747 resultados para Helen Kelsh
Abnormalities of sodium excretion and other disorders of renal function in fulminant hepatic failure
Resumo:
Renal function was evaluated in 40 patients with fulminant hepatic failure, They were divided into two groups on the basis of glomerular filtration rates greater than 40 ml/min or less than 25 ml/min. A number of patients in group 1 had markedly abnormal renal retention of sodium together with a reduced free water clearance and low potassium excretion which could be explained by increased proximal tubular reabsorption of sodium. The patients in group 2 had evidence that renal tubular integrity was maintained when the glomerular filtration rate was greater than or equal ml/min (functional renal failure), but evidence of tubular damage was present when this was less than 3 ml/min (acute tubular necrosis).
Resumo:
Macrophage migration inhibitory factor (MIF) is an abundantly expressed proinflammatory cytokine playing a critical role in innate immunity and sepsis and other inflammatory diseases. We examined whether functional MIF gene polymorphisms (-794 CATT(5-8) microsatellite and -173 G/C SNP) were associated with the occurrence and outcome of meningococcal disease in children. The CATT(5) allele was associated with the probability of death predicted by the Pediatric Index of Mortality 2 (P=0.001), which increased in correlation with the CATT(5) copy number (P=0.04). The CATT(5) allele, but not the -173 G/C alleles, was also associated with the actual mortality from meningoccal sepsis [OR 2.72 (1.2-6.4), P=0.02]. A family-based association test (i.e., transmission disequilibrium test) performed in 240 trios with 1 afflicted offspring indicated that CATT(5) was a protective allele (P=0.02) for the occurrence of meningococcal disease. At baseline and after stimulation with Neisseria meningitidis in THP-1 monocytic cells or in a whole-blood assay, CATT(5) was found to be a low-expression MIF allele (P=0.005 and P=0.04 for transcriptional activity; P=0.09 and P=0.09 for MIF production). Taken together, these data suggest that polymorphisms of the MIF gene affecting MIF expression are associated with the occurrence, severity, and outcome of meningococcal disease in children.
Resumo:
Resumo: O objetivo deste trabalho foi quantificar o efeito do tipo de diesel e da concentração de biodiesel na mistura combustível sobre as emissões de gases por motor agrícola submetido a diferentes cargas. Foram testados dois tipos de diesel: S10, com baixo teor de enxofre; e S500, com alto teor de enxofre; bem como suas misturas com 5, 10, 15, 20, 50 e 100% de biodiesel. O motor, de quatro cilindros, turboalimentado e com 105 cv de potência máxima, foi submetido a oito modos de operação, sob diferentes rotações e torques. O ensaio seguiu a metodologia prevista na norma NBR ISSO 8174-4:2012, tendo-se analisado as emissões de O2, CO2, NO2, NO, CO e de hidrocarbonetos (HC). Somente as emissões de HC foram influenciadas pelo tipo de diesel utilizado. As emissões de NO2 e O2 aumentaram com o aumento da concentração de biodiesel na mistura, enquanto as emissões de CO2, NO, CO e HC diminuíram. A carga aplicada ao motor esteve diretamente relacionada às emissões, exceto para O2. O combustível S10, com 20% de biodiesel, reduz as emissões, em comparação ao diesel comercial (S500), sem perda no desempenho do motor.
Resumo:
BACKGROUND: Used in conjunction with biological surveillance, behavioural surveillance provides data allowing for a more precise definition of HIV/STI prevention strategies. In 2008, mapping of behavioural surveillance in EU/EFTA countries was performed on behalf of the European Centre for Disease prevention and Control. METHOD: Nine questionnaires were sent to all 31 member States and EEE/EFTA countries requesting data on the overall behavioural and second generation surveillance system and on surveillance in the general population, youth, men having sex with men (MSM), injecting drug users (IDU), sex workers (SW), migrants, people living with HIV/AIDS (PLWHA), and sexually transmitted infection (STI) clinics patients. Requested data included information on system organisation (e.g. sustainability, funding, institutionalisation), topics covered in surveys and main indicators. RESULTS: Twenty-eight of the 31 countries contacted supplied data. Sixteen countries reported an established behavioural surveillance system, and 13 a second generation surveillance system (combination of biological surveillance of HIV/AIDS and STI with behavioural surveillance). There were wide differences as regards the year of survey initiation, number of populations surveyed, data collection methods used, organisation of surveillance and coordination with biological surveillance. The populations most regularly surveyed are the general population, youth, MSM and IDU. SW, patients of STI clinics and PLWHA are surveyed less regularly and in only a small number of countries, and few countries have undertaken behavioural surveys among migrant or ethnic minorities populations. In many cases, the identification of populations with risk behaviour and the selection of populations to be included in a BS system have not been formally conducted, or are incomplete. Topics most frequently covered are similar across countries, although many different indicators are used. In most countries, sustainability of surveillance systems is not assured. CONCLUSION: Although many European countries have established behavioural surveillance systems, there is little harmonisation as regards the methods and indicators adopted. The main challenge now faced is to build and maintain organised and functional behavioural and second generation surveillance systems across Europe, to increase collaboration, to promote robust, sustainable and cost-effective data collection methods, and to harmonise indicators.
Resumo:
A produção de mudas de fruteiras nativas é um importante passo para a preservação das espécies, exploração comercial sustentável e geração de emprego. Neste contexto, os fertilizantes alternativos, como pó de rocha, propiciam a obtenção de um substrato com maior fertilidade, rico em nutrientes, com redução de custos em mão de obra e com a reposição de adubação. O objetivo no presente trabalho foi avaliar o desenvolvimento inicial de mudas de camu-camu (Myrciaria dubia H.B.K. McVaugh) em função de doses de pó de basalto. O experimento foi conduzido em casa de vegetação pertencente ao CCA/UFRR. O delineamento experimental foi o de blocos ao acaso, com cinco repetições, em esquema fatorial (5x2+1), sendo seis doses de pó de basalto (0; 0,42;1,04; 2,08; 4,17 e 8,33 g kg-1), duas granulometrias (0,05 e 0,10 mm f) e uma testemunha. Vasos de polietileno de 14 litros foram as unidades experimentais e utilizou-se um Latossolo Amarelo distrófico textura média. A incubação do solo nos vasos teve duração de 120 dias e, após esse período, fez-se o transplante das plântulas. Após seis meses do plantio, foram determinados altura, diâmetro do colo, número de ramos e biomassa seca da parte aérea e de raiz das mudas. A partir destes dados, foram calculados os índices morfológicos. Os tratamentos sem pó de basalto (0 g kg-1) e a dose de 0,42 g kg-1 produziram mudas de menor qualidade em ambas as granulometrias testadas. As melhores mudas de camu-camu foram obtidas aplicando-se 4,17 e 8,33 g kg-1 de pó de basalto com a granulometria de 0,05 mm.
Resumo:
This volume of the IARC Monographs provides evaluations of the carcinogenicity of polychlorinated biphenyls and polybrominated biphenyls. Polychlorinated biphenyls are a class of aromatic compounds comprising 209 congeners, each containing 1 to 10 chlorine atoms attached to a biphenyl nucleus. Technical products, which were manufactured to obtain a certain degree of chlorination, are mixtures of numerous congeners. These products were widely used as dielectric fluid in capacitors and transformers, and to a lesser extent in building materials. Although their production and use has been banned in most countries, these compounds are ubiquitous environmental pollutants, including in polar regions and the deep ocean, because they are persistent and bioaccumulate. Worldwide monitoring programmes have shown that polychlorinated biphenyls are present in most samples of human milk. An IARC Monographs Working Group reviewed epidemiological evidence, animal bioassays, and mechanistic and other relevant data to reach conclusions as to the carcinogenic hazard to humans of polychlorinated biphenyls, of the subclass of dioxinlike polychlorinated biphenyls, and of polybrominated biphenyls.
Resumo:
OBJETIVO: Este trabalho tem como objetivo discutir os efeitos dos principais parâmetros que interferem na qualidade da imagem e na dose de entrada na pele do paciente. MATERIAIS E MÉTODOS: Foram acompanhadas radiografias pediátricas de tórax em três instituições. Em cada uma delas foram feitos testes de desempenho dos equipamentos de raios-X utilizados. A avaliação da dose de entrada na pele foi feita com a utilização de dosímetros termoluminescentes. RESULTADOS: Apenas um dos equipamentos de raios-X testados mostrou-se em condições aceitáveis de funcionamento. Os valores médios de dose de entrada na pele para os exames investigados, em função da faixa etária, foram: (0,222 ± 0,088) mGy para menores de 1 ano, (0,28 ± 0,11) mGy entre 1,1 e 4 anos, (0,26 ± 0,13) mGy entre 4,1 e 6 anos, (0,23 ± 0,13) mGy entre 6,1 e 10 anos e (0,26 ± 0,25) mGy para maiores de 10 anos. CONCLUSÃO: Os valores médios de dose de entrada na pele são bastante elevados se comparados aos níveis de referência adotados pela Comissão da Comunidade Européia e aos demais resultados encontrados na literatura pesquisada. Recomenda-se a implantação de programas de garantia de qualidade para a redução da dose-paciente com a obtenção de imagens com qualidade para o diagnóstico.
Resumo:
OBJETIVO: O objetivo deste trabalho consiste em estudar a influência da resolução espacial da sonda gama Europrobe que é utilizada em cirurgia radioguiada. MATERIAIS E MÉTODOS: Na técnica de cirurgia radioguiada, após a injeção de um radiotraçador no tumor primário, é utilizada uma sonda detectora de radiação gama a fim de determinar a localização do linfonodo sentinela. Para simular a região dos pontos de injeção do radiotraçador e o linfonodo sentinela, duas fontes de Tc-99m, com 20,42 MBq e 0,70 MBq, foram posicionadas no interior de um recipiente preenchido com água. Em seguida, com a janela de entrada da sonda coberta com um colimador, realizou-se varredura sobre a superfície da água. Assim, foi possível registrar a taxa de contagens variando-se a distância lateral da sonda em relação às duas fontes, as quais foram separadas por uma distância variando entre 30 mm e 60 mm. RESULTADOS: Os resultados mostraram que o uso do colimador contribui para melhorar a resolução espacial da sonda, permitindo a identificação do linfonodo sentinela distante até 30 mm do ponto de injeção. CONCLUSÃO: Esse estudo permite concluir que a sonda Europrobe, quando utilizada com capa colimadora com orifício central de 3,5 mm de diâmetro, é capaz de identificar o linfonodo sentinela posicionado a até 30 mm de distância em relação à região do ponto de injeção do radiotraçador.
Resumo:
OBJETIVO: Foi realizada avaliação da dose de entrada na pele, da dose efetiva e da qualidade da imagem em radiografias de tórax de pacientes adultos. MATERIAIS E MÉTODOS: O estudo realizou-se em oito hospitais, sendo sete públicos (dois filantrópicos) e um particular nos municípios de Angra dos Reis, Cabo Frio, Campos dos Goytacazes, Itaperuna, Niterói, Recife e Rio de Janeiro. Foram avaliadas a dose de entrada na pele e a dose efetiva de 735 radiografias de tórax nas incidências póstero-anterior/ântero-posterior e perfil. No que se refere aos critérios de imagem, foram avaliadas 44 radiografias. RESULTADOS: Constatou-se variação de até nove vezes nos valores da dose de entrada na pele e de até seis vezes na dose efetiva para um mesmo tipo de projeção. Os valores das técnicas radiográficas também apresentaram grandes discrepâncias. A qualidade das imagens também não é boa, pois foi obtido valor médio de presença dos critérios de apenas 55%. CONCLUSÃO: Há necessidade de melhoria/padronização de procedimentos em radiologia convencional, o que pode ser atingido se for implantado um programa de controle e garantia de qualidade no setor de radiologia, incluindo o treinamento dos técnicos, a aferição do desempenho dos equipamentos emissores de radiação e o controle sensitométrico do sistema de processamento radiográfico.
Resumo:
OBJETIVO: Avaliar a freqüência das incidências radiográficas realizadas nos seios da face de pacientes pediátricos em hospitais de Belo Horizonte, MG, as condições de radioproteção, as técnicas radiográficas empregadas, o kerma no ar de entrada e as doses nos órgãos mais expostos. MATERIAIS E MÉTODOS: Foram coletados os dados dos pacientes e parâmetros de técnica radiográfica empregados em exames de crianças de 1 a 16 anos de idade, em cinco salas de quatro hospitais da cidade, observando, também, aspectos de proteção radiológica. O kerma no ar de entrada foi estimado a partir dos rendimentos dos tubos de raios-x e as doses nos órgãos utilizando o software PCXMC. RESULTADOS: Os valores médios do kerma no ar de entrada para as cinco salas foram, respectivamente, 1.398 µGy, 829 µGy, 877 µGy, 1.168 µGy e 3.886 µGy para pacientes entre 1 e 5 anos de idade. CONCLUSÃO: Foi constatado que as incidências mento-naso e fronto-naso são comumente solicitadas em conjunto, na maioria dos hospitais, o que confere dose significativa para os pacientes. Os riscos para os pacientes podem ser diminuídos mediante a utilização de cilindros de colimação, a não-utilização de grades antiespalhamento, o emprego de altos valores de tensão e baixos valores de tempo.
Resumo:
OBJETIVO: Os objetivos deste trabalho são: a) avaliar os procedimentos radiográficos e estimar o valor do kerma no ar na superfície de entrada nos recém-nascidos prematuros submetidos a exames de tórax e abdome, realizados no setor de neonatologia de um hospital público de Belo Horizonte; b) estimar as doses nos órgãos e os respectivos riscos de ocorrência de câncer nesses órgãos em decorrência das exposições à radiação. MATERIAIS E MÉTODOS: Foram analisados os prontuários dos pacientes internados no setor de neonatologia desse hospital durante o período de maio a setembro de 2004, anotando-se os dados antropométricos, data de internação/alta, exames de raios X realizados. O kerma no ar na superfície de entrada foi determinado a partir do rendimento do tubo de raios X e dos parâmetros de irradiação utilizados nos exames. As doses nos órgãos foram estimadas com o software PCXMC e o risco, durante o restante da expectativa de vida, com o software IREP. RESULTADOS: O valor médio do kerma no ar na superfície de entrada por exame foi abaixo do nível de referência da publicação da Comunidade Européia. Para o paciente mais severamente irradiado, os órgãos mais suscetíveis à ocorrência de câncer foram fígado, mama e estômago, com valores máximos de excess relative risk, respectivamente, de 3,4%, 2,3% e 1,7%. CONCLUSÃO: Foi constatada a necessidade de otimização dos procedimentos radiográficos com vista à diminuição do risco para os recém-nascidos, que apesar de ser considerado baixo (comparativamente ao benefício), deve ser sempre diminuído para valores tão baixos quanto razoavelmente exeqüíveis.
Resumo:
OBJETIVO: Este trabalho teve como objetivo estimar os valores de doses de radiação recebidas por médicos e pacientes em procedimentos intervencionistas cardíacos realizados em um hospital público na cidade de Recife, Pernambuco. MATERIAIS E MÉTODOS: As medidas foram determinadas em 31 pacientes adultos, dos quais 22 tiveram acompanhamento clínico após o procedimento, e em dois cardiologistas com mais de dez anos de experiência. Parâmetros de irradiação para cada procedimento foram registrados. RESULTADOS: Os valores obtidos para a dose absorvida máxima na pele do paciente variaram entre 612 e 8.642 mGy, sendo que 53% foram maiores que 2.000 mGy, valores estes que podem causar efeitos determinísticos. Com relação aos médicos, a dose efetiva média por procedimento foi de 11 µSv e os valores médios do equivalente de dose nas extremidades, mais altos, foram: 923 µSv no pé esquerdo, 514 µSv no pé direito, 382 µSv na mão esquerda e 150 µSv no olho esquerdo. Dependendo do número de procedimentos, as doses recebidas pelos médicos podem exceder os valores limites de doses estabelecidos pelas normas nacionais e internacionais. CONCLUSÃO: Os resultados obtidos sinalizam a necessidade de adoção de estratégias para otimização da proteção radiológica tanto de pacientes quanto de médicos.