929 resultados para Outbreak voltage
Resumo:
A cross-sectional study was performed to estimate the prevalence of slaughter pigs infected by Salmonella typhimurium after an enterocolitis outbreak in a commercial pig farm, which was characterised by diarrhoea during the growing phase. Anatomopathological and histopathological findings were suggestive of salmonellosis, which was further confirmed by isolation of S. typhimurium from organs and faeces samples from diseased animals. Ileocolic lymph nodes were aseptically collected from 43 pigs during slaughter procedures. The estimated prevalence of Salmonella-infected pigs was 53.48% [confidence interval (CI): 42.94:64.02%]. This finding demonstrates that the carriage of S. typhimurium at slaughter might be high if pigs originate from a batch previously affected by Salmonella-enterocolitis outbreak at the pre-harvest pork production chain. (c) 2005 Elsevier B.V. All rights reserved.
Resumo:
This gaper demonstrates that artificial neural networks can be used effectively for estimation of parameters related to study of atmospheric conditions to high voltage substations design. Specifically, the neural networks are used to compute the variation of electrical field intensity and critical disruptive voltage in substations taking into account several atmospheric factors, such as pressure, temperature, humidity, so on. Examples of simulation of tests are presented to validate the proposed approach. The results that were obtained by experimental evidences and numerical simulations allowed the verification of the influence of the atmospheric conditions on design of substations concerning lightning.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
This paper presents an analysis of a novel pulse-width-modulated (PWM) voltage step-down/up Zeta converter, featuring zero-current-switching (ZCS) at the active switches. The applications in de to de and ac to de (rectifier) operation modes are used as examples to illustrate the performance of this new ZCS-PWM Zeta converter. Regarding to the new ZCS-PWM Zeta rectifier proposed, it should be noticed that the average-current mode control is used in order to obtain a structure with high power-factor (HPF) and low total harmonic distortion (THD) at the input current.Two active switches (main and auxiliary transistors), two diodes, two small resonant inductors and one small resonant capacitor compose the novel ZCS-PWM soft-commutation cell, used in these new ZCS-PWM Zeta converters. In this cell, the turn-on of the active switches occurs in zero-current (ZC) and their turn-off in zero-current and zero-voltage (ZCZV). For the diodes, their turn-on process occurs in zero-voltage (ZV) and their reverse-recovery effects over the active switches are negligible. These characteristics make this cell suitable for Insulated-Gate Bipolar Transistors (IGBTs) applications.The main advantages of these new Zeta converters, generated from the new soft-commutation cell proposed, are possibility of obtaining isolation (through their accumulation inductors), and high efficiency, at wide load range. In addition, for the rectifier application, a high power factor and low THD in the input current ran be obtained, in agreement with LEC 1000-3-2 standards.The principle of operation, the theoretical analysis and a design example for the new de to de Zeta converter operating in voltage step-down mode are presented. Experimental results are obtained from a test unit with 500W output power, 110V(dc) output voltage, 220V(dc) input voltage, operating at 50kHz switching frequency. The efficiency measured at rated toad is equal to 97.3%for this new Zeta converter.Finally, the new Zeta rectifier is analyzed, and experimental results from a test unit rated at 500W output power, 110V(dc) output voltage, 220V(rms) input voltage, and operating at 50kHz switching frequency, are presented. The measured efficiency is equal to 96.95%, the power-factor is equal to 0.98, and the input current THD is equal to 19.07%, for this new rectifier operating at rated load.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
This work presents an approach for geometric solution of an optimal power flow (OPF) problem for a two bus system (a slack and a PV busses). Additionally, the geometric relationship between the losses minimization and the increase of the reactive margin and, therefore, the maximum loading point, is shown. The algebraic equations for the calculation of the Lagrange multipliers and for the minimum losses value are obtained. These equations are used to validate the results obtained using an OPF program. (C) 2002 Elsevier B.V. B.V. All rights reserved.
Resumo:
An analog synthesizer of orthogonal signals for digital CMOS technology and 3V supply voltage is presented. The adaptive architecture accomplishes the synthesis of mutually orthogonal signal, such as trigonometric and polynomial basis. Experimental results using 0.35 mu m AMS CMOS process are presented for generation of the cosine and Legendre basis.
Resumo:
An analog synthesizer of orthogonal signals for digital CMOS technology and 3V supply voltage is presented. The adaptive architecture accomplishes the synthesis of mutually orthogonal signal, such as trigonometric and polynomial basis. Simulation results using 0.35 mu m AMS CMOS process are presented for generation of the cosine and Legendre basis.
Resumo:
A novel single-phase voltage source rectifier capable to achieve High-Power-Factor (HPF) for variable speed refrigeration system application, is proposed in this paper. The proposed system is composed by a single-phase high-power-factor boost rectifier, with two cells in interleave connection, operating in critical conduction mode, and employing a soft-switching technique, controlled by a Field Programmable Gate Array (FPGA), associated with a conventional three-phase IGBT bridge inverter (VSI - Voltage Source Inverter), controlled by a Digital Signal Processor (DSP). The soft-switching technique for the input stage is based on zero-current-switching (ZCS) cells. The rectifier's features include the reduction in the input current ripple, the reduction in the output voltage ripple, the use of low stress devices, low volume for the EMI input filter, high input power factor (PF), and low total harmonic distortion (THD) in the input current, in compliance with the EEC61000-3-2 standards. The digital controller for the output stage has been developed using a conventional voltage-frequency control (scalar V/f control), and a simplified stator oriented Vector control, in order to verify the feasibility and performance of the proposed digital controls for continuous temperature control applied at a refrigerator prototype.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Biopsy by fine needle aspiration together with microbiological examination and scanning electron microscopy were evaluated in diagnosis of clinical bovine mastitis in a Prototheca zopfii outbreak. Fine needle aspiration was performed in 21 mammary quarters from ten Holstein cows presenting clinical mastitis caused by P. zopfii. The algae were previously identified in the microbiological examination of milk collected from these cows. Material aspirated from these 21 mammary glands was submitted to cytological staining (Gram, Giemsa and/or Shor staining). Fine needle aspiration enabled cytological identification of the algae in these 21 mammary glands, from which P. zopfii was isolated in the milk. Simultaneously, five mammary fragments collected by fine needle aspiration from these 21 mammary glands presenting clinical mastitis were also submitted to microbiological examination. P. zopfii was also isolated from these five fragments. Scanning electron microscopy technique also identified three of these five P. zopfii strains isolated from mammary fragments collected by cytological aspiration. These results suggest that fine needle aspiration may be an alternative method for the diagnosis of clinical mastitis.
Resumo:
Esta é a primeira descrição de um surto de Trypanosomavivax ocorrido no Estado de São Paulo, no município de Lins. Animais acometidos apresentaram febre, icterícia, diminuição da produção de leite, perda de peso, diarreia profusa, abortos, anemia, leucocitose e hiperfibrigenemia. Foram registrados 31 óbitos de vacas e bezerros em 1.080 bovinos no total. Três vacas apresentaram sintomatologia nervosa, como dismetria, ataxia e fraqueza muscular, além de ptialismo, aumento de linfonodos e edema submandibular. Hemoparasitas flagelados foram observados em esfregaços sanguíneos, e a espécie de tripanossomo foi diagnosticada como T.vivax por PCR. A cepa de T. vivax mostrou ser resistente ao tratamento com aceturato de diaminozeno e a infecção disseminou rapidamente no rebanho. Pelo ELISA, observou-se que 98,36% (599) das amostras de soro colhidas apresentaram títulos positivos para IgG anti-T.vivax. O surto ocorreu em condições de baixa precipitação pluviométrica, fato que indica que outros fatores estavam envolvidos na ocorrência desse surto, como a ausência de tabanídeos e a grande presença de Haematobia irritans e Stomoxys calcitrans, cujo aumento populacional pode ser devido ao uso de resíduos de usinas de açúcar e álcool nos canaviais que circundavam a granja leiteira.