905 resultados para Incomplete Block-designs
Resumo:
This study deals with the statistical properties of a randomization test applied to an ABAB design in cases where the desirable random assignment of the points of change in phase is not possible. In order to obtain information about each possible data division we carried out a conditional Monte Carlo simulation with 100,000 samples for each systematically chosen triplet. Robustness and power are studied under several experimental conditions: different autocorrelation levels and different effect sizes, as well as different phase lengths determined by the points of change. Type I error rates were distorted by the presence of autocorrelation for the majority of data divisions. Satisfactory Type II error rates were obtained only for large treatment effects. The relationship between the lengths of the four phases appeared to be an important factor for the robustness and the power of the randomization test.
Resumo:
N = 1 designs imply repeated registrations of the behaviour of the same experimental unit and the measurements obtained are often few due to time limitations, while they are also likely to be sequentially dependent. The analytical techniques needed to enhance statistical and clinical decision making have to deal with these problems. Different procedures for analysing data from single-case AB designs are discussed, presenting their main features and revising the results reported by previous studies. Randomization tests represent one of the statistical methods that seemed to perform well in terms of controlling false alarm rates. In the experimental part of the study a new simulation approach is used to test the performance of randomization tests and the results suggest that the technique is not always robust against the violation of the independence assumption. Moreover, sensitivity proved to be generally unacceptably low for series lengths equal to 30 and 40. Considering the evidence available, there does not seem to be an optimal technique for single-case data analysis
Resumo:
The present study evaluates the performance of four methods for estimating regression coefficients used to make statistical decisions regarding intervention effectiveness in single-case designs. Ordinary least squares estimation is compared to two correction techniques dealing with general trend and one eliminating autocorrelation whenever it is present. Type I error rates and statistical power are studied for experimental conditions defined by the presence or absence of treatment effect (change in level or in slope), general trend, and serial dependence. The results show that empirical Type I error rates do not approximate the nominal ones in presence of autocorrelation or general trend when ordinary and generalized least squares are applied. The techniques controlling trend show lower false alarm rates, but prove to be insufficiently sensitive to existing treatment effects. Consequently, the use of the statistical significance of the regression coefficients for detecting treatment effects is not recommended for short data series.
Resumo:
Monte Carlo simulations were used to generate data for ABAB designs of different lengths. The points of change in phase are randomly determined before gathering behaviour measurements, which allows the use of a randomization test as an analytic technique. Data simulation and analysis can be based either on data-division-specific or on common distributions. Following one method or another affects the results obtained after the randomization test has been applied. Therefore, the goal of the study was to examine these effects in more detail. The discrepancies in these approaches are obvious when data with zero treatment effect are considered and such approaches have implications for statistical power studies. Data-division-specific distributions provide more detailed information about the performance of the statistical technique.
Resumo:
Chest pain is a common presenting symptom in emergency departments, and a typical manifestation of acute myocardial infarction (AMI). Recognition of ECG changes in AMI is essential for timely diagnosis and treatment. Right bundle branch block (RBBB) may be an isolated sign of AMI, and was previously considered as a criterion for fibrinolytic therapy. Since the most recent European Society of Cardiology and American Heart Association guidelines in 2013, RBBB alone is no longer considered a diagnostic criterion of AMI, even if it occurs in the context of acute chest pain, as RBBB does not usually interfere with the interpretation of ST-segment alteration. Our case illustrates an acute septal myocardial infarction with an isolated RBBB, and thus the importance of recognising this pattern in order to permit timely diagnosis and treatment.
Resumo:
Objectives: The purpose of this study is to determine the possible differences in deflection between two needles of same length and external gauge but with different internal gauges during truncal block of the inferior alveolar nerve. The initial working hypothesis was that greater deflection may be expected with larger internal gauge needles. Study design: Four clinicians subjected 346 patients to inferior alveolar nerve block and infiltrating anesthesia of the buccal nerve trajectory for the surgical or conventional extraction of the lower third molar. A nonautoaspirating syringe system with 2 types of needle was used: a standard 27-gauge x 35-mm needle with an internal gauge of 0.215 mm or an XL Monoprotect® 27-gauge x 35-mm needle with an internal gauge of 0.265 mm. The following information was systematically recorded for each patient: needle type, gender, anesthetic technique (direct or indirect truncal block) and the number of bone contacts during the procedure, the patient-extraction side, the practitioner performing the technique, and blood aspiration (either positive or negative). Results: 346 needles were used in total. 190 were standard needles (27-gauge x 35-mm needle with an internal gauge of 0.215 mm) and 156 were XL Monoprotect®. Incidence of deflection was observed in 49.1% of cases (170 needles) where 94 were standard needles and 76 XL Monoprotect®. Needle torsion ranged from 0º and 6º. Conclusions: No significant differences were recorded in terms of deflection and internal gauge, operator, patient-extraction side, the anesthetic technique involved and the number of bone contacts during the procedure
Resumo:
Newly generated olfactory receptor axons grow from the peripheral to the central nervous system aided by olfactory ensheathing cells (OECs). Thus, OEC transplantation has emerged as a promising therapy for spinal cord injuries and for other neural diseases. However, these cells do not present a uniform population, but, instead, a functionally heterogeneous population that exhibits a variety of responses including adhesion, repulsion and crossover during cell-cell and cell-matrix interactions. Some studies report that the migratory properties of OECs are compromised by inhibitory molecules and potentiated by chemical gradients. Here, we demonstrated that rodent OECs express all the components of the Nogo Receptor complex and that their migration is blocked by Myelin. Next, we used cell tracking and traction force microscopy to analyze OEC migration and its mechanical properties over Myelin. Our data relate the absence of traction force of OEC with lower migratory capacity, which correlates with changes in the F-Actin cytoskeleton and focal adhesion distribution. Lastly, OEC traction force and migratory capacity is enhanced after cell incubation with the Nogo Receptor inhibitor NEP1-40.
Resumo:
Differences in parasite transmission intensity influence the process of acquisition of host immunity to Plasmodium falciparum malaria and ultimately, the rate of malaria related morbidity and mortality. Potential vaccines being designed to complement current intervention efforts therefore need to be evaluated against different malaria endemicity backgrounds. The associations between antibody responses to the chimeric merozoite surface protein 1 block 2 hybrid (MSP1 hybrid), glutamate-rich protein region 2 (GLURP R2) and the peptide AS202.11, and the risk of malaria were assessed in children living in malaria hyperendemic (Burkina Faso, n = 354) and hypo-endemic (Ghana, n = 209) areas. Using the same reagent lots and standardized protocols for both study sites, immunoglobulin (Ig) M, IgG and IgG sub-class levels to each antigen were measured by ELISA in plasma from the children (aged 6-72 months). Associations between antibody levels and risk of malaria were assessed using Cox regression models adjusting for covariates. There was a significant association between GLURP R2 IgG3 and reduced risk of malaria after adjusting age of children in both the Burkinabe (hazard ratio 0.82; 95 % CI 0.74-0.91, p < 0.0001) and the Ghanaian (HR 0.48; 95 % CI 0.25-0.91, p = 0.02) cohorts. MSP1 hybrid IgM was associated (HR 0.85; 95 % CI 0.73-0.98, p = 0.02) with reduced risk of malaria in Burkina Faso cohort while IgG against AS202.11 in the Ghanaian children was associated with increased risk of malaria (HR 1.29; 95 % CI 1.01-1.65, p = 0.04). These findings support further development of GLURP R2 and MSP1 block 2 hybrid, perhaps as a fusion vaccine antigen targeting malaria blood stage that can be deployed in areas of varying transmission intensity.
Resumo:
BACKGROUND: Hemidiaphragmatic paresis after ultrasound-guided interscalene brachial plexus block is reported to occur in up to 100% of patients. We tested the hypothesis that an injection lateral to the brachial plexus sheath reduces the incidence of hemidiaphragmatic paresis compared with a conventional intrafascial injection, while providing similar analgesia. METHODS: Forty ASA I-III patients undergoing elective shoulder and clavicle surgery under general anaesthesia were randomized to receive an ultrasound-guided interscalene brachial plexus block for analgesia, using 20 ml bupivacaine 0.5% with epinephrine 1:200 000 injected either between C5 and C6 within the interscalene groove (conventional intrafascial injection), or 4 mm lateral to the brachial plexus sheath (extrafascial injection). The primary outcome was incidence of hemidiaphragmatic paresis (diaphragmatic excursion reduction >75%), measured by M-mode ultrasonography, before and 30 min after the procedure. Secondary outcomes were forced vital capacity, forced expiratory volume in 1 s, and peak expiratory flow. Additional outcomes included time to first opioid request and pain scores at 24 h postoperatively (numeric rating scale, 0-10). RESULTS: The incidences of hemidiaphragmatic paresis were 90% (95% CI: 68-99%) and 21% (95% CI: 6-46%) in the conventional and extrafascial injection groups, respectively (P<0.0001). Other respiratory outcomes were significantly better preserved in the extrafascial injection group. The mean time to first opioid request was similar between groups (conventional: 802 min [95% CI: 620-984 min]; extrafascial: 973 min [95% CI: 791-1155 min]; P=0.19) as were pain scores at 24 h postoperatively (conventional: 1.6 [95% CI: 0.9-2.2]; extrafascial: 1.6 [95% CI: 0.8-2.4]; P=0.97). CONCLUSIONS: Ultrasound-guided interscalene brachial plexus block with an extrafascial injection reduces the incidence of hemidiaphragmatic paresis and impact on respiratory function while providing similar analgesia, when compared with a conventional injection. CLINICAL TRIAL REGISTRATION: NCT02074397.
Resumo:
Objective: To analyze anatomical variations associated with celiac plexus complex by means of computed tomography simulation, assessing the risk for organ injury as the transcrural technique is utilized. Materials and Methods: One hundred eight transaxial computed tomography images of abdomen were analyzed. The aortic-vertebral, celiac trunk (CeT)-vertebral, CeT-aortic and celiac-aortic-vertebral topographical relationships were recorded. Two needle insertion pathways were drawn on each of the images, at right and left, 9 cm and 4.5 cm away from the midline. Transfixed vital organs and gender-related associations were recorded. Results: Aortic-vertebral - 45.37% at left and 54.62% in the middle; CeT-vertebral - T12, 36.11%; T12-L1, 32.4%; L1, 27.77%; T11-T12, 2.77%; CeT-aortic - 53.7% at left and 46.3% in the middle; celiac-aortic-vertebral - L-l, 22.22%; M-m, 23.15%; L-m, 31.48%; M-l, 23.15%. Neither correspondence on the right side nor significant gender-related associations were observed. Conclusion: Considering the wide range of abdominal anatomical variations and the characteristics of needle insertion pathways, celiac plexus block should not be standardized. Imaging should be performed prior to the procedure in order to reduce the risks for injuries or for negative outcomes to patients. Gender-related anatomical variations involved in celiac plexus block should be more deeply investigated, since few studies have addressed the subject.
Resumo:
Introduction : Le bloc transverse de l'abdomen (bloc TAP, Transversus Abdominis Plane) échoguidé consiste en l'injection d'anesthésique local dans la paroi abdominale entre les muscles oblique interne et transverse de l'abdomen sous contrôle échographique. Ceci permet de bloquer l'innervation sensitive de la paroi antérolatérale de l'abdomen afin de soulager la douleur après des interventions chirurgicales. Auparavant, cette procédure reposait sur une technique dite « à l'aveugle » qui utilisait des repères anatomiques de surface. Depuis quelques années, cette technique est effectuée sous guidage échographique ; ainsi, il est possible de visualiser les structures anatomiques, l'aiguille et l'anesthésique local permettant ainsi une injection précise de l'anesthésique local à l'endroit désiré. Les précédentes méta- analyses sur le bloc TAP n'ont inclus qu'un nombre limité d'articles et n'ont pas examiné l'effet analgésique spécifique de la technique échoguidée. L'objectif de cette méta-analyse est donc de définir l'efficacité analgésique propre du bloc TAP échoguidé après des interventions abdominales chez une population adulte. Méthode : Cette méta-analyse a été effectuée selon les recommandations PRISMA. Une recherche a été effectuée dans les bases de donnée MEDLINE, Cochrane Central Register of Controlled Clinical Trials, Excerpta Medica database (EMBASE) et Cumulative Index to Nursing and Allied Health Literature (CINAHL). Le critère de jugement principal est la consommation intraveineuse de morphine cumulée à 6 h postopératoires, analysée selon le type de chirurgie (laparotomie, laparoscopie, césarienne), la technique anesthésique (anesthésie générale, anesthésie spinale avec/ou sans morphine intrathécale), le moment de l'injection (début ou fin de l'intervention), et la présence ou non d'une analgésie multimodale. Les critères de jugement secondaires sont, entre autres, les scores de douleur au repos et à l'effort à 6 h postopératoires (échelle analogique de 0 à 100), la présence ou non de nausées et vomissements postopératoires, la présence ou non de prurit, et le taux de complications de la technique. Résultats : Trente et une études randomisées contrôlées, incluant un total de 1611 adultes ont été incluses. Indépendamment du type de chirurgie, le bloc TAP échoguidé réduit la consommation de morphine à 6 h postopératoires (différence moyenne : 6 mg ; 95%IC : -7, -4 mg ; I =94% ; p<0.00001), sauf si les patients sont au bénéfice d'une anesthésie spinale avec morphine intrathécale. Le degré de réduction de consommation de morphine n'est pas influencé par le moment de l'injection (I2=0% ; p=0.72) ou la présence d'une analgésie multimodale (I2=73% ; p=0.05). Les scores de douleurs au repos et à l'effort à 6h postopératoire sont également réduits (différence moyenne au repos : -10 ; 95%IC : -15, -5 ; I =92% ; p=0.0002; différence moyenne en mouvement : -9 ; 95%IC : -14, -5 ; I2=58% ; p<0. 00001). Aucune différence n'a été retrouvée au niveau des nausées et vomissements postopératoires et du prurit. Deux complications mineures ont été identifiées (1 hématome, 1 réaction anaphylactoïde sur 1028 patients). Conclusions : Le bloc TAP échoguidé procure une analgésie postopératoire mineure et ne présente aucun bénéfice chez les patients ayant reçu de la morphine intrathécale. L'effet analgésique mineure est indépendant du moment de l'injection ou de la présence ou non d'une analgésie multimodale.