972 resultados para Photon Counting
Resumo:
The present work describes the development of a new body-counter system based on HPGe detectors and installed at IVM of KIT. The goal, achieved, was the improvement of the ability to detect internal contaminations in the human body, especially the ones concerning low-energy emitters and multiple nuclides. The development of the system started with the characterisation of detectors purchased for this specific task, with the optimisation of the different desired measurement configurations following and ending with the installation and check of the results. A new software has been developed to handle the new detectors.
Resumo:
Neuronal circuits in the retina analyze images according to qualitative aspects such as color or motion, before the information is transmitted to higher visual areas of the brain. One example, studied for over the last four decades, is the detection of motion direction in ‘direction selective’ neurons. Recently, the starburst amacrine cell, one type of retinal interneuron, has emerged as an essential player in the computation of direction selectivity. In this study the mechanisms underlying the computation of direction selective calcium signals in starburst cell dendrites were investigated using whole-cell electrical recordings and two-photon calcium imaging. Analysis of the somatic electrical responses to visual stimulation and pharmacological agents indicated that the directional signal (i) is not computed presynaptically to starburst cells or by inhibitory network interactions. It is thus computed via a cell-intrinsic mechanism, which (ii) depends upon the differential, i.e. direction selective, activation of voltage-gated channels. Optically measuring dendritic calcium signals as a function of somatic voltage suggests (iii) a difference in resting membrane potential between the starburst cell’s soma and its distal dendrites. In conclusion, it is proposed that the mechanism underlying direction selectivity in starburst cell dendrites relies on intrinsic properties of the cell, particularly on the interaction of spatio-temporally structured synaptic inputs with voltage-gated channels, and their differential activation due to a somato-dendritic difference in membrane potential.
Resumo:
In dieser Arbeit wurde die elektromagnetische Pionproduktion unter der Annahme der Isospinsymmetrie der starken Wechselwirkung im Rahmen der manifest Lorentz-invarianten chiralen Störungstheorie in einer Einschleifenrechnung bis zur Ordnung vier untersucht. Dazu wurden auf der Grundlage des Mathematica-Pakets FeynCalc Algorithmen zur Berechnung der Pionproduktionsamplitude entwickelt. Bis einschließlich der Ordnung vier tragen insgesamt 105 Feynmandiagramme bei, die sich in 20 Baumdiagramme und 85 Schleifendiagramme unterteilen lassen. Von den 20 Baumdiagrammen wiederum sind 16 als Polterme und vier als Kontaktgraphen zu klassifizieren; bei den Schleifendiagrammen tragen 50 Diagramme ab der dritten Ordnung und 35 Diagramme ab der vierten Ordnung bei. In der Einphotonaustauschnäherung lässt sich die Pionproduktionsamplitude als ein Produkt des Polarisationsvektors des (virtuellen) Photons und des Übergangsstrommatrixelements parametrisieren, wobei letzteres alle Abhängigkeiten der starken Wechselwirkung beinhaltet und wo somit die chirale Störungstheorie ihren Eingang findet. Der Polarisationsvektor hingegen hängt von dem leptonischen Vertex und dem Photonpropagator ab und ist aus der QED bekannt. Weiterhin lässt sich das Übergangsstrommatrixelement in sechs eichinvariante Amplituden zerlegen, die sich im Rahmen der Isospinsymmetrie jeweils wiederum in drei Isospinamplituden zerlegen lassen. Linearkombinationen dieser Isospinamplituden erlauben letztlich die Beschreibung der physikalischen Amplituden. Die in dieser Rechnung auftretenden Einschleifenintegrale wurden numerisch mittels des Programms LoopTools berechnet. Im Fall tensorieller Integrale erfolgte zunächst eine Zerlegung gemäß der Methode von Passarino und Veltman. Da die somit erhaltenen Ergebnisse jedoch i.a. noch nicht das chirale Zählschema erfüllen, wurde die entsprechende Renormierung mittels der reformulierten Infrarotregularisierung vorgenommen. Zu diesem Zweck wurde ein Verfahren entwickelt, welches die Abzugsterme automatisiert bestimmt. Die schließlich erhaltenen Isospinamplituden wurden in das Programm MAID eingebaut. In diesem Programm wurden als Test (Ergebnisse bis Ordnung drei) die s-Wellenmultipole E_{0+} und L_{0+} in der Schwellenregion berechnet. Die Ergebnisse wurden sowohl mit Messdaten als auch mit den Resultaten des "klassischen" MAID verglichen, wobei sich i. a. gute Übereinstimmungen im Rahmen der Fehler ergaben.
A Phase Space Box-counting based Method for Arrhythmia Prediction from Electrocardiogram Time Series
Resumo:
Arrhythmia is one kind of cardiovascular diseases that give rise to the number of deaths and potentially yields immedicable danger. Arrhythmia is a life threatening condition originating from disorganized propagation of electrical signals in heart resulting in desynchronization among different chambers of the heart. Fundamentally, the synchronization process means that the phase relationship of electrical activities between the chambers remains coherent, maintaining a constant phase difference over time. If desynchronization occurs due to arrhythmia, the coherent phase relationship breaks down resulting in chaotic rhythm affecting the regular pumping mechanism of heart. This phenomenon was explored by using the phase space reconstruction technique which is a standard analysis technique of time series data generated from nonlinear dynamical system. In this project a novel index is presented for predicting the onset of ventricular arrhythmias. Analysis of continuously captured long-term ECG data recordings was conducted up to the onset of arrhythmia by the phase space reconstruction method, obtaining 2-dimensional images, analysed by the box counting method. The method was tested using the ECG data set of three different kinds including normal (NR), Ventricular Tachycardia (VT), Ventricular Fibrillation (VF), extracted from the Physionet ECG database. Statistical measures like mean (μ), standard deviation (σ) and coefficient of variation (σ/μ) for the box-counting in phase space diagrams are derived for a sliding window of 10 beats of ECG signal. From the results of these statistical analyses, a threshold was derived as an upper bound of Coefficient of Variation (CV) for box-counting of ECG phase portraits which is capable of reliably predicting the impeding arrhythmia long before its actual occurrence. As future work of research, it was planned to validate this prediction tool over a wider population of patients affected by different kind of arrhythmia, like atrial fibrillation, bundle and brunch block, and set different thresholds for them, in order to confirm its clinical applicability.
Resumo:
Im Juli 2009 wurde am Mainzer Mikrotron (MAMI) erstmal ein Experiment durchgeführt, bei dem ein polarisiertes 3He Target mit Photonen im Energiebereich von 200 bis 800 MeV untersucht wurde. Das Ziel dieses Experiments war die Überprüfung der Gerasimov-Drell-Hearn Summenregel am Neutron. Die Verwendung der Messdaten welche mit dem polarisierten 3He Target gewonnen wurden, geben - im Vergleich mit den bereits existieren Daten vom Deuteron - aufgrund der Spin-Struktur des 3He einen komplementären und direkteren Zugang zum Neutron. Die Messung des totalen helizitätsabhängigen Photoabsorptions-Wirkungsquerschnitts wurde mittels eines energiemarkierten Strahls von zirkular polarisierten Photonen, welcher auf das longitudinal polarisierte 3He Target trifft, durchgeführt. Als Produktdetektoren kamen der Crystal Ball (4π Raumabdeckung), TAPS (als ”Vorwärtswand”) sowie ein Schwellen-Cherenkov-Detektor (online Veto zur Reduktion von elektromagnetischen Ereignissen) zum Einsatz. Planung und Aufbau der verschiedenen komponenten Teile des 3He Experimentaufbaus war ein entscheidender Teil dieser Dissertation und wird detailliert in der vorliegenden Arbeit beschrieben. Das Detektorsystem als auch die Analyse-Methoden wurden durch die Messung des unpolarisierten, totalen und inklusiven Photoabsoprtions-Wirkungsquerschnitts an flüssigem Wasserstoff getestet. Hierbei zeigten die Ergebnisse eine gute Übereinstimmung mit bereits zuvor publizierten Daten. Vorläufige Ergebnisse des unpolarisierten totalen Photoabsorptions-Wirkungsquerschnitts sowie der helizitätsabhängige Unterschied zwischen Photoabsorptions-Wirkungsquerschnitten an 3He im Vergleich zu verschiedenen theoretischen Modellen werden vorgestellt.
Resumo:
This thesis was focused on the investigation of the linear optical properties of novel two photon absorbers for biomedical applications. Substituted imidazole and imidazopyridine derivatives, and organic dendrimers were studied as potential fluorophores for two photon bioimaging. The results obtained showed superior luminescence properties for sulphonamido imidazole derivatives compared to other substituted imidazoles. Imidazo[1,2-a]pyridines exhibited an important dependence on the substitution pattern of their luminescence properties. Substitution at imidazole ring led to a higher fluorescence yield than the substitution at the pyridine one. Bis-imidazo[1,2-a]pyridines of Donor-Acceptor-Donor type were examined. Bis-imidazo[1,2-a]pyridines dimerized at C3 position had better luminescence properties than those dimerized at C5, displaying high emission yields and important 2PA cross sections. Phosphazene-based dendrimers with fluorene branches and cationic charges on the periphery were also examined. Due to aggregation phenomena in polar solvents, the dendrimers registered a significant loss of luminescence with respect to fluorene chromophore model. An improved design of more rigid chromophores yields enhanced luminescence properties which, connected to large 2PA cross-sections, make this compounds valuable as fluorophores in bioimaging. The photophysical study of several ketocoumarine initiators, designed for the fabrication of small dimension prostheses by two photon polymerization (2PP) was carried out. The compounds showed low emission yields, indicative of a high population of the triplet excited state, which is the active state in producing the reactive species. Their efficiency in 2PP was proved by fabrication of microstructures and their biocompatibility was tested in the collaborator’s laboratory. In the frame of the 2PA photorelease of drugs, three fluorene-based dyads have been investigated. They were designed to release the gamma-aminobutyric acid via two photon induced electron transfer. The experimental data in polar solvents showed a fast electron transfer followed by an almost equally fast back electron transfer process, which indicate a poor optimization of the system.
Resumo:
The first part of this work deals with the inverse problem solution in the X-ray spectroscopy field. An original strategy to solve the inverse problem by using the maximum entropy principle is illustrated. It is built the code UMESTRAT, to apply the described strategy in a semiautomatic way. The application of UMESTRAT is shown with a computational example. The second part of this work deals with the improvement of the X-ray Boltzmann model, by studying two radiative interactions neglected in the current photon models. Firstly it is studied the characteristic line emission due to Compton ionization. It is developed a strategy that allows the evaluation of this contribution for the shells K, L and M of all elements with Z from 11 to 92. It is evaluated the single shell Compton/photoelectric ratio as a function of the primary photon energy. It is derived the energy values at which the Compton interaction becomes the prevailing process to produce ionization for the considered shells. Finally it is introduced a new kernel for the XRF from Compton ionization. In a second place it is characterized the bremsstrahlung radiative contribution due the secondary electrons. The bremsstrahlung radiation is characterized in terms of space, angle and energy, for all elements whit Z=1-92 in the energy range 1–150 keV by using the Monte Carlo code PENELOPE. It is demonstrated that bremsstrahlung radiative contribution can be well approximated with an isotropic point photon source. It is created a data library comprising the energetic distributions of bremsstrahlung. It is developed a new bremsstrahlung kernel which allows the introduction of this contribution in the modified Boltzmann equation. An example of application to the simulation of a synchrotron experiment is shown.
Resumo:
Although the Standard Model of particle physics (SM) provides an extremely successful description of the ordinary matter, one knows from astronomical observations that it accounts only for around 5% of the total energy density of the Universe, whereas around 30% are contributed by the dark matter. Motivated by anomalies in cosmic ray observations and by attempts to solve questions of the SM like the (g-2)_mu discrepancy, proposed U(1) extensions of the SM gauge group have raised attention in recent years. In the considered U(1) extensions a new, light messenger particle, the hidden photon, couples to the hidden sector as well as to the electromagnetic current of the SM by kinetic mixing. This allows for a search for this particle in laboratory experiments exploring the electromagnetic interaction. Various experimental programs have been started to search for hidden photons, such as in electron-scattering experiments, which are a versatile tool to explore various physics phenomena. One approach is the dedicated search in fixed-target experiments at modest energies as performed at MAMI or at JLAB. In these experiments the scattering of an electron beam off a hadronic target e+(A,Z)->e+(A,Z)+l^+l^- is investigated and a search for a very narrow resonance in the invariant mass distribution of the lepton pair is performed. This requires an accurate understanding of the theoretical basis of the underlying processes. For this purpose it is demonstrated in the first part of this work, in which way the hidden photon can be motivated from existing puzzles encountered at the precision frontier of the SM. The main part of this thesis deals with the analysis of the theoretical framework for electron scattering fixed-target experiments searching for hidden photons. As a first step, the cross section for the bremsstrahlung emission of hidden photons in such experiments is studied. Based on these results, the applicability of the Weizsäcker-Williams approximation to calculate the signal cross section of the process, which is widely used to design such experimental setups, is investigated. In a next step, the reaction e+(A,Z)->e+(A,Z)+l^+l^- is analyzed as signal and background process in order to describe existing data obtained by the A1 experiment at MAMI with the aim to give accurate predictions of exclusion limits for the hidden photon parameter space. Finally, the derived methods are used to find predictions for future experiments, e.g., at MESA or at JLAB, allowing for a comprehensive study of the discovery potential of the complementary experiments. In the last part, a feasibility study for probing the hidden photon model by rare kaon decays is performed. For this purpose, invisible as well as visible decays of the hidden photon are considered within different classes of models. This allows one to find bounds for the parameter space from existing data and to estimate the reach of future experiments.
Resumo:
Die vorliegende Arbeit beschäftigt sich mit der Modellierung niederenergetischer elektromagnetischer und hadronischer Prozesse im Rahmen einer manifest lorentzinvarianten, chiralen effektiven Feldtheorie unter expliziter, dynamischer Berücksichtigung resonanter, das heißt vektormesonischer Freiheitsgrade. Diese effektive Theorie kann daher als Approximation der grundlegenden Quantenchromodynamik bei kleinen Energien verstanden werden. Besonderes Augenmerk wird dabei auf das verwendete Zähl- sowie Renormierungschema gelegt, wodurch eine konsistente Beschreibung mesonischer Prozesse bis zu Energien von etwa 1GeV ermöglicht wird. Das verwendete Zählschema beruht dabei im Wesentlichen auf einem Argument für großes N_c (Anzahl der Farbfreiheitsgrade) und lässt eine äquivalente Behandlung von Goldstonebosonen (Pionen) und Resonanzen (Rho- und Omegamesonen) zu. Als Renormierungsschema wird das für (bezüglich der starken Wechselwirkung) instabile Teilchen besonders geeignete complex-mass scheme als Erweiterung des extended on-mass-shell scheme verwendet, welches in Kombination mit dem BPHZ-Renormierungsverfahren (benannt nach Bogoliubov, Parasiuk, Hepp und Zimmermann) ein leistungsfähiges Konzept zur Berechnung von Quantenkorrekturen in dieser chiralen effektiven Feldtheorie darstellt. Sämtliche vorgenommenen Rechnungen schließen Terme der chiralen Ordnung vier sowie einfache Schleifen in Feynman-Diagrammen ein. Betrachtet werden unter anderem der Vektorformfaktor des Pions im zeitartigen Bereich, die reelle Compton-Streuung (beziehungsweise Photonenfusion) im neutralen und geladenen Kanal sowie die virtuelle Compton-Streuung, eingebettet in die Elektron-Positron-Annihilation. Zur Extraktion der Niederenergiekopplungskonstanten der Theorie wird letztendlich eine Reihe experimenteller Datensätze verschiedenartiger Observablen verwendet. Die hier entwickelten Methoden und Prozeduren - und insbesondere deren technische Implementierung - sind sehr allgemeiner Natur und können daher auch an weitere Problemstellungen aus diesem Gebiet der niederenergetischen Quantenchromodynamik angepasst werden.
Resumo:
Future experiments in nuclear and particle physics are moving towards the high luminosity regime in order to access rare processes. In this framework, particle detectors require high rate capability together with excellent timing resolution for precise event reconstruction. In order to achieve this, the development of dedicated FrontEnd Electronics (FEE) for detectors has become increasingly challenging and expensive. Thus, a current trend in R&D is towards flexible FEE that can be easily adapted to a great variety of detectors, without impairing the required high performance. This thesis reports on a novel FEE for two different detector types: imaging Cherenkov counters and plastic scintillator arrays. The former requires high sensitivity and precision for detection of single photon signals, while the latter is characterized by slower and larger signals typical of scintillation processes. The FEE design was developed using high-bandwidth preamplifiers and fast discriminators which provide Time-over-Threshold (ToT). The use of discriminators allowed for low power consumption, minimal dead-times and self-triggering capabilities, all fundamental aspects for high rate applications. The output signals of the FEE are readout by a high precision TDC system based on FPGA. The performed full characterization of the analogue signals under realistic conditions proved that the ToT information can be used in a novel way for charge measurements or walk corrections, thus improving the obtainable timing resolution. Detailed laboratory investigations proved the feasibility of the ToT method. The full readout chain was investigated in test experiments at the Mainz Microtron: high counting rates per channel of several MHz were achieved, and a timing resolution of better than 100 ps after walk correction based on ToT was obtained. Ongoing applications to fast Time-of-Flight counters and future developments of FEE have been also recently investigated.
Resumo:
In high energy teletherapy, VMC++ is known to be a very accurate and efficient Monte Carlo (MC) code. In principle, the MC method is also a powerful dose calculation tool in other areas in radiation oncology, e.g., brachytherapy or orthovoltage radiotherapy. However, VMC++ is not validated for the low-energy range of such applications. This work aims in the validation of the VMC++ MC code for photon beams in the energy range between 20 and 1000 keV.
Comparison of monte carlo collimator transport methods for photon treatment planning in radiotherapy
Resumo:
The aim of this work was a Monte Carlo (MC) based investigation of the impact of different radiation transport methods in collimators of a linear accelerator on photon beam characteristics, dose distributions, and efficiency. Thereby it is investigated if it is possible to use different simplifications in the radiation transport for some clinical situations in order to save calculation time.
Resumo:
Carbohydrate counting is a principal strategy in nutritional management of type 1 diabetes. The Nutri-Learn buffet (NLB) is a new computer-based tool for patient instruction in carbohydrate counting. It is based on food dummies made of plastic equipped with a microchip containing relevant food content data. The tool enables the dietician to assess the patient's food counting abilities and the patient to learn in a hands-on interactive manner to estimate food contents such as carbohydrate content.