985 resultados para High resolution tools
Resumo:
Increasing tungsten (W) use for industrial and military applications has resulted in greater W discharge into natural waters, soils and sediments. Risk modeling of W transport and fate in the environment relies on measurement of the release/mobilization flux of W in the bulk media and the interfaces between matrix compartments. Diffusive gradients in thin-films (DGT) is a promising passive sampling technique to acquire such information. DGT devices equipped with the newly developed high-resolution binding gels (precipitated zirconia, PZ, or ferrihydrite, PF, gels) or classic/conventional ferrihydrite slurry gel were comprehensively assessed for measuring W in waters. FerrihydriteDGT can measure W at various ionic strengths (0.001–0.5 mol L−1 NaNO3) and pH (4–8), while PZDGT can operate across slightly wider environmental conditions. The three DGT configurations gave comparable results for soil W measurement, showing that typically W resupply is relatively poorly sustained. 1D and 2D high-resolution W profiling across sediment—water and hotspot—bulk media interfaces from Lake Taihu were obtained using PZDGT coupled with laser ablation ICP–MS measurement, and the apparent diffusion fluxes across the interfaces were calculated using a numerical model.
Resumo:
O metano é um gás de estufa potente e uma importante fonte de energia. A importância global e impacto em zonas costeiras de acumulações e escape de gás metano são ainda pouco conhecidas. Esta tese investiga acumulações e escape de gás em canais de maré da Ria de Aveiro com dados de cinco campanhas de reflexão sísmica de alta resolução realizadas em 1986, 1999, 2002 e 2003. Estas incluem três campanhas de Chirp (RIAV99, RIAV02 e RIAV02A) e duas campanhas de Boomer (VOUGA86 e RIAV03). O processamento dos dados de navegação incluíram filtros de erros, correcções de sincronização de relógios de sistemas de aquisição de dados, ajuste de “layback” e estimativa da posição de “midpoint”. O processamento do sinal sísmico consistiu na correcção das amplitudes, remoção de ruído do tipo “burst”, correcções estáticas, correcção do “normal move-out”, filtragem passabanda, desconvolução da assinatura e migração Stolt F-K. A análise da regularidade do trajecto de navegação, dos desfasamentos entre horizontes e dos modelos de superfícies foi utilizada para controlo de qualidade, e permitiu a revisão e melhoria dos parâmetros de processamento. A heterogeneidade da cobertura sísmica, da qualidade do sinal, da penetração e da resolução, no seu conjunto constrangeram o uso dos dados a interpretações detalhadas, mas locais, de objectos geológicos da Ria. É apresentado um procedimento para determinar a escolha de escalas adequadas para modelar os objectos geológicos, baseado na resolução sísmica, erros de posicionamento conhecidos e desfasamentos médios entre horizontes. As evidências de acumulação e escape de gás na Ria de Aveiro incluem turbidez acústica, reflexões reforçadas, cortinas acústicas, domas, “pockmarks” e alinhamentos de “pockmarks” enterradas, horizontes perturbados e plumas acústicas na coluna de água (flares). A estratigrafia e a estrutura geológica controlam a distribuição e extensão das acumulações e escape de gás. Ainda assim, nestes sistemas de baixa profundidade de água, as variações da altura de maré têm um impacto significativo na detecção de gás com métodos acústicos, através de alterações nas amplitudes originais de reflexões reforçadas, turbidez acústica e branqueamento acústico em zonas com gás. Os padrões encontrados confirmam que o escape de bolhas de gás é desencadeado pela descida da maré. Há acumulações de gás em sedimentos Holocénicos e no substrato de argilas e calcários do Mesozóico. Evidências directas de escape de gás em sondagens em zonas vizinhas, mostraram gás essencialmente biogénico. A maioria do gás na área deve ter sido gerado em sedimentos lagunares Holocénicos. No entanto, a localização e geometria de estruturas de escape de fluidos em alguns canais de maré, seguem o padrão de fracturas do substrato Mesozóico, indicando uma possível fonte mais profunda de gás e que estas fracturas funcionam como condutas preferenciais de migração dos fluidos e exercem um controlo estrutural na ocorrência de gás na Ria.
Resumo:
The development of a compact gamma camera with high spatial resolution is of great interest in Nuclear Medicine as a means to increase the sensitivity of scintigraphy exams and thus allow the early detection of small tumours. Following the introduction of the wavelength-shifting fibre (WSF) gamma camera by Soares et al. and evolution of photodiodes into highly sensitive silicon photomultipliers (SiPMs), this thesis explores the development of a WSF gamma camera using SiPMs to obtain the position information of scintillation events in a continuous CsI(Na) crystal. The design is highly flexible, allowing the coverage of different areas and the development of compact cameras, with very small dead areas at the edges. After initial studies which confirmed the feasibility of applying SiPMs, a prototype with 5 5 cm2 was assembled and tested at room temperature, in an active field-of-view of 10 10 mm2. Calibration and characterisation of intrinsic properties of this prototype were done using 57Co, while extrinsic measurements were performed using a high-resolution parallel-hole collimator and 99mTc. In addition, a small mouse injected with a radiopharmaceutical was imaged with the developed prototype. Results confirm the great potential of SiPMs when applied in a WSF gamma camera, achieving spatial resolution performance superior to the traditional Anger camera. Furthermore, performance can be improved by an optimisation of experimental conditions, in order to minimise and control the undesirable effects of thermal noise and non-uniformity of response of multiple SiPMs. The development and partial characterisation of a larger SiPM WSF gamma camera with 10 10 cm2 for clinical application are also presented.
Resumo:
A procedure for the determination of seven indicator PCBs in soils and sediments using microwave-assisted extraction (MAE) and headspace solid-phase microextraction (HS-SPME) prior to GC-MS/MS is described. Optimization of the HS-SPME was carried out for the most important parameters such as extraction time, sample volume and temperature. The adopted methodology has reduced consumption of organic solvents and analysis runtime. Under the optimized conditions, the method detection limit ranged from 0.6 to 1 ng/g when 5 g of sample was extracted, the precision on real samples ranged from 4 to 21% and the recovery from 69 to 104%. The proposed method, which included the analysis of a certified reference material in its validation procedure, can be extended to several other PCBs and used in the monitoring of soil or sediments for the presence of PCBs.
Resumo:
Coastal low-level jets (CLLJ) are a low-tropospheric wind feature driven by the pressure gradient produced by a sharp contrast between high temperatures over land and lower temperatures over the sea. This contrast between the cold ocean and the warm land in the summer is intensified by the impact of the coastal parallel winds on the ocean generating upwelling currents, sharpening the temperature gradient close to the coast and giving rise to strong baroclinic structures at the coast. During summertime, the Iberian Peninsula is often under the effect of the Azores High and of a thermal low pressure system inland, leading to a seasonal wind, in the west coast, called the Nortada (northerly wind). This study presents a regional climatology of the CLLJ off the west coast of the Iberian Peninsula, based on a 9km resolution downscaling dataset, produced using the Weather Research and Forecasting (WRF) mesoscale model, forced by 19 years of ERA-Interim reanalysis (1989-2007). The simulation results show that the jet hourly frequency of occurrence in the summer is above 30% and decreases to about 10% during spring and autumn. The monthly frequencies of occurrence can reach higher values, around 40% in summer months, and reveal large inter-annual variability in all three seasons. In the summer, at a daily base, the CLLJ is present in almost 70% of the days. The CLLJ wind direction is mostly from north-northeasterly and occurs more persistently in three areas where the interaction of the jet flow with local capes and headlands is more pronounced. The coastal jets in this area occur at heights between 300 and 400 m, and its speed has a mean around 15 m/s, reaching maximum speeds of 25 m/s.
Resumo:
Correlation between facies associations (marine, estuarine and distal fluviatile environments) and disconformities, observed between Foz da Fonte (SW of Setúbal Peninsula) and Santa Iria da Azóia (NE of Lisbon) are presented. The precise definition of the marine-continental facies relationships improved very much the chronology of the depositional sequence boundaries. Tectonic and eustatic controls are discussed on the basis of subsidence rates variation.
Resumo:
Gamma radiations measurements were carried out in the vicinity of a coal-fired power plant located in the southwest coastline of Portugal. Two different gamma detectors were used to assess the environmental radiation within a circular area of 20 km centred in the coal plant: a scintillometer (SPP2 NF, Saphymo) and a high purity germanium detector (HPGe, Canberra). Fifty urban and suburban measurements locations were established within the defined area and two measurements campaigns were carried out. The results of the total gamma radiation ranged from 20.83 to 98.33 counts per second (c.p.s.) for both measurement campaigns and outdoor doses rates ranged from 77.65 to 366.51 Gy/h. Natural emitting nuclides from the U-238 and Th-232 decay series were identified as well as the natural emitting nuclide K-40. The radionuclide concentration from the uranium and thorium series determined by gamma spectrometry ranged from 0.93 to 73.68 Bq/kg, while for K-40 the concentration ranged from 84.14 to 904.38 Bq/kg. The obtained results were used primarily to define the variability in measured environmental radiation and to determine the coal plant’s influence in the measured radiation levels. The highest values were measured at two locations near the power plant and at locations between the distance of 6 and 20 km away from the stacks, mainly in the prevailing wind direction. The results showed an increase or at least an influence from the coal-fired plant operations, both qualitatively and quantitatively.
Resumo:
OBJECTIVE-We studied whether manganese-enhanced high-field magnetic resonance (MR) imaging (MEHFMRI) could quantitatively detect individual islets in situ and in vivo and evaluate changes in a model of experimental diabetes.RESEARCH DESIGN AND METHODS-Whole pancreata from untreated (n = 3), MnCl(2) and glucose-injected mice (n = 6), and mice injected with either streptozotocin (STZ; n = 4) or citrate buffer (n = 4) were imaged ex vivo for unambiguous evaluation of islets. Exteriorized pancreata of MnCl(2) and glucose-injected mice (n = 6) were imaged in vivo to directly visualize the gland and minimize movements. In all cases, MR images were acquired in a 14.1 Testa scanner and correlated with the corresponding (immuno)histological sections.RESULTS-In ex vivo experiments, MEHFMRI distinguished different pancreatic tissues and evaluated the relative abundance of islets in the pancreata of normoglycemic mice. MEHFMRI also detected a significant decrease in the numerical and volume density of islets in STZ-injected mice. However, in the latter measurements the loss of beta-cells was undervalued under the conditions tested. The experiments on the externalized pancreata confirmed that MEHFMRI could visualize native individual islets in living, anesthetized mice.CONCLUSIONS-Data show that MEHFMRI quantitatively visualizes individual islets in the intact mouse pancreas, both ex vivo and in vivo. Diabetes 60:2853-2860, 2011
Resumo:
After ischemic stroke, the ischemic damage to brain tissue evolves over time and with an uneven spatial distribution. Early irreversible changes occur in the ischemic core, whereas, in the penumbra, which receives more collateral blood flow, the damage is more mild and delayed. A better characterization of the penumbra, irreversibly damaged and healthy tissues is needed to understand the mechanisms involved in tissue death. MRSI is a powerful tool for this task if the scan time can be decreased whilst maintaining high sensitivity. Therefore, we made improvements to a (1) H MRSI protocol to study middle cerebral artery occlusion in mice. The spatial distribution of changes in the neurochemical profile was investigated, with an effective spatial resolution of 1.4 μL, applying the protocol on a 14.1-T magnet. The acquired maps included the difficult-to-separate glutamate and glutamine resonances and, to our knowledge, the first mapping of metabolites γ-aminobutyric acid and glutathione in vivo, within a metabolite measurement time of 45 min. The maps were in excellent agreement with findings from single-voxel spectroscopy and offer spatial information at a scan time acceptable for most animal models. The metabolites measured differed with respect to the temporal evolution of their concentrations and the localization of these changes. Specifically, lactate and N-acetylaspartate concentration changes largely overlapped with the T(2) -hyperintense region visualized with MRI, whereas changes in cholines and glutathione affected the entire middle cerebral artery territory. Glutamine maps showed elevated levels in the ischemic striatum until 8 h after reperfusion, and until 24 h in cortical tissue, indicating differences in excitotoxic effects and secondary energy failure in these tissue types. Copyright © 2011 John Wiley & Sons, Ltd.
Resumo:
The goal of this study was to investigate the performance of 3D synchrotron differential phase contrast (DPC) imaging for the visualization of both macroscopic and microscopic aspects of atherosclerosis in the mouse vasculature ex vivo. The hearts and aortas of 2 atherosclerotic and 2 wild-type control mice were scanned with DPC imaging with an isotropic resolution of 15 μm. The coronary artery vessel walls were segmented in the DPC datasets to assess their thickness, and histological staining was performed at the level of atherosclerotic plaques. The DPC imaging allowed for the visualization of complex structures such as the coronary arteries and their branches, the thin fibrous cap of atherosclerotic plaques as well as the chordae tendineae. The coronary vessel wall thickness ranged from 37.4 ± 5.6 μm in proximal coronary arteries to 13.6 ± 3.3 μm in distal branches. No consistent differences in coronary vessel wall thickness were detected between the wild-type and atherosclerotic hearts in this proof-of-concept study, although the standard deviation in the atherosclerotic mice was higher in most segments, consistent with the observation of occasional focal vessel wall thickening. Overall, DPC imaging of the cardiovascular system of the mice allowed for a simultaneous detailed 3D morphological assessment of both large structures and microscopic details.
Resumo:
L’accident vasculaire cérébral (AVC) est une cause principale de décès et de morbidité dans le monde; une bonne partie des AVC est causée par la plaque d’athérosclérose carotidienne. La prévention de l’AVC chez les patients ayant une plaque carotidienne demeure controversée, vu les risques et bénéfices ambigus associés au traitement chirurgical ou médical. Plusieurs méthodes d’imagerie ont été développées afin d’étudier la plaque vulnérable (dont le risque est élevé), mais aucune n’est suffisamment validée ou accessible pour permettre une utilisation comme outil de dépistage. L’élastographie non-invasive vasculaire (NIVE) est une technique nouvelle qui cartographie les déformations (élasticité) de la plaque afin de détecter les plaque vulnérables; cette technique n’est pas encore validée cliniquement. Le but de ce projet est d’évaluer la capacité de NIVE de caractériser la composition de la plaque et sa vulnérabilité in vivo chez des patients ayant des plaques sévères carotidiennes, en utilisant comme étalon de référence, l’imagerie par résonance magnétique (IRM) à haute-résolution. Afin de poursuivre cette étude, une connaissance accrue de l’AVC, l’athérosclérose, la plaque vulnérable, ainsi que des techniques actuelles d’imagerie de la plaque carotidienne, est requise. Trente-et-un sujets ont été examinés par NIVE par ultrasonographie et IRM à haute-résolution. Sur 31 plaques, 9 étaient symptomatiques, 17 contenaient des lipides, et 7 étaient vulnérables selon l’IRM. Les déformations étaient significativement plus petites chez les plaques contenant des lipides, avec une sensibilité élevée et une spécificité modérée. Une association quadratique entre la déformation et la quantité de lipide a été trouvée. Les déformations ne pouvaient pas distinguer les plaques vulnérables ou symptomatiques. En conclusion, NIVE par ultrasonographie est faisable chez des patients ayant des sténoses carotidiennes significatives et peut détecter la présence d’un coeur lipidique. Des études supplémentaires de progression de la plaque avec NIVE sont requises afin d’identifier les plaques vulnérables.
Resumo:
Contexte & Objectifs : La manométrie perfusée conventionnelle et la manométrie haute résolution (HRM) ont permis le développement d’une variété de paramètres pour mieux comprendre la motilité de l'œsophage et quantifier les caractéristiques de la jonction œsophago-gastrique (JOG). Cependant, l'anatomie de la JOG est complexe et les enregistrements de manométrie détectent à la fois la pression des structures intrinsèques et des structures extrinsèques à l'œsophage. Ces différents composants ont des rôles distincts au niveau de la JOG. Les pressions dominantes ainsi détectées au niveau de la JOG sont attribuables au sphincter œsophagien inférieur (SOI) et aux piliers du diaphragme (CD), mais aucune des technologies manométriques actuelles n’est capable de distinguer ces différents composants de la JOG. Lorsqu’on analyse les caractéristiques de la JOG au repos, celle ci se comporte avant tout comme une barrière antireflux. Les paramètres manométriques les plus couramment utilisés dans ce but sont la longueur de la JOG et le point d’inversion respiratoire (RIP), défini comme le lieu où le pic de la courbe de pression inspiratoire change de positif (dans l’abdomen) à négatif (dans le thorax), lors de la classique manœuvre de « pull-through ». Cependant, l'importance de ces mesures reste marginale comme en témoigne une récente prise de position de l’American Gastroenterology Association Institute (AGAI) (1) qui concluait que « le rôle actuel de la manométrie dans le reflux gastro-œsophagien (RGO) est d'exclure les troubles moteurs comme cause des symptômes présentés par la patient ». Lors de la déglutition, la mesure objective de la relaxation de la JOG est la pression de relaxation intégrée (IRP), qui permet de faire la distinction entre une relaxation normale et une relaxation anormale de la JOG. Toutefois, puisque la HRM utilise des pressions moyennes à chaque niveau de capteurs, certaines études de manométrie laissent suggérer qu’il existe une zone de haute pression persistante au niveau de la JOG même si un transit est mis en évidence en vidéofluoroscopie. Récemment, la manométrie haute résolution « 3D » (3D-HRM) a été développée (Given Imaging, Duluth, GA) avec le potentiel de simplifier l'évaluation de la morphologie et de la physiologie de la JOG. Le segment « 3D » de ce cathéter de HRM permet l'enregistrement de la pression à la fois de façon axiale et radiale tout en maintenant une position fixe de la sonde, et évitant ainsi la manœuvre de « pull-through ». Par conséquent, la 3D-HRM devrait permettre la mesure de paramètres importants de la JOG tels que sa longueur et le RIP. Les données extraites de l'enregistrement fait par 3D-HRM permettraient également de différencier les signaux de pression attribuables au SOI des éléments qui l’entourent. De plus, l’enregistrement des pressions de façon radiaire permettrait d’enregistrer la pression minimale de chaque niveau de capteurs et devrait corriger cette zone de haute pression parfois persistante lors la déglutition. Ainsi, les objectifs de ce travail étaient: 1) de décrire la morphologie de la JOG au repos en tant que barrière antireflux, en comparant les mesures effectuées avec la 3D-HRM en temps réel, par rapport à celle simulées lors d’une manœuvre de « pull-through » et de déterminer quelles sont les signatures des pressions attribuables au SOI et au diaphragme; 2) d’évaluer la relaxation de la JOG pendant la déglutition en testant l'hypothèse selon laquelle la 3D-HRM permet le développement d’un nouveau paradigme (appelé « 3D eSleeve ») pour le calcul de l’IRP, fondé sur l’utilisation de la pression radiale minimale à chaque niveau de capteur de pression le long de la JOG. Ce nouveau paradigme sera comparé à une étude de transit en vidéofluoroscopie pour évaluer le gradient de pression à travers la JOG. Méthodes : Nous avons utilisé un cathéter 3D-HRM, qui incorpore un segment dit « 3D » de 9 cm au sein d’un cathéter HRM par ailleurs standard. Le segment 3D est composé de 12 niveaux (espacés de 7.5mm) de 8 capteurs de pression disposés radialement, soit un total de 96 capteurs. Neuf volontaires ont été étudiés au repos, où des enregistrements ont été effectués en temps réel et pendant une manœuvre de « pull-through » du segment 3D (mobilisation successive du cathéter de 5 mm, pour que le segment 3D se déplace le long de la JOG). Les mesures de la longueur du SOI et la détermination du RIP ont été réalisées. La longueur de la JOG a été mesurée lors du « pull-through » en utilisant 4 capteurs du segment 3D dispersés radialement et les marges de la JOG ont été définies par une augmentation de la pression de 2 mmHg par rapport à la pression gastrique ou de l’œsophage. Pour le calcul en temps réel, les limites distale et proximale de la JOG ont été définies par une augmentation de pression circonférentielle de 2 mmHg par rapport à la pression de l'estomac. Le RIP a été déterminée, A) dans le mode de tracé conventionnel avec la méthode du « pull-through » [le RIP est la valeur moyenne de 4 mesures] et B) en position fixe, dans le mode de représentation topographique de la pression de l’œsophage, en utilisant l’outil logiciel pour déterminer le point d'inversion de la pression (PIP). Pour l'étude de la relaxation de la JOG lors de la déglutition, 25 volontaires ont été étudiés et ont subi 3 études de manométrie (10 déglutitions de 5ml d’eau) en position couchée avec un cathéter HRM standard et un cathéter 3D-HRM. Avec la 3D-HRM, l’analyse a été effectuée une fois avec le segment 3D et une fois avec une partie non 3D du cathéter (capteurs standard de HRM). Ainsi, pour chaque individu, l'IRP a été calculée de quatre façons: 1) avec la méthode conventionnelle en utilisant le cathéter HRM standard, 2) avec la méthode conventionnelle en utilisant le segment standard du cathéter 3D-HRM, 3) avec la méthode conventionnelle en utilisant le segment « 3D » du cathéter 3D-HRM, et 4) avec le nouveau paradigme (3D eSleeve) qui recueille la pression minimale de chaque niveau de capteurs (segment 3D). Quatorze autres sujets ont subi une vidéofluoroscopie simultanée à l’étude de manométrie avec le cathéter 3D-HRM. Les données de pression ont été exportés vers MATLAB ™ et quatre pressions ont été mesurées simultanément : 1) la pression du corps de l’œsophage, 2cm au-dessus de la JOG, 2) la pression intragastrique, 3) la pression radiale moyenne de la JOG (pression du eSleeve) et 4) la pression de la JOG en utilisant la pression minimale de chaque niveau de capteurs (pression du 3D eSleeve). Ces données ont permis de déterminer le temps permissif d'écoulement du bolus (FPT), caractérisé par la période au cours de laquelle un gradient de pression existe à travers la JOG (pression œsophagienne > pression de relaxation de la JOG > pression gastrique). La présence ou l'absence du bolus en vidéofluoroscopie et le FPT ont été codés avec des valeurs dichotomiques pour chaque période de 0,1 s. Nous avons alors calculé la sensibilité et la spécificité correspondant à la valeur du FPT pour la pression du eSleeve et pour la pression du 3D eSleeve, avec la vidéofluoroscopie pour référence. Résultats : Les enregistrements avec la 3D-HRM laissent suggérer que la longueur du sphincter évaluée avec la méthode du « pull-through » était grandement exagéré en incorporant dans la mesure du SOI les signaux de pression extrinsèques à l’œsophage, asymétriques et attribuables aux piliers du diaphragme et aux structures vasculaires. L’enregistrement en temps réel a permis de constater que les principaux constituants de la pression de la JOG au repos étaient attribuables au diaphragme. L’IRP calculé avec le nouveau paradigme 3D eSleeve était significativement inférieur à tous les autres calculs d'IRP avec une limite supérieure de la normale de 12 mmHg contre 17 mmHg pour l’IRP calculé avec la HRM standard. La sensibilité (0,78) et la spécificité (0,88) du 3D eSleeve étaient meilleurs que le eSleeve standard (0,55 et 0,85 respectivement) pour prédire le FPT par rapport à la vidéofluoroscopie. Discussion et conclusion : Nos observations suggèrent que la 3D-HRM permet l'enregistrement en temps réel des attributs de la JOG, facilitant l'analyse des constituants responsables de sa fonction au repos en tant que barrière antireflux. La résolution spatiale axiale et radiale du segment « 3D » pourrait permettre de poursuivre cette étude pour quantifier les signaux de pression de la JOG attribuable au SOI et aux structures extrinsèques (diaphragme et artéfacts vasculaires). Ces attributs du cathéter 3D-HRM suggèrent qu'il s'agit d'un nouvel outil prometteur pour l'étude de la physiopathologie du RGO. Au cours de la déglutition, nous avons évalué la faisabilité d’améliorer la mesure de l’IRP en utilisant ce nouveau cathéter de manométrie 3D avec un nouveau paradigme (3D eSleeve) basé sur l’utilisation de la pression radiale minimale à chaque niveau de capteurs de pression. Nos résultats suggèrent que cette approche est plus précise que celle de la manométrie haute résolution standard. La 3D-HRM devrait certainement améliorer la précision des mesures de relaxation de la JOG et cela devrait avoir un impact sur la recherche pour modéliser la JOG au cours de la déglutition et dans le RGO.
Resumo:
Triple quadrupole mass spectrometers coupled with high performance liquid chromatography are workhorses in quantitative bioanalyses. It provides substantial benefits including reproducibility, sensitivity and selectivity for trace analysis. Selected Reaction Monitoring allows targeted assay development but data sets generated contain very limited information. Data mining and analysis of non-targeted high-resolution mass spectrometry profiles of biological samples offer the opportunity to perform more exhaustive assessments, including quantitative and qualitative analysis. The objectives of this study was to test method precision and accuracy, statistically compare bupivacaine drug concentration in real study samples and verify if high resolution and accurate mass data collected in scan mode can actually permit retrospective data analysis, more specifically, extract metabolite related information. The precision and accuracy data presented using both instruments provided equivalent results. Overall, the accuracy was ranging from 106.2 to 113.2% and the precision observed was from 1.0 to 3.7%. Statistical comparisons using a linear regression between both methods reveal a coefficient of determination (R2) of 0.9996 and a slope of 1.02 demonstrating a very strong correlation between both methods. Individual sample comparison showed differences from -4.5% to 1.6% well within the accepted analytical error. Moreover, post acquisition extracted ion chromatograms at m/z 233.1648 ± 5 ppm (M-56) and m/z 305.2224 ± 5 ppm (M+16) revealed the presence of desbutyl-bupivacaine and three distinct hydroxylated bupivacaine metabolites. Post acquisition analysis allowed us to produce semiquantitative evaluations of the concentration-time profiles for bupicavaine metabolites.