabulary APIs, alongside the full view. QUDT terms are re-used where possible, supplemented with additional Unit and QuantityKind entries required for water quality. Along with items from separate vocabularies developed for objects, media, and procedures, these are linked into definitions in the actual observable property vocabulary. Definitions of objects related to chemical substances are linked to items from the Chemical Entities of Biological Interest (ChEBI) ontology. Mappings to other vocabularies, such as DBPedia, are in separately maintained files. By formalizing the model for observable properties, and clearly labelling the separate concerns, water quality observations from different sources may be more easily merged and also transformed to O&M for cross-domain applications.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Analisar as principais opções de jogos ao alcance do apostador brasileiro, com uma ênfase maior nos Bingos. O interesse se deve essencialmente à mudança substancial no funcionamento dos Bingos após a introdução de máquinas caça-níqueis (também conhecidas como Vídeo-bingo). Essas máquinas atraíram (e viciaram) um número considerável de freqüentadores, e dessa forma mudaram a estratégia de funcionamento dos Bingos. O estudo descreverá a maneira como funcionava a operação dos Bingos antes do advento das máquinas de caça-níqueis, bem como seu funcionamento atual; investigará probabilisticamente as chances de um apostador nas máquinas de caça-níqueis; mencionará as estratégias dos Bingos através de uma análise probabilística do jogo de bingo e do comportamento do operador e demonstrará como um apostador pode presumivelmente obter lucro em partidas especiais de bingo. Finalizando o trabalho oferece algumas considerações finais sendo adotado para efeito comparativo, o Apêndice, que resume as chances e lucros esperados dos principais jogos de Cassino e Loteria.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

O objetivo deste estudo in vitro foi avaliar a interação de dois sistemas adesivos (Scotchbond Multi-Purpose - 3M; Clearfil SE Bond - Kuraray) aplicados à dentina de dentes decíduos, através do ensaio de resistência da união à microtração, e da análise da micromorfologia da interface adesiva. Foram confeccionadas duas cavidades ocluso-proximais padronizadas (tipo slot vertical) na mesial e distal de dezoito molares decíduos hígidos. Cada um dos sistemas adesivos foi aplicado em uma das cavidades do mesmo dente. As cavidades foram restauradas com resina composta (Filtek Z 250 – 3M) pela técnica incremental, sendo cada camada fotopolimerizada por 20 s, utilizando uma fonte de luz visível (XL 2500 - 3M). Os dentes foram armazenados por uma semana em água destilada a 4o C e seccionados no sentido vestíbulo-lingual para análise isolada de cada restauração. Cada uma destas foi seccionada em fatias de 0,7 mm de espessura e, em seguida, efetuou-se uma constrição (1 mm) na região da interface de união (parede axial) para obtenção de uma área adesiva com aproximadamente 0,7 mm2. Os corpos-de-prova foram fixados isoladamente em um dispositivo conectado em uma máquina de ensaio universal (Instron – modelo 4411) e submetidos à tração com velocidade de 0,5 mm/min. As superfícies das secções fraturadas foram avaliadas ao MEV (Jeol –5600 LV) e categorizadas em relação aos padrões de fratura ocorridos. Adicionalmente, superfícies planas contendo a interface de união foram preparadas com lixas de carbureto de silício (granulação 1000) e polimento com pastas de diamante (6, 3, 1 e 0,25 µm). Após desidratação em sílica coloidal em temperatura ambiente por 24 h, as superfícies foram cobertas com liga de ouro e, a micromorfologia da união formada na parede axial das restaurações ocluso-proximais, analisadas ao MEV (Jeol –5600 LV). Os resultados do ensaio de resistência de união foram submetidos à análise estatística utilizando o teste t de student em nível de 5% de significância, e os tipos de fraturas e os aspectos micromorfológicos da interface adesiva submetidos à avaliação descritiva. Os valores médios de resistência de união dos adesivos Scothbond Multi-Purpose (21,84±9,90 MPa) e Clearfil SE Bond (25,19±5,33 MPa) não apresentaram diferenças estatisticamente significantes entre si (p=0,27). A análise do tipo de fratura revelou uma maior quantidade de falhas na região de dentina desmineralizada (G1: SMP) e na porção superior da camada híbrida (G2: CSE). A interface de união, em ambos os grupos, foi caracterizada pela formação da camada híbrida, projeção de prolongamentos resinosos adaptados à dentina e com direcionamento relacionado à disposição dos túbulos dentinários na área da cavidade avaliada.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In the globalized world modern telecommunications have assumed key role within the company, causing a large increase in demand for the wireless technology of communication, which has been happening in recent years have greatly increased the number of applications using this technology. Due to this demand, new materials are developed to enable new control mechanisms and propagation of electromagnetic waves. The research to develop new technologies for wireless communication presents a multidisciplinary study that covers from the new geometries for passive antennas, active up to the development of materials for devices that improve the performance at the frequency range of operation. Recently, planar antennas have attracted interest due to their characteristics and advantages when compared with other types of antennas. In the area of mobile communications the need for antennas of this type has become increasingly used, due to intensive development, which needs to operate in multifrequency antennas and broadband. The microstrip antennas have narrow bandwidth due to the dielectric losses generated by irradiation. Another limitation is the degradation of the radiation pattern due to the generation of surface waves in the substrate. Some techniques have been developed to minimize this limitation of bandwidth, such as the study of type materials PBG - Photonic Band Gap, to form the dielectric material. This work has as main objective the development project of a slot resonator with multiple layers and use the type PBG substrate, which carried out the optimization from the numerical analysis and then designed the device initially proposed for the band electromagnetic spectrum between 3-9 GHz, which basically includes the band S to X. Was used as the dielectric material RT/Duroid 5870 and RT/Duroid 6010.LM where both are laminated ceramic-filled PTFE dielectric constants 2.33 and 10.2, respectively. Through an experimental investigation was conducted an analysis of the simulated versus measured by observing the behavior of the radiation characteristics from the height variation of the dielectric multilayer substrates. We also used the LTT method resonators structures rectangular slot with multiple layers of material photonic PBG in order to obtain the resonance frequency and the entire theory involving the electromagnetic parameters of the structure under consideration. xviii The analysis developed in this work was performed using the method LTT - Transverse Transmission Line, in the field of Fourier transform that uses a component propagating in the y direction (transverse to the real direction of propagation z), thus treating the general equations of the fields electric and magnetic and function. The PBG theory is applied to obtain the relative permittivity of the polarizations for the sep photonic composite substrates material. The results are obtained with the commercial software Ansoft HFSS, used for accurate analysis of the electromagnetic behavior of the planar device under study through the Finite Element Method (FEM). Numerical computational results are presented in graphical form in two and three dimensions, playing in the parameters of return loss, frequency of radiation and radiation diagram, radiation efficiency and surface current for the device under study, and have as substrates, photonic materials and had been simulated in an appropriate computational tool. With respect to the planar device design study are presented in the simulated and measured results that show good agreement with measurements made. These results are mainly in the identification of resonance modes and determining the characteristics of the designed device, such as resonant frequency, return loss and radiation pattern

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Recently, planar antennas have attracted interest due to its characteristics as well as the advantages they offer compared to other types of antennas. In the area of mobile communications the need for such antennas has become increasingly intense due to development, which requires antennas that operate in multifrequency and broadband. The microstrip antennas have narrow bandwidth due to losses in the dielectric caused by irradiation. Another limitation is the radiation pattern degradation due to generation of surface waves in the substrate. Some techniques are being developed to minimize this bandwidth limitation, as is the case in the study of type materials PBG - Photonic Band Gap, to compose the dielectric material. The analysis developed in this work were performed with use of the method LTT - Transverse Transmission Line, in the field of Fourier transform that uses a component propagating in the y direction (transerve real direction of propagation z), thus treating the general equations of the fields electric and magnetic fields as a functions of y E and Hy . This work has as main objective the method LTT structures resonator line slot with four layers of material photonic PBG, for obtaining the complex resonant frequency and efficiency of this structure. PBG theory is applied to obtain the relative permittivity for the substrate biases sep compounds photonic material. Numerical-computational results in graph form in two dimensions for all the analysis are presented for the proposed structures that have photonic materials, as substrates

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Eucalyptus spp. plantations represent >60% of the reforested area in Brazil. Although ambrosia beetle attacks on live trees were at first nonexistent, they have begun to appear with greater frequency. Monitoring for pest insects is a key factor in integrated pest management, and baited traps are one of the most widely used methods for insect population detection and survey. We compared the efficiency of the most widely used trap in Brazil to survey for ambrosia beetles and other Scolytidae, the ESALQ-84 type, with other traditionally employed traps: the multiple funnel (Lindgren trap); drainpipe; and slot (Theyson) traps, in a Eucalyptus grandis Hill ex Maiden stand in Brazil. The ESALQ-84 trap was the most efficient in trapping Hypothenemus eruditus Westwood and Hypothenemus obscurus (F.); the multiple funnel trap caught significantly more Cryptocarenus diadematus Eggers; whereas the slot trap caught more Premnobius cavipennis Eichhoff and Xyleborus affinis Eichhoff than the other traps. The drainpipe trap was the least effective trap overall. When corrected for number of beetles caught per trap surface area, catches were significantly higher on the ESALQ-84 trap for the majority of the species analyzed, probably because of a smaller trap surface area. The slot trap was recommended for it caught overall more beetles of the three most economically important scolytid species in eucalypt plantations in Brazil, P. cavipennis, X. affinis, and X, ferrugineus.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Placa e espaçador de polímero derivado do óleo de mamona (PDOM) (Ricinus communis) foram avaliados clínica, radiográfica e histologicamente na tração linear, fixação e fusão vertebral cervical em 20 cães adultos, sem raça definida, pesando entre 17 e 22kg. Foram sacrificados quatro animais aos 10, 30, 60, 90 e 120 dias de pós-operatório. Após exposição da coluna cervical, por acesso ventral, o disco intervertebral de C4-C5 foi fenestrado e a abordagem ao canal medular foi feita por meio de fenda óssea. Um espaçador de PDOM foi colocado preenchendo o defeito ósseo. Os corpos vertebrais C4-C5 foram fixados com placa do mesmo material, utilizando-se dois parafusos corticais em cada corpo vertebral. Apenas um animal apresentou déficit neurológico no pós-operatório imediato. Radiograficamente as vértebras mostravam-se normais e alinhadas, sem colapso do espaço intervertebral, porém não houve neoformação óssea entre as vértebras. Ao exame mielográfico, não houve compressão da medula espinhal. Os implantes foram efetivos em manter a tração linear e fixação das vértebras cervicais e não ocorreu a fusão vertebral.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study was to determine the effect of two light-curing units (QTH and LED) on microleakage of Class II composite resin restorations with dentin cavosurface margins. Twenty extracted mandibular first premolars, free of caries and fractures were prepared two vertical slot cavities in the occluso-mesial and -destal surfaces (2 mm buccal-lingually, 2 mm proximal-axially and cervical limit in enamel) and divided into 4 equal groups (n = 8): GI and GII: packable posterior composite light-activated with LED and QTH, respectively; GIII and GIV: micro-hybrid composite resin light-activated with LED and QTH, respectively. The composite resins were applied following the manufacturer's instructions. After 24 h of water storage specimens were subjected to thermocycling for a total of 500 cycles at 5 and 55A degrees C and the teeth were then sealed with impermeable material. Teeth were immersed in 0.5% Basic fuchsin during 24 h at room temperature, and zero to three levels of penetration score were attributed. The Mann-Whitney and Kruskal-Wallis tests showed significant statistically similar (P > 0.05) from GI to GII and GIII to GIV, which the GII (2.750) had the highest mean scores and the GIII and GIV (0.875) had lowest mean scores. The use of different light-curing units has no influence on marginal integrity of Class II composite resin restorations and the proprieties of composite resins are important to reduce the microleakage.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Statement of problem. The use of ultrasonic tips has become an alternative for cavity preparation. However, there are concerns about this type of device, particularly with respect to intrapulpal temperatures and cavity preparation time.Purpose. The purpose of this study was to analyze pulpal temperature increases generated by an ultrasonic cavity preparation with chemical vapor deposition (CVD) tips, in comparison to preparation with a high-speed handpiece with a diamond rotary cutting instrument. The time required to complete the cavity preparation with each system was also evaluated.Material and methods. Thermocouples were positioned in the pulp chamber of 20 extracted human third molars. Slot-type cavities (3 x 3 x 2 mm) were prepared on the buccal and the lingual surfaces of each tooth. The test groups were: high-speed cavity preparation with diamond rotary cutting instruments (n = 20) and ultrasonic cavity preparation with CVD points (n = 20). During cavity preparation, the increases In pulpal temperature, and the time required for the preparation, were recorded and analyzed by Student's t test for paired samples (alpha = .05).Results. The average pulpal temperature increases were 4.3 degrees C for the high-speed preparation and 3.8 degrees C for the ultrasonic preparation, which were statistically similar (P = .052). However, significant differences were found (P < .001) for the time expended (3.3 minutes for the high-speed bur and 13.77 minutes for the ultrasound device).Conclusions. The intrapulpal temperatures produced during cavity preparation by ultrasonic tips versus high-speed bur preparation were similar. However, the use of the ultrasonic device required 4 times longer for the completion of a cavity preparation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

O objetivo deste trabalho foi verificar quanto tempo após a realização da enxertia hipocotiledonar ocorre a soldadura ou adesão entre enxerto e porta-enxerto, e também a formação da ponte de calo, verificada pelo total preenchimento da fenda por tecido meristemático secundário (calo). Foram produzidas 56 mudas de maracujazeiro-amarelo (Passiflora edulis Sims f. flavicarpa Deg.) pela enxertia hipocotiledonar em fenda cheia no topo sobre dois porta-enxertos (P. edulis Sims f. flavicarpa Deg. e P. alata Dryander). Aos 0, 3, 6, 9, 12, 15 e 18 dias após a enxertia, coletou-se a região da enxertia de quatro mudas de cada combinação. O material coletado foi fixado em solução de glutaraldeído a 3%, pós-fixado em tetróxido de ósmio a 2%, desidratado em uma série de álcool etílico (30, 40, 50, 60, 70, 80, 90, 100%), levado ao secador de ponto crítico (CO2), montado, metalizado com ouro - paládio (35 nm) e, por fim, observados e eletromicrografados em microscópio eletrônico de varredura JEOL JSM 5410 (operado em 15 kV). Verificou-se que, aos seis dias após a enxertia, a soldadura para o porta-enxerto Passiflora alata já havia ocorrido, o que só foi constatado para Passiflora edulis f. flavicarpa aos nove dias. Também, aos nove dias, observou-se para ambos os porta-enxertos a completa formação da ponte de calo, indicando que, a partir daí, pode-se iniciar o processo de aclimatação da muda, para levá-la a um ambiente de menor umidade.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Human platelet-derived growth factor (PDGF) was purified from lysates of clinically outdated human platelets by ionic exchange chromatography in CM-Sepharose. The eluated fraction was submitted to the Immunoblot/Slot Blot assay using anti-PDGF-AA and anti-PDGF-BB polyclonal antibodies and was evaluated as to its biological activity through the test of [H 3]-thymidine incorporation in NIH/3T3 cell line fibroblasts in culture. The Immunoblot/Slot Blot assay using anti-PDGF-AA and anti-PDGF-BB antibodies proved the presence of the PDGF in chromatographic cationic fraction. The comparison of biological activities between fiblobrast stimulation assay using recombinant PDGF-AB and partially purified PDGF was demonstrated in 165.796 and 157.567 cpm, respectively. This result, proved the potent mitogenic effect of partially purified PDGF and consequently their evidence about the wound healing activity.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Neurosurgeries are frequent in the routine of veterinary hospitals and, therefore, knowledge of the different anesthetic protocols to be used for each patient is necessary to prevent the morbity and mortality in the after and trans-surgical period. The objectives of this study were to evaluate the anesthetic protocols used in patients undergoing neurosurgeries; the results of those protocols; the rate of complications, and if those complications are related to the duration of the anesthesia time. We studied the anesthetical data of 52 dogs and two cats submitted to neurosurgery between January of 2003 and December of 2006, in the Veterinary Hospital of UEL. Findings showed that the main protocols used were propofol for induction and halothane or isofluorane for maintenance of the anesthesia. These protocols induced adequate anesthesia for the surgical procedure and did not occur complications during the anesthetic period in 37/54 (68,5%) of the cases. 7/19 (36.8%) of the complications observed occurred in patients submitted to anesthesia with halothane and 8/32 (25.2%) in patients with isofluorane. The complication most observed in this study was bradicardy, which occurred in 15/54 (27.8%) of the patients. Two deaths occurred in patients submitted to slot cervical. Good knowledge of the neurological disease and of surgical and anesthetic techniques are essential to prevent alterations in the central nervous system caused by the drugs, disease or association of these factors.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study was to evaluate the effect of brushing with a Colgate 360° or Oral B Indicator 35 toothbrush on the shear bond strength of orthodontic brackets bonded to extracted human teeth. The bristle wear and bristle tip morphology were also examined after simulated tooth-brushing. Orthodontic brackets (Roth-P/1 st and 2 nd pre-molar S/D- Slot 0.18) were bonded (Transbond XT ®) to the smoothest surface of each of 45 extracted human molar and premolar teeth. Test specimens were randomly divided into three groups: Group 1, control group with no brushing; Group 2, brushing with the Oral B Indicator 35; Group 3, brushing with the Colgate 360°. Samples were adapted to a machine that simulated tooth-brushing. The bond strength of each bracket to each tooth was assessed with a mechanical testing machine. The bristle wear and bristle tip morphology indices were also assessed. Statistically significant differences were defined for p ≤ 0.05. The average bond strengths (range: 90.18-90.89 kgf/cm 2) did not differ among the three groups. The Colgate 360° showed less bristle wear and a better bristle tip morphology than the Oral B Indicator 35 toothbrush. However, use of either toothbrush did not decrease the bond strength of the orthodontic brackets. Therefore, patients undergoing orthodontic therapy can safely use either toothbrush.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)