975 resultados para Imaging diagnostic agents
Resumo:
Despite its recognized value in detecting and characterizing breast disease, X-ray mammography has important limitations that motivate the quest for alternatives to augment the diagnostic tools that are currently available to the radiologist. The rationale for pursuing electromagnetic methods are based on the significant dielectric contrast between normal and cancerous breast tissues, when exposed to microwaves. The present study analyzes two-dimensional microwave tomographic imaging on normal and malignant breast tissue samples extracted by mastectomy, to assess the suitability of the technique for early detection ofbreast cancer. The tissue samples are immersed in matching coupling medium and are illuminated by 3 GHz signal. 2-D tomographic images ofthe breast tissue samples are reconstructed from the collected scattered data using distorted Born iterative method. Variations of dielectric permittivity in breast samples are distinguishable from the obtained permittivity profiles, which is a clear indication of the presence of malignancy. Hence microwave tomographic imaging is proposed as an alternate imaging modality for early detection ofbreast cancer.
Resumo:
The present thesis report the results obtained from the studies carried out on the laser blow off plasma (LBO) from LiF-C (Lithium Fluoride with Carbon) thin film target, which is of particular importance in Tokamak plasma diagnostics. Keeping in view of its significance, plasma generated by the irradiation of thin film target by nanosecond laser pulses from an Nd:YAG laser over the thin film target has been characterized by fast photography using intensified CCD. In comparison to other diagnostic techniques, imaging studies provide better understanding of plasma geometry (size, shape, divergence etc) and structural formations inside the plume during different stages of expansion.
Resumo:
Fluorescence is a powerful tool in biological research, the relevance of which relies greatly on the availability of sensitive and selective fluorescent probes. Nanometer sized fluorescent semiconductor materials have attracted considerable attention in recent years due to the high luminescence intensity, low photobleaching, large Stokes’ shift and high photochemical stability. The optical and spectroscopic features of nanoparticles make them very convincing alternatives to traditional fluorophores in a range of applications. Efficient surface capping agents make these nanocrystals bio-compatible. They can provide a novel platform on which many biomolecules such as DNA, RNA and proteins can be covalently linked. In the second phase of the present work, bio-compatible, fluorescent, manganese doped ZnS (ZnS:Mn) nanocrystals suitable for bioimaging applications have been developed and their cytocompatibility has been assessed. Functionalization of ZnS:Mn nanocrystals by safe materials results in considerable reduction of toxicity and allows conjugation with specific biomolecules. The highly fluorescent, bio-compatible and water- dispersible ZnS:Mn nanocrystals are found to be ideal fluorescent probes for biological labeling
Resumo:
Multimodal imaging agents that combine magnetic and fluorescent imaging capabilities are desirable for the high spatial and temporal resolution. In the present work, we report the synthesis of multifunctional fluorescent ferrofluids using iron oxide as the magnetic core and rhodamine B as fluorochrome shell. The core–shell structure was designed in such a way that fluorescence quenching due to the inner magnetic core was minimized by an intermediate layer of silica. The intermediate passive layer of silica was realized by a novel method which involves the esterification reaction between the epoxy group of prehydrolysed 3-Glyidoxypropyltrimethoxysilane and the surfactant over iron oxide. The as-synthesized ferrofluids have a high saturation magnetization in the range of 62–65 emu/g and were found to emit light of wavelength 640 nm ( excitation = 446 nm). Time resolved life time decay analysis showed a bi-exponential decay pattern with an increase in the decay life time in the presence of intermediate silica layer. Cytotoxicity studies confirmed the cell viability of these materials. The in vitro MRI imaging illustrated a high contrast when these multimodal nano probes were employed and the R2 relaxivity of these ∗Author to whom correspondence should be addressed. Email: smissmis@gmail.com sample was found to be 334 mM−1s−1 which reveals its high potential as a T2 contrast enhancing agent
Resumo:
Introducción: los tumores neuroendocrinos gastroenteropancreáticos se diagnostican en estadio avanzado en 60 - 80% de los pacientes y las opciones terapéuticas son limitadas. Se realizó una revisión sobre el beneficio clínico del tratamiento con [177Lu - DOTA - Tyr3] - Octreotate en pacientes con enfermedad metastásica o inoperable. Objetivos: evaluar la eficacia, impacto en calidad de vida y toxicidad de la terapia con 177Lu DOTATE en pacientes con tumores neuroendocrinos gastroenteropancreáticos avanzados. Materiales y Métodos: se condujo una revisión sistemática de la literatura mediante la búsqueda de estudios clínicos prospectivos y retrospectivos en bases electrónicas (MEDLINE, EMBASE, LILACS, SCIELO, OVID y la Biblioteca Cochrane) de cualquier idioma, año y estado de publicación. Se incluyeron 5 estudios, por la heterogeneidad existente entre los estudios no se realizó un metaanálisis. Resultados: la respuesta tumoral global fue del 45 - 57%, la enfermedad permaneció estable en 27% - 38% y progresó en 6% - 21% de casos en las series incluidas. El tiempo libre de progresión osciló entre 31 - 40 meses y la sobrevida global de 31– 51 meses. Se observó toxicidad hematológica grado 3-4 hasta en 9.5% de pacientes. Hubo mejoría significativa en la calidad de vida de pacientes tratados con 177LuDOTATATE. Conclusiones: la terapia con 177Lu- DOTATATE ofrece un beneficio clínico a los pacientes con tumores neuroendocrinos bien diferenciados avanzados por su impacto positivo en calidad de vida, control de síntomas, ralentiza la progresión tumoral y su toxicidad es baja.
Resumo:
El manejo de la obstrucción intestinal por adherencias es un reto para cualquier especialista en Cirugía debido a que existe controversia sobre el alcance del manejo médico y el momento adecuado para llevar el paciente a cirugía para la resolución del cuadro clínico. En el presente trabajo se pretende, identificar los factores asociados a tratamiento quirúrgico en pacientes con obstrucción intestinal por adherencias. Metodología: Se realizó un estudio de casos y controles en una relación de 1:1, con una recolección de muestra estadística de 48 pacientes en cada grupo, entre mayo 2012 y mayo 2014 en el Hospital Universitario Mayor Mederi y en Barrios Unidos. Se consideraron casos los pacientes intervenidos quirúrgicamente por obstrucción intestinal por bridas y controles los pacientes manejados con tratamiento médico. Se evaluaron factores como edad, antecedentes personales patológicos y quirúrgicos, tiempo de evolución del cuadro clínico, hallazgos en imágenes y laboratorio entre otros. Resultados: Se recolectaron un total de 158 pacientes, (78 casos, 80 controles). Ambas poblaciones fueron comparables (p=0.13). Los factores asociados a tratamiento quirúrgico estadísticamente significativos fueron género masculino, presencia de fiebre al ingreso, el hallazgo de engrosamiento de la pared intestinal y de obstrucción de asa cerrada en imágenes diagnósticas (p<0,05). Discusión: Los principales factores asociados para que un paciente con obstrucción intestinal por bridas requiera de manejo quirúrgico son consistentes con literatura. Se requiere la socialización de los resultados para disminuir la morbimortalidad de nuestros pacientes.
Resumo:
The chemical specificity of terahertz spectroscopy, when combined with techniques for sub-wavelength sensing, is giving new understanding of processes occurring at the nanometre scale in biological systems and offers the potential for single molecule detection of chemical and biological agents and explosives. In addition, terahertz techniques are enabling the exploration of the fundamental behaviour of light when it interacts with nanoscale optical structures, and are being used to measure ultrafast carrier dynamics, transport and localisation in nanostructures. This chapter will explain how terahertz scale modelling can be used to explore the fundamental physics of nano-optics, it will discuss the terahertz spectroscopy of nanomaterials, terahertz near-field microscopy and other sub-wavelength techniques, and summarise recent developments in the terahertz spectroscopy and imaging of biological systems at the nanoscale. The potential of using these techniques for security applications will be considered.
Resumo:
Nasoendoscopy is an important tool for assessing velopharyngeal function. The purpose of this study was to analyze velar and pharyngeal wall movement and velopharyngeal gap during nasoendoscopic evaluation of the velopharynx before and during diagnostic therapy. Nasoendoscopic recordings of 10 children with operated cleft lip and palate were analyzed according to the International Working Group Guidelines. Ratings of movement of velum and pharyngeal walls, and size, location and shape of gaps were analyzed by 3 speech-language pathologists (SLPs). Imaging was obtained during repetitions of the syllable /pa/ during a single nasoendoscopic evaluation: (a) before diagnostic therapy, and (b) after the children were instructed to impound and increase intraoral air pressure (diagnostic therapy). Once the patients impounded and directed air pressure orally, the displacement of the velum, right, left and posterior pharyngeal walls increased 40, 70, 80, and 10%, respectively. Statistical significance for displacement was found only for right and left lateral pharyngeal walls. Reduction in gap size was observed for 30% of the patients and other 40% of the gaps disappeared. Changes in gap size were found to be statistically significant between the two conditions. In nasoendoscopic assessment, the full potential of velopharyngeal displacement may not be completely elicited when the patient is asked only to repeat a speech stimulus. Optimization of information can be done with the use of diagnostic therapy's strategies to manipulate VP function. Assuring the participation of the SLP to conduct diagnostic therapy is essential for management of velopharyngeal dysfunction.
Resumo:
OBJECTIVE: To assess the cardiovascular features of Ullrich-Turner's syndrome using echocardiography and magnetic resonance imaging, and to correlate them with the phenotype and karyotype of the patients. The diagnostic concordance between the 2 methods was also assessed. METHODS: Fifteen patients with the syndrome were assessed by echocardiography and magnetic resonance imaging (cardiac chambers, valves, and aorta). Their ages ranged from 10 to 28 (mean of 16.7) years. The karyotype was analyzed in 11 or 25 metaphases of peripheral blood lymphocytes, or both. RESULTS: The most common phenotypic changes were short stature and spontaneous absence of puberal development (100%); 1 patient had a cardiac murmur. The karyotypes detected were as follows: 45,X (n=7), mosaics (n=5), and deletions (n=3). No echocardiographic changes were observed. In regard to magnetic resonance imaging, coarctation and dilation of the aorta were found in 1 patient, and isolated dilation of the aorta was found in 4 patients. CONCLUSION: The frequencies of coarctation and dilation of the aorta detected on magnetic resonance imaging were similar to those reported in the literature (5.5% to 20%, and 6.3% to 29%, respectively). This confirmed the adjuvant role of magnetic resonance imaging to Doppler echocardiography for diagnosing cardiovascular alterations in patients with Ullrich-Turner's syndrome.
Resumo:
In the present experimental study we assessed induced osteoarthritis data in rabbits, compared three diagnostic methods, i.e., radiography (XR), computed tomography (CT) and magnetic resonance imaging (MRI), and correlated the imaging findings with those obtained by macroscopic evaluation. Ten young female rabbits of the Norfolk breed were used. Seven rabbits had the right knee immobilized in extension for a period of 12 weeks (immobilized group), and three others did not have a limb immobilized and were maintained under the same conditions (control group). Alterations observed by XR, CT and MRI after the period of immobilization were osteophytes, osteochondral lesions, increase and decrease of joint space, all of them present both in the immobilized and non-immobilized contralateral limbs. However, a significantly higher score was obtained for the immobilized limbs (XT: P = 0.016, CT: P = 0.031, MRI: P = 0.0156). All imaging methods were able to detect osteoarthritis changes after the 12 weeks of immobilization. Macroscopic evaluation identified increased thickening of joint capsule, proliferative and connective tissue in the femoropatellar joint, and irregularities of articular cartilage, especially in immobilized knees. The differences among XR, CT and MRI were not statistically significant for the immobilized knees. However, MRI using a 0.5 Tesla scanner was statistically different from CT and XR for the non-immobilized contralateral knees. We conclude that the three methods detected osteoarthritis lesions in rabbit knees, but MRI was less sensitive than XR and CT in detecting lesions compatible with initial osteoarthritis. Since none of the techniques revealed all the lesions, it is important to use all methods to establish an accurate diagnosis.
Resumo:
1. Immunocytochemical procedures have played an increasingly larger role in the identification of infectious disease agents in tissue sections owing to the increased availability and specificity of antibody reagents, the great sensitivity of the methods, and the relative facility with which the studies are performed.2. Immunocytochemical methods can be applied to routine formalin-fixed tissue for the detection of infectious agents such as viruses, bacteria, fungi, and protozoa among other microorganisms for diagnostic and research purposes.
Resumo:
Purpose: To evaluate the accuracy of approximal caries detection comparing enhanced and unenhanced Sidexis CCD-based digital image with Ektaspeed Plus and INSIGHT films. Methods: Fifty-two extracted premolars were imaged under identical standardized geometric and exposure conditions. Four observers, using five points confidence scale, rated 104 approximal surfaces for the presence or absence of carious lesions by means of four image modalities: (1) observer enhanced; (2) unenhanced Sidexis displays; (3) E speed films and (4) F speed film. Histologic sections served as validating criterion for the presence and depth of carious lesions. Diagnostic accuracy was measured as the area beneath the ROC curve. Results: Mean ROC (receiver operating characteristic) curve areas for approximal surfaces were 0.865 (E speed), 0.856 (F speed), 0.816 (unenhanced Sidexis) and 0.776 (observer enhanced). There were no significant differences between unenhanced digital Sidexis and films. Observer enhanced Sidexis images exhibited a statistically significant lower diagnostic accuracy than the film images for two of the observers.
Resumo:
Objective: To evaluate the effectiveness of the Gram stain in the initial diagnosis of the etiologic agent of peritonitis in continuous ambulatory peritoneal dialysis (CAPD). Design: Retrospective study analyzing the sensitivity (S), specificity (SS), positive predictive value (+PV), and negative predictive value (-PV) of the Gram stain relating to the results of cultures in 149 episodes of peritonitis in CAPD. The data were analyzed in two studies. In the first, only the cases with detection of a single agent by Gram stain were taken (Study 1). In the second, only the cases with two agents in Gram stain were evaluated (Study 2). Setting: Dialysis Unit and Laboratory of Microbiology of a tertiary medical center. Patients: Sixty-three patients on regular CAPD who presented one or more episodes of peritonitis from May 1992 to May 1995. Results: The positivity of Gram stain was 93.2% and the sensitivity was 95.7%. The values of S, SS, +PV, and -PV were respectively: 94.9%, 53.5%, 68.3%, and 90.9% for gram-positive cocci and 83.3%, 98.8%, 95.2%, and 95.6% for gram-negative bacilli. The association of gram-positive cocci plus gram-negative bacilli were predictive of growth of both in 6.8%, growth of gram-positive cocci in 13.7%, and growth of gram-negative bacilli in 72.5%. Conclusions: The Gram stain is a method of great value in the initial diagnosis of the etiologic agent of peritonitis in CAPD, especially for gram-negative bacilli.
Resumo:
The advances in digital imaging technology in dentistry have provided an alternative to film-based radiography and have given new options to detect periodontal bone loss. The purpose of this study was to compare inverted and unprocessed digitized radiographic imaging in periodontal bone loss measurements. Thirty-five film-based periapical radiographs of patients suffering from moderate to advanced untreated periodontal bone loss associated to lower premolar and molars was selected from the department files, with 40 bone loss areas. The film-based radiographs were digitized with a flatbed scanner with a transparency and radiograph adapter used for transilluminating the radiograph imaging. Digitization was performed at 600 dpi and in gray scale. The images were digitized using Image Tool software by applying image inversion, that is, transformation of radiopaque structures into radiolucent structures and vice-versa. The digital data were saved as JPEG files. The images were displayed on a 15-inch and 24-bit video monitor under reduced room lighting. One calibrated examiner performed all radiographic measurements, three times, from the cementoenamel junction to the most apical extension of the bone loss, in both types of image (inverted and unprocessed). Brightness and contrast were adjusted according to the examiner's individual demand. Intraclass correlation coefficient was used to compare the measurements from both types of images. The means of radiographic measurements, in mm, for inverted and unprocessed digitized imaging were 6.4485 and 6.3790, respectively. The intraclass correlation coefficient was significant (0.99) The inverted and unprocessed digitized radiographic images were reliable and there was no difference in the diagnostic accuracy between these images regarding periodontal bone loss measurements.
Resumo:
The incidence of encephalic tumors in dogs and cats has increased in recent years due to the constant advancement of methods of specialist Diagnostic Imaging: Magnetic Resonance Imaging (MRI) and Computed Tomography (CT), used in small animals. These tools, which were distant in the past, are now becoming increasingly important as an additional aid to the identification of tumor processes in the Central Nervous System. The objective, of the present study, was describe imaging findings obtained in 32 cases of encephalic tumors, through techniques of CT and MR imaging procedures during the years 2004 to 2011. Were diagnosed 19/32 by MRI and 13/32 by CT, being the most affected breed Boxer (9/32), the mean age was 10 years.