968 resultados para Implicit calibration


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents a method for analyzing electromagnetic transients using real transformation matrices in three-phase systems considering the presence of ground wires. So, for the Z and Y matrices that represent the transmission line, the characteristics of ground wires are not implied in the values related to the phases. A first approach uses a real transformation matrix for the entire frequency range considered in this case. This transformation matrix is an approximation to the exact transformation matrix. For those elements related to the phases of the considered system, the transformation matrix is composed of the elements of Clarke's matrix. In part related to the ground wires, the elements of the transformation matrix must establish a relationship with the elements of the phases considering the establishment of a single homopolar reference in the mode domain. In the case of three-phase lines with the presence of two ground wires, it is unable to get the full diagonalization of the matrices Z and Y in the mode domain. This leads to the second proposal for the composition of real transformation matrix: obtain such transformation matrix from the multiplication of two real and constant matrices. In this case, the inclusion of a second matrix had the objective to minimize errors from the first proposal for the composition of the transformation matrix mentioned. © 2012 IEEE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Includes bibliography

Relevância:

20.00% 20.00%

Publicador:

Resumo:

ABSTRACT: The application of multivariate calibration techniques to multicomponent analysis by UV-VIS molecular absorption spectrometry is a powerful tool for simultaneous determination of several chemical species. However, when this methodology is accomplished manually, it is slow and laborious, consumes high amounts of reagents and samples, is susceptible to contaminations and presents a high operational cost. To overcome these drawbacks, a flow-batch analyser is proposed in this work. This analyser was developed for automatic preparation of standard calibration and test (or validation) mixtures. It was applied to the simultaneous determination of Cu2+, Mn2+ and Zn2+ in polyvitaminic and polymineral pharmaceutical formulations, using 4-(2-piridilazo) resorcinol as reagent and a UV-VIS spectrophotometer with a photodiode array detector. The results obtained with the proposed system are in good agreement with those obtained by flame atomic absorption spectrometry, which was employed as reference method. With the proposed analyser, the preparation of calibration and test mixtures can be accomplished about four hours, while the manual procedure requires at least two days. Moreover, it consumes smaller amounts of reagents and samples than the manual procedure. After the preparation of calibration and test mixtures, 60 samples-1 can be carried out with the proposed flow-batch analyser.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Vibration monitoring requires acceleration transducers capable of providing data with high precision. Accelerometers are the most frequently used vibration transducers. Their calibration plays an important role in measuring vibrations and is a key component in ensuring the integrity of the vibration measurement. For managing secondary calibration data of accelerometers, a database computer system was implemented. The implementation of this software has been an important step forward in providing a wide range of analysis and display tools. This paper reviews the main concepts involving accelerometer secondary calibration and describes the tool developed and the methods used in its development. (C) 2013 Academie des sciences. Published by Elsevier Masson SAS. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to investigate the effects of explicit and implicit knowledge about visual surrounding manipulation on postural responses. Twenty participants divided into two groups, implicit and explicit, remained in upright stance inside a moving room. In the fourth trial participants in the explicit group were informed about the movement of the room while participants in the implicit group performed the trial with the room moving at a larger amplitude and higher velocity. Results showed that postural responses to visual manipulation decreased after participants were told that the room was moving as well as after increasing amplitude and velocity of the room, indicating decreased coupling (down-weighting) of the visual influences. Moreover, this decrease was even greater for the implicit group compared to the explicit group. The results demonstrated that conscious knowledge about environmental state changes the coupling to visual information, suggesting a cognitive component related to sensory re-weighting. Re-weighting processes were also triggered without awareness of subjects and were even more pronounced compared to the first case. Adaptive re-weighting was shown when knowledge about environmental state was gathered explicitly and implicitly, but through different adaptive processes. (C) 2014 Elsevier Ireland Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this note we show that the roots of a polynomial are C∞ depend of the coefficients. The main tool to show this is the Implicit Function Theorem.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We study implicit ODEs, cubic in derivative, with infinitesimal symmetry at singular points. Cartan showed that even at regular points the existence of nontrivial symmetry imposes restrictions on the ODE. Namely, this algebra has the maximal possible dimension 3 iff the web of solutions is flat. For cubic ODEs with flat 3-web of solutions we establish sufficient conditions for the existence of nontrivial symmetries at singular points and show that under natural assumptions such a symmetry is semi-simple, i.e. is a scaling is some coordinates. We use this symmetry to find first integrals of the ODE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the paper, the set-valued covering mappings are studied. The statements on solvability, solution estimates, and well-posedness of inclusions with conditionally covering mappings are proved. The results obtained are applied to the investigation of differential inclusions unsolved for the unknown function. The statements on solvability, solution estimates, and well-posedness of these inclusions are derived.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To compare two methods of respiratory inductive plethysmography (RIP) calibration in three different positions. Methods: We evaluated 28 healthy subjects (18 women and 10 men), with a mean age of 25.4 +/- 3.9 years. For all of the subjects, isovolume maneuver calibration (ISOCAL) and qualitative diagnostic calibration (QDC) were used in the orthostatic, sitting, and supine positions. In order to evaluate the concordance between the two calibration methods, we used ANOVA and Bland-Altman plots. Results: The values of the constant of proportionality (X) were significantly different between ISOCAL and QDC in the three positions evaluated: 1.6 +/- 0.5 vs. 2.0 +/- 1.2, in the supine position, 2.5 +/- 0.8 vs. 0.6 +/- 0.3 in the sitting position, and 2.0 +/- 0.8 vs. 0.6 +/- 0.3 in the orthostatic position (p < 0.05 for all). Conclusions: Our results suggest that QDC is an inaccurate method for the calibration of RIP. The K values obtained with ISOCAL reveal that RIP should be calibrated for each position evaluated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The leaf area index (LAI) is a key characteristic of forest ecosystems. Estimations of LAI from satellite images generally rely on spectral vegetation indices (SVIs) or radiative transfer model (RTM) inversions. We have developed a new and precise method suitable for practical application, consisting of building a species-specific SVI that is best-suited to both sensor and vegetation characteristics. Such an SVI requires calibration on a large number of representative vegetation conditions. We developed a two-step approach: (1) estimation of LAI on a subset of satellite data through RTM inversion; and (2) the calibration of a vegetation index on these estimated LAI. We applied this methodology to Eucalyptus plantations which have highly variable LAI in time and space. Previous results showed that an RTM inversion of Moderate Resolution Imaging Spectroradiometer (MODIS) near-infrared and red reflectance allowed good retrieval performance (R-2 = 0.80, RMSE = 0.41), but was computationally difficult. Here, the RTM results were used to calibrate a dedicated vegetation index (called "EucVI") which gave similar LAI retrieval results but in a simpler way. The R-2 of the regression between measured and EucVI-simulated LAI values on a validation dataset was 0.68, and the RMSE was 0.49. The additional use of stand age and day of year in the SVI equation slightly increased the performance of the index (R-2 = 0.77 and RMSE = 0.41). This simple index opens the way to an easily applicable retrieval of Eucalyptus LAI from MODIS data, which could be used in an operational way.