966 resultados para MAO
Resumo:
The differential cross-sections for elastic scattering of F-17 and O-17 on Pb-208 have been measured at Radioactive Ion Beam Line at Lanzhou (RIBLL). The variation of the logarithms of differential cross-sections with the square of scattering angles, viz. angulax dispersion plot, shows clearly that there exists a turning point in the range of small scattering angles (6 degrees-20 degrees) for F-17 due to its exotic structure, while no turning point was observed for O-17. The experimental results have been compared with previous data of other groups. Systematical analysis on the available data seems to conclude that there is an exotic behavior of elastic scattering angular dispersion of weakly bound nuclei with halo or skin structure as compared with that of the stable nuclei. Therefore the fact that the turning point of the elastic scattering angular dispersion plot appears at small angle for weakly bound nuclei can be used as a new probe to investigate the halo and skin phenomenon.
Resumo:
The differential cross-sections for elastic scattering of F-17 and O-17 on Pb-208 have been measured at Radioactive Ion Beam Line at Lanzhou (RIBLL). The variation of the logarithms of differential cross-sections with the square of scattering angles shows clearly that there exists a turning point in the range of small scattering angles (6 degrees-20 degrees) for F-17 having exotic structure, while no turning point was observed in the O-17 elastic scattering. The experimental results have been compared with previous data. Systematical analysis on the available data seems to conclude that there is an exotic behavior of elastic scattering differential cross-sections of weakly bound nuclei with halo or skin structure as compared with that of the ordinary nuclei near stable line. Therefore the fact that the turning point of the logarithms of differential cross-sections appears at small angle for weakly bound nuclei could be used as a new probe to investigate the halo and skin phenomenon.
Resumo:
Based on several facts of CSRrn, such as the layout of the ring, the lattice parameters, exiting Schottky noise diagnosis equipment and fund, the primary stochastic cooling design of CSRm has been carried out. The optimum cooling time and the optimum cooling bandwidth axe obtained through simulation using the cooling function. The results indicate that the stochastic cooling is quite a powerful cooling method for CSRm. The comparison of the cooling effects of stochastic cooling and electron cooling in CSR are also presented. We can conclude that the combination of the two cooling methods on CSRrn will improve the beam cooling rate and quality beam greatly.
Resumo:
The differential cross sections of F-17 and O-17 elastic scattering products on Pb-208 have been measured at the Radioactive Ion Beam Line at Lanzhou (RIBLL). Two angular dispersion plots of ln(d sigma/d theta) versus theta 2 are obtained from the angular distribution of the elastic scattering differential cross sections. The angular dispersion plot exhibits a clear turning point for F-17 in the range of small scattering angles 6 degrees-20 degrees due to its exotic structure, but for O-17, the turning point is not observed in the same angular range. The experimental results have been compared with previous data of other groups. Systematical analysis on the available data supports the above conclusion that there is an exotic behaviour of the angular dispersion plot of weakly bound nuclei with halo or skin structure as compared with that of the ordinary nuclei near stable line. Therefore the turning point of the angular dispersion plot appears at small angle for weakly bound nuclei with halo or skin structure, and can be used as a new probe to investigate the halo and skin phenomena of weakly bound nuclei.
Resumo:
The principle of particle coupling between horizontal and vertical directions in solenoid is presented. Further more, the method of decoupling can be obtained by using the coupling dynamic equations. 5000 particles are tracked under three conditions: CSRm doesn't contain solenoids, contains main solenoid and toroids, contains compensating solenoids. The results of the particle trace calculations show that the particles coupling between horizontal and vertical is very serious because of the existence of solenoids, and lot's of particals are lost. Another two solenoids which locate in the fit place can be used to decrease the coupling intensation. The method is proved to be useful by the trace calculations.
Resumo:
Application of electron-cooling upgrades the quality of ion beams in the storage rings and brings new problems. The transverse magnetic field distorts the ion orbit while guiding the intense electron beam. The closed-orbit distortion should be and can be localized and controlled well inside the ring acceptance. This paper deals with the field in the e-cool section and concomitant COD of ion orbit and shows the correction scheme.
Resumo:
Electron beam longitudinal temperature is an important parameter on electron cooling devise. In this paper, electron beam longitudinal temperature on the HIRFL-CSR electron cooling devise is deduced from four important factors-flattened distribution, electrostatic accelerate, space charge effect and beam scattering.
Resumo:
The clinical trials of tumor therapy using heavy ions beam C-12 are now in progress at Institute of Modem Physics in Lanzhou. In order to achieve the precise radiotherapy with the high energy C-12 beam in active pencil beam scanning mode, we have developed an ionization chamber(IC) as an online monitor for beam intensity and also a dosimeter after calibration. Through the choosing of working gas and voltage, optimizing of the electrics and the read-out system, calibrating the linearity, the detector system provide us one of the simple and highly reliable way to monitoring the beam during the active pencil beam scanning treatments. The measurement results of this detector system show that it could work well under the condition of high energy C-12 beam in active pencil beam scanning mode.
Resumo:
With the commissioning of the Cooler Storage Ring at the Heavy Ion Research Facility in Lanzhou (HIRFL-CSR), a pilot experiment operating the CSRe in isochronous mode to test the power of HIRFL-CSR for measuring the mass of the short-lived nucleus was performed in December of 2007. The transition point gamma t of CSRe in isochronous mode is 1.395 which corresponds to the energy about 368 MeV/u for the ions with atomic number-to-charge ratio A/q = 2. The fragments with A/q = 2 of Ar-36 were injected into CSRe and their revolution frequencies were measured with a fast time pick-up detector with a thin foil in the circulating path of the ions. A mass resolution of better than 105 for m/Delta m was achieved.
Resumo:
The commissioning of the cooler storage rings (CSR) was successful, and the facility provides new possibilities for atomic physics with highly charged ions. Bare carbon, argon ions, were successfully stored in the main ring CSRm, cooled by cold electron beam, and accelerated up to 1 GeV/u. Heavier ions as Xe44+ and Kr28+ were also successfully stored in the CSRs. Both of the rings are equipped with new generation of electron coolers which can provide different electron beam density distributions. Electron-ion interactions, high precision X-ray spectroscopy, complete kinematical measurements for relativistic ion-atom collisions will be performed at CSRs. Laser cooling of heavy ions are planned as well. The physics programs and the present status will be summarized.
Resumo:
The status of the HIRFL (Heavy Ion Facility in Lanzhou) - Cooler Storage Ring (CSR) at the IMP is reported. The main physics goals at the HIRFL-CSR are the researches on nuclear structure and decay property, EOS of nuclear matter, hadron physics, highly charged atomic physics, high energy density physics, nuclear astrophysics, and applications for cancer therapy, space industries, materials and biology sciences. The HIRFL-CSR is the first ion cooler-storage-ring system in China, which consists of a main ring (CSRm), an experimental ring (CSRe) and a radioactive beamline (RIBLL2). The two existing cyclotrons SFC (K=70) and SSC (K=450) are used as its injectors. The 7MeV/u12C6+ ions were stored successfully in CSRm with the stripping injection in January 2006. After that, realized were the accelerations of C-12(6+), Ar-36(18+), Kr-78(28+) and Xe-129(27+) ions with energies of 1GeV/u, 1GeV/u, 450 MeV/u and 235 MeV/u, respectively, including accumulation, electron cooling and acceleration. In 2008, the first two isochronous mass measurement experiments with the primary beams of Ar-36(18+) and Kr-78(28+) were performed at CSRe with the Delta p/p similar to 10(-5).
Resumo:
Charge stripping is employed to produce multi-charged ions for injecting the cooling storage ring After penetrating through the carbon foil, the widened distribution of ion charge states poses a limit to the ion injection Therefore, the carbon foil plays a key role in the charge snipping injection In this paper, foul strippers for Heavy Ion Research Facility at Lanzhou (HIRFL) and Cooling Sun age Ring (CSR) are introduced The charge state distribution of the stripped ions is measured and the stripping efficiency of the foils is investigated The experimental results are consistent with the theoretical values
Resumo:
A study of cooled Au-197 projectile-fragmentation products has been performed with a storage ring. This has enabled metastable nuclear excitations with energies up to 3 MeV, and half-lives extending to minutes or longer, to be identified in the neutron-rich nuclides Hf-183,Hf-184,Hf-186 and Ta-186,Ta-187. The results support the prediction of a strongly favored isomer region near neutron number 116.
Resumo:
A high performance Time-of-Flight detector has been designed and constructed for isochronous mass spectrometry at the experimental Cooler Storage Ring (CSRe) The detector has been successfully used in an experiment to measure the masses of the N approximate to Z approximate to 33 nuclides near the proton drip-line Of particular interest is the mass of As-65 A maximum detection efficiency of 70% and a time resolution of 118 +/- 8 Ps (FWHM) have been achieved in the experiment The dependence of detection efficiency and signal average pulse height (APH) on atomic number Z has been studied The potential of APH for Z identification has been discussed (C) 2010 Elsevier B V All rights reserved
Resumo:
The 400 MeV/u C-12(6+) ion beam was successfully cooled by the intensive electron beam near 1 A in CSRe. The momentum cooling time was estimated near 15 s. The cooling force was measured in the cases of different electron beam profiles, and the different angles between the ion beam and electron beam. The lifetime of the ion beam in CSRe was over 80 h. The dispersion in the cooling section was confirmed as positive close to zero. The beam sizes before cooling and after cooling were measured by the moving screen. The beam diameter after cooling was about 1 mm. The bunch length was measured with the help of the signals from the beam position monitor. The diffusion was studied in the absence of the electron beam.