884 resultados para Laser refractive surgery


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Aim: The aim of this study was to compare the microtensile bond strength of three adhesive systems, using different methods of dentin preparation. Materials and methods: A hundred and eight bovine teeth were used. The dentin from buccal face was exposed and prepared with three different methods, divided in 3 groups: Group 1 (DT)- diamond tip on a high-speed handpiece; Group 2 (CVD)-CVD tip on a ultrasonic handpiece; Group 3 (LA)-Er: YAG laser. The teeth were divided into 3 subgroups, according adhesive systems used: Subgroup 1-Adper Single Bond Plus/3M ESPE (SB) total-etch adhesive; Subgroup 2-Adper Scotchbond SE/3M ESPE (AS) selfetching adhesive; Subgroup 3-Clearfil SE Bond/Kuraray (CS) selfetching adhesive. Blocks of composite (Filtek Z250-3M ESPE) 4 mm high were built up and specimens were stored in deionized water for 24 hours at 37°C. Serial mesiodistal and buccolingual cuts were made and stick-like specimens were obtained, with transversal section of 1.0 mm2. The samples were submitted to microtensile test at 1 mm/min and load of 10 kg in a universal testing machine. Data (MPa) were subjected to ANOVA and Tukey's tests (p < 0.05). Results and conclusion: Surface treatment with Diamond or CVD tips associated with Clearfil SE Bond adhesive produced significantly lower bond strength values compared to other groups. Surface treatment with Er: YAG laser associated with Single Bond Plus or Clearfil SE Bond adhesives and surface treatment with CVD tip associated with Adper Scotchbond SE adhesive produced significantly lower bond strength values compared to surface treatment with diamond or CVD tips associated with Single Bond Plus or Adper Scotchbond SE adhesives. Clinical significance: Interactions between laser and the CVD tip technologies and the different adhesive systems can produce a satisfactory bonding strength result, so that these associations may be beneficial and enhance the clinical outcomes.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Low-level laser therapy (LLLT) has been used for the treatment of dentinal hypersensitivity. However, the specific LLL dose and the response mechanisms of these cells to transdentinal irradiation have not yet been demonstrated. Therefore, this study evaluated the transdentinal effects of different LLL doses on stressed odontoblast-like pulp cells MDPC-23 seeded onto the pulpal side of dentin discs obtained from human third molars. The discs were placed in devices simulating in vitro pulp chambers and the whole set was placed in 24-well plates containing plain culture medium (DMEM). After 24 h incubation, the culture medium was replaced by fresh DMEM supplemented with either 5% (simulating a nutritional stress condition) or 10% fetal bovine serum (FBS). The cells were irradiated with doses of 15 and 25 J cm-2 every 24 h, totaling three applications over three consecutive days. The cells in the control groups were removed from the incubator for the same times as used in their respective experimental groups for irradiation, though without activating the laser source (sham irradiation). After 72 h of the last active or sham irradiation, the cells were evaluated with respect to succinic dehydrogenase (SDH) enzyme production (MTT assay), total protein (TP) expression, alkaline phosphatase (ALP) synthesis, reverse transcriptase polymerase chain reaction (RT-PCR) for collagen type 1 (Col-I) and ALP, and morphology (SEM). For both tests, significantly higher values were obtained for the 25 J cm-2 dose. Regarding SDH production, supplementation of the culture medium with 5% FBS provided better results. For TP and ALP expression, the 25 J cm-2 presented higher values, especially for the 5% FBS concentration (Mann-Whitney p < 0.05). Under the tested conditions, near infrared laser irradiation at 25 J cm -2 caused transdentinal biostimulation of odontoblast-like MDPC-23 cells. © 2013 Astro Ltd.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

It is known that low level laser therapy is able to improve skin flap viability by increasing angiogenesis. However, the mechanism for new blood vessel formation is not completely understood. Here, we investigated the effects of 660 nm and 780 nm lasers at fluences of 30 and 40 J/cm2 on three important mediators activated during angiogenesis. Sixty male Wistar rats were used and randomly divided into five groups with twelve animals each. Groups were distributed as follows: skin flap surgery non-irradiated group as a control; skin flap surgery irradiated with 660 nm laser at a fluence of 30 or 40 J/cm2 and skin flap surgery irradiated with 780 nm laser at a fluence of 30 or 40 J/cm2. The random skin flap was performed measuring 10 × 4 cm, with a plastic sheet interposed between the flap and the donor site. Laser irradiation was performed on 24 points covering the flap and surrounding skin immediately after the surgery and for 7 consecutive days thereafter. Tissues were collected, and the number of vessels, angiogenesis markers (vascular endothelial growth factor, VEGF and hypoxia inducible factor, HIF-1α) and a tissue remodeling marker (matrix metalloproteinase, MMP-2) were analyzed. LLLT increased an angiogenesis, HIF-1α and VEGF expression and decrease MMP-2 activity. These phenomena were dependent on the fluences, and wavelengths used. In this study we showed that LLLT may improve the healing of skin flaps by enhancing the amount of new vessels formed in the tissue. Both 660 nm and 780 nm lasers were able to modulate VEGF secretion, MMP-2 activity and HIF-1α expression in a dose dependent manner. © 2013 Published by Elsevier B.V.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Pós-graduação em Odontologia - FOA

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Pós-graduação em Ginecologia, Obstetrícia e Mastologia - FMB

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The proposal of this study was to compare a wound healing between conventional suture and vaporization with CO2 laser in rats skin. ln such case 24 rats were utilized, making two longitudinal incisions in dorsum by scalpel. ln the left side incision the wound was sutured with nylon thread. ln the right side incision the wound were close by approach and vaporized with C02 laser, defocusing, 8 watts in continuous mode. The wound healing was followed by clinical photographic taking at the times: immediately after the procedure, 24 hours, 3, 7, 14, and 21 days. The results showed an early delay of reparation in healing vaporized in comparison with the sutured one, however occurred 21 days both repair tissue showed the same clinical characteristic. This results suggested that the C02 laser can be used by eventual substitute of suture.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: This study aims to investigate the effects of low-level laser therapy (LLLT) on biceps brachi muscular fatigue in 20 young females. Background data: Exhausting physical activity leads to muscular fatigue, which could decrease muscular strength, and may cause impairment in motor control and muscle pain. Several biochemical and biophysical resources have been studied in an attempt to accelerate the recovery of muscle fatigue. Among these, LLLT is emphasized. Methods: Twenty subjects were randomized in one laser group and one placebo group in two sessions of a crossover design experimental procedure; the second session taking place within 7 days of the first. In the first session, subjects underwent a collection of surface electromyographic (SEMG) data of the biceps brachii muscle, followed by active or placebo LLLT at the same muscle, followed then by another EMG sample of biceps brachii. Blood samples were collected five times during the experimental procedure. Second session procedures were identical to the first, with exception of LLLT, which was the opposite of the first session. The fatigue protocol consisted of 60sec of elbow flexion-extension movement performed with 75% of one maximum repetition. Blood lactate, EMG fatigue, and the number of elbow flexion-extension repetitions during the fatigue protocol were used to evaluate the effects of laser therapy (808nm wavelength, 100mW output power, power density of 35.7 W/cm(2), 70sec each point and 7J/point on eight points). Results: No statistical differences were found for eletromyographic fatigue and blood lactate values between groups. Mean numbers of elbow flexion-extension repetitions were 22.6 +/- 7.58 after placebo, and 25.1 +/- 9.89 after active LLLT group, but these differences were not statistically significant (p=0.342). Conclusions: LLLT had limited effects on delaying muscle fatigue in a young female sample, although a tendency was observed in the active laser group toward showing lower electromyography fatigue of biceps brachii muscle. No intergroup differences were found in the number of muscle contractions and lactate concentration.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)