922 resultados para KNEE OSTEOARTHRITIS


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction The importance of the micromovements in the mechanism of aseptic loosening is clinically difficult to evaluate. To complete the analysis of a series of total knee arthroplasties (TKA), we used a tridimensional numerical model to study the micromovements of the tibial implant.Material and Methods Fifty one patients (with 57 cemented Porous Coated Anatomic TKAs) were reviewed (mean follow-up 4.5 year). Radiolucency at the tibial bone-cement interface was sought on the AP radiographs and divided in 7 areas. The distribution of the radiolucency was then correlated with the axis of the lower limb as measured on the orthoradiograms.The tridimensional numerical model is based on the finite element method. It allowed the measurement of the cemented prosthetic tibial implant's displacements and the microvements generated at bone-ciment interface. A total load (2000 Newton) was applied at first vertically and asymetrically on the tibial plateau, thereby simulating an axial deviation of the lower limbs. The vector's posterior inclination then permitted the addition of a tangential component to the axial load. This type of effort is generated by complex biomechanical phenomena such as knee flexion.Results 81 per cent of the 57 knees had a radiolucent line of at least 1 mm, at one or more of the tibial cement-epiphysis jonctional areas. The distribution of these lucent lines showed that they came out more frequently at the periphery of the implant. The lucent lines appeared most often under the unloaded margin of the tibial plateau, when axial deviation of lower limbs was present.Numerical simulations showed that asymetrical loading on the tibial plateau induced a subsidence of the loaded margin (0-100 microns) and lifting off at the opposite border (0-70 microns). The postero-anterior tangential component induced an anterior displacement of the tibial implant (160-220 microns), and horizontal micromovements with non homogenous distribution at the bone-ciment interface (28-54 microns).Discussion Comparison of clinical and numerical results showed a relation between the development of radiolucent lines and the unloading of the tibial implant's margin. The deleterious effect of lower limbs' axial deviation is thereby proven. The irregular distribution of lucent lines under the tibial plateau was similar of the micromovements' repartition at the bone-cement interface when tangential forces were present. A causative relation between the two phenomenaes could not however be established.Numerical simulation is a truly useful method of study; it permits to calculate micromovements which are relative, non homogenous and of very low amplitude. However, comparative clinical studies remain as essential to ensure the credibility of results.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: Performing total knee replacement, accurate alignment and neutral rotation of the femoral component are widely believed to be crucial for the ultimate success. Contrary to absolute bone referenced alignment, using a ligament balancing technique does not automatically rotate the femoral component parallel to the transepicondylar axis. In this context we established the hypothesis that rotational alignment of the femoral component parallel to the transepicondylar axis (0° ± 3°) results in better outcome than alignment outside of this range. METHODS: We analysed 204 primary cemented mobile bearing total knee replacements five years postoperatively. Femoral component rotation was measured on axial radiographs using the condylar twist angle (CTA). Knee society score, range of motion as well as subjective rating documented outcome. RESULTS: In 96 knees the femoral component rotation was within the range 0 ± 3° (neutral rotation group), and in 108 knees the five-year postoperative rotational alignment of the femoral component was outside of this range (outlier group). Postoperative CTA showed a mean of 2.8° (±3.4°) internal rotation (IR) with a range between 6° external rotation (ER) and 15° IR (CI 95). No difference with regard to subjective and objective outcome could be detected. CONCLUSION: The present work shows that there is a large given natural variability in optimal rotational orientation, in this study between 6° ER and 15° IR, with numerous co-factors determining correct positioning of the femoral component. Further studies substantiating pre- and postoperative determinants are required to complete the understanding of resulting biomechanics in primary TKA.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: Enchondromas are among the most current benign bone tumours. Malignant degeneration is extremely rare (<1%) and generally presents as a low grade chondrosarcoma. For localized grade 1 lesions, the treatment of choice is curettage. Wide excision and reconstruction is generally not necessary, unless locally advanced or more aggressive behaviour is suspected at presentation. Case report: A healthy 72 yo male presented with pain and recurrent knee joint effusion. X-rays show a classical central distal metaphyseal enchondroma of the femur associated with subtle osteolysis of the lateral condyle. MRI confirms the presence of a locally aggressive chondromatous lesion based in a classical enchondroma. Core needle biopsy revealed a grade 1 chondrosarcoma, which was in contrast to the radiological aggressiveness of the lesion. Total body CT-scan did not reveal metastatic disease. A wide resection was planned, as a high-grade lesion and joint contamination was suspected. We performed an extra-articular knee resection and reconstruction with a hinged modular total knee megaprosthesis. The definitive histology was grade 1 chondrosarcoma, the surgical margins were wide. The evolution was favourable and the patient was able to perform all his activities of daily living independently without pain at 6 weeks postop. Knee flexion reached 90°. The oncologic screening at 18 months did not show local or distant recurrence. Conclusion: Joints near a benign tumour that suddenly become symptomatic or present an effusion might indicate a malignant transformation. Wide resection and prosthetic reconstruction remains an effective treatment option even in low grade cartilaginous lesions if (1) the adjacent joint is contaminated, or (2) joint-sparing surgery would result in a severe functional impairment of the limb.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Multiple epiphyseal dysplasia (MED) is one of the more common generalised skeletal dysplasias. Due to its clinical heterogeneity diagnosis may be difficult. Mutations of at least six separate genes can cause MED. Joint deformities, joint pain and gait disorders are common symptoms. CASE PRESENTATION: We report on a 27-year-old male patient suffering from clinical symptoms of autosomal recessive MED with habitual dislocation of a multilayered patella on both sides, on the surgical treatment and on short-term clinical outcome. Clinical findings were: bilateral hip and knee pain, instability of femorotibial and patellofemoral joints with habitual patella dislocation on both sides, contractures of hip, elbow and second metacarpophalangeal joints. Main radiographic findings were: bilateral dislocated multilayered patella, dysplastic medial tibial plateaus, deformity of both femoral heads and osteoarthritis of the hip joints, and deformity of both radial heads. In the molecular genetic analysis, the DTDST mutation g.1984T > A (p.C653S) was found at the homozygote state. Carrier status was confirmed in the DNA of the patient's parents. The mutation could be considered to be the reason for the patient's disease. Surgical treatment of habitual patella dislocation with medialisation of the tibial tuberosity led to an excellent clinical outcome. CONCLUSIONS: The knowledge of different phenotypes of skeletal dysplasias helps to select genes for genetic analysis. Compared to other DTDST mutations, this is a rather mild phenotype. Molecular diagnosis is important for genetic counselling and for an accurate prognosis. Even in case of a multilayered patella in MED, habitual patella dislocation could be managed successfully by medialisation of the tibial tuberosity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The usual complications of total knee arthroplasty include thrombo-embolism, infection, and loosening. We report an unusual and potentially serious complication of an intramedullary guide lodging within the femoral canal during the procedure. Considering the risk of fracture and additional exposure, the guide was not removed and was cut in situ. The rest of the operation was completed successfully and the patient made an uneventfully recovery.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Anatomical total shoulder arthroplasty (TSA) for glenohumeral osteoarthritis (OA) and severe posterior glenoid wear may entail early postoperative complications (recurrence of posterior subluxation, glenoid loosening). To avoid these mechanical problems, reverse shoulder arthroplasty (RSA) has recently been proposed, mainly for its intrinsic stability. Our purpose was to present the results of TSA and RSA in glenohumeral OA with posterior glenoid wear of at least 20°. HYPOTHESIS: By virtue of its constrained design, RSA could prevent recurrence of posterior subluxation and limit the occurrence of mechanical complications. MATERIALS AND METHODS: A consecutive series of 23 patients (27 shoulders) were treated for glenohumeral OA with total shoulder prostheses: 19 TSAs and 8 RSAs. Mean age was 70years (range, 47-85years), mean retroversion angle 28° (20°-50°) and mean subluxation index 74% (57-89%). Constant Score, Subjective Shoulder Value (SSV), QuickDASH and Simple Shoulder Test (SST) were measured, and radiological examinations were performed at a mean follow-up of 52months (24-95months). RESULTS: TSA and RSA patients respectively displayed Constant Scores of 65 and 65, SSV of 79% and 74%, QuickDASH of 16 and 27, and SST of 88 and 78. Two patients underwent surgical revision of TSA because of glenoid loosening; 52% of TSA patients presented complete radiolucent lines and 11% recurrence of posterior subluxation. CONCLUSION: Complications are frequently observed after shoulder arthroplasty for OA with severe glenoid retroversion. RSA could be an alternative to TSA for selected patients, independently of rotator cuff status. Studies on RSA in this specific indication with longer follow-up are now needed. LEVEL OF EVIDENCE: Level IV; retrospective case series.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

CONTEXT: Symptomatic venous thromboembolism (VTE) after total or partial knee arthroplasty (TPKA) and after total or partial hip arthroplasty (TPHA) are proposed patient safety indicators, but its incidence prior to discharge is not defined. OBJECTIVE: To establish a literature-based estimate of symptomatic VTE event rates prior to hospital discharge in patients undergoing TPHA or TPKA. DATA SOURCES: Search of MEDLINE, EMBASE, and the Cochrane Library (1996 to 2011), supplemented by relevant articles. STUDY SELECTION: Reports of incidence of symptomatic postoperative pulmonary embolism or deep vein thrombosis (DVT) before hospital discharge in patients who received VTE prophylaxis with either a low-molecular-weight heparin or a subcutaneous factor Xa inhibitor or oral direct inhibitor of factors Xa or IIa. DATA EXTRACTION AND SYNTHESIS: Meta-analysis of randomized clinical trials and observational studies that reported rates of postoperative symptomatic VTE in patients who received recommended VTE prophylaxis after undergoing TPHA or TPKA. Data were independently extracted by 2 analysts, and pooled incidence rates of VTE, DVT, and pulmonary embolism were estimated using random-effects models. RESULTS: The analysis included 44,844 cases provided by 47 studies. The pooled rates of symptomatic postoperative VTE before hospital discharge were 1.09% (95% CI, 0.85%-1.33%) for patients undergoing TPKA and 0.53% (95% CI, 0.35%-0.70%) for those undergoing TPHA. The pooled rates of symptomatic DVT were 0.63% (95% CI, 0.47%-0.78%) for knee arthroplasty and 0.26% (95% CI, 0.14%-0.37%) for hip arthroplasty. The pooled rates for pulmonary embolism were 0.27% (95% CI, 0.16%-0.38%) for knee arthroplasty and 0.14% (95% CI, 0.07%-0.21%) for hip arthroplasty. There was significant heterogeneity for the pooled incidence rates of symptomatic postoperative VTE in TPKA studies but less heterogeneity for DVT and pulmonary embolism in TPKA studies and for VTE, DVT, and pulmonary embolism in TPHA studies. CONCLUSION: Using current VTE prophylaxis, approximately 1 in 100 patients undergoing TPKA and approximately 1 in 200 patients undergoing TPHA develops symptomatic VTE prior to hospital discharge.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Universal standard goniometer is an essential tool to measure articulations' range of motion (ROM). In this time of technological advances and increasing use of smartphones, new measurement's tools appear as specific smartphone applications. This article compares the iOS application "Knee Goniometer" with universal standard goniometer to assess knee ROM. To our knowledge, this is the first study that uses a goniometer application in a clinical context. The purpose of this study is to determine if this application could be used in clinical practice.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study is a long-term analysis of a group of patients with infected arthroplasties of the hip or the knee. We identified 28 patients with an infected arthroplasty (22 hips, 6 knees) documented by bacterial culture or on direct examination. At the time of diagnosis and on follow-up (a mean of 46 months after treatment) we evaluated the clinical picture, the radiological appearances of the articulation and the biological parameters. 19/28 patients showed a typical clinical picture, whereas in 9 others the picture was more doubtful. The treatments were 14 two-stage replacements of the arthroplasties, 7 simple resections, 5 conservative treatments and 2 one-stage replacements. On follow-up, 25 patients were considered as cured of their infection and 3 as failures. From a functional viewpoint, 9 patients showed no limitation, whereas 19 were limited in the daily activity. Half of the patients had no pain. Radiology showed that 20/26 evaluated patients had no signs of recurrence. Paraclinical examinations are important in the diagnosis of persistent low grade infections, particularly the demonstration of bacteria by pre-surgical sampling (fine needle aspiration, culture from draining sinuses). In spite of the cure of infection, the functional and painful sequellae are often considerable. As a result of our experience, we recommend a two-stage surgical procedure. Only when the general condition of the patient is poor, or when the infection is not under control, would we envisage an alternative procedure (arthrodesis, girdelstone, conservative).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study investigated the influence of two warm-up protocols on neural and contractile parameters of knee extensors. A series of neuromuscular tests including voluntary and electrically evoked contractions were performed before and after running- (R (WU); slow running, athletic drills, and sprints) and strength-based (S (WU); bilateral 90 degrees back squats, Olympic lifting movements and reactivity exercises) warm ups (duration ~40 min) in ten-trained subjects. The estimated overall mechanical work was comparable between protocols. Maximal voluntary contraction torque (+15.6%; P < 0.01 and +10.9%; P < 0.05) and muscle activation (+10.9 and +12.9%; P < 0.05) increased to the same extent after R (WU) and S (WU), respectively. Both protocols caused a significant shortening of time to contract (-12.8 and -11.8% after R (WU) and S (WU); P < 0.05), while the other twitch parameters did not change significantly. Running- and strength-based warm ups induce similar increase in knee extensors force-generating capacity by improving the muscle activation. Both protocols have similar effects on M-wave and isometric twitch characteristics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The rehabilitation process after total knee arthroplasty (TKA) relies more and more on the family doctor. Many factors contribute to this development: the constantly increasing number of TKA performed, the reduced length of stay at the hospital and the rehabilitation process after TKA requiring care for 3 to 4 months. After this time, it is also of major importance to encourage patients to take up physical activities in order to limit the negative effects of sedentarity. The goal of this paper is to give family doctors an overview of the current knowledge in the area of rehabilitation after TKA for physicians.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND AND PURPOSE: Electrical bioimpedance spectroscopy (BIS) allows the evaluation of limb extracellular fluid (R0) and total fluid (Rinf). BIS could facilitate post-surgical oedema evaluation after total knee arthroplasty (TKA), as it is easily performed and is non-invasive. However, neither its applicability in this context nor the influence of metallic implants on measurement has been evaluated. The aim of this study was to evaluate the influence of TKA implants on the BIS R0 and Rinf variables used for oedema evaluation. METHOD: This was a prospective non-randomized comparative clinical trial. One oedema-free group of patients with TKA was compared with a group presenting similar characteristics except for the arthroplasty, to assess the influence of the implant on BIS measurement in the absence of oedema. The TKA group included 15 patients who had undergone surgery more than a year previously, and the control group included 19 patients awaiting TKA surgery. Volume and perimeter measurements served as reference criterions. The lower limb percentage differences for BIS, knee perimeter and volume were calculated. The significance of differences between groups was calculated for all measurement methods, using the Mann-Whitney test. The setting was a Department of Orthopedic Surgery and Traumatology in a university hospital. RESULTS: The differences between groups were not significant for R0, Rinf, volume and perimeter. R0 showed the smallest mean difference in limb percentage difference between groups [means (SD): TKA 3.98 (8.09), controls 3.97 (5.16)]. CONCLUSIONS: The lower-leg percentage difference in the TKA group is comparable with that of healthy subjects. R0 can be used for oedema evaluation following TKA surgery, as there was no sign of alteration from the metallic implant. These findings indicate the potential for early oedema evaluation after TKA. More research is warranted to extensively validate the application of BIS for oedema evaluation after TKA. Copyright © 2012 John Wiley & Sons, Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study was to determine the impact of axial traction during acquisition of direct magnetic resonance (MR) arthrography examination of the knee in terms of joint space width and amount of contrast material between the cartilage surfaces. Direct knee MR arthrography was performed in 11 patients on a 3-T MR imaging unit using a T1-weighted isotropic gradient echo sequence in a coronal plane with and without axial traction of 15 kg. Joint space widths were measured at the level of the medial and the lateral femorotibial joint with and without traction. The amount of contrast material in the medial and lateral femorotibial joint was assessed independently by two musculoskeletal radiologists in a semiquantitative manner using three grades ('absence of surface visualization, 'partial surface visualization or 'complete surface visualization'). With traction, joint space width increased significantly at the lateral femorotibial compartment (mean = 0.55 mm, p = 0.0105) and at the medial femorotibial compartment (mean = 0.4 mm, p = 0.0124). There was a trend towards an increased amount of contrast material in the femorotibial compartment with axial traction. Direct MR arthrography of the knee with axial traction showed a slight and significant increase of the width of the femorotibial compartment with a trend towards more contrast material between the articular cartilage surfaces.