986 resultados para Pendant-arm


Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: Cuff inflation at the arm is known to cause an instantaneous rise in blood pressure, which might be due to the discomfort of the procedure and might interfere with the precision of the blood pressure measurement. In this study, we compared the reactive rise in blood pressure induced by cuff inflation when the cuff was placed at the upper arm level and at the wrist. PARTICIPANTS AND METHODS: The reactive rise in systolic and diastolic blood pressure to cuff inflation was measured in 34 normotensive participants and 34 hypertensive patients. Each participant was equipped with two cuffs, one around the right upper arm (OMRON HEM-CR19, 22-32 cm) and one around the right wrist (OMRON HEM-CS 19, 17-22 cm; Omron Health Care Europe BV, Hoofddorp, The Netherlands). The cuffs were inflated in a double random order (maximal cuff pressure and position of the cuff) with two maximal cuff pressures: 180 and 240 mmHg. The cuffs were linked to an oscillometric device (OMRON HEM 907; Omron Health Care). Simultaneously, blood pressure was measured continuously at the middle finger of the left hand using photoplethysmography. Three measurements were made at each level of blood pressure at the arm and at the wrist, and the sequence of measurements was randomized. RESULTS: In normotensive participants, no significant difference was observed in the reactive rise in blood pressure when the cuff was inflated either at the arm or at the wrist irrespective of the level of cuff inflation. Inflating a cuff at the arm, however, induced a significantly greater rise in blood pressure than inflating it at the wrist in hypertensive participants for both systolic and diastolic pressures (P<0.01), and at both levels of cuff inflation. The blood pressure response to cuff inflation was independent of baseline blood pressure. CONCLUSIONS: The results show that in hypertensive patients, cuff inflation at the wrist produces a smaller reactive rise in blood pressure. The difference between the arm and the wrist is independent of the patient's level of blood pressure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Collection : Bibliothèque historique

Relevância:

20.00% 20.00%

Publicador:

Resumo:

When a rubber hand is placed on a table top in a plausible position as if part of a person"s body, and is stroked synchronously with the person"s corresponding hidden real hand, an illusion of ownership over the rubber hand can occur (Botvinick and Cohen 1998). A similar result has been found with respect to a virtual hand portrayed in a virtual environment, a virtual hand illusion (Slater et al. 2008). The conditions under which these illusions occur have been the subject of considerable study. Here we exploited the flexibility of virtual reality to examine four contributory factors: visuo-tactile synchrony while stroking the virtual and the real arms, body continuity, alignment between the real and virtual arms, and the distance between them. We carried out three experiments on a total of 32 participants where these factors were varied. The results show that the subjective illusion of ownership over the virtual arm and the time to evoke this illusion are highly dependent on synchronous visuo-tactile stimulation and on connectivity of the virtual arm with the rest of the virtual body. The alignment between the real and virtual arms and the distance between these were less important. It was found that proprioceptive drift was not a sensitive measure of the illusion, but was only related to the distance between the real and virtual arms.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND AND OBJECTIVE: Investigations were performed to establish if repetitive arm cycling training enhances the antispastic effect of intramuscular botulinum toxin (BTX) injections in postischemic spastic hemiparesis. Effects on cerebral activation were evaluated by functional magnetic resonance imaging (fMRI). METHODS: Eight chronic spastic hemisyndrome patients (49 ± 10 years) after middle cerebral artery infarction (5.5 ± 2.7 years) were investigated. BTX was injected into the affected arm twice, 6 months apart. Spasticity was assessed using the Ashworth Scale and range of motion before and 3 months after BTX injections. Images were analyzed using Brain Voyager QX 1.8, and fMRI signal changes were corrected for multiple comparisons. RESULTS: During passive movements of affected and nonaffected hands, fMRI activity was increased bilaterally in the sensorimotor cortex (MISI), secondary somatosensory areas (SII), and supplementary motor area predominantly in the contralesional hemisphere, compared with the rest. Following repetitive arm cycling, fMRI activity increased further in MISI of the lesioned hemisphere and SII of the contralesional hemisphere. For patients with residual motor activity, treatment-related fMRI activity increases were associated with reduced spasticity; in completely plegic patients, there was no fMRI activity change in SII but increased spasticity after training. CONCLUSION: Increased activity in SII of the contralesional hemisphere and in MISI of the lesioned hemisphere reflect a treatment-induced effect in the paretic arm. It is hypothesized that the increased BOLD activity results from increased afferent information related to the antispastic BTX effect reinforced by training.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: Home blood pressure (BP) monitoring is recommended by several clinical guidelines and has been shown to be feasible in elderly persons. Wrist manometers have recently been proposed for such home BP measurement, but their accuracy has not been previously assessed in elderly patients. METHODS: Forty-eight participants (33 women and 15 men, mean age 81.3±8.0 years) had their BP measured with a wrist device with position sensor and an arm device in random order in a sitting position. RESULTS: Average BP measurements were consistently lower with the wrist than arm device for systolic BP (120.1±2.2 vs. 130.5±2.2 mmHg, P<0.001, means±SD) and diastolic BP (66.0±1.3 vs. 69.7±1.3 mmHg, P<0.001). Moreover, a 10 mmHg or greater difference between the arm and wrist device was observed in 54.2 and 18.8% of systolic and diastolic measures, respectively. CONCLUSION: Compared with the arm device, the wrist device with position sensor systematically underestimated systolic as well as diastolic BP. The magnitude of the difference is clinically significant and questions the use of the wrist device to monitor BP in elderly persons. This study points to the need to validate BP measuring devices in all age groups, including in elderly persons.