957 resultados para Fixed Assets


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Formalin fixation and paraffin embedding (FFPE) is the most commonly used method worldwide for tissue storage. This method preserves the tissue integrity but causes extensive damage to nucleic acids stored within the tissue. As methods for measuring gene expression such as RT-PCR and microarray are adopted into clinical practice there is an increasing necessity to access the wealth of information locked in the Formalin fixation and paraffin embedding archives. This paper reviews the progress in this field and discusses the unique opportunities that exist for the application of these techniques in the development of personalized medicine.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work involved the treatment of industrial wastewater from a nylon carpet printing plant which currently receives no treatment and is discharged to sea. As nylon is particularly difficult to dye, acid dyes are required for successful coloration and cause major problems with the plant's effluent disposal in terms of color removal. Granular activated carbon Filtrasorb 400 was used to treat a ternary solution of acid dyes and the process plant effluent containing the dyes in a fixed-bed column system. Experimental data were correlated using the bed depth service time (BDST) model to previously published work by the authors for single dye adsorption. The results were expressed in terms of the BDST adsorption capacity, in milligrams of adsorbate per gram of adsorbent, and indicated that there was a 12-25% decrease iri adsorption capacity in the ternary system compared to the single component system; This reduction has been attributed to competitive adsorption occurring in the ternary component system. Dye adsorption from the process plant effluent showed an approximate 65% decrease in adsorption capacity compared to the ternary solution system. This has been attributed to interference caused by the other colorless textile effluent pollutants found in the process wastewater. A chemical oxygen demand analysis on these components indicated that the dyes accounted for only 14% of the total oxygen demand.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper, we provide experimental evidence to show that enhanced bit error rate (BER) performance is possible using a retrodirective array operating in a dynamically varying multipath environment. The operation of such a system will be compared to that obtained by a conventional nonretrodirective array. The ability of the array to recover amplitude shift keyed encoded data transmitted from a remote location whose position is not known a priori is described. In addition, its ability to retransmit data inserted at the retrodirective array back to a spatially remote beacon location whose position is also not known beforehand is also demonstrated. Comparison with an equivalent conventional fixed beam antenna array utilizing an identical radiating aperture arrangement to that of the retrodirective array are given. These show that the retrodirective array can effectively exploit the presence of time varying multipath in order to give significant reductions in BER over what can be otherwise achieved. Additionally, the retrodirective system is shown to be able to deliver low BER regardless of whether line of sight is present or absent.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The increasing penetration of wind generation on the Island of Ireland has been accompanied by close investigation of low-frequency pulsations contained within active power flow. A primary concern is excitation of low-frequency oscillation modes already present on the system, particularly the 0.75 Hz mode as a consequence of interconnection between the Northern and Southern power system networks. In order to determine whether the prevalence of wind generation has a negative effect (excites modes) or positive impact (damping of modes) on the power system, oscillations must be measured and characterised. Using time – frequency methods, this paper presents work that has been conducted to extract features from low-frequency active power pulsations to determine the composition of oscillatory modes which may impact on dynamic stability. The paper proposes a combined wavelet-Prony method to extract modal components and determine damping factors. The method is exemplified using real data obtained from wind farm measurements.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The consideration of the limit theory in which T is fixed and N is allowed to go to infinity improves the finite-sample properties of the tests and avoids the imposition of the relative rates at which T and N go to infinity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Importance of the field: Type 2 diabetes is typically associated with insulin resistance and dysfunction of insulin-secreting pancreatic beta-cells. Addressing these defects often requires therapy with a combination of differently acting antidiabetic agents. A potential novel combination in development brings together the dipeptidyl peptidase-4 (DPP-4) inhibitor sitagliptin with the thiazolidinedione pioglitazone into a fixed-dose single-tablet combination. The former component acts mainly to increase prandial insulin secretion; the latter improves insulin sensitivity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper evaluates the desirability of PPP rules vis-á-vis fixed exchange rates both in terms of welfare and stability properties. The analysis is conducted within a small open-economy New Keynesian framework extended to include a cost channel. In terms of stability, we find that while the equilibrium is always unique under fixed exchange rates its uniqueness critically depends upon the presence/absence of the cost channel under a PPP rule. Overall, then, in terms of welfare a fixed exchange rate always outperforms a PPP rule.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: Our objective was to determine which factors were predictive of good long-term outcomes after fixed appliance treatment of Class II Division 1 malocclusion. Methods: Two hundred seven patients with Class II Division 1 malocclusion were examined in early adulthood at a mean of 4.6 years after treatment with fixed appliances. The peer assessment rating index was used to evaluate dental alignment and occlusal relationships. The soft-tissue profile was assessed with the Holdaway angle. Results: Logistic regression identified 3 pretreatment variables that were predictive of a good facial profile (Holdaway angle) at recall: the lower lip to E-plane distance (P

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The development of high performance, low computational complexity detection algorithms is a key challenge for real-time Multiple-Input Multiple-Output (MIMO) communication system design. The Fixed-Complexity Sphere Decoder (FSD) algorithm is one of the most promising approaches, enabling quasi-ML decoding accuracy and high performance implementation due to its deterministic, highly parallel structure. However, it suffers from exponential growth in computational complexity as the number of MIMO transmit antennas increases, critically limiting its scalability to larger MIMO system topologies. In this paper, we present a solution to this problem by applying a novel cutting protocol to the decoding tree of a real-valued FSD algorithm. The new Real-valued Fixed-Complexity Sphere Decoder (RFSD) algorithm derived achieves similar quasi-ML decoding performance as FSD, but with an average 70% reduction in computational complexity, as we demonstrate from both theoretical and implementation perspectives for Quadrature Amplitude Modulation (QAM)-MIMO systems.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper outlines the use of phasor measurement unit (PMU) records to validate models of fixed speed induction generator (FSIG)-based wind farms during frequency transients. Wind turbine manufacturers usually create their own proprietary models which they can supply to power system utilities for stability studies, subject to confidentiality agreements. However, it is desirable to confirm the accuracy of supplied models with measurements from the particular installation, in order to assess their validity under real field conditions. This is prudent due to possible changes in control algorithms and design retrofits, not accurately reflected or omitted in the supplied model. One important aspect of such models, especially for smaller power systems with limited inertia, is their accuracy during system frequency transients. This paper, therefore, assesses the accuracy of FSIG models with regard to frequency stability, and hence validates a subset of the model dynamics. Such models can then be used with confidence to assess wider system stability implications. The measured and simulated response of a wind farm using doubly fed induction generator (DFIG) technology is also assessed.