471 resultados para Medici
Resumo:
Purpose: To evaluate the accuracy of approximal caries detection comparing enhanced and unenhanced Sidexis CCD-based digital image with Ektaspeed Plus and INSIGHT films. Methods: Fifty-two extracted premolars were imaged under identical standardized geometric and exposure conditions. Four observers, using five points confidence scale, rated 104 approximal surfaces for the presence or absence of carious lesions by means of four image modalities: (1) observer enhanced; (2) unenhanced Sidexis displays; (3) E speed films and (4) F speed film. Histologic sections served as validating criterion for the presence and depth of carious lesions. Diagnostic accuracy was measured as the area beneath the ROC curve. Results: Mean ROC (receiver operating characteristic) curve areas for approximal surfaces were 0.865 (E speed), 0.856 (F speed), 0.816 (unenhanced Sidexis) and 0.776 (observer enhanced). There were no significant differences between unenhanced digital Sidexis and films. Observer enhanced Sidexis images exhibited a statistically significant lower diagnostic accuracy than the film images for two of the observers.
Resumo:
This paper analyses the dew occurrence in Botucatu, Sao Paulo State, Brazil, in the period from 1971 to 1984. The phenomenon was observed on the grass plot of the Climatological Station in the 'Presidente Medici' Experimental Farm. The station is installed on soil 'Terra Roxa Estruturada', on a middle slope, declivity of 8% and east exposure. Days with dew were summed for the following periods: month, year, season, no rainy period and rainy period. For each period the following values were calculated: mean, mean standard errors and mean confidence interval. Also the absolute extreme values and the amplitude of variation were determined. The confidence interval of the mean were calculated by the 't' statistic, at the level of 5% of error probability. The means were compared by using the 't' statistic, at the level of 5% of error probability. The following table of values corresponds to the regime of dew occurrence in Botucatu, expressed in number of days with dew. The dew occurrence regime in Botucatu was analysed comparatively with the regime at Itatinga, in Sao Paulo State and with the regime of Rio Grande, in Rio Grande do Sul State. -English summary
Resumo:
In a sample of Brazilian white young adults between 18-23 years old, the A.A. studied the third molar roots, in anatomical aspects, using the orthopantomographic radiographic method. They concluded that the superior third molar shows a biggest number of fusionated roots (19.50% in the right side and 19.66% in the left side) and the inferior third molar shows a biggest number of separated roots (21.48% in the right side and 19.66% in the left side).
Resumo:
The purpose of this article was to compare the mean value of optical density of four porcelains commonly used for fabrication of inlay/ onlay prostheses using direct digital radiograph. The sample consisted of 20 2-mm thick porcelain specimens (measured by digital pachymeter): Empress (Ivoclair), Simbios (Degussa), Vita Omega 900 and Vitadur Alpha (Vita Zahnfabrik). The values of optical density of the specimens were expressed in millimeters aluminum equivalent (mm eq Al). The samples were X-rayed using two charge coupled devices (CCD) - RVG (Trophy) - Visualix (Gendex) and a phosphor plate system - Digora (Soredex). The optical density reading was performed with Image Tool 1.28 in a total of 110 measurements. Statistical analysis showed that there were statistically significant differences in all materials studied (p < 0.05) regardless of the radiographic system used. The highest optical density value was found for Omega 900 (1.8988 mmeqAl - Visualix - Gendex) and the lowest for Vitadur Alpha (0.8647 - Visualix - Gendex). Thus, the material presenting the highest degree of optical density was Omega 900, Empress and Simbios presented intermediate optical density values, Vitadur Alpha presented the lowest value, and the optical density of porcelains was not influenced by the digital radiography systems.
Resumo:
The reproducibility of measurements of alveolar bone loss on radiographs may be a problem on epidemiologic studies, as they are based on comparisons of the diagnosis of various examiners. The aim of the present research paper was to assess the inter- and intra-examiner reproducibility of measurements of the interproximal alveolar bone loss on non-manipulated digital radiographs and after the application of image filters. Five Oral Radiologists measured the distance between the cementoenamel junction (CEJ) to the alveolar crest or to the deepest point of the bony defect on 12 interproximal digital radiographs of molars and bicuspids of a dry human skull. The digital manipulation and the linear measurements were obtained with the Trophy Windows software (Throphy®). For each image, six different versions were created: 1) non-manipulated; 2) bright-contrast adjustment; 3) negative; 4) negative with brightness-contrast adjustment; 5) pseudo-colored; 6) pseudo-colored with brightness-contrast adjustment. In order to prevent interpretation bias because of the repetition of measurements, the examiners measured the radiographs in a random sequence. The two-way ANOVA test at 5% level of significance to compare the means of readings of the same operator with each filter indicated p<0.05 for the majority of operators, while the comparison between the mean values of operators using the same filter indicated p>0.05 for all filters. Based on the results, we concluded that linear measurements of interproximal alveolar bone loss on digital radiographs are highly reproducible among examiners. Nevertheless, the application of image filters significantly influenced the degree of intra-examiner reproducibility. Some filters even reduced the reproducibility of intra-examiner readings.
Resumo:
AIM: To assess the correlation between Wits and AF-BF appraisals with the ANB angle, and verify the influence of the facial type on these appraisals. METHODS: Lateral cephalometric radiographs from 118 untreated individuals were separated into 3 groups according to the facial pattern (brachyfacial, mesofacial, and dolichofacial). The radiographs were digitized and submitted to ANB angle and Wits and AF-BF appraisals on computer software. All radiographs were retraced for intraobserver and interobserver error tests. RESULTS: The Student's t test demonstrated no statistically significant differences on the intraobserver's test (P > .05). There were statistically significant differences in the readings of Wits values of the 3 groups and for AF-BF values in the brachyfacial and mesofacial groups (P <.05). The multiple linear regression tests demonstrated high correlation between ANB and AF-BF for the 3 groups (r2, 0.768). The same result was found for ANB and Wits (r2, 0.624). CONCLUSION: Facial pattern does not have an influence on the correlation between ANB and AF-BF nor between ANB and Wits, but it does influence the measurements of ANB, AF-BF, and Wits.
Resumo:
AIM: To investigate the relationship between divine proportion and facial esthetics in frontal photographs as well as whether any of the 4 ratios for manipulation provide more favorable facial esthetics. MATERIAL AND METHODS: The sample comprised 20 frontal photographs of Caucasian individuals (11 males and 9 females). The photographs were digitized and stored on a compact disk. A photometric analysis was created with 7 facial segments that were measured on Image Tool software and 4 ratios between 2 facial segments calculated using Microsoft Excel. This manipulation led to 5 different photographs of the same individual: one photograph with no manipulation and the others with 1 of the ratios manipulated in the Deformer 2.0 to very close or equal to 1.618. Thereafter, the 5 photographs of all individuals were evaluated by 12 examiners. The examiners selected those photographs that were esthetically more pleasant. CONCLUSION: After evaluation, a chi-square test revealed a relationship between divine proportion and facial esthetics. Among the ratios selected, R1 and R2 provided more favorable facial esthetics.
Resumo:
The aim of this research was to evaluate dental age in 102 patients with Down Syndrome, using panoramic radiographs. A software program developed by the Discipline of Radiology, School of Dentistry of São José dos Campos, São Paulo State University (UNESP), was used. A table of mineralization chronology of permanent teeth among Brazilians conceived by Nicodemo, Moraes and Medici Filho was used within the software. Statistical analysis of the results showed that 70.91% of the males land 61.21% of the females presented advanced dental age. Only 32.09% of the males and 39.79% of the females presented delayed dental age. Regarding the differences between the dental and chronological ages, two thirds of the males and females presented dental age with differences of up to 12 months, which means that they can be considered to be within normal standards, whereas only 18.87% of the males and 10.21% of the females presented dental age outside normal standards, with differences of over 24 months. In conclusion, the majority of the patients with Down Syndrome were considered to be within the normal standards of mineralization chronology.
Resumo:
The aim of this study was to assess the skeletal age of Brazilian individuals with Down syndrome (DS) using the method of Greulich and Pyle. Forty subjects with DS between the ages of 6 and 16 years were studied and compared to a control sample of children without DS. The statistical analysis showed that at the age of 7 years the skeletal age (SA) of the individuals with DS was delayed in relation to their chronological age (CA) (SA < CA). On the other hand, at the age of 15 years, their SA was advanced in relation to their CA (SA > CA). An evaluation of the results suggests that the period of adolescent development for individuals with DS was shorter. These individuals reach the completion of bone maturation earlier compared to individuals without DS. © 2008 Special Care Dentistry Association and Wiley Periodicals, Inc.
Resumo:
Since bovine teeth have been used as substitutes for human teeth in in vitro dental studies, the aim of this study was to compare the radiographic density of bovine teeth with that of human teeth to evaluate their usability for radiographic studies. Thirty bovine and twenty human teeth were cut transversally in 1 millimeter-thick slices. The slices were X-rayed using a digital radiographic system and an intraoral X-ray machine at 65 kVp and 7 mA. The exposure time (0.08 s) and the target-sensor distance (40 cm) were standardized for all the radiographs. The radiographic densities of the enamel, coronal dentin and radicular dentin of each slice were obtained separately using the histogram tool of Adobe Photoshop 7.0 software. The mean radiographic densities of the enamel, coronal dentin and radicular dentin were calculated by the arithmetic mean of the slices of each tooth. One-way ANOVA demonstrated statistically significant differences for the densities of bovine and human enamel (p < 0.05) and for bovine and human coronal dentin (p < 0.05). No statistically significant differences were found for the bovine and human radicular dentin (p > 0.05). Based on the results, the authors concluded that: a) the radiographic density of bovine enamel is significantly higher than that of human enamel; b) the radiodensity of bovine coronal dentin is statistically lower than the radiodensity of human coronal dentin; bovine radicular dentin is also less radiodense than human radicular dentin, although this difference was not statistically significant; c) bovine teeth should be used with care in radiographic in vitro studies.
Resumo:
In this report, we present a case of myositis ossificans traumatica (MOT) of the medial pterygoid muscle that had developed after mandibular block anesthesia administered for endodontic treatment of the lower right second molar, demonstrating typical features of this condition. MOT should be considered as a differential diagnosis when there is severe limitation of jaw opening and an associated trauma. Panoramic radiographs and axial and coronal computed tomography (CT) scans can effectively delineate the calcified mass. Other imaging studies that may be helpful include magnetic resonance imaging (MRI), bone scans, and ultrasound. As shown in our case, calcified masses were found in the right mandibular angle, which severely limited jaw opening. Some earlier reported cases of MOT were treated by extraoral surgical approaches with complete removal of the evolving muscle. The aim of this case report is to present only the diagnostic imaging aspects of myositis ossificans traumatica.
Elementos para elaboração de SIG no planejamento e gestão para expansão urbana em Álvares Machado-SP
Resumo:
Pós-graduação em Geografia - FCT
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)