954 resultados para Medical informatics applications


Relevância:

30.00% 30.00%

Publicador:

Resumo:

The synthesis of luminescent metal complexes is a very challenging task since they can be regarded as the starting point for a lot of different areas. Luminescent complexes, in fact, can be used for technological, industrial, medical and biological applications. During my PhD I worked with different metals having distinguishing intrinsic properties that make them different from each other and, in particular, more or less suitable for the different possible uses. Iridium complexes show the best photophysical properties: they have high quantum yields, very long lifetimes and possess easily tunable emissions throughout the visible range. On the other hand, Iridium is very expensive and scarcely available. The aim of my work concerning this metal was, therefore, to synthesize ligands able not only to form luminescent complexes, but also able to add functionalities to the final complex, increasing its properties, and therefore its possible practical uses. Since Re(I) derivatives have been reported to be suitable as probes in biological system, and the use of Re(I) reduces the costs, the synthesized bifunctional ligands containing a pyridine-triazole and a biotin unit were employed to obtain new Re(I) luminescent probes. Part of my work involved the design and synthesis of new ligands able to form stable complexes with Eu(III) and Ce(III) salts, in order to obtain an emission in the range of visible light: these two metals are quite cheap and relatively non-toxic compared to other heavy metals. Finally, I plan to synthesize organic derivatives that already possessed an emission thanks to the presence of other many chromophoric groups and can be able to link the Zinc (II), a low cost and especially non-toxic “green” metal. Zinc has not its own emission, but when it sticks to ligands, it increases their photophysical properties.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Rapid and sensitive detection of chemical and biological analytes becomes increasingly important in areas such as medical diagnostics, food control and environmental monitoring. Optical biosensors based on surface plasmon resonance (SPR) and optical waveguide spectroscopy have been extensively pushed forward in these fields. In this study, we combine SPR, surface plasmon-enhanced fluorescence spectroscopy (SPFS) and optical waveguide spectroscopy with hydrogel thin film for highly sensitive detection of molecular analytes.rnrnA novel biosensor based on SPFS which was advanced through the excitation of long range surface plasmons (LRSPs) is reported in this study. LRSPs are special surface plasmon waves propagating along thin metal films with orders of magnitude higher electromagnetic field intensity and lower damping than conventional SPs. Therefore, their excitation on the sensor surface provides further increased fluorescence signal. An inhibition immunoassay based on LRSP-enhanced fluorescence spectroscopy (LRSP-FS) was developed for the detection of aflatoxin M1 (AFM1) in milk. The biosensor allowed for the detection of AFM1 in milk at concentrations as low as 0.6 pg mL-1, which is about two orders of magnitude lower than the maximum AFM1 residue level in milk stipulated by the European Commission legislation.rnrnIn addition, LRSPs probe the medium adjacent to the metallic surface with more extended evanescent field than regular SPs. Therefore, three-dimensional binding matrices with up to micrometer thickness have been proposed for the immobilization of biomolecular recognition elements with large surface density that allows to exploit the whole evanescent field of LRSP. A photocrosslinkable carboxymethyl dextran (PCDM) hydrogel thin film is used as a binding matrix, and it is applied for the detection of free prostate specific antigen (f-PSA) based on the LRSP-FS and sandwich immunoassay. We show that this approach allows for the detection of f-PSA at low femto-molar range, which is approximately four orders of magnitude lower than that for direct detection of f-PSA based on the monitoring of binding-induced refractive index changes.rnrnHowever, a three dimensional hydrogel binding matrix with micrometer thickness can also serve as an optical waveguide. Based on the measurement of binding-induced refractive index changes, a hydrogel optical waveguide spectroscopy (HOWS) is reported for a label-free biosensor. This biosensor is implemented by using a SPR optical setup in which a carboxylated poly(N-isoproprylacrylamide) (PNIPAAm) hydrogel film is attached on a metallic surface and modified by protein catcher molecules. Compared to regular SPR biosensor with thiol self-assembled monolayer (SAM), HOWS provides an order of magnitude improved resolution in the refractive index measurements and enlarged binding capacity owing to its low damping and large swelling ratio, respectively. A model immunoassay experiment revealed that HOWS allowed detection of IgG molecules with a 10 pM limit of detection (LOD) that was five-fold lower than that achieved for SPR with thiol SAM. For the high capacity hydrogel matrix, the affinity binding was mass transport limited.rnrnThe mass transport of target molecules to the sensor surface can play as critical a role as the chemical reaction itself. In order to overcome the diffusion-limited mass transfer, magnetic iron oxide nanoparticles were employed. The magnetic nanoparticles (MNPs) can serve both as labels providing enhancement of the refractive index changes, and “vehicles” for rapidly delivering the analytes from sample solution to an SPR sensor surface with a gradient magnetic field. A model sandwich assay for the detection of β human chorionic gonadotropin (βhCG) has been utilized on a gold sensor surface with metallic diffraction grating structure supporting the excitation of SPs. Various detection formats including a) direct detection, b) sandwich assay, c) MNPs immunoassay without and d) with applied magnetic field were compared. The results show that the highly-sensitive MNPs immunoassay improves the LOD on the detection of βhCG by a factor of 5 orders of magnitude with respect to the direct detection.rn

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this work, the well-known MC code FLUKA was used to simulate the GE PETrace cyclotron (16.5 MeV) installed at “S. Orsola-Malpighi” University Hospital (Bologna, IT) and routinely used in the production of positron emitting radionuclides. Simulations yielded estimates of various quantities of interest, including: the effective dose distribution around the equipment; the effective number of neutron produced per incident proton and their spectral distribution; the activation of the structure of the cyclotron and the vault walls; the activation of the ambient air, in particular the production of 41Ar, the assessment of the saturation yield of radionuclides used in nuclear medicine. The simulations were validated against experimental measurements in terms of physical and transport parameters to be used at the energy range of interest in the medical field. The validated model was also extensively used in several practical applications uncluding the direct cyclotron production of non-standard radionuclides such as 99mTc, the production of medical radionuclides at TRIUMF (Vancouver, CA) TR13 cyclotron (13 MeV), the complete design of the new PET facility of “Sacro Cuore – Don Calabria” Hospital (Negrar, IT), including the ACSI TR19 (19 MeV) cyclotron, the dose field around the energy selection system (degrader) of a proton therapy cyclotron, the design of plug-doors for a new cyclotron facility, in which a 70 MeV cyclotron will be installed, and the partial decommissioning of a PET facility, including the replacement of a Scanditronix MC17 cyclotron with a new TR19 cyclotron.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This thesis work aims to find a procedure for isolating specific features of the current signal from a plasma focus for medical applications. The structure of the current signal inside a plasma focus is exclusive of this class of machines and a specific analysis procedure has to be developed. The hope is to find one or more features that shows a correlation with the dose erogated. The study of the correlation between the current discharge signal and the dose delivered by a plasma focus could be of some importance not only for the practical application of dose prediction but also for expanding the knowledge anbout the plasma focus physics. Vatious classes of time-frequency analysis tecniques are implemented in order to solve the problem.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The surgical treatment of liver tumours relies on precise localization of the lesions and detailed knowledge of the patient-specific vascular and biliary anatomy. Detailed three-dimensional (3D) anatomical information facilitates complete tumour removal while preserving a sufficient amount of functional liver tissue.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Diagnostics imaging is an essential component of patient selection and treatment planning in oral rehabilitation by means of osseointegrated implants. In 2002, the EAO produced and published guidelines on the use of diagnostic imaging in implant dentistry. Since that time, there have been significant developments in both the application of cone beam computed tomography as well as in the range of surgical and prosthetic applications that can potentially benefit from its use. However, medical exposure to ionizing radiation must always be justified and result in a net benefit to the patient. The as low a dose as is reasonably achievable principle must also be applied taking into account any alternative techniques that might achieve the same objectives. This paper reports on current EAO recommendations arising from a consensus meeting held at the Medical University of Warsaw (2011) to update these guidelines. Radiological considerations are detailed, including justification and optimization, with a special emphasis on the obligations that arise for those who prescribe or undertake such investigations. The paper pays special attention to clinical indications and radiographic diagnostic considerations as well as to future developments and trends.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The article summarizes the collective views expressed at the fourth session of the workshop Tissue Engineering-the Next Generation, which was devoted to the translation of results of tissue engineering research into applications. Ernst Hunziker described the paradigm of a dual translational approach, and argued that tissue engineering should be guided by the dimensions and physiological setting of the bodily compartment to be repaired. Myron Spector discussed collagen-glycosaminoglycan (GAG) scaffolds for musculoskeletal tissue engineering. Jeanette Libera focused on the biological and clinical aspects of cartilage tissue engineering, and described a completely autologous procedure for engineering cartilage using the patient's own chondrocytes and blood serum. Arthur Gertzman reviewed the applications of allograft tissues in orthopedic surgery, and outlined the potential of allograft tissues as models for biological and medical studies. Savio Woo discussed a list of functional tissue engineering approaches designed to restore the biochemical and biomechanical properties of injured ligaments and tendons to be closer to that of the normal tissues. Specific examples of using biological scaffolds that have chemoattractants as well as growth factors with unique contact guidance properties to improve their healing process were shown. Anthony Ratcliffe discussed the translation of the results of research into products that are profitable and meet regulatory requirements. Michael Lysaght challenged the proposition that commercial and clinical failures of early tissue engineering products demonstrate a need for more focus on basic research. Arthur Coury described the evolution of tissue engineering products based on the example of Genzyme, and how various definitions of success and failure can affect perceptions and policies relative to the status and advancement of the field of tissue engineering.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: Study of behavior and influence of a multileaf collimator (MLC) on dose calculation, verification, and portal energy spectra in the case of intensity-modulated fields obtained with a step-and-shoot or a dynamic technique. METHODS: The 80-leaf MLC for the Varian Clinac 2300 C/D was implemented in a previously developed Monte Carlo (MC) based multiple source model (MSM) for a 6 MV photon beam. Using this model and the MC program GEANT, dose distributions, energy fluence maps and energy spectra at different portal planes were calculated for three different MLC applications. RESULTS: The comparison of MC-calculated dose distributions in the phantom and portal plane, with those measured with films showed an agreement within 3% and 1.5 mm for all cases studied. The deviations mainly occur in the extremes of the intensity modulation. The MC method allows to investigate, among other aspects, dose components, energy fluence maps, tongue-and-groove effects and energy spectra at portal planes. CONCLUSION: The MSM together with the implementation of the MLC is appropriate for a number of investigations in intensity-modulated radiation therapy (IMRT).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Not all clinical trials are published, which may distort the evidence that is available in the literature. We studied the publication rate of a cohort of clinical trials and identified factors associated with publication and nonpublication of results. METHODS: We analysed the protocols of randomized clinical trials of drug interventions submitted to the research ethics committee of University Hospital (Inselspital) Bern, Switzerland from 1988 to 1998. We identified full articles published up to 2006 by searching the Cochrane CENTRAL database (issue 02/2006) and by contacting investigators. We analyzed factors associated with the publication of trials using descriptive statistics and logistic regression models. RESULTS: 451 study protocols and 375 corresponding articles were analyzed. 233 protocols resulted in at least one publication, a publication rate of 52%. A total of 366 (81%) trials were commercially funded, 47 (10%) had non-commercial funding. 346 trials (77%) were multi-centre studies and 272 of these (79%) were international collaborations. In the adjusted logistic regression model non-commercial funding (Odds Ratio [OR] 2.42, 95% CI 1.14-5.17), multi-centre status (OR 2.09, 95% CI 1.03-4.24), international collaboration (OR 1.87, 95% CI 0.99-3.55) and a sample size above the median of 236 participants (OR 2.04, 95% CI 1.23-3.39) were associated with full publication. CONCLUSIONS: In this cohort of applications to an ethics committee in Switzerland, only about half of clinical drug trials were published. Large multi-centre trials with non-commercial funding were more likely to be published than other trials, but most trials were funded by industry.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper describes the open source framework MARVIN for rapid application development in the field of biomedical and clinical research. MARVIN applications consist of modules that can be plugged together in order to provide the functionality required for a specific experimental scenario. Application modules work on a common patient database that is used to store and organize medical data as well as derived data. MARVIN provides a flexible input/output system with support for many file formats including DICOM, various 2D image formats and surface mesh data. Furthermore, it implements an advanced visualization system and interfaces to a wide range of 3D tracking hardware. Since it uses only highly portable libraries, MARVIN applications run on Unix/Linux, Mac OS X and Microsoft Windows.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Eine zunehmende Anzahl von Artikeln in Publikumszeitschriften und Journalen rückt die direkte Herstellung von Bauteilen und Figuren immer mehr in das Bewusstsein einer breiten Öffentlichkeit. Leider ergibt sich nur selten ein einigermaßen vollständiges Bild davon, wie und in welchen Lebensbereichen diese Techniken unseren Alltag verändern werden. Das liegt auch daran, dass die meisten Artikel sehr technisch geprägt sind und sich nur punktuell auf Beispiele stützen. Dieser Beitrag geht von den Bedürfnissen der Menschen aus, wie sie z.B. in der Maslow’schen Bedürfnispyramide strukturiert dargestellt sind und unterstreicht dadurch, dass 3D Printing (oder Additive Manufacturing resp. Rapid Prototyping) bereits alle Lebensbereiche erfasst hat und im Begriff ist, viele davon zu revolutionieren.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Mixed Reality (MR) aims to link virtual entities with the real world and has many applications such as military and medical domains [JBL+00, NFB07]. In many MR systems and more precisely in augmented scenes, one needs the application to render the virtual part accurately at the right time. To achieve this, such systems acquire data related to the real world from a set of sensors before rendering virtual entities. A suitable system architecture should minimize the delays to keep the overall system delay (also called end-to-end latency) within the requirements for real-time performance. In this context, we propose a compositional modeling framework for MR software architectures in order to specify, simulate and validate formally the time constraints of such systems. Our approach is first based on a functional decomposition of such systems into generic components. The obtained elements as well as their typical interactions give rise to generic representations in terms of timed automata. A whole system is then obtained as a composition of such defined components. To write specifications, a textual language named MIRELA (MIxed REality LAnguage) is proposed along with the corresponding compilation tools. The generated output contains timed automata in UPPAAL format for simulation and verification of time constraints. These automata may also be used to generate source code skeletons for an implementation on a MR platform. The approach is illustrated first on a small example. A realistic case study is also developed. It is modeled by several timed automata synchronizing through channels and including a large number of time constraints. Both systems have been simulated in UPPAAL and checked against the required behavioral properties.