466 resultados para Orthopaedic


Relevância:

10.00% 10.00%

Publicador:

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Development of novel implants in orthopaedic trauma surgery is based on limited datasets of cadaver trials or artificial bone models. A method has been developed whereby implants can be constructed in an evidence based method founded on a large anatomic database consisting of more than 2.000 datasets of bones extracted from CT scans. The aim of this study was the development and clinical application of an anatomically pre-contoured plate for the treatment of distal fibular fractures based on the anatomical database. 48 Caucasian and Asian bone models (left and right) from the database were used for the preliminary optimization process and validation of the fibula plate. The implant was constructed to fit bilaterally in a lateral position of the fibula. Then a biomechanical comparison of the designed implant to the current gold standard in the treatment of distal fibular fractures (locking 1/3 tubular plate) was conducted. Finally, a clinical surveillance study to evaluate the grade of implant fit achieved was performed. The results showed that with a virtual anatomic database it was possible to design a fibula plate with an optimized fit for a large proportion of the population. Biomechanical testing showed the novel fibula plate to be superior to 1/3 tubular plates in 4-point bending tests. The clinical application showed a very high degree of primary implant fit. Only in a small minority of cases further intra-operative implant bending was necessary. Therefore, the goal to develop an implant for the treatment of distal fibular fractures based on the evidence of a large anatomical database could be attained. Biomechanical testing showed good results regarding the stability and the clinical application confirmed the high grade of anatomical fit.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Femoroacetabular impingement is recognized as a major cause of hip pain and early hip joint osteoarthritis in young adults. The dynamic conflict between the femoral neck and the acetabular rim has been shown to result in labral tears, cartilage lesions, and early osteoarthritis. To be successful, the treatment strategy should address the underlying pathomorphology at the femoral neck, the acetabulum, or both. An overview of the various pathomorphologies leading to femoroacetabular impingement and a treatment algorithm intended to preserve the native hip joint should be helpful to the orthopaedic surgeon treating patients with this condition.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The objectives of this study were to establish dose-response and blood concentration-response relationships for robenacoxib, a novel nonsteroidal anti-inflammatory drug with selectivity for inhibition of the cyclooxygenase (COX)-2 isoenzyme, in a canine model of synovitis. Acute synovitis of the stifle joint was induced by intra-articular injection of sodium urate crystals. Robenacoxib (0.25, 0.5, 1.0, 2.0 and 4.0 mg/kg), placebo and meloxicam (0.2 mg/kg) were administered subcutaneously (s.c.) 3 h after the urate crystals. Pharmacodynamic endpoints included data from forceplate analyses, clinical orthopaedic examinations and time course of inhibition of COX-1 and COX-2 in ex vivo whole blood assays. Blood was collected for pharmacokinetics. Robenacoxib produced dose-related improvement in weight-bearing, pain and swelling as assessed objectively by forceplate analysis (estimated ED(50) was 1.23 mg/kg for z peak force) and subjectively by clinical orthopaedic assessments. The analgesic and anti-inflammatory effects of robenacoxib were significantly superior to placebo (0.25-4 mg/kg robenacoxib) and were non-inferior to meloxicam (0.5-4 mg/kg robenacoxib). All dosages of robenacoxib produced significant dose-related inhibition of COX-2 (estimated ED(50) was 0.52 mg/kg) but no inhibition of COX-1. At a dosage of 1-2 mg/kg administered s.c., robenacoxib should be at least as effective as 0.2 mg/kg of meloxicam in suppressing acute joint pain and inflammation in dogs.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Identification of the subarachnoid space has traditionally been achieved by either a blind landmark-guided approach or using prepuncture ultrasound assistance. To assess the feasibility of performing spinal anaesthesia under real-time ultrasound guidance in routine clinical practice we conducted a single center prospective observational study among patients undergoing lower limb orthopaedic surgery. A spinal needle was inserted unassisted within the ultrasound transducer imaging plane using a paramedian approach (i.e., the operator held the transducer in one hand and the spinal needle in the other). The primary outcome measure was the success rate of CSF acquisition under real-time ultrasound guidance with CSF being located in 97 out of 100 consecutive patients within median three needle passes (IQR 1-6). CSF was not acquired in three patients. Subsequent attempts combining landmark palpation and pre-puncture ultrasound scanning resulted in successful spinal anaesthesia in two of these patients with the third patient requiring general anaesthesia. Median time from spinal needle insertion until intrathecal injection completion was 1.2 minutes (IQR 0.83-4.1) demonstrating the feasibility of this technique in routine clinical practice.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Cerclages regain interest due to a rising number of periprosthetic fractures. The contact distribution at the circumferential cerclage-bone interface is still unknown. Local interface pressure depends on the amount of contact area. Cortical damage at the interface would provoke cerclage loosening. Therefore, the contact area, the bone pressure along the interface and the cortical resistance underneath loaded cerclages were determined in an ex vivo model.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

End-stage ankle arthritis is operatively treated with numerous designs of total ankle replacement and different techniques for ankle fusion. For superior comparison of these procedures, outcome research requires a classification system to stratify patients appropriately. A postoperative 4-type classification system was designed by 6 fellowship-trained foot and ankle surgeons. Four surgeons reviewed blinded patient profiles and radiographs on 2 occasions to determine the interobserver and intraobserver reliability of the classification. Excellent interobserver reliability (κ = .89) and intraobserver reproducibility (κ = .87) were demonstrated for the postoperative classification system. In conclusion, the postoperative Canadian Orthopaedic Foot and Ankle Society (COFAS) end-stage ankle arthritis classification system appears to be a valid tool to evaluate the outcome of patients operated for end-stage ankle arthritis.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

To classify the fracture patterns of gunshot wounds to the acetabulum; identify the associated injuries and complications; determine the predictors of poor outcome and deep infection; and propose a treatment algorithm based on the results.

Relevância:

10.00% 10.00%

Publicador:

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Limitations in the use of autologous bone graft, which is the gold standard therapy in bone defect healing, drive the search for alternative treatments. In this study the influence of rhTGFbeta-3 on mechanical and radiological parameters of a healing bone defect in the sheep tibia was assessed. In the sheep, an 18-mm long osteoperiosteal defect in the tibia was treated by rhTGFbeta-3 seeded on a poly(L/DL-lactide) carrier (n = 4). In a second group (n = 4), the defect was treated by the carrier only, in a third group (n = 4) by autologous cancellous bone graft, and in a fourth group (n = 2) the defect remained blank. The healing process of the defect was assessed by weekly in vivo stiffness measurements and radiology as well as by quantitative computed tomographic assessment of bone mineral density (BMD) every 4 weeks. The duration of the experiment was 12 weeks under loading conditions. In the bone graft group, a marginally significant higher increase in stiffness was observed than in the PLA/rhTGFbeta-3 group (p = 0.06) and a significantly higher increase than in the PLA-only group (p = 0.03). The radiographic as well as the computed tomographic evaluation yielded significant differences between the groups (p = 0.03), indicating the bone graft treatment (bone/per area, 83%; BMD, 0.57 g/cm(3)) performing better than the PLA/rhTGFbeta-3 (38%; 0.23 g/cm(3)) and the PLA-only treatment (2.5%; 0.09 g/cm(3)), respectively. Regarding the mechanical and radiological parameters assessed in this study, we conclude that rhTGFbeta-3 has a promoting effect on bone regeneration. However, under the conditions of this study, this effect does not reach the potential of autologous cancellous bone graft transplantation.