982 resultados para High specificity


Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: Nandrolone is an anabolic steroid widely used in several sports. The numerous nandrolone positive cases in the recent years (International Olympic Committee statistics) led to several studies in the antidoping field. Nevertheless, essential questions pertaining to nandrolone endogenous production, the effects of physical exercise on the excretion of nandrolone metabolites, and contamination from nutritional supplements must still be addressed. The purpose of this study was to evaluate the influence of exhaustive exercises on 19-norandrosterone (19-NA) and 19-noretiocholanolone (19-NE) urinary excretion rates after administration of labeled nandrolone. SETTING AND PARTICIPANTS: A total of 34 healthy male Caucasian volunteers from the Institute of Sports Sciences and Physical Education (University of Lausanne) applied to participate in the study. All subjects were free from any physical drug addiction and were instructed strictly to avoid any nutritional supplement or steroid before and during the study. The participants were randomly dispatched in 2 groups in a double-blind way: a placebo group and a group treated with C-labeled nandrolone. MAIN OUTCOME MEASUREMENTS: The urinary concentrations of the 2 main nandrolone metabolites, 19-NA and 19-NE, were measured using gas chromatography coupled with mass spectrometry. In addition, clinical parameters such as creatinine, total protein, and beta2-microglobuline levels were determined using immunologic assays. RESULTS: After an oral ingestion of a 25 mg 3,4-C2-nandrolone dose, followed by a second identical dose 24 hours later, 19-NA and 19-NE could be detected in the urine for a period of 6 days after the initial intake. Despite several interesting observations, the measurements were very scattered and did not appear to be significantly influenced by exercise sessions in the athlete population. CONCLUSIONS: The results of this study suggest that physical exercise cannot be considered as a reliable parameter that systematically affects nandrolone metabolite concentrations in the urine.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: Atherosclerosis results in a considerable medical and socioeconomic impact on society. We sought to evaluate novel magnetic resonance imaging (MRI) angiography and vessel wall sequences to visualize and quantify different morphologic stages of atherosclerosis in a Watanabe hereditary hyperlipidemic (WHHL) rabbit model. MATERIAL AND METHODS: Aortic 3D steady-state free precession angiography and subrenal aortic 3D black-blood fast spin-echo vessel wall imaging pre- and post-Gadolinium (Gd) was performed in 14 WHHL rabbits (3 normal, 6 high-cholesterol diet, and 5 high-cholesterol diet plus endothelial denudation) on a commercial 1.5 T MR system. Angiographic lumen diameter, vessel wall thickness, signal-/contrast-to-noise analysis, total vessel area, lumen area, and vessel wall area were analyzed semiautomatically. RESULTS: Pre-Gd, both lumen and wall dimensions (total vessel area, lumen area, vessel wall area) of group 2 + 3 were significantly increased when compared with those of group 1 (all P < 0.01). Group 3 animals had significantly thicker vessel walls than groups 1 and 2 (P < 0.01), whereas angiographic lumen diameter was comparable among all groups. Post-Gd, only diseased animals of groups 2 + 3 showed a significant (>100%) signal-to-noise ratio and contrast-to-noise increase. CONCLUSIONS: A combination of novel 3D magnetic resonance angiography and high-resolution 3D vessel wall MRI enabled quantitative characterization of various atherosclerotic stages including positive arterial remodeling and Gd uptake in a WHHL rabbit model using a commercially available 1.5 T MRI system.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

D-lactic acid in urine originates mainly from bacterial production in the intestinal tract. Increased D-lactate excretion as observed in patients affected by short bowel syndrome or necrotizing enterocolitis reflects D-lactic overproduction. Therefore, there is a need for a reliable and sensitive method able to detect D-lactic acid even at subclinical elevation levels. A new and highly sensitive method for the simultaneous determination of L- and D-lactic acid by a two-step procedure has been developed. This method is based on the concentration of lactic acid enantiomers from urine by supported liquid extraction followed by high-performance liquid chromatography-tandem mass spectrometry. The separation was achieved by the use of an Astec Chirobiotic? R chiral column under isocratic conditions. The calibration curves were linear over the ranges of 2-400 and 0.5-100 µmol/L respectively for L- and D-lactic acid. The limit of detection of D-lactic acid was 0.125 µmol/L and its limit of quantification was 0.5 µmol/L. The overall accuracy and precision were well within 10% of the nominal values. The developed method is suitable for production of reference values in children and could be applied for accurate routine analysis.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fluorescence imaging for detection of non-muscle-invasive bladder cancer is based on the selective production and accumulation of fluorescing porphyrins-mainly, protoporphyrin IX-in cancerous tissues after the instillation of Hexvix®. Although the sensitivity of this procedure is very good, its specificity is somewhat limited due to fluorescence false-positive sites. Consequently, magnification cystoscopy has been investigated in order to discriminate false from true fluorescence positive findings. Both white-light and fluorescence modes are possible with the magnification cystoscope, allowing observation of the bladder wall with magnification ranging between 30× for standard observation and 650×. The optical zooming setup allows adjusting the magnification continuously in situ. In the high-magnification (HM) regime, the smallest diameter of the field of view is 600 microns and the resolution is 2.5 microns when in contact with the bladder wall. With this cystoscope, we characterized the superficial vascularization of the fluorescing sites in order to discriminate cancerous from noncancerous tissues. This procedure allowed us to establish a classification based on observed vascular patterns. Seventy-two patients subject to Hexvix® fluorescence cystoscopy were included in the study. Comparison of HM cystoscopy classification with histopathology results confirmed 32/33 (97%) cancerous biopsies and rejected 17/20 (85%) noncancerous lesions.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We hypothesized that combining clinical risk factors (CRF) with the heel stiffness index (SI) measured via quantitative ultrasound (QUS) would improve the detection of women both at low and high risk for hip fracture. Categorizing women by risk score improved the specificity of detection to 42.4%, versus 33.8% using CRF alone and 38.4% using the SI alone. This combined CRF-SI score could be used wherever and whenever DXA is not readily accessible. INTRODUCTION AND HYPOTHESIS: Several strategies have been proposed to identify women at high risk for osteoporosis-related fractures; we wanted to investigate whether combining clinical risk factors (CRF) and heel QUS parameters could provide a more accurate tool to identify women at both low and high risk for hip fracture than either CRF or QUS alone. METHODS: We pooled two Caucasian cohorts, EPIDOS and SEMOF, into a large database named "EPISEM", in which 12,064 women, 70 to 100 years old, were analyzed. Amongst all the CRF available in EPISEM, we used only the ones which were statistically significant in a Cox multivariate model. Then, we constructed a risk score, by combining the QUS-derived heel stiffness index (SI) and the following seven CRF: patient age, body mass index (BMI), fracture history, fall history, diabetes history, chair-test results, and past estrogen treatment. RESULTS: Using the composite SI-CRF score, 42% of the women who did not report a hip fracture were found to be at low risk at baseline, and 57% of those who subsequently sustained a fracture were at high risk. Using the SI alone, corresponding percentages were 38% and 52%; using CRF alone, 34% and 53%. The number of subjects in the intermediate group was reduced from 5,400 (including 112 hip fractures) and 5,032 (including 111 hip fractures) to 4,549 (including 100 including fractures) for the CRF and QUS alone versus the combination score. CONCLUSIONS: Combining clinical risk factors to heel bone ultrasound appears to correctly identify more women at low risk for hip fracture than either the stiffness index or the CRF alone; it improves the detection of women both at low and high risk.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this investigation, high-resolution, 1x1x1-mm(3) functional magnetic resonance imaging (fMRI) at 7 T is performed using a multichannel array head coil and a surface coil approach. Scan geometry was optimized for each coil separately to exploit the strengths of both coils. Acquisitions with the surface coil focused on partial brain coverage, while whole-brain coverage fMRI experiments were performed with the array head coil. BOLD sensitivity in the occipital lobe was found to be higher with the surface coil than with the head array, suggesting that restriction of signal detection to the area of interest may be beneficial for localized activation studies. Performing independent component analysis (ICA) decomposition of the fMRI data, we consistently detected BOLD signal changes and resting state networks. In the surface coil data, a small negative BOLD response could be detected in these resting state network areas. Also in the data acquired with the surface coil, two distinct components of the positive BOLD signal were consistently observed. These two components were tentatively assigned to tissue and venous signal changes.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The capabilities of a high-resolution (HR), accurate mass spectrometer (Exactive-MS) operating in full scan MS mode was investigated for the quantitative LC/MS analysis of drugs in patients' plasma samples. A mass resolution of 50,000 (FWHM) at m/z 200 and a mass extracted window of 5 ppm around the theoretical m/z of each analyte were used to construct chromatograms for quantitation. The quantitative performance of the Exactive-MS was compared with that of a triple quadrupole mass spectrometer (TQ-MS), TSQ Quantum Discovery or Quantum Ultra, operating in the conventional selected reaction monitoring (SRM) mode. The study consisted of 17 therapeutic drugs including 8 antifungal agents (anidulafungin, caspofungin, fluconazole, itraconazole, hydroxyitraconazole posaconazole, voriconazole and voriconazole-N-oxide), 4 immunosuppressants (ciclosporine, everolimus, sirolimus and tacrolimus) and 5 protein kinase inhibitors (dasatinib, imatinib, nilotinib, sorafenib and sunitinib). The quantitative results obtained with HR-MS acquisition show comparable detection specificity, assay precision, accuracy, linearity and sensitivity to SRM acquisition. Importantly, HR-MS offers several benefits over TQ-MS technology: absence of SRM optimization, time saving when changing the analysis from one MS to another, more complete information of what is in the samples and easier troubleshooting. Our work demonstrates that U/HPLC coupled to Exactive HR-MS delivers comparable results to TQ-MS in routine quantitative drug analyses. Considering the advantages of HR-MS, these results suggest that, in the near future, there should be a shift in how routine quantitative analyses of small molecules, particularly for therapeutic drugs, are performed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In bottom-up proteomics, rapid and efficient protein digestion is crucial for data reliability. However, sample preparation remains one of the rate-limiting steps in proteomics workflows. In this study, we compared the conventional trypsin digestion procedure with two accelerated digestion protocols based on shorter reaction times and microwave-assisted digestion for the preparation of membrane-enriched protein fractions of the human pathogenic bacterium Staphylococcus aureus. Produced peptides were analyzed by Shotgun IPG-IEF, a methodology relying on separation of peptides by IPG-IEF before the conventional LC-MS/MS steps of shotgun proteomics. Data obtained on two LC-MS/MS platforms showed that accelerated digestion protocols, especially the one relying on microwave irradiation, enhanced the cleavage specificity of trypsin and thus improved the digestion efficiency especially for hydrophobic and membrane proteins. The combination of high-throughput proteomics with accelerated and efficient sample preparation should enhance the practicability of proteomics by reducing the time from sample collection to obtaining the results.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Contemporary coronary magnetic resonance angiography techniques suffer from signal-to-noise ratio (SNR) constraints. We propose a method to enhance SNR in gradient echo coronary magnetic resonance angiography by using sensitivity encoding (SENSE). While the use of sensitivity encoding to improve SNR seems counterintuitive, it can be exploited by reducing the number of radiofrequency excitations during the acquisition window while lowering the signal readout bandwidth, therefore improving the radiofrequency receive to radiofrequency transmit duty cycle. Under certain conditions, this leads to improved SNR. The use of sensitivity encoding for improved SNR in three-dimensional coronary magnetic resonance angiography is investigated using numerical simulations and an in vitro and an in vivo study. A maximum 55% SNR enhancement for coronary magnetic resonance angiography was found both in vitro and in vivo, which is well consistent with the numerical simulations. This method is most suitable for spoiled gradient echo coronary magnetic resonance angiography in which a high temporal and spatial resolution is required.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Ascertaining when and where genes are expressed is of crucial importance to understanding or predicting the physiological role of genes and proteins and how they interact to form the complex networks that underlie organ development and function. It is, therefore, crucial to determine on a genome-wide level, the spatio-temporal gene expression profiles at cellular resolution. This information is provided by colorimetric RNA in situ hybridization that can elucidate expression of genes in their native context and does so at cellular resolution. We generated what is to our knowledge the first genome-wide transcriptome atlas by RNA in situ hybridization of an entire mammalian organism, the developing mouse at embryonic day 14.5. This digital transcriptome atlas, the Eurexpress atlas (http://www.eurexpress.org), consists of a searchable database of annotated images that can be interactively viewed. We generated anatomy-based expression profiles for over 18,000 coding genes and over 400 microRNAs. We identified 1,002 tissue-specific genes that are a source of novel tissue-specific markers for 37 different anatomical structures. The quality and the resolution of the data revealed novel molecular domains for several developing structures, such as the telencephalon, a novel organization for the hypothalamus, and insight on the Wnt network involved in renal epithelial differentiation during kidney development. The digital transcriptome atlas is a powerful resource to determine co-expression of genes, to identify cell populations and lineages, and to identify functional associations between genes relevant to development and disease.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Phage display is a powerful method of isolating of antibody fragments from highly diverse naive human antibody repertoires. However, the affinity of the selected antibodies is usually low and current methods of affinity maturation are complex and time-consuming. In this paper, we describe an easy way to increase the functional affinity (avidity) of single chain variable fragments (scFvs) by tetramerization on streptavidin, following their site-specific biotinylation by the enzyme BirA. Expression vectors have been constructed that enable addition of the 15 amino acid biotin acceptor domain (BAD) on selected scFvs. Different domains were cloned at the C-terminus of scFv in the following order: a semi-rigid hinge region (of 16 residues), the BAD, and a histidine tail. Two such recombinant scFvs directed against the carcinoembryonic antigen (CEA) were previously selected from human non-immune and murine immune phage display libraries. The scFvs were first synthesized in Escherichia coli carrying the plasmid encoding the BirA enzyme, and then purified from the cytoplasmic extracts by Ni-NTA affinity chromatography. Purified biotinylated scFvs were tetramerized on the streptavidin molecule to create a streptabody (StAb). The avidity of various forms of anti-CEA StAbs, tested on purified CEA by competitive assays and surface plasmon resonance showed an increase of more than one log, as compared with the scFv monomer counterparts. Furthermore, the percentage of direct binding of 125I-labeled StAb or monomeric scFv on CEA-Sepharose beads and on CEA-expressing cells showed a dramatic increase for the tetramerized scFv (>80%), as compared with the monomeric scFv (<20%). Interestingly, the percentage binding of 125I-labeled anti-CEA StAbs to CEA-expressing colon carcinoma cells was definitely higher (>80%) than that obtained with a reference high affinity murine anti-CEA mAb (30%). Another advantage of using scFvs in a StAb format was demonstrated by Western blot analysis, where tetramerized anti-CEA scFv could detect a small quantity of CEA at a concentration 100-fold lower than the monomeric scFv.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PAH (N-(4-aminobenzoyl)glycin) clearance measurements have been used for 50 years in clinical research for the determination of renal plasma flow. The quantitation of PAH in plasma or urine is generally performed by colorimetric method after diazotation reaction but the measurements must be corrected for the unspecific residual response observed in blank plasma. We have developed a HPLC method to specifically determine PAH and its metabolite NAc-PAH using a gradient elution ion-pair reversed-phase chromatography with UV detection at 273 and 265 nm, respectively. The separations were performed at room temperature on a ChromCart (125 mmx4 mm I.D.) Nucleosil 100-5 microm C18AB cartridge column, using a gradient elution of MeOH-buffer pH 3.9 1:99-->15:85 over 15 min. The pH 3.9 buffered aqueous solution consisted in a mixture of 375 ml sodium citrate-citric acid solution (21.01 g citric acid and 8.0 g NaOH per liter), added up with 2.7 ml H3PO4 85%, 1.0 g of sodium heptanesulfonate and completed ad 1000 ml with ultrapure water. The N-acetyltransferase activity does not seem to notably affect PAH clearances, although NAc-PAH represents 10.2+/-2.7% of PAH excreted unchanged in 12 healthy subjects. The performance of the HPLC and the colorimetric method have been compared using urine and plasma samples collected from healthy volunteers. Good correlations (r=0.94 and 0.97, for plasma and urine, respectively) are found between the results obtained with both techniques. However, the colorimetric method gives higher concentrations of PAH in urine and lower concentrations in plasma than those determined by HPLC. Hence, both renal (ClR) and systemic (Cls) clearances are systematically higher (35.1 and 17.8%, respectively) with the colorimetric method. The fraction of PAH excreted by the kidney ClR/ClS calculated from HPLC data (n=143) is, as expected, always <1 (mean=0.73+/-0.11), whereas the colorimetric method gives a mean extraction ratio of 0.87+/-0.13 implying some unphysiological values (>1). In conclusion, HPLC not only enables the simultaneous quantitation of PAH and NAc-PAH, but may also provide more accurate and precise PAH clearance measurements.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Colorectal cancer (CRC) is the second leading cause of cancer-related death in developed countries. Early detection of CRC leads to decreased CRC mortality. A blood-based CRC screening test is highly desirable due to limited invasiveness and high acceptance rate among patients compared to currently used fecal occult blood testing and colonoscopy. Here we describe the discovery and validation of a 29-gene panel in peripheral blood mononuclear cells (PBMC) for the detection of CRC and adenomatous polyps (AP). Blood samples were prospectively collected from a multicenter, case-control clinical study. First, we profiled 93 samples with 667 candidate and 3 reference genes by high throughput real-time PCR (OpenArray system). After analysis, 160 genes were retained and tested again on 51 additional samples. Low expressed and unstable genes were discarded resulting in a final dataset of 144 samples profiled with 140 genes. To define which genes, alone or in combinations had the highest potential to discriminate AP and/or CRC from controls, data were analyzed by a combination of univariate and multivariate methods. A list of 29 potentially discriminant genes was compiled and evaluated for its predictive accuracy by penalized logistic regression and bootstrap. This method discriminated AP >1cm and CRC from controls with a sensitivity of 59% and 75%, respectively, with 91% specificity. The behavior of the 29-gene panel was validated with a LightCycler 480 real-time PCR platform, commonly adopted by clinical laboratories. In this work we identified a 29-gene panel expressed in PBMC that can be used for developing a novel minimally-invasive test for accurate detection of AP and CRC using a standard real-time PCR platform.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Two major sources of heterogeneity of mood disorders that have been demonstrated in clinical, family and genetic studies are the mood disorder subtype (i.e. bipolar (BPD) and major depressive disorder (MDD)) and age of onset of mood episodes. Using a prospective high-risk study design, our aims were to test the specificity of the parent-child transmission of BPD and MDD and to establish the risk of psychopathology in offspring in function of the age of onset of the parental disorder. METHODS: Clinical information was collected on 208 probands (n=81 with BPD, n=64 with MDD, n=63 medical controls) as well as their 202 spouses and 372 children aged 6-17 years at study entry. Parents and children were directly interviewed every 3 years (mean duration of follow-up=10.6 years). Parental age of onset was dichotomized at age 21. RESULTS: Offspring of parents with early onset BPD entailed a higher risk of BPD HR=7.9(1.8-34.6) and substance use disorders HR=5.0(1.1-21.9) than those with later onset and controls. Depressive disorders were not significantly increased in offspring regardless of parental mood disorder subtype or age of onset. LIMITATIONS: Limited sample size, age of onset in probands was obtained retrospectively, age of onset in co-parents was not adequately documented, and a quarter of the children had no direct interview. CONCLUSIONS: Our results provide support for the independence of familial aggregation of BPD from MDD and the heterogeneity of BPD based on patterns of onset. Future studies should further investigate correlates of early versus later onset BPD.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A rapid HPLC analytical method was developed and validated for the determination of the N-phenylpiperazine derivative LASSBio-579in plasma rat. Analyses were performed using a C18 column and elution with 20 mM sodium dihydrogen phosphate monohydrate - methanol. The analyte was monitored using a photodiode array detector (257 nm). Calibration curves in spiked plasma were linear over the concentration range of 0.3-8 mg/mL with determination coefficient > 0.99. The lower limit of quantification was 0.3 mg/mL. The applicability of the HPLC method for pharmacokinetic studies was tested using plasma samples obtained after administration of LASSBio-579 to Wistar rats, showing the specificity of the method.