982 resultados para INTRAORAL RADIOGRAPHY


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The characteristics of carbon fibre reinforced laminates had widened their use, from aerospace to domestic appliances. A common characteristic is the need of drilling for assembly purposes. It is known that a drilling process that reduces the drill thrust force can decrease the risk of delamination. In this work, delamination assessment methods based on radiographic data are compared and correlated with mechanical test results (bearing test).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this work, a comparative study on different drill point geometries and feed rate for composite laminates drilling is presented. For this goal, thrust force monitoring during drilling, hole wall roughness measurement and delamination extension assessment after drilling is accomplished. Delamination is evaluated using enhanced radiography combined with a dedicated computational platform that integrates algorithms of image processing and analysis. An experimental procedure was planned and consequences were evaluated. Results show that a cautious combination of the factors involved, like drill tip geometry or feed rate, can promote the reduction of delamination damage.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Drilling of carbon fibre/epoxy laminates is usually carried out using standard drills. However, it is necessary to adapt the processes and/or tooling as the risk of delamination, or other damages, is high. These problems can affect mechanical properties of produced parts, therefore, lower reliability. In this paper, four different drills – three commercial and a special step (prototype) – are compared in terms of thrust force during drilling and delamination. In order to evaluate damage, enhanced radiography is applied. The resulting images were then computational processed using a previously developed image processing and analysis platform. Results show that the prototype drill had encouraging results in terms of maximum thrust force and delamination reduction. Furthermore, it is possible to state that a correct choice of drill geometry, particularly the use of a pilot hole, a conservative cutting speed – 53 m/min – and a low feed rate – 0.025 mm/rev – can help to prevent delamination.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Ollier Disease and Maffucci Syndrome are two rare diseases that can cause tumors in several organs, having a special predilection for the hand. However, there have been very few reports in the literature focusing on hand manifestations of these diseases. We report the cases of three female patients: one with Ollier Disease, and two other with Maffucci Syndrome. All patients had hand involvement as their initial primary complaint. The Ollier Disease patient developed chondrosarcomas of two digits and had to have these fingers amputated. One of the Maffucci patients died one year after presentation from a brain glioblastoma. These cases emphasize the importance of early diagnosis of Ollier Disease and Maffucci Syndrome, as these two conditions are associated not only to crippling hand deformity, but also to a significant risk of chondrosarcoma, and other malignant tumors.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Nos últimos anos, a utilização dos materiais compósitos tem vindo a tornar-se cada vez mais comum em várias indústrias, onde se verifica uma ascensão na procura pelos mesmos. Características como o baixo peso aliado à sua alta resistência e rigidez permitem que estes materiais possuam diversas aplicações em variadas áreas, desde a medicina, aeronáutica, indústria automóvel e aeroespacial, até à indústria eletrónica. Hoje em dia, o uso de desperdícios sólidos de borracha e fibras naturais na produção de materiais compósitos é, mais que uma opção, uma necessidade ambiental. De forma a reduzir as enormes quantidades de desperdícios, foi criado um material compósito constituído por uma resina termoendurecível reforçada com esses dois tipos de desperdícios. Parâmetros de fabrico como a percentagem de borracha, o tamanho das partículas de borracha, a percentagem de fibras de cana-de-açúcar e o comprimento dessas fibras foram variados, com o objetivo de estudar a influência destes dois materiais nas propriedades mecânicas do compósito. Apesar da maior parte dos compósitos serem fabricados na forma de uma peça funcional quase pronta a ser utilizada, por vezes é necessário recorrer à maquinação de furos. Apesar das muitas técnicas de furação existentes, os defeitos resultantes deste processo aplicado aos materiais compósitos são ainda muito comuns. Desses defeitos o que mais se destaca é sem dúvida a delaminação. Trinta e seis provetes de epóxido reforçado com borracha e fibra de cana-de-açúcar foram fabricados e furados, de modo a possibilitar o estudo das propriedades mecânicas do material compósito, assim como a análise da zona danificada durante a furação. Diferentes condições de furação, como tipos de broca e velocidades de avanço diferentes, foram impostas aos provetes de forma a variar o mais possível a zona de dano de uns furos para os outros. Parâmetros como a área de dano ou ainda o fator de delaminação provam ser muito úteis na caracterização e quantificação do dano na zona periférica de um furo. Recorrendo a técnicas de processamento de imagem foi possível obter esses parâmetros. O processamento e análise de imagem pode ser feito através de vários métodos. O método utilizado neste trabalho foi o software MATLAB® associado a ferramentas de processamento de imagem. Depois de feita a análise dos furos foram realizados ensaios de esmagamento a todos os provetes. Este passo permitiu assim avaliar de que forma os parâmetros de furação influenciam a resistência mecânica do material, e se a avaliação realizada aos furos é um método viável para a avaliação da extensão de dano nesses furos.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This present study aimed to investigate the fatigue life of unused (new) endodontic instruments made of NiTi with control memory by Coltene™ and subjected to the multi curvature of a mandibular first molar root canal. Additionally, the instrument‟s structural behaviour was analysed through non-linear finite element analysis (FEA). The fatigue life of twelve Hyflex™ CM files was assessed while were forced to adopt a stance with multiple radius of curvature, similar to the ones usually found in a mandibular first molar root canal; nine of them were subjected to Pecking motion, a relative movement of axial type. To achieve this, it was designed an experimental setup with the aim of timing the instruments until fracture while worked inside a stainless steel mandibular first molar model with relative axial motion to simulate the pecking motion. Additionally, the model‟s root canal multi-curvature was confirmed by radiography. The non-linear finite element analysis was conducted using the computer aided design software package SolidWorks™ Simulation, in order to define the imposed displacement required by the FEA, it was necessary to model an endodontic instrument with simplified geometry using SolidWorks™ and subsequently analyse the geometry of the root canal CAD model. The experimental results shown that the instruments subjected to pecking motion displayed higher fatigue life values and higher lengths of fractured tips than those with only rotational relative movement. The finite element non-linear analyses shown, for identical conditions, maximum values for the first principal stress lower than the yield strength of the material and those were located in similar positions to the instrument‟s fracture location determined by the experimental testing results.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: To evaluate a diagnostic strategy for pulmonary embolism that combined clinical assessment, plasma D-dimer measurement, lower limb venous ultrasonography, and helical computed tomography (CT). METHODS: A cohort of 965 consecutive patients presenting to the emergency departments of three general and teaching hospitals with clinically suspected pulmonary embolism underwent sequential noninvasive testing. Clinical probability was assessed by a prediction rule combined with implicit judgment. All patients were followed for 3 months. RESULTS: A normal D-dimer level (<500 microg/L by a rapid enzyme-linked immunosorbent assay) ruled out venous thromboembolism in 280 patients (29%), and finding a deep vein thrombosis by ultrasonography established the diagnosis in 92 patients (9.5%). Helical CT was required in only 593 patients (61%) and showed pulmonary embolism in 124 patients (12.8%). Pulmonary embolism was considered ruled out in the 450 patients (46.6%) with a negative ultrasound and CT scan and a low-to-intermediate clinical probability. The 8 patients with a negative ultrasound and CT scan despite a high clinical probability proceeded to pulmonary angiography (positive: 2; negative: 6). Helical CT was inconclusive in 11 patients (pulmonary embolism: 4; no pulmonary embolism: 7). The overall prevalence of pulmonary embolism was 23%. Patients classified as not having pulmonary embolism were not anticoagulated during follow-up and had a 3-month thromboembolic risk of 1.0% (95% confidence interval: 0.5% to 2.1%). CONCLUSION: A noninvasive diagnostic strategy combining clinical assessment, D-dimer measurement, ultrasonography, and helical CT yielded a diagnosis in 99% of outpatients suspected of pulmonary embolism, and appeared to be safe, provided that CT was combined with ultrasonography to rule out the disease.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction: Calcific tendonitis of rotator cuff is observed on plainradiographs in 10% of adults, but remains asymptomatic in half thesecases. Sometimes, these calcifications induce acute flares withmassive inflammation similar to gout or CPPD crisis. Analgesics/anti-inflammatory medications are usually not sufficient to controlssymptoms in these situations. Local steroid infiltration with or withoutremoval of the calcific deposition with a needle aspiration may beuseful. A new approach could be IL-1 inhibitors. Indeed, basic calciumphosphate crystals are capable of stimulating the release of activeIL-1β in vitro. These crystals trigger IL-1β release, in an analogousmanner to MSU crystals in acute gout, suggesting that IL-1β blockademay be clinically useful.Case presentation: This report describes a 70-year old woman withacute rest pain of the right shoulder since 48 hours. On examination,we found massive limitations of active and passive movements. Thepatient evaluated, on the visual scale, her symptoms at 10/10 the nightand 5/10 the day. The radiography and showed a rounded, 8 mmcalcification in the subscapularis tendon. The ultrasound aspectrevealed a heterogeneous calcification partially non solid, surroundedby massive inflammation on Doppler. C-reactive protein anderythrocyte sedimentation rate were high (74 mg/ml, 54 mm/hour).The patient received subcutaneous injections of anakinra: 100 mgdaily for 3 days (D1-D3). We evaluated the patient in our consult at dayD1, D2, D3, D7, D16 and by phone at D70.This treatment rapidly relieved the inflammatory symptoms (within afew hours with no relapse). The mobility of the shoulder, the biologicsparameters improved and the size of the calcification as well thedegree of inflammation regressed on ultrasound after 3 days.Conclusion: This is the first report of a woman with an acute flareinduced by calcific tendonitis who received anakinra. IL-1 inhibitionmay be a therapeutic target in calcific tendonitis. To analyse thisresponse more precisely and elaborate definitive conclusions, aprospective pilot study is on-going in our ambulatory institute.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Standard chest radiographs have been shown to be insensitive for the diagnosis of morphologic abnormalities of airways. Computed tomography is the most sensitive and specific investigation to diagnose emphysema. However, as emphysema may be missed on computed tomography, this investigation cannot be used to definitely rule out the diagnosis. Computed tomography may contribute to the investigation of bronchiolitis, and it is now considered as the gold standard for establishing the diagnosis of bronchiectasis. Imaging may contribute to identify complications such as bronchopulmonary infection, pulmonary hypertension, pneumothorax, cancer of the lung, compressive bullae, and pulmonary embolism.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Studies evaluating the mechanical behavior of the trabecular microstructure play an important role in our understanding of pathologies such as osteoporosis, and in increasing our understanding of bone fracture and bone adaptation. Understanding of such behavior in bone is important for predicting and providing early treatment of fractures. The objective of this study is to present a numerical model for studying the initiation and accumulation of trabecular bone microdamage in both the pre- and post-yield regions. A sub-region of human vertebral trabecular bone was analyzed using a uniformly loaded anatomically accurate microstructural three-dimensional finite element model. The evolution of trabecular bone microdamage was governed using a non-linear, modulus reduction, perfect damage approach derived from a generalized plasticity stress-strain law. The model introduced in this paper establishes a history of microdamage evolution in both the pre- and post-yield regions

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Bone defects in revision knee arthroplasty are often located in load-bearing regions. The goal of this study was to determine whether a physiologic load could be used as an in situ osteogenic signal to the scaffolds filling the bone defects. In order to answer this question, we proposed a novel translation procedure having four steps: (1) determining the mechanical stimulus using finite element method, (2) designing an animal study to measure bone formation spatially and temporally using micro-CT imaging in the scaffold subjected to the estimated mechanical stimulus, (3) identifying bone formation parameters for the loaded and non-loaded cases appearing in a recently developed mathematical model for bone formation in the scaffold and (4) estimating the stiffness and the bone formation in the bone-scaffold construct. With this procedure, we estimated that after 3 years mechanical stimulation increases the bone volume fraction and the stiffness of scaffold by 1.5- and 2.7-fold, respectively, compared to a non-loaded situation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In population surveys of the exposure to medical X-rays both the frequency of examinations and the effective dose per examination are required. The use of the Swiss medical tariffication system (TARMED) for establishing the frequency of X-ray medical examinations was explored. The method was tested for radiography examinations performed in 2008 at the Lausanne University Hospital. The annual numbers of radiographies determined from the "TARMED" database are in good agreement with the figures extracted from the local RIS (Radiology Information System). The "TARMED" is a reliable and fast method for establishing the frequency of radiography examination, if we respect the context in which the "TARMED" code is used. In addition, this billing context provides most valuable information on the average number of radiographs per examination as well as the age and sex distributions. Radiographies represent the major part of X-ray examinations and are performed by about 4,000 practices and hospitals in Switzerland. Therefore this method has the potential to drastically simplify the organisation of nationwide surveys. There are still some difficulties to overcome if the method is to be used to assess the frequency of computed tomography or fluoroscopy examinations; procedures that deliver most of the radiation dose to the population. This is due to the poor specificity of "TARMED" codes concerning these modalities. However, the use of CT and fluoroscopy installations is easier to monitor using conventional survey methods since there are fewer centres. Ways to overcome the "TARMED" limitations for these two modalities are still being explored.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Abatacept (CTLA-Ig), a modulator of T-lymphocyte activation, has been approved by the Swiss health regulatory agency Swissmedic for the treatment of active rheumatoid arthritis (RA). This article summarises the key trial findings for this biologic agent in RA in different situations such as early erosive rheumatoid arthritis (RA), biologic-naïve RA, RA before and after the use of methotrexate or TNF-inhibitors and includes safety information from these trials. Based on these data, recommendations for clinical practice in Switzerland are made by a panel of experts.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: Coronary endothelial function is abnormal in patients with established coronary artery disease and was recently shown by MRI to relate to the severity of luminal stenosis. Recent advances in MRI now allow the noninvasive assessment of both anatomic and functional (endothelial function) changes that previously required invasive studies. We tested the hypothesis that abnormal coronary endothelial function is related to measures of early atherosclerosis such as increased coronary wall thickness. METHODS AND RESULTS: Seventeen arteries in 14 healthy adults and 17 arteries in 14 patients with nonobstructive coronary artery disease were studied. To measure endothelial function, coronary MRI was performed before and during isometric handgrip exercise, an endothelial-dependent stressor, and changes in coronary cross-sectional area and flow were measured. Black blood imaging was performed to quantify coronary wall thickness and indices of arterial remodeling. The mean stress-induced change in cross-sectional area was significantly higher in healthy adults (13.5%±12.8%, mean±SD, n=17) than in those with mildly diseased arteries (-2.2%±6.8%, P<0.0001, n=17). Mean coronary wall thickness was lower in healthy subjects (0.9±0.2 mm) than in patients with coronary artery disease (1.4±0.3 mm, P<0.0001). In contrast to healthy subjects, stress-induced changes in cross-sectional area, a measure of coronary endothelial function, correlated inversely with coronary wall thickness in patients with coronary artery disease (r=-0.73, P=0.0008). CONCLUSIONS: There is an inverse relationship between coronary endothelial function and local coronary wall thickness in patients with coronary artery disease but not in healthy adults. These findings demonstrate that local endothelial-dependent functional changes are related to the extent of early anatomic atherosclerosis in mildly diseased arteries. This combined MRI approach enables the anatomic and functional investigation of early coronary disease.