969 resultados para Minimally invasive approach


Relevância:

80.00% 80.00%

Publicador:

Resumo:

Treatment of arterial traumatic intimal lesions is controversial due to its unknown natural history. Current therapeutical options include arterial reconstruction and clinical observation. The idea of using stents to correct intimal flaps is based on their use to correct dissections, flaps, and arterial irregularities after angioplasty. We report the successful treatment of a traumatic intimal flap of the superficial femoral artery, caused by gunshot trauma, with a Palmaz stent in the acute period. One year after the operation, a duplex scan revealed normal flow in the artery and complete exclusion of the intimal flap; distal pulses were palpable, and the patient was completely asymptomatic.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Splenectomy is the best available treatment for severe forms of hereditary spherocytosis, idiopathic thrombocytopenic purpura, and other hematologic conditions when these prove refractory to conservative management. It has been employed for many decades with low mortality and favorable remission rates. The use of laparoscopic splenectomy in recent years has been rapidly and even enthusiastically adopted in this field. However, the exact role of laparoscopic versus open surgery for hematologic diseases is still debated. In this study of 58 adult patients, laparoscopic procedures were compared with conventional splenectomies for similar indications. METHODS: All patients were operated on within an 8-year period. Subjects underwent similar procedures under the supervision of the same surgical school and were compared regarding age, gender, body mass index, and diagnosis. Laparoscopically managed cases (Group I, n = 30) were prospectively followed according to a written protocol, whereas the same investigation was retrospectively done with regard to traditional laparotomy (Group II, n = 28). Methods included general and demographic findings, duration and technical steps of operation, blood loss, weight of spleen, need for conversion (in minimally invasive subjects), intraoperative and postoperative complications, time until realimentation, postoperative hospitalization, mortality, and late follow-up including recurrence rate. RESULTS: Idiopathic thrombocytopenic purpura was the surgical indication in over 50% of the patients in both groups, but familial spherocytosis, thalassemia, myelodysplasia, and lymphomas were also represented in this series. Laparoscopic procedures took more time to perform (P = 0.004), and postoperative hospitalization was 2 days shorter, but this difference was not statistically significant. Postoperative hematocrit and volume of blood transfusions was equivalent, although the laparoscopic cases had a somewhat lower preoperative hematocrit (NS) and displayed better recovery for this measurement (P = 0.03). More patients in Group I were able to accept oral food on the first day than subjects undergoing conventional operations (P < 0.05). Relatively few conversions were necessary during the minimally invasive surgeries (13.3%), and postoperative early and late complications as well as recurrences occurred in similar proportions. Also, the mean weight of the spleen was not statistically different between the groups, although there was a marked numerical tendency toward larger masses in conventional procedures. No spleen in Group I exceeded 2.0 kg, whereas in Group II values up to 4.0 kg occurred, and the mean weight was 50% higher in the latter group. CONCLUSIONS: 1) Minimally invasive splenectomy was essentially comparable to open surgery with regard to safety, efficacy, and late results; 2) Advantages concerning shorter postoperative hospitalization could not be shown, despite earlier food intake and a non-significant tendency toward earlier discharge; 3) This new modality should be considered an option in cases of hematologic conditions whenever the spleen is not hugely enlarged.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Bioactive glass nanoparticles (BGNPs) promote an apatite surface layer in physiologic conditions that lead to a good interfacial bonding with bone.1 A strategy to induce bioactivity in non-bioactive polymeric biomaterials is to incorporate BGNPs in the polymer matrix. This combination creates a nanocomposite material with increased osteoconductive properties. Chitosan (CHT) is a polymer obtained by deacetylation of chitin and is biodegradable, non-toxic and biocompatible. The combination of CHT and the BGNPs aims at designing biocompatible spheres promoting the formation of a calcium phosphate layer at the nanocomposite surface, thus enhancing the osteoconductivity behaviour of the biomaterial. Shape memory polymers (SMP) are stimuli-responsive materials that offer mechanical and geometrical action triggered by an external stimulus.2 They can be deformed and fixed into a temporary shape which remains stable unless exposed to a proper stimulus that triggers recovery of their original shape. This advanced functionality makes such SMPs suitable to be implanted using minimally invasive surgery procedures. Regarding that, the inclusion of therapeutic molecules becomes attractive.  We propose the synthesis of shape memory bioactive nanocomposite spheres with drug release capability.3   1.  L. L. Hench, Am. Ceram. Soc. Bull., 1993, 72, 93-98. 2.  A. Lendlein and S. Kelch, Angew Chem Int Edit, 2002, 41, 2034-2057. 3.  Ã . J. Leite, S. G. Caridade and J. F. Mano, Journal of Non-Crystalline Solids (in Press)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

OBJECTIVE: To assess the results observed during the early postoperative period in patients who had the posterior coronary arteries revascularized without cardiopulmonary bypass (CPB), in regard to the following parameters: age, sex,bypass grafts types, morbidity and mortality. METHODS: From January 1995 to June 1998, 673 patients underwent myocardial revascularization (MR). Of this total, 607 (90.20%) MR procedures were performed without CPB. The posterior coronary arteries (PCA) were revascularized in 298 (44.27%) patients, 280 (93.95%) without CPB. The age of the patients ranged from 37 to 88 years (mean, 61 years). The male gender predominated, with 198 men (70.7%). The revascularization of the posterior coronary arteries had the following distribution: diagonalis artery (31 patients, 10%); marginal branches of the circumflex artery (243 patients, 78.7%); posterior ventricular artery (4 patients, 1.3%); and posterior descending artery (31 patients, 10%). RESULTS: Procedure-related complications without death occurred in 7 cases, giving a morbidity of 2.5%. There were 11 deaths in the early postoperative period (mortality of 3.9%). CONCLUSION: Similarly to the anterior coronary arteries, the posterior coronary arteries may benefit from myocardial revascularization without CPB.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

BACKGROUND: Early detection and treatment of colorectal adenomatous polyps (AP) and colorectal cancer (CRC) is associated with decreased mortality for CRC. However, accurate, non-invasive and compliant tests to screen for AP and early stages of CRC are not yet available. A blood-based screening test is highly attractive due to limited invasiveness and high acceptance rate among patients. AIM: To demonstrate whether gene expression signatures in the peripheral blood mononuclear cells (PBMC) were able to detect the presence of AP and early stages CRC. METHODS: A total of 85 PBMC samples derived from colonoscopy-verified subjects without lesion (controls) (n = 41), with AP (n = 21) or with CRC (n = 23) were used as training sets. A 42-gene panel for CRC and AP discrimination, including genes identified by Digital Gene Expression-tag profiling of PBMC, and genes previously characterised and reported in the literature, was validated on the training set by qPCR. Logistic regression analysis followed by bootstrap validation determined CRC- and AP-specific classifiers, which discriminate patients with CRC and AP from controls. RESULTS: The CRC and AP classifiers were able to detect CRC with a sensitivity of 78% and AP with a sensitivity of 46% respectively. Both classifiers had a specificity of 92% with very low false-positive detection when applied on subjects with inflammatory bowel disease (n = 23) or tumours other than CRC (n = 14). CONCLUSION: This pilot study demonstrates the potential of developing a minimally invasive, accurate test to screen patients at average risk for colorectal cancer, based on gene expression analysis of peripheral blood mononuclear cells obtained from a simple blood sample.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

BACKGROUND: Robot surgery is a further step towards new potential developments in minimally invasive surgery. Surgeons must keep abreast of these new technologies and learn their limits and possibilities. Robot-assisted laparoscopic cholecystectomy has not yet been performed in our institution. The purpose of this report is to present the pathway of implementation of robotic laparoscopic cholecystectomy in a university hospital. METHODS: The Zeus(R) robot system was used. Experimental training was performed on animals. The results of our experimental training allowed us to perform our first two clinical cases. RESULTS: Robot arm set-up and trocar placement required 53 and 35 minutes. Operative time were 59 and 45 minutes respectively. The overall operative time was 112 and 80 minutes, respectively. There were no intraoperative complications. Patients were discharged from the hospital after an overnight stay. CONCLUSION: Robotic laparoscopic cholecystectomy is safe and patient recovery similar to those of standard laparoscopy. At present, there are no advantages of robotic over conventional surgery. Nevertheless, robots have the potential to revolutionise the way surgery is performed. Robot surgery is not reserved for a happy few. This technology deserves more attention because it has the potential to change the way surgery is performed.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

2007 was marked by a growing trend towards minimal invasive surgery and enhanced recovery, especially in visceral surgery. In comparison to the laparoscopic revolution in the eighties, Natural orifice transluminal endoscopic surgery (NOTES) must be watched on closely, and will probably have to be taken into account in a near future. Minimal invasive procedures in oesophageal cancer surgery have proved both efficient and oncologically safe. Implementation of Fast track protocols now permits a much faster patient's return to normal daily activity. In hepatobiliary and pancreatic surgery, multidisciplinary efforts have been done to better select patients, widen the indications and increase efficiency.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

PURPOSE: Transanal endoscopic microsurgery provides a minimally invasive alternative to radical surgery for excision of benign and malignant rectal tumors. The purpose of this study was to review our experience with transanal endoscopic microsurgery to clarify its role in the treatment of different types of rectal pathology. METHODS: A prospective database documented all patients undergoing transanal endoscopic microsurgery from October 1996 through June 2008. We analyzed patient and operative factors, complications, and tumor recurrence. For recurrence analysis, we excluded patients with fewer than 6 months of follow-up, previous excisions, known metastases at initial presentation, and those who underwent immediate radical resection following transanal endoscopic microsurgery. RESULTS: Two hundred sixty-nine patients underwent transanal endoscopic microsurgery for benign (n = 158) and malignant (n = 111) tumors. Procedure-related complications (21%) included urinary retention (10.8%), fecal incontinence (4.1%), fever (3.8%), suture line dehiscence (1.5%), and bleeding (1.5%). Local recurrence rates for 121 benign and 83 malignant tumors were 5% for adenomas, 9.8% for T1 adenocarcinoma, 23.5% for T2 adenocarcinoma, 100% for T3 adenocarcinoma, and 0% for carcinoid tumors. All 6 (100%) recurrent adenomas were retreated with endoscopic techniques, and 8 of 17 (47%) recurrent adenocarcinomas underwent salvage procedures with curative intent. CONCLUSIONS: Transanal endoscopic microsurgery is a safe and effective method for excision of benign and malignant rectal tumors. Transanal endoscopic microsurgery can be offered for (1) curative resection of benign tumors, carcinoid tumors, and select T1 adenocarcinomas, (2) histopathologic staging in indeterminate cases, and (3) palliative resection in patients medically unfit or unwilling to undergo radical resection.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Transmembrane receptor-kinases are widespread throughout eukaryotes and their activities are known to regulate all kinds of cellular responses in diverse organs and cell types. In order to guarantee the correct amplitude and duration of signals, receptor levels at the cellular surface need to be tightly controlled. The regulation of receptor degradation is the most direct way to achieve this and elaborate mechanisms are in place to control this process. Therefore, the rate of receptor degradation is a parameter of central importance for understanding the dynamics of a signal transduction cascade. Unfortunately, degradation of transmembrane receptors is a complicated multistep process that involves internalization from the plasma membrane, invagination into the lumen of endosomal compartments, and finally fusion with the vacuole for degradation by vacuolar proteases. Therefore, degradation should be measured in an as noninvasive way as possible, such as not to interfere with the complicated transport processes. Here, a method for minimally invasive, in vivo turn-over measurements in intact organs is provided. This technique was used for quantifying the turn-over rates of the Brassinosteroid receptor kinase BRI1 (BRASSINOSTEROID INSENSITIVE 1) in Arabidopsis thaliana root meristems. Pulse-chase expression of a fluorescently labeled BRI1 variant was used and its turn-over rate was determined by quantitative confocal microscopy. This method is well suited to measure turn-over of transmembrane kinases, but can evidently be extended to measure turn-over of any types of transmembrane proteins.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

We investigated the use of in situ implant formation that incorporates superparamagnetic iron oxide nanoparticles (SPIONs) as a form of minimally invasive treatment of cancer lesions by magnetically induced local hyperthermia. We developed injectable formulations that form gels entrapping magnetic particles into a tumor. We used SPIONs embedded in silica microparticles to favor syringeability and incorporated the highest proportion possible to allow large heating capacities. Hydrogel, single-solvent organogel and cosolvent (low-toxicity hydrophilic solvent) organogel formulations were injected into human cancer tumors xenografted in mice. The thermoreversible hydrogels (poloxamer, chitosan), which accommodated 20% w/v of the magnetic microparticles, proved to be inadequate. Alginate hydrogels, however, incorporated 10% w/v of the magnetic microparticles, and the external gelation led to strong implants localizing to the tumor periphery, whereas internal gelation failed in situ. The organogel formulations, which consisted of precipitating polymers dissolved in single organic solvents, displayed various microstructures. A 8% poly(ethylene-vinyl alcohol) in DMSO containing 40% w/v of magnetic microparticles formed the most suitable implants in terms of tumor casting and heat delivery. Importantly, it is of great clinical interest to develop cosolvent formulations with up to 20% w/v of magnetic microparticles that show reduced toxicity and centered tumor implantation.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Anterior and middle skull base tumors, mainly meningiomas, are usually operated on using a sub-frontal route with a microscope. With modern radiotherapy, the goal of skull base surgery moves from a radical surgery with high rate of side effect to a functional concept that aims to remove as much as possible of the tumor without compromising the neurological status of patients. Minimally skull base surgery benefits from keyhole and endoscopy techniques. For 3 2 decades, the development of endoscopy helps to imagine innovative approaches for skull base tumors such as the endonasal route. Nonetheless, CSF leak issue and the absence of direct control of the tumor margins may limit the interest of such a route. Keyhole craniotomies have been developed with microscope but vision issue limits their use. Combining advantages of both techniques appears therefore natural and gave birth to intracranial assisted and more recently to fully endoscopic keyhole surgery. For anterior or middle skull base tumors, Keyhole supraorbital approaches can be done either by a trans-eyebrow or trans-eyelid routes. A step-by-step description of these fully endoscopic alternative routes summarizing advantages and drawbacks compared to others (traditional sub-frontal or more recent endonasal approaches) is reported in this chapter by the authors.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Purpose of reviewThis review provides information and an update on stereotactic radiosurgery (SRS) equipment, with a focus on intracranial lesions and brain neoplasms.Recent findingsGamma Knife radiosurgery represents the gold standard for intracranial radiosurgery, using a dedicated equipment, and has recently evolved with a newly designed technology, Leksell Gamma Knife Perfexion. Linear accelerator-based radiosurgery is more recent, and originally based on existing systems, either adapted or dedicated to radiosurgery. Equipment incorporating specific technologies, such as the robotic CyberKnife system, has been developed. Novel concepts in radiation therapy delivery techniques, such as intensity-modulated radiotherapy, were also developed; their integration with computed tomography imaging and helical delivery has led to the TomoTherapy system. Recent data on the management of intracranial tumors with radiosurgery illustrate the trend toward a larger use and acceptance of this therapeutic modality.SummarySRS has become an important alternative treatment for a variety of lesions. Each radiosurgery system has its advantages and limitations. The 'perfect' and ubiquitous system does not exist. The choice of a radiosurgery system may vary with the strategy and needs of specific radiosurgery programs. No center can afford to acquire every technology, and strategic choices have to be made. Institutions with large neurosurgery and radiation oncology programs usually have more than one system, allowing optimization of the management of patients with a choice of open neurosurgery, radiosurgery, and radiotherapy. Given its minimally invasive nature and increasing clinical acceptance, SRS will continue to progress and offer new advances as a therapeutic tool in neurosurgery and radiotherapy.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

BACKGROUND: An animal study was carried out to compare long-term patency rates of coronary anastomoses performed with the GraftConnector versus running suture technique. METHODS: 10 sheep, 45 to 55 kg, underwent off-pump coronary artery bypass grafting (right internal mammary artery to left anterior descending artery). In 5 animals, the anastomosis was performed with a GraftConnector and in 5 animals with 7-0 running suture. Intraoperative fluoroscopy and a fluoroscopic control at 6 months were performed. After 6 months, the animals were sacrificed and the anastomoses were examined histologically. RESULTS: All animals survived at 6 months with 100% anastomosis patency rates in both groups. In the GraftConnector group, the anastomosis diameter at 6 months fluoroscopy was 118% of native left anterior descending artery versus 97% of the control group. Luminal anastomotic width at histology was 1.7 +/- 0.2 mm in the device group versus 1.6 +/- 0.1 mm in the control group. Mean intimal hyperplasia thickness was 0.21 +/- 0.1 mm in the device group versus 0.01 mm in the control group. CONCLUSIONS: The GraftConnector provides a consistent and reproducible coronary artery anastomosis and reduces technical demand and manual dexterity in coronary operations. Long-term results demonstrate that off-pump coronary artery bypass grafting performed with the GraftConnector had the same patency rate and luminal width as those performed with running suture.