988 resultados para Fantôme de calibration
Resumo:
The first operations at the new High-altitude Maïdo Observatory at La Réunion began in 2013. The Maïdo Lidar Calibration Campaign (MALICCA) was organized there in April 2013 and has focused on the validation of the thermodynamic parameters (temperature, water vapor, and wind) measured with many instruments including the new very large lidar for water vapor and temperature profiles. The aim of this publication consists of providing an overview of the different instruments deployed during this campaign and their status, some of the targeted scientific questions and associated instrumental issues. Some specific detailed studies for some individual techniques were addressed elsewhere. This study shows that temperature profiles were obtained from the ground to the mesopause (80 km) thanks to the lidar and regular meteorological balloon-borne sondes with an overlap range showing good agreement. Water vapor is also monitored from the ground to the mesopause by using the Raman lidar and microwave techniques. Both techniques need to be pushed to their limit to reduce the missing range in the lower stratosphere. Total columns obtained from global positioning system or spectrometers are valuable for checking the calibration and ensuring vertical continuity. The lidar can also provide the vertical cloud structure that is a valuable complementary piece of information when investigating the water vapor cycle. Finally, wind vertical profiles, which were obtained from sondes, are now also retrieved at Maïdo from the newly implemented microwave technique and the lidar. Stable calibrations as well as a small-scale dynamical structure are required to monitor the thermodynamic state of the middle atmosphere, ensure validation of satellite sensors, study the transport of water vapor in the vicinity of the tropical tropopause and study their link with cirrus clouds and cyclones and the impact of small-scale dynamics (gravity waves) and their link with the mean state of the mesosphere.
Resumo:
The goal of this work was to increase the performance and to calibrate one of the ROSINA sensors, the Reflectron-type Time-Of-Flight mass spectrometer, currently flying aboard the ESA Rosetta spacecraft. Different optimization techniques were applied to both the lab and space models, and a static calibration was performed using different gas species expected to be detected in the vicinity of comet 67P/Churyumov-Gerasimenko. The database thus created was successfully applied to space data, giving consistent results with the other ROSINA sensors.
Resumo:
The goal of this work has been to calibrate sensitivities and fragmentation pattern of various molecules as well as further characterize the lab model of the ROSINA Double Focusing Mass Spectrometer (DFMS) on board ESA’s Rosetta spacecraft bound to comet 67P/Churyumov-Gerasimenko. The detailed calibration and characterization of the instrument is key to understand and interpret the results in the coma of the comet. A static calibration was performed for the following species: Ne, Ar, Kr, Xe, H2O, N2, CO2, CH4, C2H6, C3H8, C4H10, and C2H4. The purpose of the calibration was to obtain sensitivities for all detectors and emissions, the fragmentation behavior of the ion source and to show the capabilities to measure isotopic ratios at the comet. The calibration included the recording of different correction factors to evaluate the data, including a detailed investigation of the detector gain. The quality of the calibration that could be tested for different gas mixtures including the calibration of the density inside the ion source when calibration gas from the gas calibration unit is introduced. In conclusion the calibration shows that DFMS meets the design requirements and that DFMS will be able to measure the D/H at the comet and help shed more light on the puzzle about the origin of water on Earth.
Resumo:
We calibrated the ⁸¹Kr-Kr dating system for ordinary chondrites of different sizes using independent shielding-corrected ³⁶Cl-³⁶Ar ages. Krypton concentrations and isotopic compositions were measured in bulk samples from 14 ordinary chondrites of high petrologic type and the cosmogenic Kr component was obtained by subtracting trapped Kr from phase Q. The thus-determined average cosmogenic ⁷⁸Kr/⁸³Kr, ⁸⁰Kr/⁸³Kr, ⁸²Kr/⁸³Kr, and ⁸4Kr/⁸³Kr ratiC(Lavielle and Marti 1988; Wieler 2002). The cosmogenic ⁷⁸Kr/⁸³Kr ratio is correlated with the cosmogenic 22Ne/21Ne ratio, confirming that ⁷⁸Kr/⁸³Kr is a reliable shielding indicator. Previously, ⁸¹Kr-Kr ages have been determined by assuming the cosmogenic production rate of ⁸¹Kr, P(⁸¹Kr)c, to be 0.95 times the average of the cosmogenic production rates of ⁸⁰Kr and ⁸²Kr; the factor Y = 0.95 therefore accounts for the unequal production of the various Kr isotopes (Marti 1967a). However, Y should be regarded as an empirical adjustment. For samples whose ⁸⁰Kr and ⁸²Kr concentrations may be affected by neutron-capture reactions, the shielding-dependent cosmogenic (⁷⁸Kr/⁸³Kr)c ratio has been used instead to calculate P(⁸¹Kr)/P(⁸³Kr), as for some lunar samples, this ratio has been shown to linearly increase with (⁷⁸Kr/⁸³Kr)c (Marti and Lugmair 1971). However, the ⁸¹Kr-Kr ages of our samples calculated with these methods are on average ~30% higher than their ³⁶Cl-³⁶Ar ages, indicating that most if not all the ⁸¹Kr-Kr ages determined so far are significantly too high. We therefore re-evaluated both methods to determine P(⁸¹Kr)c/P(⁸³Kr)c. Our new Y value of 0.70 ± 0.04 is more than 25% lower than the value of 0.95 used so far. Furthermore, together with literature data, our data indicate that for chondrites, P(⁸¹Kr)c/P(⁸³Kr)c is rather constant at 0.43 ± 0.02, at least for the shielding range covered by our samples ([⁷⁸Kr/⁸³Kr]c = 0.119–0.185; [22Ne/21Ne]c = 1.083–1.144), in contrast to the observations on lunar samples. As expected considering the method used, ⁸¹Kr-Kr ages calculated either directly with this new P(⁸¹Kr)c/P(⁸³Kr)c value or with our new Y value both agree with the corresponding ³⁶Cl-³⁶Ar ages. However, the average deviation of 2% indicates the accuracy of both new ⁸¹Kr-Kr dating methods and the precision of the new dating systems of ~10% is demonstrated by the low scatter in the data. Consequently, this study indicates that the ⁸¹Kr-Kr ages published so far are up to 30% too high.
Resumo:
Intraoperative laparoscopic calibration remains a challenging task. In this work we present a new method and instrumentation for intraoperative camera calibration. Contrary to conventional calibration methods, the proposed technique allows intraoperative laparoscope calibration from single perspective observations, resulting in a standardized scheme for calibrating in a clinical scenario. Results show an average displacement error of 0.52 ± 0.19 mm, indicating sufficient accuracy for clinical use. Additionally, the proposed method is validated clinically by performing a calibration during the surgery.
Resumo:
Stable isotope analyses of discrete seasonal layers from a 108-yr annually laminated freeze-core from Baldeg-gersee, a small, eutrophic lake in central Switzerland, provide information on the climatological and environmental factors, including lake eutrophication, that control oxygen and carbon isotopic composition of epilimnic biologically induced calcite precipitate. During the last 100 yr, Baldeggersee has undergone major increases in productivity and eutrophication in response to nutrient loading from agriculture and industrialization in the lake's watershed. Calibration of the isotopic signal in Baldeggersee to historical limnological data quantitatively links evidence of isotopic depletion in the sedimented calcite to trophic state of the lake. δ18O values from the spring/summer “light” sediment layers steadily diverged to more depleted values in response to historical eutrophication: measured δ18O values were up to 21.5‰ more negative than calculated equilibrium δ18O values. Evidence for 13C depletion in the calcite, relative to equilibrium values, is more difficult to ascertain because of an overall dominance of isotopic enrichment in the dissolved inorganic pool as productivity in Baldeggersee increases. A positive association exists between the degree of oxygen-18 depletion and the calcite crystal size. Thus, large amorphous calcite grains can be used as a proxy for recognizing apparent isotopic nonequilibrium in sediment sequences from highly productive lacustrine environments from all geologic time scales. In contrast to the light layers, the oxygen isotopic composition of the calcite in the late summer/fall “dark” sediment layers is unaffected by the apparent isotope nonequilibrium. Oxygen and carbon isotope values from the dark laminae in the Baldeggersee sediment therefore provide environmental and climatological proxies that can be calibrated with known environmental and regional climate data for the last century.
Resumo:
High-resolution, small-bore PET systems suffer from a tradeoff between system sensitivity, and image quality degradation. In these systems long crystals allow mispositioning of the line of response due to parallax error and this mispositioning causes resolution blurring, but long crystals are necessary for high system sensitivity. One means to allow long crystals without introducing parallax errors is to determine the depth of interaction (DOI) of the gamma ray interaction within the detector module. While DOI has been investigated previously, newly available solid state photomultipliers (SSPMs) well-suited to PET applications and allow new modules for investigation. Depth of interaction in full modules is a relatively new field, and so even if high performance DOI capable modules were available, the appropriate means to characterize and calibrate the modules are not. This work presents an investigation of DOI capable arrays and techniques for characterizing and calibrating those modules. The methods introduced here accurately and reliably characterize and calibrate energy, timing, and event interaction positioning. Additionally presented is a characterization of the spatial resolution of DOI capable modules and a measurement of DOI effects for different angles between detector modules. These arrays have been built into a prototype PET system that delivers better than 2.0 mm resolution with a single-sided-stopping-power in excess of 95% for 511 keV g's. The noise properties of SSPMs scale with the active area of the detector face, and so the best signal-to-noise ratio is possible with parallel readout of each SSPM photodetector pixel rather than multiplexing signals together. This work additionally investigates several algorithms for improving timing performance using timing information from multiple SSPM pixels when light is distributed among several photodetectors.
Resumo:
A reliable assessment of relevant substance flows is very important for environmental risk assessments and efficiency analysis of measures to reduce or avoid emissions of micropollutants like drugs to water systems. Accordingly, a detailed preparation of monitoring campaigns should include an accuracy check for the sampling configuration to prove the reliability of the monitoring results and the subsequent data processing. The accuracy of substance flow analyses is expected to be particularly weak for substances having high short-term variations of concentrations in sewage. This is especially the case linked to the observation of substance flows close to source in waste water systems. The verification of a monitoring configuration in a hospital sewer in Luxembourg is in the centre of interest of the case study presented here. A tracer test in the sewer system under observation is an essential element of the suggested accuracy check and provides valuable information for an uncertainty analysis. The results illustrate the importance of accuracy checks as an essential element of the preparation of monitoring campaigns. Moreover the study shows that continuous flow proportional sampling enables a representative observation of short-term peak loads of the iodinated x-ray contrast media iobitridol close to source.
Resumo:
The North Atlantic and Norwegian Sea are prominent sinks of atmospheric CO2 today, but their roles in the past remain poorly constrained. In this study, we attempt to use B/Ca and d11B ratios in the planktonic foraminifera Neogloboquadrina pachyderma (sinistral variety) to reconstruct subsurface water pH and pCO2 changes in the polar North Atlantic during the last deglaciation. Comparison of core-top results with nearby hydrographic data shows that B/Ca in N. pachyderma (s) is mainly controlled by seawater [B(OH)4]?/[HCO3]? with a roughly constant partition coefficient (KD =([B/Ca]of CaCO3)/([B(OH)4]-/[HCO3]-)of seawater) of 1.48 ± 0.15 * 10**-3 (2sigma), and d11B in this species is offset below d11B of the borate in seawater by 3.38 ± 0.71 per mil (2sigma). These values represent our best estimates with the sparse available hydrographic data close to our core-tops. More culturing and sediment trap work is needed to improve our understanding of boron incorporation into N. pachyderma (s). Application of a constant KD of 1.48 * 10**-3 to high resolution N. pachyderma (s) B/Ca records from two adjacent cores off Iceland shows that subsurface pCO2 at the habitat depth of N. pachyderma (s) (~50 m) generally followed the atmospheric CO2 trend but with negative offsets of ~10-50 ppmv during 19-10 ka. These B/Ca-based reconstructions are supported by independent estimates from low-resolution d11B measurements in the same cores. We also calibrate and apply Cd/Ca in N. pachyderma (s) to reconstruct nutrient levels for the same down cores. Like today's North Atlantic, past subsurface pCO2 variability off Iceland was significantly correlated with nutrient changes that might be linked to surface nutrient utilization and mixing within the upper water column. Because surface pCO2 (at 0 m water depth) is always lower than at deeper depths and if the application of a constant KD is valid, our results suggest that the polar North Atlantic has remained a CO2 sink during the calcification seasons of N. pachyderma (s) over the last deglaciation.
Resumo:
The relationship between phytoplankton assemblages and the associated optical properties of the water body is important for the further development of algorithms for large-scale remote sensing of phytoplankton biomass and the identification of phytoplankton functional types (PFTs), which are often representative for different biogeochemical export scenarios. Optical in-situ measurements aid in the identification of phytoplankton groups with differing pigment compositions and are widely used to validate remote sensing data. In this study we present results from an interdisciplinary cruise aboard the RV Polarstern along a north-to-south transect in the eastern Atlantic Ocean in November 2008. Phytoplankton community composition was identified using a broad set of in-situ measurements. Water samples from the surface and the depth of maximum chlorophyll concentration were analyzed by high performance liquid chromatography (HPLC), flow cytometry, spectrophotometry and microscopy. Simultaneously, the above- and underwater light field was measured by a set of high spectral resolution (hyperspectral) radiometers. An unsupervised cluster algorithm applied to the measured parameters allowed us to define bio-optical provinces, which we compared to ecological provinces proposed elsewhere in the literature. As could be expected, picophytoplankton was responsible for most of the variability of PFTs in the eastern Atlantic Ocean. Our bio-optical clusters agreed well with established provinces and thus can be used to classify areas of similar biogeography. This method has the potential to become an automated approach where satellite data could be used to identify shifting boundaries of established ecological provinces or to track exceptions from the rule to improve our understanding of the biogeochemical cycles in the ocean.