970 resultados para Evaluation System


Relevância:

40.00% 40.00%

Publicador:

Resumo:

This study evaluates the influence of different cartographic representations of in-car navigation systems on visual demand, subjective preference, and navigational error. It takes into account the type and complexity of the representation, maneuvering complexity, road layout, and driver gender. A group of 28 drivers (14 male and 14 female) participated in this experiment which was performed in a low-cost driving simulator. The tests were performed on a limited number of instances for each type of representation, and their purpose was to carry out a preliminary assessment and provide future avenues for further studies. Data collected for the visual demand study were analyzed using non-parametric statistical analyses. Results confirmed previous research that showed that different levels of design complexity significantly influence visual demand. Non-grid-like road networks, for example, influence significantly visual demand and navigational error. An analysis of simple maneuvers on a grid-like road network showed that static and blinking arrows did not present significant differences. From the set of representations analyzed to assess visual demand, both arrows were equally efficient. From a gender perspective, women seem to took at the display more than men, but this factor was not significant. With respect to subjective preferences, drivers prefer representations with mimetic landmarks when they perform straight-ahead tasks. For maneuvering tasks, landmarks in a perspective model created higher visual demands.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Much has been researched and discussed in the importance played by knowledge in organizations. We are witnessing the establishment of the knowledge economy, but this "new economy" brings in itself a whole complex system of metrics and evaluations, and cannot be dissociated from it. Due to its importance, the initiatives of knowledge management must be continually assessed on their progress in order to verify whether they are moving towards achieving the goals of success. Thus, good measurement practices should include not only how the organization quantifies its knowledge capital, but also how resources are allocated to supply their growth. Thinking about the aspects listed above, this paper presents an approach to a model for Knowledge extraction using an ERP system, suggesting the establishment of a set of indicators for assessing organizational performance. The objective is to evaluate the implementation of projects of knowledge management and thus observe the general development of the organization.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

In order to provide a low cost system of thermal comfort, a common model of home fan, 40 cm diameter size, had its manual four-button control system replaced by an automatic speed control. The new control system has a temperature sensor feeding a microcontroller that, by using an optic coupling, DIAC or TRIAC-based circuit, varies the RMS value of the fan motor input voltage and its speed, according to the room temperature. Over a wide range of velocity, the fan net power and the motor fan input power were measured working under both control system. The temperature of the motor stator and the voltage waveforms were observed too. Measured values analysis showed that the TRIAC-based control system makes the fan motor work at a very low power factor and efficiency values. The worst case is at low velocity range where the higher fan motor stator temperatures were registered. The poor power factor and efficiency and the harmonics signals inserted in the motor input voltage wave by the TRIAC commutation procedure are correlated.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The hydrodynamic characterization and the performance evaluation of an aerobic three phase fluidized bed reactor in wastewater fish culture treatment are presented in this report. The objective of this study was to evaluate the organic matter, nitrogen and phosphorous removal efficiency in a physical and biological wastewater treatment system of an intensive Nile Tilapia laboratory production with recirculation. The treatment system comprised of a conventional sedimentation basin operated at a hydraulic detention time HDT of 2.94 h and an aerobic three phase airlift fluidized bed reactor AAFBR operated at an 11.9 min HDT. Granular activated carbon was used as support media with density of 1.64 g/cm(3) and effective size of 0.34 mm in an 80 g/L constant concentration. Mean removal efficiencies of BOD, COD, phosphorous, total ammonia nitrogen and total nitrogen were 47%, 77%, 38%, 27% and 24%, respectively. The evaluated system proved an effective alternative for water reuse in the recirculation system capable of maintaining water quality characteristics within the recommended values for fish farming and met the Brazilian standards for final effluent discharges with exception of phosphorous values. (C) 2011 Elsevier B.V. All rights reserved.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Neste trabalho é analisada a aplicação de algoritmos heurísticos para o Modelo Híbrido Linear - Hybrid Linear Model (HLM) - no problema de planejamento da expansão de sistemas de transmissão. O HLM é um modelo relaxado que ainda não foi suficientemente explorado. Assim, é realizada uma análise das características do modelo matemático e das técnicas de solução que podem ser usadas para resolver este tipo de modelo. O trabalho analisa em detalhes um algoritmo heurístico construtivo para o HLM e faz uma extensão da modelagem e da técnica de solução para o planejamento multi-estágio da expansão de sistemas de transmissão. Dentro deste contexto, também é realizada uma avaliação da qualidade das soluções encontradas pelo HLM e as possibilidades de aplicação deste modelo em planejamento de sistemas de transmissão. Finalmente, são apresentados testes com sistemas conhecidos na literatura especializada.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Since 2004, Brazil has been the leading exporter of chicken. Because of the importance of this sector in the Brazilian economy, food safety must be ensured by control and monitoring of the production stages susceptible to contamination, such as the chilling process. The goal of this study was to evaluate changes in microbial levels on chicken carcasses and in chilling water after immersion in a chilling system for 8 and 16 h during commercial processing. An objective of the study was to encourage discussion regarding the Brazilian Ministry of Agriculture Livestock and Food Supply regulation that requires chicken processors to completely empty, clean, and disinfect each tank of the chilling system after every 8-h shift. Before and after immersion carcasses were collected and analyzed for mesophilic bacteria, Enterobacteriaceae, conforms, and Escherichia coli. Samples of water from the chilling system were also analyzed for residual free chlorine. The results do not support required emptying of the chiller tank after 8 h; these tanks could be emptied after 16 h. The results for all carcasses tested at the 8- and 16-h time points indicated no significant differences in the microbiological indicators evaluated. These data provide both technical and scientific support for discussing changes in federal law regarding the management of immersion chilling water systems used as part of the poultry processing line.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Purpose: To analyze the smear layer and the hybrid layer in noncarious and carious dentin prepared by different cutting instruments and restored with composite resin. Study design: Cavities were randomly prepared in 160 specimens (noncarious and artificial carious dentin) by high-speed diamond tips (KG Sorensen 1013), air abrasion system (Prepstart, Danville Engineering), ultrasonic tip (CVDentus 8.3231-1), and ultrasonic tip associated with ultrasonic cavitation by water for 10 s. Half of the cavities in each group were conditioned with 37% phosphoric acid for 15 s. The amount of smear layer and dentinal tubules present were analyzed using scanning electron microscopy and graded from 0 to 3. Cavities were prepared in another 20 noncarious specimens and 20 carious specimens and restored with adhesive composite resin system. The restorations were hemisected longitudinally and analyzed using scanning electron microscopy to evaluate the hybrid layer and resinous prolongation characteristics, using scores ranging from 1 to 6. Results: The data were statistically analyzed using Kruskal-Wallis and Dunn tests at 5% of significance level. There was evidence that the most efficient smear layer removal was the acid etching in the noncarious dentin and the water ultrasonic cavitation in the carious dentin. The hybrid layer formed on the noncarious and carious dentin prepared by the ultrasonic tip was more regular than in the specimens prepared by high-speed diamond tip, with many resinous prolongations. Conclusion: The ultrasonic tip seems to be a promising tool for carious dentin cavity preparation. Microsc. Res. Tech. 73:597-605, 2010. (C) 2009 Wiley-Liss, Inc.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Aim To analyse the thermoplasticity of several endodontic filling materials using the Obtura II System at different temperature settings.Methodology The following materials based on gutta-percha: Regular Obtura (OBT), Obtura Flow 150 (OBT F), Endo Flow (EDF), Odous (ODO) and the synthetic thermoplastic polymer material Resilon (RE) were heated using the Obtura II System at three temperature settings (140, 170 and 200 degrees C). Samples of the heated materials were placed on the sensor of a digital thermometer (THR-140; Instrutherm, São Paulo, Brazil) to determine their real temperature (RT) when the system was set at 140 degrees C (from 64.5 to 69 degrees C), 170 degrees C (from 73.8 to 77.5 degrees C) and 200 degrees C (from 83.6 degrees C for EDF and 100 degrees C for RE). Specimens (n = 30) were made by placing samples of each material in metallic ring moulds and compressing them between two glass slabs. After 24 h, specimens (n = 10) were heated at the different settings (RT) and submitted to compression under a 5-kg load. Plasticization was assessed by calculating the differences between the post-compression and initial diameters of each specimen. Data were submitted to ANOVA and Tukey's test at 5% significance.Results At 140 degrees C, Obtura Flow presented the highest thermoplasticity values and Regular Obtura, the lowest. At 170 degrees C, Obtura Flow and Resilon demonstrated greater plasticization. Resilon had the highest mean thermoplasticity values at 200 degrees C.Conclusions Thermoplasticity values were influenced both by the temperature settings on the Obtura II System and by the type of material analysed. Obtura Flow and Resilon had the highest mean thermoplasticity values.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

O sistema Diramic foi avaliado para o diagnóstico das infecções do trato urinário (ITU). O sistema Diramic foi desenvolvido em Cuba e possibilita resultados de diagnóstico das infecções do trato urinário (ITU) em quatro horas e baseia-se na variação da turvação do crescimento microbiano no meio de cultura após incubação a 37ºC/4 horas. 396 amostras de urinas provenientes de ambulatórios e enfermarias do HC da FMB-UNESP-Botucatu/SP foram analisadas pelo sistema Diramic. O método da alça calibrada (AC) foi adotado como método de referência. A taxa de coincidência entre os dois métodos foi de 96,46% (382 amostras de urina), não havendo diferença significativa entre os resultados obtidos nos dois métodos. Os resultados para sensibilidade e especificidade foram 84,37 e 98,80% respectivamente e 10 resultados no Diramic foram falsos negativos (2,5%) e 4 falso positivos (1,01%). Os microrganismos identificados nas urinas positivas foram Escherichia coli (68,75%), Klebsiella pneumoniae (10,94%), leveduras (6,25%), Pseudomonas aeruginosa (4,69%), Enterobacter cloacae (3,12%) e Proteus mirabilis, Staphyloccocus coagulase negativo, Morganella morganii e Citrobacter freundii também foram identificadas (1,56% para cada espécie). O método Diramic foi eficiente na triagem das urinoculturas, porém verificou-se algumas restrições quanto ao diagnóstico das infecções do trato urinário quando causadas por leveduras e em pacientes submetidos a antibioticoterapia.