907 resultados para Grid connected PV systems


Relevância:

30.00% 30.00%

Publicador:

Resumo:

This Master's thesis deals with a Micro Scale Wind Wind Turbine application. The thesis consists of nine chapters. The first chapter is an introduction to the philosophy of a small scale wind turbine application. The second defines concepts, and lists the requirements. The third presents the whole application for an On-Grid , and for an Off-Grid arrangement, with main concentration on lighting, heating, and energy storage. The fourth deals with the Inverter's technology, which are used for the conversion of the produced power. The fifth chapter presents the available storage technology and it's possibilities. The sixth deals with the system, and the technological means used for the implementation. The seventh presents the PLC device, which was used as the controller for the management of the whole application. The eighth deals with the concept and the control application philosophy that the PLC involves. And the final chapter presents conclusions and ideas for further considerations.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study examines Smart Grids and distributed generation, which is connected to a single-family house. The distributed generation comprises small wind power plant and solar panels. The study is done from the consumer point of view and it is divided into two parts. The first part presents the theoretical part and the second part presents the research part. The theoretical part consists of the definition of distributed generation, wind power, solar energy and Smart Grids. The study examines what the Smart Grids will enable. New technology concerning Smart Grids is also examined. The research part introduces wind and sun conditions from two countries. The countries are Finland and Germany. According to the wind and sun conditions of these two countries, the annual electricity production from wind power plant and solar panels will be calculated. The costs of generating electricity from wind and solar energy are calculated from the results of annual electricity productions. The study will also deal with feed-in tariffs, which are supporting systems for renewable energy resources. It is examined in the study, if it is cost-effective for the consumers to use the produced electricity by themselves or sell it to the grid. Finally, figures for both countries are formed. The figures include the calculated cost of generating electricity from wind power plant and solar panels, retail and wholesale prices and feed-in tariffs. In Finland, it is not cost-effective to sell the produced electricity to the grid, before there are support systems. In Germany, it is cost-effective to sell the produced electricity from solar panels to the grid because of feed-in tariffs. On the other hand, in Germany it is cost-effective to produce electricity from wind to own use because the retail price is higher than the produced electricity from wind.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Huoli ympäristön tilasta ja fossiilisten polttoaineiden hinnan nousu ovat vauhdittaneet tutkimusta uusien energialähteiden löytämiseksi. Polttokennot ovat yksi lupaavimmista tekniikoista etenkin hajautetun energiantuotannon, varavoimalaitosten sekä liikennevälineiden alueella. Polttokenno on tehonlähteenä kuitenkin hyvin epäideaalinen, ja se asettaa tehoelektroniikalle lukuisia erityisvaatimuksia. Polttokennon kytkeminen sähköverkkoon on tavallisesti toteutettu käyttämällä galvaanisesti erottavaa DC/DC hakkuria sekä vaihtosuuntaajaa sarjassa. Polttokennon kulumisen estämiseksi tehoelektroniikalta vaaditaan tarkkaa polttokennon lähtövirran hallintaa. Perinteisesti virran hallinta on toteutettu säätämällä hakkurin tulovirtaa PI (Proportional and Integral) tai PID (Proportional, Integral and Derivative) -säätimellä. Hakkurin epälineaarisuudesta johtuen tällainen ratkaisu ei välttämättä toimi kaukana linearisointipisteestä. Lisäksi perinteiset säätimet ovat herkkiä mallinnusvirheille. Tässä diplomityössä on esitetty polttokennon jännitettä nostavan hakkurin tilayhtälökeskiarvoistusmenetelmään perustuva malli, sekä malliin perustuva diskreettiaikainen integroiva liukuvan moodin säätö. Esitetty säätö on luonteeltaan epälineaarinen ja se soveltuu epälineaaristen ja heikosti tunnettujen järjestelmien säätämiseen.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

ABSTRACTSchizolobium parahyba pv. amazonicum (Huber ex Ducke) Barneby (paricá) occurs naturally in the Amazon and is significant commercial importance due to its rapid growth and excellent performance on cropping systems. The aim of this paper was to evaluate a microbial inoculants such as arbuscular mycorrhiza fungi (AMF) and Rhizobium sp. that promote plant growth. The inocula was 10 g of root colonized and spores of Glomus clarum and/or 1 mL of cell suspension (107 CFU/mL) of Rhizobium sp. and/or 100 g of chemical fertilizer NPK 20-05-20 per planting hole. The experimental design was complete randomized blocks with five replications and eight treatments (n = 800). Plant height, stem diameter and plant survival were measured. The results were tested for normality and homogeneity of variances and analyzed by ANOVA and Tukey test (p < 0.05). Rhizobium sp and AM fungi showed no effect on plant growth. Environmental factors probably influenced the effectiveness of symbiosis of both microorganisms and plant growth. The chemical fertilizer increased S. parahyba growth. During the first 120 days plants suffered with drought and frost, and at 180 days plants inoculated with microorganism plus chemical fertilizer showed higher survival when compared with control. The results showed that the microbial inoculants used showed an important role on plant survival after high stress conditions, but not in plant growth. Also was concluded that the planting time should be between November to December to avoid the presence of young plants during winter time that is dry and cold.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this study was to characterize the spatial variability of soil bulk density (Bd), soil moisture content (θ) and total porosity (Tp) in two management systems of sugarcane harvesting, with or without burning, in a Haplustox soil, in the 0-0.20 m layer. The study area is located in Rio Brilhante, state of Mato Grosso do Sul, Brazil, in Eldorado Sugar Mill. The plots have presented 180 m length, and 145.6 m width, totaling 90 points distributed in the form of a grid of nine rows by ten columns, with points spaced 20 m from its neighbor. Soil samples were collected at 0-0.20 m layer in 2007/2008 and 2008/2009 crops. The harvest with burning system had a higher density compared to mechanized harvest, in the two study periods. The moisture content as well as the porosity increased proportionally with the decrease of the density of the harvest burning system compared to the mechanized.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this doctoral thesis, a power conversion unit for a 10 kWsolid oxide fuel cell is modeled, and a suitable control system is designed. The need for research was identified based on an observation that there was no information available about the characteristics of the solid oxide fuel cell from the perspective of power electronics and the control system, and suitable control methods had not previously been studied in the literature. In addition, because of the digital implementation of the control system, the inherent characteristics of the digital system had to be taken into account in the characteristics of the solid oxide fuel cell (SOFC). The characteristics of the solid oxide fuel cell as well the methods for the modeling and control of the DC/DC converter and the grid converter are studied by a literature survey. Based on the survey, the characteristics of the SOFC as an electrical power source are identified, and a solution to the interfacing of the SOFC in distributed generation is proposed. A mathematical model of the power conversion unit is provided, and the control design for the DC/DC converter and the grid converter is made based on the proposed interfacing solution. The limit cycling phenomenon is identified as a source of low-frequency current ripple, which is found to be insignificant when connected to a grid-tied converter. A method to mitigate a second harmonic originating from the grid interface is proposed, and practical considerations of the operation with the solid oxide fuel cell plant are presented. At the theoretical level, the thesis discusses and summarizes the methods to successfully derive a model for a DC/DC converter, a grid converter, and a power conversion unit. The results of this doctoral thesis can also be used in other applications, and the models and methods can be adopted to similar applications such as photovoltaic systems. When comparing the results with the objectives of the doctoral thesis, we may conclude that the objectives set for the work are met. In this doctoral thesis, theoretical and practical guidelines are presented for the successful control design to connect a SOFC-based distributed generation plant to the utility grid.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The distinction between lymphatic vessels and blood vessels is a crucial factor in many studies in immunology, vascular biology and cancer biology. They both share several characteristics and perform related, though different functions. They are equally important for the performance of the human immune system with the continuous recirculation of leukocytes from the tissues via lymphatics to the blood vessels and back into the tissue presenting the link between both systems. This study was undertaken to elucidate the differences in the gene expression between primary blood- and lymphatic endothelial cells as well as the two immortalized cell lines HMEC-1 (human microvascular endothelial cell line 1) and TIME (telomerase immortalized microvascular endothelial cell line). Furthermore, we wanted to investigate the mystery surrounding the identity of the antigen recognized by the prototype blood vascular marker PAL-E. In the last step we wanted to study whether the PAL-E antigen would be involved in the process of leukocyte migration from the bloodstream into the surrounding tissue. Our results clearly show that the gene expression in primary blood endothelial cells (BEC), lymphatic endothelial cells (LEC) and the cell lines HMEC-1 and TIME is plastic. Comparison of a large set of BEC- and LEC datasets allowed us to assemble a catalog of new, stable BEC- or LEC specific markers, which we verified in independent experiments. Additionally, several lines of evidence demonstrated that PAL-E recognizes plasmalemma vesicle associated protein 1 (PV-1), which can form complexes with vimentin and neuropilin-1. Finally, numerous in vitro and in vivo experiments identify the first function of the protein PV-1 during leukocyte trafficking, where it acts as regulatory molecule.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The pumping processes requiring wide range of flow are often equipped with parallelconnected centrifugal pumps. In parallel pumping systems, the use of variable speed control allows that the required output for the process can be delivered with a varying number of operated pump units and selected rotational speed references. However, the optimization of the parallel-connected rotational speed controlled pump units often requires adaptive modelling of both parallel pump characteristics and the surrounding system in varying operation conditions. The available information required for the system modelling in typical parallel pumping applications such as waste water treatment and various cooling and water delivery pumping tasks can be limited, and the lack of real-time operation point monitoring often sets limits for accurate energy efficiency optimization. Hence, alternatives for easily implementable control strategies which can be adopted with minimum system data are necessary. This doctoral thesis concentrates on the methods that allow the energy efficient use of variable speed controlled parallel pumps in system scenarios in which the parallel pump units consist of a centrifugal pump, an electric motor, and a frequency converter. Firstly, the suitable operation conditions for variable speed controlled parallel pumps are studied. Secondly, methods for determining the output of each parallel pump unit using characteristic curve-based operation point estimation with frequency converter are discussed. Thirdly, the implementation of the control strategy based on real-time pump operation point estimation and sub-optimization of each parallel pump unit is studied. The findings of the thesis support the idea that the energy efficiency of the pumping can be increased without the installation of new, more efficient components in the systems by simply adopting suitable control strategies. An easily implementable and adaptive control strategy for variable speed controlled parallel pumping systems can be created by utilizing the pump operation point estimation available in modern frequency converters. Hence, additional real-time flow metering, start-up measurements, and detailed system model are unnecessary, and the pumping task can be fulfilled by determining a speed reference for each parallel-pump unit which suggests the energy efficient operation of the pumping system.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This pro gradu –thesis discusses generating competitive advantage through competitor information systems. The structure of this thesis follows the structure of the WCA model by Alter (1996). In the WCA model, business process is influenced by three separate but connected elements: information, technology, and process participants. The main research question is how competitor information can be incorporated into or made into a tool creating competitive advantage. Research subquestions are: How does competitor information act as a part of the business process creating competitive advantage? How is a good competitor information system situated and structured in an organisation? How can management help information generate competitive advantage in the business process with participants, information, and technology? This thesis discusses each of the elements separate, but the elements are connected to each other and to competitive advantage. Information is discussed by delving into competitor information and competitor analysis. Competitive intelligence and competitor analysis requires commitment throughout the organisation, including top management, the desire to perform competitive intelligence and the desire to use the end products of that competitive intelligence. In order to be successful, systematic competitive intelligence and competitor analysis require vision, willingness to strive for the goals set, and clear strategies to proceed. Technology is discussed by taking a look into the function of the competitor information systems play and the place they occupy within an organization. In addition, there is discussion about the basic infrastructure of competitor information systems, and the problems competitor information systems can have plaguing them. In order for competitor information systems to be useful and worthy of the resources it takes to develop and maintain them, competitor information systems require on-going resource allocation and high quality information. In order for competitor information systems justify their existence business process participants need to maintain and utilize competitor information systems on all levels. Business process participants are discussed through management practices. This thesis discusses way to manage information, technology, and process participants, when the goal is to generate competitive advantage through competitor information systems. This is possible when information is treated as a resource with value, technology requires strategy in order to be successful within an organization, and process participants are an important resource. Generating competitive advantage through competitor information systems is possible when the elements of information, technology, and business process participants all align advantageously.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

An electric system based on renewable energy faces challenges concerning the storage and utilization of energy due to the intermittent and seasonal nature of renewable energy sources. Wind and solar photovoltaic power productions are variable and difficult to predict, and thus electricity storage will be needed in the case of basic power production. Hydrogen’s energetic potential lies in its ability and versatility to store chemical energy, to serve as an energy carrier and as feedstock for various industries. Hydrogen is also used e.g. in the production of biofuels. The amount of energy produced during hydrogen combustion is higher than any other fuel’s on a mass basis with a higher-heating-value of 39.4 kWh/kg. However, even though hydrogen is the most abundant element in the universe, on Earth most hydrogen exists in molecular forms such as water. Therefore, hydrogen must be produced and there are various methods to do so. Today, the majority hydrogen comes from fossil fuels, mainly from steam methane reforming, and only about 4 % of global hydrogen comes from water electrolysis. Combination of electrolytic production of hydrogen from water and supply of renewable energy is attracting more interest due to the sustainability and the increased flexibility of the resulting energy system. The preferred option for intermittent hydrogen storage is pressurization in tanks since at ambient conditions the volumetric energy density of hydrogen is low, and pressurized tanks are efficient and affordable when the cycling rate is high. Pressurized hydrogen enables energy storage in larger capacities compared to battery technologies and additionally the energy can be stored for longer periods of time, on a time scale of months. In this thesis, the thermodynamics and electrochemistry associated with water electrolysis are described. The main water electrolysis technologies are presented with state-of-the-art specifications. Finally, a Power-to-Hydrogen infrastructure design for Lappeenranta University of Technology is presented. Laboratory setup for water electrolysis is specified and factors affecting its commissioning in Finland are presented.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Hajautettu sähköntuotanto aurinkopaneeleilla on Suomessa kasvussa. Kotitalouksiin asennettujen aurinkopaneelijärjestelmien määrä kasvaa jatkuvasti, mutta suuri osa tuotetusta sähköenergiasta syötetään sähköverkkoon. Tämä johtuu aurinkosähkön tuotannon painottumisesta kesäpäiviin, jolloin kotitalouksien kulutus on pienimmillään. Suurin hyöty itse tuotetusta energiasta saadaan kuitenkin käyttämällä se tuotantokohteessa, jolla minimoidaan energiansiirto sähköverkon ja kotitalouden rajapinnassa. Siirtämällä kotitalouden suurimpia kuormia aurinkosähkön mukaan ohjatuksi, voidaan saavuttaa merkittäviä parannuksia tuotetun sähkön omakäyttöasteessa. Helpoimmillaan tämä onnistuu kellokytkimellä, joka ajoittaa kulutuksen parhaimman tuotannon ajalle. Tämä ei kuitenkaan poista ongelmaa tilanteissa, jossa aurinkosähkön tuotanto on häiriintynyt esimerkiksi pilvisyyden takia aamupäivällä ja huipputuotanto saavutetaan vasta iltapäivän puolella. Saatavilla on jo useita järjestelmiä, jotka ohjaavat kodin laitteita tuotannon mukaisesti. Suuri osa näistä järjestelmistä on kuitenkin suunniteltu toimimaan vain tuotetun energiamäärän mukaisesti, ottamatta huomioon kotitaloudessa olevaa muuta, automaation piiriin kuulumatonta kulutusta. Tässä kandidaatin työssä vertaillaan sähköenergian eri mittaustapoja ja niiden vaikutusta siirretyn energian laskennalliseen määrään. Lisäksi työssä tutkitaan lämminvesivaraajan kuormanohjausta käyttäen termostaatti-, kellokytkin- ja logiikkaohjausta. Työssä esitelty logiikkaohjaus hyödyntää siirretyn energian mittausta sähköverkon ja kotitalouden rajapinnassa, ottaen automaattisesti huomioon myös talouden muun kulutuksen. Työssä esitellään myös esimerkkilaitteisto, jolla suunniteltu logiikka voidaan toteuttaa.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Increasingly growing share of distributed generation in the whole electrical power system’s generating system is currently a worldwide tendency, driven by several factors, encircling mainly difficulties in refinement of megalopolises’ distribution networks and its maintenance; widening environmental concerns adding to both energy efficiency approaches and installation of renewable sources based generation, inherently distributed; increased power quality and reliability needs; progress in IT field, making implementable harmonization of needs and interests of different-energy-type generators and consumers. At this stage, the volume, formed by system-interconnected distributed generation facilities, have reached the level of causing broad impact toward system operation under emergency and post-emergency conditions in several EU countries, thus previously implementable approach of their preliminary tripping in case of a fault, preventing generating equipment damage and disoperation of relay protection and automation, is not applicable any more. Adding to the preceding, withstand capability and transient electromechanical stability of generating technologies, interconnecting in proximity of load nodes, enhanced significantly since the moment Low Voltage Ride-Through regulations, followed by techniques, were introduced in Grid Codes. Both aspects leads to relay protection and auto-reclosing operation in presence of distributed generation generally connected after grid planning and construction phases. This paper proposes solutions to the emerging need to ensure correct operation of the equipment in question with least possible grid refinements, distinctively for every type of distributed generation technology achieved its technical maturity to date and network’s protection. New generating technologies are equivalented from the perspective of representation in calculation of initial steady-state short-circuit current used to dimension current-sensing relay protection, and widely adopted short-circuit calculation practices, as IEC 60909 and VDE 0102. The phenomenon of unintentional islanding, influencing auto-reclosing, is addressed, and protection schemes used to eliminate an sustained island are listed and characterized by reliability and implementation related factors, whereas also forming a crucial aspect of realization of the proposed protection operation relieving measures.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Tutkimuksessa käsitelty kemikaalitehdas on 110 kV:n kantaverkkoon liittyvä tehointensiivinen teollisuuslaitos. Prosessien käyttöön mukautetut sähkönjakeluverkon yliaaltosuodattimet ja niiden käyttökytkennät ovat tärkeässä asemassa loistehon tuoton hallitsemiseksi liittymän loistehoikkunaan ja riittävän yliaaltosuodatuksen järjestämiseksi häviöt minimoiden. Kohteena olleen kemikaalitehtaan sähkönjakeluverkon kompensointia ja yliaaltosuodatusta on viimeksi tutkittu vuonna 2003. Tämän jälkeen verkostokomponentit ovat ikääntyneet, prosessien käyttö sekä pienjänniteverkko ovat muuttuneet ja tehdasta käyttävät osittain eri henkilöt. Nykytilaselvitykselle ja verkon kehityskohteiden analysoinnille on tullut tarve edellisen selvityksen jatkoksi. Tutkimus painottuu vahvasti kenttämittauksiin, joiden perusteella sekä kirjallisuutta ja tehtaan järjestelmiä hyödyntäen määritetään loistehotasot verkon keskeisimmissä kohteissa pien-, keski- ja suurjännitetasoilla. Tutkimuksessa esitetään lipeätehtaan suotimien uudelleenjärjestely 4. yliaallon vähentämiseksi ja yksikkökoon pienentämiseksi. Kantaverkon liittymäpisteen tilanne oli hyväksyttävä. Tutkimus esittää pienjännitekompensointia KF-4-100 keskukseen varayhteyden kapasiteettia lisäten. Tutkimus tuotti yleistietoutta verkon käytöstä ja selvitti parhaat käyttökytkennät loistehoikkunan hallitsemiseksi ilman loistehokustannuksia.