992 resultados para External parameters
Resumo:
A copper(II) chiral aza-bis(oxazoline) homogeneous catalyst (CuazaBox) was anchored onto the external surface of MCM-22 and ITQ-2 structures, as well as encapsulated into hierarchical MCM-22. The transition metal complex loading onto the porous solids was determined by ICP-AES and the materials were also characterized by elemental analysis (C, N, H, S), FTIR, XPS, TG and low temperature N-2 adsorption isotherms. The materials were tested as heterogeneous catalysts in the benchmark reaction of cyclopropanation of styrene to check the effect of the immobilization procedure on the catalytic parameters, as well as on their reutilization in several catalytic cycles. Catalyst CuazaBox anchored onto the external surface of MCM-22 and ITQ-2 materials were more active and enantioselective in the cyclopropanation of styrene than the corresponding homogeneous phase reaction run under similar experimental conditions. This is due to the propylation of the acidic aza-Box nitrogen. HMCM-22 was nevertheless the best heterogeneous catalyst. Encapsulation of CuazaBox on post-synthesis modified MCM-22 materials led to low activities and enantioselectivities. But reversal on the stereochemical course of the reaction was observed, probably due to confinement effect. (C) 2013 Elsevier Inc. All rights reserved.
Resumo:
Este estudo pretendeu reproduzir uma tarefa da vida diária (marcha com transporte de peso nos membros superiores) realizada de forma rotineira e até aconselhada no contexto da prevenção e reabilitação de patologia cardiovascular, desta forma, teve como objectivo avaliar o efeito agudo de uma sessão de exercício aeróbio associado a exercício isométrico na rigidez arterial em indivíduos jovens. Foram recrutados 14 indivíduos do sexo masculino com média de idade de 30,3±3,6 anos. Foram realizadas duas sessões de exercício com uma semana de intervalo. Em ambas as sessões de exercício, os sujeitos caminharam num tapete rolante a uma velocidade de 5,0 km/h por um período de dez minutos, sendo que, numa das sessões, determinada aleatoriamente, carregaram o equivalente a 10% do seu peso corporal distribuído igualmente pelos dois membros superiores em dois garrafões de água. Avaliou-se em repouso e imediatamente após o exercício, a pressão arterial periférica, a frequência cardíaca e a rigidez arterial. A análise da rigidez arterial foi efectuada na artéria radial do membro superior direito com um sistema transdutor automático de pressão. Os parâmetros reportados neste estudo são a frequência cardíaca, a pressão arterial sistólica e diastólica, a pressão arterial média, a pressão central (aórtica) sistólica, a pressão de pulso central, a pressão de aumentação e o índice de aumentação a 75 bmp (Aix@75). Em repouso, não se verificaram diferenças significativas entre as duas sessões de exercício nos parâmetros avaliados. O principal resultado do presente estudo indica que a rigidez arterial aumenta de forma aguda com a realização de caminhada (exercício aeróbio) apenas quando esta é acompanhada do transporte nos membros superiores de uma carga externa (exercício isométrico) [Aix@75: -5.5(8.4) para -1.36(8.17)%, p<0.05]. Relativamente ao protocolo exclusivamente aeróbio não se verificaram diferenças significativas na rigidez arterial [Aix@75: -4.2(9.1) para -4.69(7.93)%, p>0.05]. Em conclusão, os resultados do presente estudo indicam que a rigidez arterial, em indivíduos jovens e aparentemente saudáveis, aumenta de forma significativa apenas quando o exercício aeróbio é acompanhado de exercício isométrico de membros superiores com transporte de carga adicional.
Resumo:
Introdução: Embora existam estratégias para coordenar as funções postural e ventilatória numa situação normal, isto pode não ser verdade quando a necessidade para uma das funções está aumentada, como por exemplo em patologia respiratória (asma) ou no exercício físico, em que subsistem maiores necessidades ventilatórias. O método Pilates, que foca a relação entre o corpo e a disciplina mental, visa prosperar a saúde e o bem-estar pelo enfatizar da boa postura, do alinhamento corporal e da coordenação da ventilação com o movimento. Objectivo: Comparar características de controlo motor e parâmetros ventilatórios em asmáticos controlados e indivíduos sem patologia, e verificar o efeito de um programa de exercícios segundo Pilates nesses outcomes em indivíduos com asma controlada. Métodos: Estudo quasi-experimental, com uma amostra constituída por 21 estudantes voluntários, 7 pertencentes ao “grupo sem patologia”, 7 ao “grupo controlo asmático” e 7 ao “grupo experimental asmático”. Para avaliação do timing de ativação e do padrão de recrutamento muscular no movimento rápido do membro superior foi utilizada eletromiografia de superfície do Diafragma, Eretor da Coluna, Multífidos, Oblíquo Externo, Reto Anterior e Transverso Abdominal/Oblíquo Interno. Foram também avaliados parâmetros de função ventilatória: a percentagem de volume expiratório forçado no primeiro segundo do previsto, o débito expiratório máximo instantâneo, a ventilação máxima voluntária, a pressão inspiratória máxima e a pressão expiratória máxima. As avaliações decorreram antes e após 8 semanas da aplicação de um programa de exercícios segundo Pilates no grupo experimental asmático, com exceção do grupo sem patologia que realizou apenas o primeiro momento de avaliação. Resultados: O grupo controlo asmático apresentou um timing de ativação significativamente maior do Transverso Abdominal/Oblíquo Interno e do Diafragma, em relação ao grupo sem patologia. Nos parâmetros ventilatórios, o grupo controlo asmático apresentou menores valores de percentagem de volume expiratório no primeiro segundo do previsto, de débito expiratório máximo instantâneo e de pressão expiratória máxima. Após a realização do programa de exercícios segundo Pilates verificaram-se alterações significativas no timing de activação do Eretor da Coluna, do Multífidos, do Transverso/Oblíquo Interno e do Diafragma, tendo ambos diminuído no grupo experimental asmático. Ainda, o grupo experimental asmático, em relação aos parâmetros ventilatórios, apresentou diferenças significativas no débito expiratório máximo instantâneo, na ventilação máxima voluntária e na pressão expiratória máxima, tendo ambos aumentado estes valores. Conclusão: Os asmáticos controlados parecem possuir características de controlo motor, especificamente no timing de ativação, e valores de parâmetros ventilatórios diferentes em comparação aos indivíduos sem patologia. O programa de exercícios segundo Pilates, implementado no grupo experimental asmático, parece ter influenciado positivamente esses outcomes.
Resumo:
Multiclass analysis method was optimized in order to analyze pesticides traces by gas chromatography with ion-trap and tandem mass spectrometry (GC-MS/MS). The influence of some analytical parameters on pesticide signal response was explored. Five ion trap mass spectrometry (IT-MS) operating parameters, including isolation time (IT), excitation voltage (EV), excitation time (ET),maximum excitation energy or “q” value (q), and isolationmass window (IMW) were numerically tested in order to maximize the instrument analytical signal response. For this, multiple linear regression was used in data analysis to evaluate the influence of the five parameters on the analytical response in the ion trap mass spectrometer and to predict its response. The assessment of the five parameters based on the regression equations substantially increased the sensitivity of IT-MS/MS in the MS/MS mode. The results obtained show that for most of the pesticides, these parameters have a strong influence on both signal response and detection limit.Using the optimized method, a multiclass pesticide analysis was performed for 46 pesticides in a strawberry matrix. Levels higher than the limit established for strawberries by the European Union were found in some samples.
Resumo:
No trabalho realizado nesta tese, procedeu-se ao estudo hidrodinâmico de uma
coluna de borbulhamento de recirculação externa do líquido (CREL), que permitiu ampliar o
conhecimento já existente sobre este tipo de colunas. Para realizar este estudo utilizaram-se
líquidos viscosos Newtonianos, nomeadamente soluções aquosas de glicerina com
viscosidades entre 0,007 e 0,522 Pa.s. Para a gama de caudais de ar injectados, 1,5x10-5
até 1,35x10-4 m3/s, o ar ascendia ao longo da coluna de borbulhamento sob a forma de
bolhas tubulares. Após a realização dos ensaios, verificou-se que o regime de escoamento
do líquido entre bolhas tubulares variou desde o tipo laminar até transição (1,9
Resumo:
Trabalho Final de Mestrado para obtenção do grau de Mestre em Engenharia Área de Especialização em Vias de Comunicação e Transportes
Resumo:
Conferência: 2nd Experiment at International Conference - 18-20 September 2013
Resumo:
Resumo I (Prática Pedagógica) - Nesta seção do relatório de estágio pretende-se caraterizar e apresentar todos os elementos referentes à prática pedagógica, que fizeram parte do estágio do ensino especializado da música, realizado na Escola de Música do Orfeão de Leiria no ano letivo de 2013/2014. De uma forma geral, o relatório de estágio pretende colocar em evidência aspetos pedagógicos como metodologias de ensino, questões motivacionais, estilos de aprendizagem, entre outros. Durante um ano letivo completo foram analisados, com especial atenção, três alunos que foram envolvidos no estágio, construindo e modelando os seus processos de aprendizagem. Para cada um deles foi realizado, ao longo do ano letivo, 30 planos de aula, uma planificação anual e três gravações vídeo/áudio em contexto de aula. Não foi uma tarefa nada fácil de realizar, mas que trouxe inúmeros conhecimentos não só de caráter pedagógico mas também de caráter pessoal. A parte inicial desta seção será dedicada à descrição e caraterização da escola onde foi realizado o estágio, a Escola de Música do Orfeão de Leiria/Conservatório de Artes. Será feita uma pequena abordagem histórica da instituição, bem como do seu projeto educativo, dacomunidade escolar, do seu contexto sociocultural e da classe de saxofone. Será apresentada também uma caraterização dos alunos, segundo vários parâmetros. Posteriormente, serão descritas algumas das práticas educativas desenvolvidas, com os alunos, em contexto de estágio. Para tal, serão utilizados como instrumentos, não só a experiência ativa do docente/estagiário, mas também todas as gravações, planos de aulas e planificações anuais, realizados em contexto de estágio do ensino especializado. Por fim, será realizada uma reflexão crítica do desempenho como docente de saxofone no âmbito do estágio e uma conclusão de toda a seção da prática pedagógica.
Resumo:
Myocardial Perfusion Gated Single Photon Emission Tomography (Gated-SPET) imaging is used for the combined evaluation of myocardial perfusion and left ventricular (LV). The purpose of this study is to evaluate the influence of the total number of counts acquired from myocardium, in the calculation of myocardial functional parameters using routine software procedures. Methods: Gated-SPET studies were simulated using Monte Carlo GATE package and NURBS phantom. Simulated data were reconstructed and processed using the commercial software package Quantitative Gated-SPECT. The Bland-Altman and Mann-Whitney-Wilcoxon tests were used to analyze the influence of the number of total counts in the calculation of LV myocardium functional parameters. Results: In studies simulated with 3MBq in the myocardium there were significant differences in the functional parameters: Left ventricular ejection fraction (LVEF), end-systolic volume (ESV), Motility and Thickness; between studies acquired with 15s/projection and 30s/projection. Simulations with 4.2MBq show significant differences in LVEF, end-diastolic volume (EDV) and Thickness. Meanwhile in the simulations with 5.4MBq and 8.4MBq the differences were statistically significant for Motility and Thickness. Conclusion: The total number of counts per simulation doesn't significantly interfere with the determination of Gated-SPET functional parameters using the administered average activity of 450MBq to 5.4MBq in myocardium.
Resumo:
The main purpose of this work is to present and to interpret the change of structure and physical properties of tantalum oxynitride (TaNxOy) thin films, produced by dc reactive magnetron sputtering, by varying the processing parameters. A set of TaNxOy films was prepared by varying the reactive gases flow rate, using a N2/O2 gas mixture with a concentration ratio of 17:3. The different films, obtained by this process, exhibited significant differences. The obtained composition and the interpretation of X-ray diffraction results, shows that, depending on the partial pressure of the reactive gases, the films are: essentially dark grey metallic, when the atomic ratio (N + O)/Ta < 0.1, evidencing a tetragonal β-Ta structure; grey-brownish, when 0.1 < (N + O)/Ta < 1, exhibiting a face-centred cubic (fcc) TaN-like structure; and transparent oxide-type, when (N + O)/Ta > 1, evidencing the existence of Ta2O5, but with an amorphous structure. These transparent films exhibit refractive indexes, in the visible region, always higher than 2.0. The wear resistance of the films is relatively good. The best behaviour was obtained for the films with (N + O)/Ta ≈ 0.5 and (N + O)/Ta ≈ 1.3.
Resumo:
The MCNPX code was used to calculate the TG-43U1 recommended parameters in water and prostate tissue in order to quantify the dosimetric impact in 30 patients treated with (125)I prostate implants when replacing the TG-43U1 formalism parameters calculated in water by a prostate-like medium in the planning system (PS) and to evaluate the uncertainties associated with Monte Carlo (MC) calculations. The prostate density was obtained from the CT of 100 patients with prostate cancer. The deviations between our results for water and the TG-43U1 consensus dataset values were -2.6% for prostate V100, -13.0% for V150, and -5.8% for D90; -2.0% for rectum V100, and -5.1% for D0.1; -5.0% for urethra D10, and -5.1% for D30. The same differences between our water and prostate results were all under 0.3%. Uncertainties estimations were up to 2.9% for the gL(r) function, 13.4% for the F(r,θ) function and 7.0% for Λ, mainly due to seed geometry uncertainties. Uncertainties in extracting the TG-43U1 parameters in the MC simulations as well as in the literature comparison are of the same order of magnitude as the differences between dose distributions computed for water and prostate-like medium. The selection of the parameters for the PS should be done carefully, as it may considerably affect the dose distributions. The seeds internal geometry uncertainties are a major limiting factor in the MC parameters deduction.
Resumo:
This paper focuses on a novel formalization for assessing the five parameter modeling of a photovoltaic cell. An optimization procedure is used as a feasibility problem to find the parameters tuned at the open circuit, maximum power, and short circuit points in order to assess the data needed for plotting the I-V curve. A comparison with experimental results is presented for two monocrystalline PV modules.
Resumo:
The discovery of X-rays was undoubtedly one of the greatest stimulus for improving the efficiency in the provision of healthcare services. The ability to view, non-invasively, inside the human body has greatly facilitated the work of professionals in diagnosis of diseases. The exclusive focus on image quality (IQ), without understanding how they are obtained, affect negatively the efficiency in diagnostic radiology. The equilibrium between the benefits and the risks are often forgotten. It is necessary to adopt optimization strategies to maximize the benefits (image quality) and minimize risk (dose to the patient) in radiological facilities. In radiology, the implementation of optimization strategies involves an understanding of images acquisition process. When a radiographer adopts a certain value of a parameter (tube potential [kVp], tube current-exposure time product [mAs] or additional filtration), it is essential to know its meaning and impact of their variation in dose and image quality. Without this, any optimization strategy will be a failure. Worldwide, data show that use of x-rays has been increasingly frequent. In Cabo Verde, we note an effort by healthcare institutions (e.g. Ministry of Health) in equipping radiological facilities and the recent installation of a telemedicine system requires purchase of new radiological equipment. In addition, the transition from screen-films to digital systems is characterized by a raise in patient exposure. Given that this transition is slower in less developed countries, as is the case of Cabo Verde, the need to adopt optimization strategies becomes increasingly necessary. This study was conducted as an attempt to answer that need. Although this work is about objective evaluation of image quality, and in medical practice the evaluation is usually subjective (visual evaluation of images by radiographer / radiologist), studies reported a correlation between these two types of evaluation (objective and subjective) [5-7] which accredits for conducting such studies. The purpose of this study is to evaluate the effect of exposure parameters (kVp and mAs) when using additional Cooper (Cu) filtration in dose and image quality in a Computed Radiography system.
Resumo:
Myocardial perfusion gated-single photon emission computed tomography (gated-SPECT) imaging is used for the combined evaluation of myocardial perfusion and left ventricular (LV) function. The aim of this study is to analyze the influence of counts/pixel and concomitantly the total counts in the myocardium for the calculation of myocardial functional parameters. Material and methods: Gated-SPECT studies were performed using a Monte Carlo GATE simulation package and the NCAT phantom. The simulations of these studies use the radiopharmaceutical 99mTc-labeled tracers (250, 350, 450 and 680MBq) for standard patient types, effectively corresponding to the following activities of myocardium: 3, 4.2, 5.4-8.2MBq. All studies were simulated using 15 and 30s/projection. The simulated data were reconstructed and processed by quantitative-gated-SPECT software, and the analysis of functional parameters in gated-SPECT images was done by using Bland-Altman test and Mann-Whitney-Wilcoxon test. Results: In studies simulated using different times (15 and 30s/projection), it was noted that for the activities for full body: 250 and 350MBq, there were statistically significant differences in parameters Motility and Thickness. For the left ventricular ejection fraction (LVEF), end-systolic volume (ESV) it was only for 250MBq, and 350MBq in the end-diastolic volume (EDV), while the simulated studies with 450 and 680MBq showed no statistically significant differences for global functional parameters: LVEF, EDV and ESV. Conclusion: The number of counts/pixel and, concomitantly, the total counts per simulation do not significantly interfere with the determination of gated-SPECT functional parameters, when using the administered average activity of 450MBq, corresponding to the 5.4MBq of the myocardium, for standard patient types.
Resumo:
In this work, an experimental study was performed on the influence of plug-filling, loading rate and temperature on the tensile strength of single-strap (SS) and double-strap (DS) repairs on aluminium structures. Whilst the main purpose of this work was to evaluate the feasibility of plug-filling for the strength improvement of these repairs, a parallel study was carried out to assess the sensitivity of the adhesive to external features that can affect the repairs performance, such as the rate of loading and environmental temperature. The experimental programme included repairs with different values of overlap length (L O = 10, 20 and 30 mm), and with and without plug-filling, whose results were interpreted in light of experimental evidence of the fracture modes and typical stress distributions for bonded repairs. The influence of the testing speed on the repairs strength was also addressed (considering 0.5, 5 and 25 mm/min). Accounting for the temperature effects, tests were carried out at room temperature (≈23°C), 50 and 80°C. This permitted a comparative evaluation of the adhesive tested below and above the glass transition temperature (T g), established by the manufacturer as 67°C. The combined influence of these two parameters on the repairs strength was also analysed. According to the results obtained from this work, design guidelines for repairing aluminium structures were