765 resultados para Liquid-equilibria
Resumo:
BACKGROUND: Fine-needle aspiration cytology (FNAC) of serous membrane effusions may fulfil a challenging role in the diagnostic analysis of both primary and metastatic disease. From this perspective, liquid-based cytology (LBC) represents a feasible and reliable method for empowering the performance of ancillary techniques (ie, immunocytochemistry and molecular testing) with high diagnostic accuracy. METHODS: In total, 3171 LBC pleural and pericardic effusions were appraised between January 2000 and December 2013. They were classified as negative for malignancy (NM), suspicious for malignancy (SM), or positive for malignancy (PM). RESULTS: The cytologic diagnoses included 2721 NM effusions (2505 pleural and 216 pericardic), 104 SM effusions (93 pleural and 11 pericardic), and 346 PM effusions (321 pleural and 25 pericardic). The malignant pleural series included 76 unknown malignancies (36 SM and 40 PM effusions), 174 metastatic lesions (85 SM and 89 PM effusions), 14 lymphomas (3 SM and 11 PM effusions), 16 mesotheliomas (5 SM and 11 SM effusions), and 3 myelomas (all SM effusions). The malignant pericardic category included 20 unknown malignancies (5 SM and 15 PM effusions), 15 metastatic lesions (1 SM and 14 PM effusions), and 1 lymphoma (1 PM effusion). There were 411 conclusive immunocytochemical analyses and 47 molecular analyses, and the authors documented 88% sensitivity, 100% specificity, 98% diagnostic accuracy, 98% negative predictive value, and 100% positive predictive value for FNAC. CONCLUSIONS: FNAC represents a primary diagnostic tool for effusions and a reliable approach with which to determine the correct follow-up. Furthermore, LBC is useful for ancillary techniques, such as immunocytochemistry and molecular analysis, with feasible diagnostic and predictive utility.
Resumo:
The sol-gel method was employed in the synthesis of di-urethane cross-linked poly( caprolactone) (PCL(530)/siloxane biohybrid ormolytes incorporating either a mixture of lithium triflate (LiCF3SO3) and the ionic liquid (IL) 1-ethyl-3-methyl imidazolium tetrafluoroborate ([Emim]BF4), or solely with [Emim]BF4 or LiCF3SO3. The ormolyte doped with [Emim]BF4 is thermally more stable and exhibits higher ionic conductivity (4 x 10-4 and 2 x 10-3 S cm-1 at 36 and 98 ºC, respectively) than those containing the LiCF3SO3/[Emim]BF4 mixture or just LiCF3SO3. The three ormolytes were employed in the production of glass/ITO/ormolyte/WO3/ITO/glass electrochromic devices (ECDs) designated as ECD@Y with Y = Li-[Emim]BF4, [Emim]BF4 and Li. The three ECDs displayed fast switching speed (ca. 30 s). ECD@Li-[Emim]BF4 exhibited an electrochromic contrast of 18.4 % and an optical density change of 0.11 in the visible region, the coloration efficiency attained at 555 nm was 159 and 80.2 cm-2 C-1 in the “on” and “off” states, respectively, and the open circuit memory was 48 hours. In the “on” state the CIE 1931 color space coordinates were x = 0.29 and y = 0.30, corresponding to blue color.
Resumo:
New polymer electrolytes (PEs) based on chitosan and three ionic liquid (IL) families ([C2mim][CnSO3], [C2mim][CnSO4] and [C2mim][diCnPO4]) were synthesized by the solvent casting method. The effect of the length of the alkyl chain of the IL anion on the thermal, morphological and electrochemical properties of the PEs was studied. The solid polymer electrolytes (SPE) membranes were analyzed by differential scanning calorimetry (DSC), thermogravimetric analysis (TGA), X-ray diffraction (XRD), scanning electron microscopy (SEM), energy dispersive X-ray (EDX), polarized optical microscopy (POM), atomic force microscopy (AFM), complex impedance spectroscopy (ionic conductivity) and cyclic voltammetry (CV). The obtained results evidenced an influence of the alkyl chain length of the IL anion on the temperature of degradation, birefringence, surface roughness and ionic conductivity of the membranes. The DSC, XRD and CV results showed independency from the length of the IL-anion-alkyl chain. The PEs displayed an predominantly amorphous morphology, a minimum temperature of degradation of 135 °C, a room temperature (T = 25 °C) ionic conductivity of 7.78 × 10−4 S cm−1 and a wide electrochemical window of ∼ 4.0 V.
Resumo:
Biopolymer-based materials have been of particular interest and they are alternatives to synthetic polymers based on the decreasing oil resources. The polymer electrolytes were doped with choline-based IL N,N,Ntrimethyl- N-(2-hydroxyethyl)ammonium bis(trifluoromethylsulfonyl)imide ([N1 1 1 2(OH)][NTf2]), or Er (CF3SO3)3 or both. The polymer electrolytes were employed in the production of glass/ITO/WO3/electrolyte/ CeO2–TiO2/ITO/glass electrochromic devices (ECDs). The lowest onset temperature for the degradation of all the SPEs is at ~130 °C for the Gellan Er (CF3SO3)3 (10:1) this temperature range of stability is wide enough for a material to be applied as an electrolyte/separator component in electrochemical devices. The three ECDs displayed fast switching speed (ca. 15 s). Gellan [N1 1 1 2(OH)][NTf2] Er (CF3SO3)3 (5:1:10) exhibited an electrochromic contrast of 4.2% in the visible region, the coloration efficiency attained at 555 nm was 3.5 and 0.90 cm-2 C-1 in the “colored” and “bleached” states, respectively, and the open circuit memorywas 48 h. Preliminary tests performed with a prototype electrochromic device (ECD) incorporating WO3 as cathodic electrochromic layer, are extremely encouraging.
Resumo:
OBJECTIVE The aim of this study was to compare the performance of the current conventional Pap smear with liquid-based cytology (LBC) preparations. STUDY DESIGN Women routinely undergoing their cytopathological and histopathological examinations at Fundação Oncocentro de São Paulo (FOSP) were recruited for LBC. Conventional smears were analyzed from women from other areas of the State of São Paulo with similar sociodemographic characteristics. RESULTS A total of 218,594 cases were analyzed, consisting of 206,999 conventional smears and 11,595 LBC. Among the conventional smears, 3.0% were of unsatisfactory preparation; conversely, unsatisfactory LBC preparations accounted for 0.3%. The ASC-H (atypical squamous cells - cannot exclude high-grade squamous intraepithelial lesion) frequency did not demonstrate any differences between the two methods. In contrast, the incidence of ASC-US (atypical squamous cells of undetermined significance) was almost twice as frequent between LBC and conventional smears, at 2.9 versus 1.6%, respectively. An equal percentage of high-grade squamous intraepithelial lesions were observed for the two methods, but not for low-grade squamous intraepithelial lesions, which were more significantly observed in LBC preparations than in conventional smears (2.2 vs. 0.7%). The index of positivity was importantly enhanced from 3.0% (conventional smears) to 5.7% (LBC). CONCLUSIONS LBC performed better than conventional smears, and we are truly confident that LBC can improve public health strategies aimed at reducing cervical lesions through prevention programs.
Resumo:
Here, we evaluate the diagnostic and prognostic role of liquid-based cytology (LBC) in different body lesions, including thyroid, lung, effusions and malignant breast lesions. LBC has gained consensus after being applied to both non-gynecologic and fine-needle aspiration cytology. Although some remain sceptical regarding the diagnostic efficacy of LBC, mainly when used alone, in recent years, good results have been obtained as long as it showed a high diagnostic accuracy. Here, we discuss the additional possibility of storing material for the application of ancillary techniques (immunocytochemistry–molecular analysis) with several diagnostic and prognostic advantages, which may pave the way for the challenging evaluation of both monitoring responses to treatment and resistance to targeted therapies in thyroid, lung, breast carcinoma or malignant effusions. Furthermore, it provides the use of several molecular spots as specific targets for personalized therapy.
Resumo:
Background: In pathological situations, such as acute myocardial infarction, disorders of motility of the proximal gut can trigger symptoms like nausea and vomiting. Acute myocardial infarction delays gastric emptying (GE) of liquid in rats. Objective: Investigate the involvement of the vagus nerve, α 1-adrenoceptors, central nervous system GABAB receptors and also participation of paraventricular nucleus (PVN) of the hypothalamus in GE and gastric compliance (GC) in infarcted rats. Methods: Wistar rats, N = 8-15 in each group, were divided as INF group and sham (SH) group and subdivided. The infarction was performed through ligation of the left anterior descending coronary artery. GC was estimated with pressure-volume curves. Vagotomy was performed by sectioning the dorsal and ventral branches. To verify the action of GABAB receptors, baclofen was injected via icv (intracerebroventricular). Intravenous prazosin was used to produce chemical sympathectomy. The lesion in the PVN of the hypothalamus was performed using a 1mA/10s electrical current and GE was determined by measuring the percentage of gastric retention (% GR) of a saline meal. Results: No significant differences were observed regarding GC between groups; vagotomy significantly reduced % GR in INF group; icv treatment with baclofen significantly reduced %GR. GABAB receptors were not conclusively involved in delaying GE; intravenous treatment with prazosin significantly reduced GR% in INF group. PVN lesion abolished the effect of myocardial infarction on GE. Conclusion: Gastric emptying of liquids induced through acute myocardial infarction in rats showed the involvement of the vagus nerve, alpha1- adrenergic receptors and PVN.
Resumo:
Magdeburg, Univ., Fak. für Naturwiss., Diss., 2010
Resumo:
Magdeburg, Univ., Fak. für Mathematik, Diss., 2013
Resumo:
Magdeburg, Univ., Fak. für Mathematik, Diss., 2014
Resumo:
Magdeburg, Univ., Fak. für Verfahrens- und Systemtechnik, Diss., 2014
Resumo:
Consider a Riemannian manifold equipped with an infinitesimal isometry. For this setup, a unified treatment is provided, solely in the language of Riemannian geometry, of techniques in reduction, linearization, and stability of relative equilibria. In particular, for mechanical control systems, an explicit characterization is given for the manner in which reduction by an infinitesimal isometry, and linearization along a controlled trajectory "commute." As part of the development, relationships are derived between the Jacobi equation of geodesic variation and concepts from reduction theory, such as the curvature of the mechanical connection and the effective potential. As an application of our techniques, fiber and base stability of relative equilibria are studied. The paper also serves as a tutorial of Riemannian geometric methods applicable in the intersection of mechanics and control theory.
Resumo:
The aplicability of Fava's Netto medium in the liquid nitrogen cryopreservation technique of Paracoccidioides brasiliensis cells was demonstrated.
Resumo:
We analyze (non-deterministic) contests with anonymous contest success functions. There is no restriction on the number of contestants or on their valuations for the prize. We provide intuitive and easily verifiable conditions for the existence of an equilibrium with properties similar to the one of the (deterministic) all-pay auction. Since these conditions are fulfilled for a wide array of situations, the predictions of this equilibrium are very robust to the specific details of the contest. An application of this result contributes to fill a gap in the analysis of the popular Tullock rent- seeking game because it characterizes properties of an equilibrium for increasing returns to scale larger than two, for any number of contestants and in contests with or without a common value. Keywords: (non-) deterministic contest, all-pay auction, contest success functions. JEL Classification Numbers: C72 (Noncooperative Games), D72 (Economic Models of Political Processes: Rent-Seeking, Elections), D44 (Auctions).
Resumo:
Captan and folpet are fungicides largely used in agriculture. They have similar chemical structures, except that folpet has an aromatic ring unlike captan. Their half-lives in blood are very short, given that they are readily broken down to tetrahydrophthalimide (THPI) and phthalimide (PI), respectively. Few authors measured these biomarkers in plasma or urine, and analysis was conducted either by gas chromatography coupled to mass spectrometry or liquid chromatography with UV detection. The objective of this study was thus to develop simple, sensitive and specific liquid chromatography-atmospheric pressure chemical ionization-tandem mass spectrometry (LC/APCI-MS/MS) methods to quantify both THPI and PI in human plasma and urine. Briefly, deuterated THPI was added as an internal standard and purification was performed by solid-phase extraction followed by LC/APCI-MS/MS analysis in negative ion mode for both compounds. Validation of the methods was conducted using spiked blank plasma and urine samples at concentrations ranging from 1 to 250 μg/L and 1 to 50 μg/L, respectively, along with samples of volunteers and workers exposed to captan or folpet. The methods showed a good linearity (R (2) > 0.99), recovery (on average 90% for THPI and 75% for PI), intra- and inter-day precision (RSD, <15%) and accuracy (<20%), and stability. The limit of detection was 0.58 μg/L in urine and 1.47 μg/L in plasma for THPI and 1.14 and 2.17 μg/L, respectively, for PI. The described methods proved to be accurate and suitable to determine the toxicokinetics of both metabolites in human plasma and urine.