955 resultados para PERMANENT POROSITY
Resumo:
Intrusion is defined as the axial dislodgment of the tooth into its socket and is considered one of the most severe types of dental trauma. This longitudinal outcome study was undertaken to evaluate clinically and radiographically severely intruded permanent incisors in a population of children and adolescents. All cases were treated between September 2003 and February 2008 in a dental trauma service. Clinical and radiographic data were collected from 12 patients (eight males and four females) that represented 15 permanent maxillary incisors. Mean age at the time of injury was 8 years and 9 months (range 7-14 years and 8 months). Mean time elapsed to follow-up was 26.6 months (range 10-51 months). The analysis of data showed that tooth intrusion was twice as frequent in males. The maxillary central incisors were the most commonly intruded teeth (93.3%), and falling at home was the main etiologic factor (60%). More than half of the cases (53.3%) were multiple intrusions, 73.3% of the intruded teeth had incomplete root formation and 66.6% of the teeth suffered other injuries concomitant to intrusion. Immediate surgical repositioning was the treatment of choice in 66.7% of the cases, while watchful waiting for the tooth to return to its pre-injury position was adopted in 33.3% of the cases. The teeth that suffered additional injuries to the intrusive luxation presented a fivefold increased relative risk of developing pulp necrosis. The immature teeth had six times more chances of presenting pulp canal obliteration that the mature teeth and a lower risk of developing root resorption. The most frequent post-injury complications were pulp necrosis (73.3%), marginal bone loss (60%), inflammatory root resorption (40%), pulp canal obliteration (26.7%) and replacement root resorption (20%). From the results of this study, it was not possible to determine whether the type immediate treatment had any influence on the appearance of sequelae like pulp necrosis and root resorption after intrusive luxation, but the existence of additional injuries and the stage of root development influenced the clinical case outcome in a negative and positive manner, respectively.
Resumo:
The aim of this study was to evaluate the presence of porosities inside the glass ionomer cement (GIC) after different techniques of material insertion. MATERIAL and METHOD: Specimens were prepared with high-viscosity GIC Ketac Molar Easymix and divided into three groups according to the insertion method: spatula (PI), Centrix injector (CI), and low-cost syringe (LCS). The specimens were fractured and observed with scanning electronic microscopy to quantitatively evaluate porosity inside the material using Image J Software. RESULTS: Statistical analysis, ANOVA application, and Tukey test to significance level of 5%, revealed that there was no statistical difference between the groups. CONCLUSION: Although the use of LCS has not decreased the porosity of the material, this insertion method is easy, accessible, and low cost, which makes it a viable alternative of use in the ART technique and in others bucal health programs. Microsc. Res. Tech., 2012. (c) 2012 Wiley Periodicals, Inc.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Microwave energy has proved to be an effective method for disinfecting acrylic dentures. However, the effect of microwave heating on the porosity of autopolymerising denture reline resins has not been investigated.The purpose of the study was to determine the effect of microwave disinfection on the porosity of autopolymerised denture reline materials (Kooliner-K, New Truliner-NT, Tokuso Rebase Fast-TR and Ufi Gel Hard-UGH) and a conventional heat-polymerised denture base resin (Lucitone 550-L).Specimens (10 mm x 20 mm x 1 mm) were obtained from the impression surface of the palatal mucosa in a single person and divided into four groups (n = 5). The porosity was evaluated after polymerisation (C1), after two cycles of microwave disinfection (MW2), after seven cycles of microwave disinfection (MW7) and after 7 days storage in water at 37 degrees C (C2). Specimens from group MW7 were exposed to microwave disinfection daily being stored in water at 37 degrees C between exposures. All the replicas were sputter coated with gold and micrographs/digital images were taken of each replica using scanning electron microscopy at magnification x 100. The SEM micrographs were then examined using an image analyser to determine the number of pores. Comparison between materials and groups were made using Kruskal-Wallis tests.MW7 resulted in a significant increase in the number from the pores of material K, but decreased in number in reline material TR and UGH reline resin. The number of pores in materials NT and L remained unaffected following microwave disinfection.Differences in the porosity amongst the materials and for different experimental conditions were observed following microwave disinfection.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Dental fluorosis is a developmental disturbance of dental enamel, caused by successive exposures to high concentrations of fluoride during tooth development, leading to enamel with lower mineral content and increased porosity. The severity of dental fluorosis depends on when and for how long the overexposure to fluoride occurs, the individual response, weight, degree of physical activity, nutritional factors and bone growth. The risk period for esthetic changes in permanent teeth is between 20 and 30 months of age. The recommended level for daily fluoride intake is 0.05 - 0.07 mg F/Kg/day, which is considered of great help in preventing dental caries, acting in remineralization. A daily intake above this safe level leads to an increased risk of dental fluorosis. Currently recommended procedures for diagnosis of fluorosis should discriminate between symmetrical and asymmetrical and/or discrete patterns of opaque defects. Fluorosis can be prevented by having an adequate knowledge of the fluoride sources, knowing how to manage this issue and therefore, avoid overexposure.
Resumo:
Objectives: To determine whether chewing side preference (CSP) is correlated to lateralities (handedness, footedness, eyedness and earedness) in primary, mixed and permanent dentitions.Design: Three-hundred subjects were divided into 3 groups: Group 1-100 children 3-5 years old, primary dentition; Group 2-100 children 6-12 years old, mixed dentition; Group 3 - 100 subjects 18-47 years old, permanent dentition. CSP was determined using a method developed by Mc Donnell et al.(9) Subjects were given a piece of gum and the position of the chewing gum was recorded 7 times as right or left. Subjects were classified as 'observed preferred chewing side' (OPCS) when they performed 5/7, 6/7 or 7/7 strokes on the same side. OPCS corresponded to the CSP. Laterality tests were performed for handedness, footedness, eyedness and earedness tasks. The Chi-square (chi(2)) and phi correlation (r) tests were used to investigate significant correlations between CSP and sidedness.Results: There was a significant correlation between chewing and earedness (p = 0.00), although there was weak positive correlation (r = 0.30) for primary dentition. There were significant correlations between chewing and handedness (p = 0.02; r = 0.25) and chewing and footedness (p = 0.02; r = 0.26), however, there were weak positive correlations for mixed dentition; there were significant correlations between chewing and handedness (p = 0.02; r = 0.26); chewing and footedness (p = 0.00; r = 0.33) and chewing and earedness (p = 0.01; r = 0.29); however, there were weak positive correlations for permanent dentition.Conclusion: It may be concluded that CSP can be significantly correlated with: earedness for primary dentition; handedness and footedness for mixed dentition; handedness, footedness and earedness for permanent dentition, but these are weak positive relationships. Future work on larger samples of left- and right-sided individuals is required to validate the findings. (C) 2012 Elsevier Ltd. All rights reserved.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Statement of problem. Two problems found in prostheses with resilient liners are bond failure to the acrylic resin base and increased permanent deformation due to material aging.Purpose. This in vitro study evaluated the effect of varying amounts of thermal cycling on bond strength and permanent deformation of 2 resilient denture liners bonded to an acrylic resin base.Material and methods. Plasticized acrylic resin (PermaSoft) or silicone (Softliner) resilient lining materials were processed to a heat-polymerized acrylic resin (QC-20). One hundred rectangular specimens (10 X 10-mm(2) cross-sectional area) and 100 cylindrically-shaped specimens (12.7-mm diameter X 19.0-mm height) for each liner/resin combination were used for the tensile and deformation tests, respectively. Specimen shape and liner thickness were standardized. Specimens were divided into 9 test groups (n=10) and were thermal cycled for 200, 500, 1000, 1500, 2000, 2500, 3000, 3500, and 4000 cycles. Control specimens (n=10) were stored for 24 hours in water at 37degreesC. Mean bond strength, expressed as stress at failure (MPa), was determined with a tensile test using a universal testing machine at a crosshead speed of 5 mm/min. Analysis of failure mode, expressed as a percent (%), was recorded as either cohesive, adhesive, or both, after observation. Permanent deformation, expressed as a percent (%), was determined using ADA specification no. 18. Data from both tests were examined with a 2-way analysis of variance and a Tukey test (alpha=.05).Results. For the tensile test, Softliner specimens submitted to different thermal cycling regimens demonstrated no significantly different bond strength values from the control; however, there was a significant difference between the PermaSoft control group (0.47 +/- 0.09 MPa [mean +/- SD]) and the 500 cycle group (0.46 +/- 0.07 MPa) compared to the 4000 cycle group (0.70 +/- 0.20 MPa) (P<.05). With regard to failure type, the Softliner groups presented adhesive failure (100%) regardless of specimen treatment. PermaSoft groups presented adhesive (53%), cohesive (12%), or a combined mode of failure (35%). For the deformation test, there was no significant difference among the Softliner specimens. However, a significant difference was observed between control and PermaSoft specimens after 1500 or more cycles (1.88% +/- 0.24%) (P<.05).Conclusions. This in vitro study indicated that bond strength and permanent deformation of the 2 resilient denture liners tested varied according to their chemical composition.
Resumo:
A tungsten carbide coating on the integrated platform of a transversely heated graphite atomizer (THGA((R))) used together with Pd(NO3)(2) + Mg(NO3)(2) as modifier is proposed for the direct determination of lead in vinegar by graphite furnace atomic absorption spectrometry. The optimized heating program (temperature, ramp time, hold time) of atomizer involved drying stage (110 degrees C, 5 s, 30 s; 130 degrees C, 5 s, 30 s), pyrolysis stage (1000 degrees C, 15 s, 30 s), atomization stage (1800 degrees C, 0 s, 5 s) and clean-out stage (2450 degrees C, I s, 3 s). For 10 mu L of vinegar delivered into the atomizer and calibration using working standard solutions (2.5-20.0 mu g L-1 Pb) in 0.2% (v/v) HNO3, analytical curve with good linear correlation (r = 0.9992) was established. The characteristic mass was 40 pg Pb and the lifetime of the tube was around 730 firings. The limit of detection (LOD) was 0.4 mu g L-1 and the relative standard deviations (n = 12) were typically <8% for a sample containing 25 pg L-1 Pb. Accuracy of the proposed method was checked after direct analysis of 23 vinegar samples. A paired t-test showed that results were in agreement at 95% confidence level with those obtained for acid-digested vinegar samples. The Pb levels varied from 2.8 to 32.4 pg L-1. Accuracy was also checked by means of addition/recovery tests and recovered values varied from 90% to 110%. Additionally, two certified reference materials were analyzed and results were in agreement with certified values at a 95% confidence level. (C) 2006 Elsevier Ltd. All rights reserved.