940 resultados para FORMIC ACID FUEL CELLS
Resumo:
Heterogeneous catalysis, homogeneous catalysis, adsorption equilibrium, reaction kinetics, impulse method, hydrolysis of methyl formate, production of formic acid
Resumo:
Matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) has recently been introduced in diagnostic microbiology laboratories for the identification of bacterial and yeast strains isolated from clinical samples. In the present study, we prospectively compared MALDI-TOF MS to the conventional phenotypic method for the identification of routine isolates. Colonies were analyzed by MALDI-TOF MS either by direct deposition on the target plate or after a formic acid-acetonitrile extraction step if no valid result was initially obtained. Among 1,371 isolates identified by conventional methods, 1,278 (93.2%) were putatively identified to the species level by MALDI-TOF MS and 73 (5.3%) were identified to the genus level, but no reliable identification was obtained for 20 (1.5%). Among the 1,278 isolates identified to the species level by MALDI-TOF MS, 63 (4.9%) discordant results were initially identified. Most discordant results (42/63) were due to systematic database-related taxonomical differences, 14 were explained by poor discrimination of the MALDI-TOF MS spectra obtained, and 7 were due to errors in the initial conventional identification. An extraction step was required to obtain a valid MALDI-TOF MS identification for 25.6% of the 1,278 valid isolates. In conclusion, our results show that MALDI-TOF MS is a fast and reliable technique which has the potential to replace conventional phenotypic identification for most bacterial strains routinely isolated in clinical microbiology laboratories.
Resumo:
Introduction: The general strategy to perform anti-doping analysis starts with a screening followed by a confirmatory step when a sample is suspected to be positive. The screening step should be fast, generic and able to highlight any sample that may contain a prohibited substance by avoiding false negative and reducing false positive results. The confirmatory step is a dedicated procedure comprising a selective sample preparation and detection mode. Aim: The purpose of the study is to develop rapid screening and selective confirmatory strategies to detect and identify 103 doping agents in urine. Methods: For the screening, urine samples were simply diluted by a factor 2 with ultra-pure water and directly injected ("dilute and shoot") in the ultrahigh- pressure liquid chromatography (UHPLC). The UHPLC separation was performed in two gradients (ESI positive and negative) from 5/95 to 95/5% of MeCN/Water containing 0.1% formic acid. The gradient analysis time is 9 min including 3 min reequilibration. Analytes detection was performed in full scan mode on a quadrupole time-of-flight (QTOF) mass spectrometer by acquiring the exact mass of the protonated (ESI positive) or deprotonated (ESI negative) molecular ion. For the confirmatory analysis, urine samples were extracted on SPE 96-well plate with mixed-mode cation (MCX) for basic and neutral compounds or anion exchange (MAX) sorbents for acidic molecules. The analytes were eluted in 3 min (including 1.5 min reequilibration) with a S1-25 Ann Toxicol Anal. 2009; 21(S1) Abstracts gradient from 5/95 to 95/5% of MeCN/Water containing 0.1% formic acid. Analytes confirmation was performed in MS and MS/MS mode on a QTOF mass spectrometer. Results: In the screening and confirmatory analysis, basic and neutral analytes were analysed in the positive ESI mode, whereas acidic compounds were analysed in the negative mode. The analyte identification was based on retention time (tR) and exact mass measurement. "Dilute and shoot" was used as a generic sample treatment in the screening procedure, but matrix effect (e.g., ion suppression) cannot be avoided. However, the sensitivity was sufficient for all analytes to reach the minimal required performance limit (MRPL) required by the World Anti Doping Agency (WADA). To avoid time-consuming confirmatory analysis of false positive samples, a pre-confirmatory step was added. It consists of the sample re-injection, the acquisition of MS/MS spectra and the comparison to reference material. For the confirmatory analysis, urine samples were extracted by SPE allowing a pre-concentration of the analyte. A fast chromatographic separation was developed as a single analyte has to be confirmed. A dedicated QTOF-MS and MS/MS acquisition was performed to acquire within the same run a parallel scanning of two functions. Low collision energy was applied in the first channel to obtain the protonated molecular ion (QTOF-MS), while dedicated collision energy was set in the second channel to obtain fragmented ions (QTOF-MS/MS). Enough identification points were obtained to compare the spectra with reference material and negative urine sample. Finally, the entire process was validated and matrix effects quantified. Conclusion: Thanks to the coupling of UHPLC with the QTOF mass spectrometer, high tR repeatability, sensitivity, mass accuracy and mass resolution over a broad mass range were obtained. The method was sensitive, robust and reliable enough to detect and identify doping agents in urine. Keywords: screening, confirmatory analysis, UHPLC, QTOF, doping agents
Resumo:
Les piles de combustible permeten la transformació eficient de l’energia química de certs combustibles a energia elèctrica a través d’un procés electroquímic. De les diferents tecnologies de piles de combustible, les piles de combustible de tipus PEM són les més competitives i tenen una gran varietat d’aplicacions. No obstant, han de ser alimentades únicament per hidrogen. Per altra banda, l’etanol, un combustible interessant en el marc dels combustibles renovables, és una possible font d’hidrogen. Aquest treball estudia la reformació d’etanol per a l’obtenció d’hidrogen per a alimentar piles de combustible PEM. Només existeixen algunes publicacions que tractin l’obtenció d’hidrogen a partir d’etanol, i aquestes no inclouen l’estudi dinàmic del sistema. Els objectius del treball són el modelat i l’estudi dinàmic de reformadors d’etanol de baixa temperatura. Concretament, proposa un model dinàmic d’un reformador catalític d’etanol amb vapor basat en un catalitzador de cobalt. Aquesta reformació permet obtenir valors alts d’eficiència i valors òptims de monòxid de carboni que evitaran l’enverinament d’una la pila de combustible de tipus PEM. El model, no lineal, es basa en la cinètica obtinguda de diferents assaigs de laboratori. El reformador modelat opera en tres etapes: deshidrogenació d’etanol a acetaldehid i hidrogen, reformat amb vapor d’acetaldehid, i la reacció WGS (Water Gas Shift). El treball també estudia la sensibilitat i controlabilitat del sistema, caracteritzant així el sistema que caldrà controlar. L’anàlisi de controlabilitat es realitza sobre la resposta de dinàmica ràpida obtinguda del balanç de massa del reformador. El model no lineal és linealitzat amb la finalitat d’aplicar eines d’anàlisi com RGA, CN i MRI. El treball ofereix la informació necessària per a avaluar la possible implementació en un laboratori de piles de combustibles PEM alimentades per hidrogen provinent d’un reformador d’etanol.
Resumo:
En este proyecto se tiene como objetivo comparar una EDAR específica con otras tres, desde el punto de vista ambiental, y establecer diferentes alternativas. En particular, se ha evaluado la mejor alternativa en la obtención de energía eléctrica para la propia utilización de la planta de tratamiento de aguas residuales, a partir del biogás generado en el digestor en la línea de lodos. En este tipo de instalaciones, entre las alternativas tanto en su uso actual como en fase de desarrollo, el motor de cogeneración de electricidad y el calor es el más utilizado para obtener simultáneamente la electricidad necesaria para las instalaciones y el calor necesario para mantener el digestor de lodos a la temperatura de trabajo (36ºC aproximadamente). Las otras alternativas evaluadas en este estudio son las pilas de biogás de membrana electrolítica polimérica (en inglés Polymeric Electrolyte Membrane, PEM) y las pilas de óxidos sólidos (en inglés Solid Oxide Fuel Cells, SOFC) con una turbina de gas (sistema híbrido SOFC-GT). Por otro lado, se estudian las características de los materiales que componen los dispositivos MEC (microbial electrolysis cell) y las pilas PEM y SOFC, así como las ventajas e inconvenientes de usar estas nuevas tecnologías en el tratamiento de aguas residuales, así como la evaluación del impacto ambiental de la EDAR objeto de estudio, que se ha llevado a cabo utilizando el análisis de ciclo de vida (ACV). El ACV es una herramienta que permite comparar diferentes procesos o productos que tengan la misma función, y así evaluar la alternativa que conlleve una mejora en el medio ambiental. La metodología de ACV pretende evaluar en detalle el ciclo de vida completo de un producto o proceso. Un ACV se suele definir de tipo "cradle to grave" o "desde la cuna hasta la tumba" o bien de tipo "gate to gate", o "de puerta a puerta". En el primer caso el estudio analiza el ciclo de vida completo del sistema, dese el origen hasta el final, mientras que en el segundo caso el ACV no tiene en cuenta su disposición final (vertedero, reciclaje, etc.). Un estudio de ACV del primer tipo conlleva hacer un estudio muy detallado, que en la práctica puede resultar muy largo y laborioso por la dificultad de encontrar todos los datos necesarios. Por ello, muchos estudios de ACV que se encuentran en la literatura suelen ser del tipo "gate to gate". Además, hay que esablecer las fronteras del sistema a estudiar, ya que hay procesos que tienen muy poca contribución a las categorías de impacto ambiental. En una EDAR los principales procesos considerados en el ACV llevado a cabo son el consumo de productos químicos, de electricidad, la producción de lodos y su utilización como composta, el biogás y su utilización para producir electricidad, los residuos sólidos y las distintas emisiones al medio producidas por el propio funcionamiento de la EDAR. Las operaciones relacionadas indirectamente como el transporte de los lodos, de productos químicos, de los residuos sólidos y la infraestructura con una vida media de 30 años no influyen significativamente en los resultados, por ejemplo el transporte de los lodos con un camión a 30km contribuyen en menos de 1% en todas las categorías de impacto. De acuerdo con las normativas ISO series 14040 que regulan las pautas de un ACV, se establece una unidad funcional apropiada, o sea habitante equivalente, ya que es la más apropiada por tener en cuenta la carga contaminante en el agua a tratar, parámetro imprescindible para comparar EDARs. Redefiniendo las fronteras, se realiza un ACV del depósito del biogás sin tener en cuenta el resto de la instalación y se toma como unidad funcional m3 de biogás, en el caso concreto de obtener biogás mediante un dispositivo MEC, que maximiza la cantidad de hidrógeno en detrimento de la cantidad de metano contenido en el biogás, observándose que la contribución de un biogás con un alto contenido en hidrógeno y, por tanto bajo en metano, produce una mejora ambiental. Las categorías de impacto ambiental que tienen contribución son el calentamiento global y la oxidación fotoquímica; el dispositivo MEC hace quela contribución a estas categorías de impacto sea de un orden de magnitud inferior con respecto al biogás generado en un digestor. Además, si se produce la combustión del biogás, la única categoría de impacto que tiene contribución es la de calentamiento global; para una dispositivo MEC la contribución sigue siendo un orden de magnitud inferior con respecto al biogás de un digestor de lodos.
Resumo:
Growing experimental evidence indicates that, in addition to the physical virion components, the non-structural proteins of hepatitis C virus (HCV) are intimately involved in orchestrating morphogenesis. Since it is dispensable for HCV RNA replication, the non-structural viral protein NS2 is suggested to play a central role in HCV particle assembly. However, despite genetic evidences, we have almost no understanding about NS2 protein-protein interactions and their role in the production of infectious particles. Here, we used co-immunoprecipitation and/or fluorescence resonance energy transfer with fluorescence lifetime imaging microscopy analyses to study the interactions between NS2 and the viroporin p7 and the HCV glycoprotein E2. In addition, we used alanine scanning insertion mutagenesis as well as other mutations in the context of an infectious virus to investigate the functional role of NS2 in HCV assembly. Finally, the subcellular localization of NS2 and several mutants was analyzed by confocal microscopy. Our data demonstrate molecular interactions between NS2 and p7 and E2. Furthermore, we show that, in the context of an infectious virus, NS2 accumulates over time in endoplasmic reticulum-derived dotted structures and colocalizes with both the envelope glycoproteins and components of the replication complex in close proximity to the HCV core protein and lipid droplets, a location that has been shown to be essential for virus assembly. We show that NS2 transmembrane region is crucial for both E2 interaction and subcellular localization. Moreover, specific mutations in core, envelope proteins, p7 and NS5A reported to abolish viral assembly changed the subcellular localization of NS2 protein. Together, these observations indicate that NS2 protein attracts the envelope proteins at the assembly site and it crosstalks with non-structural proteins for virus assembly.
Resumo:
The treatment of some cancer patients has shifted from traditional, non-specific cytotoxic chemotherapy to chronic treatment with molecular targeted therapies. Imatinib mesylate, a selective inhibitor of tyrosine kinases (TKIs) is the most prominent example of this new era and has opened the way to the development of several additional TKIs, including sunitinib, nilotinib, dasatinib, sorafenib and lapatinib, in the treatment of various hematological malignancies and solid tumors. All these agents are characterized by an important inter-individual pharmacokinetic variability, are at risk for drug interactions, and are not devoid of toxicity. Additionally, they are administered for prolonged periods, anticipating the careful monitoring of their plasma exposure via Therapeutic Drug Monitoring (TDM) to be an important component of patients' follow-up. We have developed a liquid chromatography-tandem mass spectrometry method (LC-MS/MS) requiring 100 microL of plasma for the simultaneous determination of the six major TKIs currently in use. Plasma is purified by protein precipitation and the supernatant is diluted in ammonium formate 20 mM (pH 4.0) 1:2. Reverse-phase chromatographic separation of TKIs is obtained using a gradient elution of 20 mM ammonium formate pH 2.2 and acetonitrile containing 1% formic acid, followed by rinsing and re-equilibration to the initial solvent composition up to 20 min. Analyte quantification, using matrix-matched calibration samples, is performed by electro-spray ionization-triple quadrupole mass spectrometry by selected reaction monitoring detection using the positive mode. The method was validated according to FDA recommendations, including assessment of extraction yield, matrix effects variability (<9.6%), overall process efficiency (87.1-104.2%), as well as TKIs short- and long-term stability in plasma. The method is precise (inter-day CV%: 1.3-9.4%), accurate (-9.2 to +9.9%) and sensitive (lower limits of quantification comprised between 1 and 10 ng/mL). This is the first broad-range LC-MS/MS assay covering the major currently in-use TKIs. It is an improvement over previous methods in terms of convenience (a single extraction procedure for six major TKIs, reducing significantly the analytical time), sensitivity, selectivity and throughput. It may contribute to filling the current knowledge gaps in the pharmacokinetics/pharmacodynamics relationships of the latest TKIs developed after imatinib and better define their therapeutic ranges in different patient populations in order to evaluate whether a systematic TDM-guided dose adjustment of these anticancer drugs could contribute to minimize the risk of major adverse reactions and to increase the probability of efficient, long lasting, therapeutic response.
Resumo:
The Eukaryotic Promoter Database (EPD) is an annotated non-redundant collection of eukaryotic POL II promoters, experimentally defined by a transcription start site (TSS). There may be multiple promoter entries for a single gene. The underlying experimental evidence comes from journal articles and, starting from release 73, from 5' ESTs of full-length cDNA clones used for so-called in silico primer extension. Access to promoter sequences is provided by pointers to TSS positions in nucleotide sequence entries. The annotation part of an EPD entry includes a description of the type and source of the initiation site mapping data, links to other biological databases and bibliographic references. EPD is structured in a way that facilitates dynamic extraction of biologically meaningful promoter subsets for comparative sequence analysis. Web-based interfaces have been developed that enable the user to view EPD entries in different formats, to select and extract promoter sequences according to a variety of criteria and to navigate to related databases exploiting different cross-references. Tools for analysing sequence motifs around TSSs defined in EPD are provided by the signal search analysis server. EPD can be accessed at http://www.epd. isb-sib.ch.
Resumo:
The aim of our study was to provide an innovative headspace-gas chromatography-mass spectrometry (HS-GC-MS) method applicable for the routine determination of blood CO concentration in forensic toxicology laboratories. The main drawback of the GC/MS methods discussed in literature for CO measurement is the absence of a specific CO internal standard necessary for performing quantification. Even if stable isotope of CO is commercially available in the gaseous state, it is essential to develop a safer method to limit the manipulation of gaseous CO and to precisely control the injected amount of CO for spiking and calibration. To avoid the manipulation of a stable isotope-labeled gas, we have chosen to generate in a vial in situ, an internal labeled standard gas ((13)CO) formed by the reaction of labeled formic acid formic acid (H(13)COOH) with sulfuric acid. As sulfuric acid can also be employed to liberate the CO reagent from whole blood, the procedure allows for the liberation of CO simultaneously with the generation of (13)CO. This method allows for precise measurement of blood CO concentrations from a small amount of blood (10 μL). Finally, this method was applied to measure the CO concentration of intoxicated human blood samples from autopsies.
Resumo:
INTRODUCTION: The analysis of glucosinolates (GS) is traditionally performed by reverse-phase liquid chromatography coupled to ultraviolet detection after a time-consuming desulphation step, which is required for increased retention. Simpler and more efficient alternative methods that can shorten both sample preparation and analysis are much needed. OBJECTIVE: To evaluate the feasibility of using ultrahigh-pressure liquid chromatography coupled to quadrupole time-of-flight mass spectrometry (UHPLC-QTOFMS) for the rapid profiling of intact GS. METHODOLOGY: A simple and short extraction of GS from Arabidopsis thaliana leaves was developed. Four sub-2 µm reverse-phase columns were tested for the rapid separation of these polar compounds using formic acid as the chromatographic additive. High-resolution QTOFMS was used to detect and identify GS. RESULTS: A novel charged surface hybrid (CSH) column was found to provide excellent retention and separation of GS within a total running time of 11 min. Twenty-one GS could be identified based on their accurate mass as well as isotopic and fragmentation patterns. The method was applied to determine the changes in GS content that occur after herbivory in Arabidopsis. In addition, we evaluated its applicability to the profiling of other Brassicaceae species. CONCLUSION: The method developed can profile the full range of GS, including the most polar ones, in a shorter time than previous methods, and is highly compatible with mass spectrometric detection.
Resumo:
A simple wipe sampling procedure was developed for the surface contamination determination of ten cytotoxic drugs: cytarabine, gemcitabine, methotrexate, etoposide phosphate, cyclophosphamide, ifosfamide, irinotecan, doxorubicin, epirubicin and vincristine. Wiping was performed using Whatman filter paper on different surfaces such as stainless steel, polypropylene, polystyrol, glass, latex gloves, computer mouse and coated paperboard. Wiping and desorption procedures were investigated: The same solution containing 20% acetonitrile and 0.1% formic acid in water gave the best results. After ultrasonic desorption and then centrifugation, samples were analysed by a validated liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS) in selected reaction monitoring mode. The whole analytical strategy from wipe sampling to LC-MS/MS analysis was evaluated to determine quantitative performance. The lowest limit of quantification of 10 ng per wiping sample (i.e. 0.1 ng cm(-2)) was determined for the ten investigated cytotoxic drugs. Relative standard deviation for intermediate precision was always inferior to 20%. As recovery was dependent on the tested surface for each drug, a correction factor was determined and applied for real samples. The method was then successfully applied at the cytotoxic production unit of the Geneva University Hospitals pharmacy.
Resumo:
There is increasing evidence that the clinical efficacy of tamoxifen, the first and most widely used targeted therapy for estrogen-sensitive breast cancer, depends on the formation of the active metabolites 4-hydroxy-tamoxifen and 4-hydroxy-N-desmethyl-tamoxifen (endoxifen). Large inter-individual variability in endoxifen plasma concentrations has been observed and related both to genetic and environmental (i.e. drug-induced) factors altering CYP450s metabolizing enzymes activity. In this context, we have developed an ultra performance liquid chromatography-tandem mass spectrometry method (UPLC-MS/MS) requiring 100 μL of plasma for the quantification of tamoxifen and three of its major metabolites in breast cancer patients. Plasma is purified by a combination of protein precipitation, evaporation at room temperature under nitrogen, and reconstitution in methanol/20 mM ammonium formate 1:1 (v/v), adjusted to pH 2.9 with formic acid. Reverse-phase chromatographic separation of tamoxifen, N-desmethyl-tamoxifen, 4-hydroxy-tamoxifen and 4-hydroxy-N-desmethyl-tamoxifen is performed within 13 min using elution with a gradient of 10 mM ammonium formate and acetonitrile, both containing 0.1% formic acid. Analytes quantification, using matrix-matched calibration samples spiked with their respective deuterated internal standards, is performed by electrospray ionization-triple quadrupole mass spectrometry using selected reaction monitoring detection in the positive mode. The method was validated according to FDA recommendations, including assessment of relative matrix effects variability, as well as tamoxifen and metabolites short-term stability in plasma and whole blood. The method is precise (inter-day CV%: 2.5-7.8%), accurate (-1.4 to +5.8%) and sensitive (lower limits of quantification comprised between 0.4 and 2.0 ng/mL). Application of this method to patients' samples has made possible the identification of two further metabolites, 4'-hydroxy-tamoxifen and 4'-hydroxy-N-desmethyl-tamoxifen, described for the first time in breast cancer patients. This UPLC-MS/MS assay is currently applied for monitoring plasma levels of tamoxifen and its metabolites in breast cancer patients within the frame of a clinical trial aiming to assess the impact of dose increase on tamoxifen and endoxifen exposure.
Resumo:
Inflammation is a local immune response to 'foreign' molecules, infection and injury. Leukotriene B4, a potent chemotactic agent that initiates, coordinates, sustains and amplifies the inflammatory response, is shown to be an activating ligand for the transcription factor PPARalpha. Because PPARalpha regulates the oxidative degradation of fatty acids and their derivatives, like this lipid mediator, a feedback mechanism is proposed that controls the duration of an inflammatory response and the clearance of leukotriene B4 in the liver. Thus PPARalpha offers a new route to the development of anti- or pro-inflammatory reagents.
Intra-puparial development of the females of Chrysomya albiceps (Wiedemann) (Diptera, Calliphoridae)
Resumo:
Intra-puparial development of the females of Chrysomya albiceps (Wiedemann) (Diptera, Calliphoridae). The chronology and morphological changes that take place during intra-puparial development of Chrysomya albiceps is described based on 254 specimens reared in the laboratory. Larvae were obtained from the eggs laid by a single female. The pre-pupae were separated according to the reduction of larval length and the degree of pigmentation and sclerotization of the cuticle. After pupation, 10 individuals were fixed in Carnoy's solution and preserved in 70% ethanol, 10 individuals were fixed every 3 hours up to complete the first 24 hours (n = 80), the remaining individuals were fixed every six hours up to the 90th hour (n = 110) when 54 females emerged. The pupae were immersed in 5% formic acid for 48 hours and maintained in 70% ethanol, and then dissected and analyzed. C. albiceps shows four intra-puparial stages, each of which were described and compared with those described for Musca domestica, Calliphora erythrocephala, Sarcophaga bullata, Cuterebra tenebrosa, Oestrus ovis and Dermatobia hominis. Four developmental stages may be described: (1) the larva-pupa apolysis, after three hours; (2) the criptocephalic pupa, after six hours; (3) the phanerocephalic pupa, after nine hours; (4) the pharate pupa, after nine hours. The pharate adult is completely formed after 81 hours.
Resumo:
The relaxivity of commercially available gadolinium (Gd)-based contrast agents was studied for X-nuclei resonances with long intrinsic relaxation times ranging from 6 s to several hundred seconds. Omniscan in pure 13C formic acid had a relaxivity of 2.9 mM(-1) s(-1), whereas its relaxivity on glutamate C1 and C5 in aqueous solution was approximately 0.5 mM(-1) s(-1). Both relaxivities allow the preparation of solutions with a predetermined short T1 and suggest that in vitro substantial sensitivity gains in their measurement can be achieved. 6Li has a long intrinsic relaxation time, on the order of several minutes, which was strongly affected by the contrast agents. Relaxivity ranged from approximately 0.1 mM(-1) s(-1) for Omniscan to 0.3 for Magnevist, whereas the relaxivity of Gd-DOTP was at 11 mM(-1) s(-1), which is two orders of magnitude higher. Overall, these experiments suggest that the presence of 0.1- to 10-microM contrast agents should be detectable, provided sufficient sensitivity is available, such as that afforded by hyperpolarization, recently introduced to in vivo imaging.