877 resultados para Fault coverage
Resumo:
This paper proposes a new approach for optimal phasor measurement units placement for fault location on electric power distribution systems using Greedy Randomized Adaptive Search Procedure metaheuristic and Monte Carlo simulation. The optimized placement model herein proposed is a general methodology that can be used to place devices aiming to record the voltage sag magnitudes for any fault location algorithm that uses voltage information measured at a limited set of nodes along the feeder. An overhead, three-phase, three-wire, 13.8 kV, 134-node, real-life feeder model is used to evaluate the algorithm. Tests show that the results of the fault location methodology were improved thanks to the new optimized allocation of the meters pinpointed using this methodology. © 2011 IEEE.
Resumo:
In this paper we propose an accurate method for fault location in underground distribution systems by means of an Optimum-Path Forest (OPF) classifier. We applied the Time Domains Reflectometry method for signal acquisition, which was further analyzed by OPF and several other well known pattern recognition techniques. The results indicated that OPF and Support Vector Machines outperformed Artificial Neural Networks classifier. However, OPF has been much more efficient than all classifiers for training, and the second one faster for classification. © 2011 IEEE.
Resumo:
In this paper we propose a fast and an accurate method for fault diagnosis in power transformers by means of Optimum-Path Forest (OPF) classifier. Since we applied Dissolved Gas Analysis (DGA), the samples have been labeled by IEEE/IEC standard, which was further analyzed by OPF and several other well known supervised pattern recognition techniques. The experiments have showed that OPF can achieve high recognition rates with low computational cost. © 2012 IEEE.
Resumo:
The need for high reliability and environmental concerns are making the underground networks the most appropriate choice of energy distribution. However, like any other system, underground distribution systems are not free of failures. In this context, this work presents an approach to study underground systems using computational tools by integrating the software PSCAD/EMTDC with artificial neural networks to assist fault location in power distribution systems. Targeted benefits include greater accuracy and reduced repair time. The results presented here shows the feasibility of the proposed approach. © 2012 IEEE.
Resumo:
One of the main purposes of mucogingival therapy is to obtain full root coverage. Several treatment modalities have been developed, but few techniques can provide complete root coverage in a class III Miller recession. Thus, the aim of this case report is to present a successful clinical case of a Miller class III gingival recession in which complete root coverage was obtained by means of a multidisciplinary approach. A 17-year-old Caucasian female was referred for treatment of a gingival recession on the mandibular left central incisor. The following procedures were planned for root coverage in this case: free gingival graft, orthodontic movement by means of alignment and leveling and coronally advanced flap (CAF). The case has been followed up for 12 years and the patient presents no recession, no abnormal probing depth and no bleeding on probing, with a wide attached gingiva band. A compromised tooth with poor prognosis, which would be indicated for extraction, can be treated by orthodontic movement and periodontal therapy, with possibility of 100% root coverage in some class III recessions.
Resumo:
Includes bibliography
Resumo:
Objectives: The aim of this study was to compare the long-term clinical effects produced by subepithelial connective tissue graft (SCTG) and guided tissue regeneration combined with demineralized freeze-dried bone allograft (GTR-DFDBA) in the treatment of gingival recessions in a 30-month follow-up clinical trial. Methods: Twenty-four defects were treated in 12 patients who presented canine or pre-molar Miller class I and/or II bilateral gingival recessions. GTR-DFDBA and SCTG treatments were performed in a randomized selection in a split-mouth design. The clinical measurements included root coverage (RC), gingival recession (GR), probing depth (PD), clinical attachment level (CAL) and keratinized tissue width (KTW). These clinical parameters were evaluated at baseline and after 6, 18 and 30 months post-surgery. Results: The changes in RC, GR, PD and CAL did not show significant differences between groups (p > 0.05). Both procedures promoted similar RC (GTR-DFDBA: 87% and SCTG: 95.5%) and similar reduction in GR (GTR-DFDBA: 3.25 mm and SCTG: 3.9 mm), PD (GTR-DFDBA: 1.6 mm and SCTG: 1.2 mm) and CAL (GTR-DFDBA: 4.9 mm and SCTG: 5.0 mm). The increase in KTW was significantly higher (p = 0.02) in the SCTG group (3.5 mm) than in the GTR-DFDBA group (2.4 mm). Conclusions: Both techniques for treatment of gingival recession (SCTG and GTR-DFDBA) lead to favourable and long-term stable results, but SCTG promoted a more favourable increase in keratinized tissue. © 2012 Elsevier Ltd. All rights reserved.
Resumo:
Nowadays the method based on demodulation by envelope finds wide application in industry as a technique for evaluation of bearings and other components in rotating machinery. In recent years the application of Wavelets for fault diagnosis in machinery has also obtained good development. This article demonstrates the effectiveness of the combined application of Wavelets and envelope technique (also known as HFRT High-Frequency Resonance Technique) to remove background noise from signals collected from defect bearings and identification of the characteristic frequencies of defects. A comparison of the results obtained with the isolated application of only one method against the combined technique is performed showing the increased capacity in detection of faults in rolling bearings. © (2013) Trans Tech Publications, Switzerland.
Resumo:
In this work, we report on the evaluation of a superconducting fault current limiter (SFCL). It is consisted of a modular superconducting device combined with a short-circuited transformer with a primary copper winding connected in series to the power line and the secondary side short-circuited by the superconducting device. The basic idea is adding a magnetic component to contribute to the current limitation by the impedance reflected to the line after transition of the superconducting device. The evaluation tests were performed with a prospective current up to 2 kA, with the short-circuited transformer of 2.5 kVA, 220 V/660 V connected to a test facility of 100 kVA power capacity. The resistive SFCL using a modular superconducting device was tested without degradation for a prospective fault current of 1.8 kA, achieving the limiting factor 2.78; the voltage achieved 282 V corresponding to an electric field of 11 V/m. The test performed with the combined SFCL (xsuperconducting device + transformer) using series and toroidal transformers showed current limiting factor of 3.1 and 2 times, respectively. The test results of the combined SFCL with short-circuited transformer showed undesirable influence of the transformer impedance, resulting in reduction of the fault current level. © 2002-2011 IEEE.
Resumo:
We performed a quantitative analysis of M and P cell mosaics of the common-marmoset retina. Ganglion cells were labeled retrogradely from optic nerve deposits of Biocytin. The labeling was visualized using horseradish peroxidase (HRP) histochemistry and 3-3'diaminobenzidine as chromogen. M and P cells were morphologically similar to those found in Old- and New-World primates. Measurements were performed on well-stained cells from 4 retinas of different animals. We analyzed separate mosaics for inner and outer M and P cells at increasing distances from the fovea (2.5-9 mm of eccentricity) to estimate cell density, proportion, and dendritic coverage. M cell density decreased towards the retinal periphery in all quadrants. M cell density was higher in the nasal quadrant than in other retinal regions at similar eccentricities, reaching about 740 cells/mm2 at 2.5 mm of temporal eccentricity, and representing 8-14% of all ganglion cells. P cell density increased from peripheral to more central regions, reaching about 5540 cells/mm2 at 2.5 mm of temporal eccentricity. P cells represented a smaller proportion of all ganglion cells in the nasal quadrant than in other quadrants, and their numbers increased towards central retinal regions. The M cell coverage factor ranged from 5 to 12 and the P cell coverage factor ranged from 1 to 3 in the nasal quadrant and from 5 to 12 in the other quadrants. These results show that central and peripheral retinal regions differ in terms of cell class proportions and dendritic coverage, and their properties do not result from simply scaling down cell density. Therefore, differences in functional properties between central and peripheral vision should take these distinct regional retinal characteristics into account.
Resumo:
A ligação entre as zonas urbanas e as questões ambientais ficam mais próximas na medida em que cresce a conscientização global de conservar, melhorar e valorizar os serviços ambientais prestados pela natureza para a sustentabilidade da vida, dentro e fora da cidade. Cobertura vegetal (ou cobertura verde) está dentre as principais fontes de tais serviços. Uma vez que o processo de urbanização se mostra irreversível e os problemas ambientais urbanos se alastram em tamanho e extensão, a presença do verde está diretamente relacionada aos indicadores de qualidade de vida urbana. Como reflexo do processo de urbanização, a cidade de Belém perdeu uma grande porcentagem de seus ecossistemas naturais, de modo que este trabalho se concentrou em analisar alguns serviços ecossistêmicos—qualidade do ar, poluição do ar e regulação do clima - fornecidos pela qualidade e pela quantidade de cobertura vegetal local, considerando as alterações na distribuição espaço-temporal, em três distritos administrativos. Um marco teórico foi construído e analisado; a cobertura vegetal foi calculada, utilizando-se NDVI e Cobertura Vegetal Fracional em imagens do LANDSAT 5, ao longo de um período de 23 anos. A partir de uma proposta de escala mais detalhada de NDVI, análises quantitativas e qualitativas da cobertura verde evidenciaram perda significativa de cobertura muito densa, densa, moderada e aumento de áreas de pouca ou nenhuma vegetação. Ademais, lesão das áreas verdes sinalizou tendências de aumento da poluição do ar, da poluição sonora e da temperatura. A carência de dados relacionados ao meio ambiente não deixa dúvida sobre a urgência de investimento nos serviços ambientais provenientes da cobertura vegetal, para a sustentabilidade urbana em Belém, cujos cenários previstos são de drásticas perdas de área verde. Mais pesquisas e iniciativas de instituições públicas e privadas são necessárias para a contribuição aos serviços ambientais em Belém e, consequentemente, ao bem-estar público.
Resumo:
Far from the continental margin, drainage basins in Central Amazonia should be in topographic steady state; but they are not. Abandoned remnant fluvial valleys up to hundreds of square kilometers in size are observed throughout Amazonia, and are evidence of significant landscape reorganization. While major Late Miocene drainage shifts occurred due to initiation of the transcontinental Amazon River, local landscape change has remained active until today. Driven either by dynamic topography, tectonism, and/or climatic fluctuations, drainage captures in Amazonia provide a natural experiment for assessing the geomorphic response of low-slope basins to sudden, capture related base-level falls. This paper evaluates the timing of geomorphic change by examining a drainage capture event across the Baependi fault scarp involving the Cuieiras and TarumA-Mirim River basins northwest of the city of Manaus in Brazil. A system of capture-related knickpoints was generated by base-level fall following drainage capture; through numerical modeling of their initiation and propagation, the capture event is inferred to have occurred between the middle and late Pleistocene, consistent with other studies of landscape change in surrounding areas. In low-slope settings like the Amazon River basin, base-level fall can increase erosion rates by more than an order of magnitude, and moderate to large river basins can respond to episodes of base-level fall over timescales of tens to hundreds of thousands of years. Copyright (c) 2013 John Wiley & Sons, Ltd.
Resumo:
The concept of Functional Urban Regions (FURs), also called Metropolitan Regions (MRs), is not simple. It is clear, though, that they are not simply a combination of adjacent municipalities or areas. Different methods can be used for their definition. However, especially in developing countries, the application of some methods is not possible, due to the unavailability of detailed data. Alternative approaches have been developed based on spatial analysis methods and using variables extracted from available data. The objective of this study is to compare the results of two spatial analysis methods exploring two variables: population density and an indicator of transport infrastructure supply. The first method regards Exploratory Spatial Data Analyses tools, which define uniform regions based on specific variables. The second method used the same variables and the spatial analysis technique available in the computer program SKATER - Spatial 'K'luster Analysis by Tree Edge Removal. Assuming that those classifications of regions with similar characteristics can be used for identifying potential FURS, the results of all analyses were compared with one another and with the 'official' MR. A combined approach was also considered for comparison, but none of the results match the existing MR boundaries, what challenges the official definitions. (C) 2014 Elsevier Ltd. All rights reserved.
Resumo:
A superconducting fault current limiter (SCFL) consisted of a transformer with low reactance connected to the power line and with the secondary winding short-circuited by a modular superconducting limiter device with 16 elements connected in series was constructed and tested. The designed coupling transformer has low dispersion reactance in order to limit the voltage drop in the power line within the range of 5 % to 10 %. The experimental results showed that an insertion of a 0.125 Omega resistance limited the peak current to a factor of 2.5 times of the unlimited current. The power dissipation reached 39 kW during 100 ms, with an energy density of 380 J/cm(3). Based on these results, the SCFL will be further tested in a 3 MVA (15 kV/380 V) generator for currents up to 10 kA.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)