931 resultados para Energy flow levels


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Adult B-cell acute lymphoblastic leukemia remains a major therapeutic challenge, requiring a better characterization of the molecular determinants underlying disease progression and resistance to treatment. Here, using a phospho-flow cytometry approach we show that adult diagnostic B-cell acute lymphoblastic leukemia specimens display PI3K/Akt pathway hyperactivation, irrespective of their BCR-ABL status and despite paradoxically high basal expression of PTEN, the major negative regulator of the pathway. Protein kinase CK2 is known to phosphorylate PTEN thereby driving PTEN protein stabilization and concomitant PTEN functional inactivation. In agreement, we found that adult B-cell acute lymphoblastic leukemia samples show significantly higher CK2 kinase activity and lower PTEN lipid phosphatase activity than healthy controls. Moreover, the clinical-grade CK2 inhibitor CX-4945 (Silmitasertib) reversed PTEN levels in leukemia cells to those observed in healthy controls, and promoted leukemia cell death without significantly affecting normal bone marrow cells. Our studies indicate that CK2-mediated PTEN posttranslational inactivation, associated with PI3K/Akt pathway hyperactivation, are a common event in adult B-cell acute lymphoblastic leukemia and suggest that CK2 inhibition may constitute a valid, novel therapeutic tool in this malignancy.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Dissertation to obtain the Doctoral degree in Physics Engineering

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Dissertação para obtenção do Grau de Doutor em Engenharia Electrotécnica e de Computadores

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this thesis a piezoelectric energy harvesting system, responsible for regulating the power output of a piezoelectric transducer subjected to ambient vibration, is designed to power an RF receiver with a 6 mW power consump-tion. The electrical characterisation of the chosen piezoelectric transducer is the starting point of the design, which subsequently presents a full-bridge cross-coupled rectifier that rectifies the AC output of the transducer and a low-dropout regulator responsible for delivering a constant voltage system output of 0.6 V, with low voltage ripple, which represents the receiver’s required sup-ply voltage. The circuit is designed using CMOS 130 nm UMC technology, and the system presents an inductorless architecture, with reduced area and cost. The electrical simulations run for the complete circuit lead to the conclusion that the proposed piezoelectric energy harvesting system is a plausible solution to power the RF receiver, provided that the chosen transducer is subjected to moderate levels of vibration.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The assessment of wind energy resource for the development of deep offshore wind plants requires the use of every possible source of data and, in many cases, includes data gathered at meteorological stations installed at islands, islets or even oil platforms—all structures that interfere with, and change, the flow characteristics. This work aims to contribute to the evaluation of such changes in the flow by developing a correction methodology and applying it to the case of Berlenga island, Portugal. The study is performed using computational fluid dynamic simulations (CFD) validated by wind tunnel tests. In order to simulate the incoming offshore flow with CFD models a wind profile, unknown a priori, was established using observations from two coastal wind stations and a power law wind profile was fitted to the existing data (a=0.165). The results show that the resulting horizontal wind speed at 80 m above sea level is 16% lower than the wind speed at 80 m above the island for the dominant wind direction sector.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Particle Pollution (PM) is a major problem in urban environments. There is serious health risks associated with exposure to PM. In addition, particulate matter also contributes to greenhouse effects and global warming. PM originates mainly from fuel combustion. In this paper, we attempt to study household energy use contributions to experienced levels of PM concentrations. We find that there is a strong positive association between household gasoline consumption and urban air pollution. Residential natural gas use is also associated with poor air quality.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We use a new dataset to study how mutual fund flows depend on past performance across 28 countries. We show that there are marked differences in the flow-performance relationship across countries, suggesting that US findings concerning its shape do not apply universally. We find that mutual fund investors sell losers more and buy winners less in more developed countries. This is because investors in more developed countries are more sophisticated and face lower costs of participating in the mutual fund industry. Higher country-level convexity is positively associated with higher levels of risk taking by fund managers.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The eco-efficient, self-compacting concrete (SCC) production, containing low levels of cement in its formulation, shall contribute for the constructions' sustainability due to the decrease in Portland cement use, to the use of industrial residue, for beyond the minimization of the energy needed for its placement and compaction. In this context, the present paper intends to assess the viability of SCC production with low cement levels by determining the fresh and hardened properties of concrete containing high levels of fly ash (FA) and also metakaolin (MK). Hence, 6 different concrete formulations were produced and tested: two reference concretes made with 300 and 500 kg/m3 of cement; the others were produced in order to evaluate the effects of high replacement levels of cement. Cement replacement by FA of 60% and by 50% of FA plus 20% of MK were tested and the addition of hydrated lime in these two types of concrete were also studied. To evaluate the self-compacting ability slump flow test, T500, J-ring, V-funnel and L-box were performed. In the hardened state the compressive strength at 3, 7, 14, 21, 28 and 90 days of age was determined. The results showed that it is possible to produce low cement content SCC by replacing high levels of cement by mineral additions, meeting the rheological requirements for self-compacting, with moderate resistances from 25 to 30 MPa after 28 days.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Charcoal is an important energy raw material and its properties are influenced by the wood's anatomical and chemical composition and the production process. The aim of this study was to evaluate the anatomical characteristics, calorific power and volatiles and ash content of carbonized wood from Byrsonima spicata, Calophyllum brasiliense, Cecropia sciadophylla, Cochlospermum orinocense and Schefflera morototoni. The calorific power varied from 26,878 to 31,117 kJ kg-1; the content of volatile materials ranged from 20.9 to 31.7%; ash content ranged from 0.1 to 3.8%; and carbon content varied from 68.2 to 75.3%. Anatomical structures of charcoal can be used for species identification. The studied species are not indicated for charcoal production because the levels of ash and volatile compounds are higher than those recommended for charcoal produced for household use. In addition, the calorific power and level of carbon content are insufficient for use in the steel industry.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The distribution and orientation of energy inside jets is predicted to be an experimental handle on colour connections between the hard--scatter quarks and gluons initiating the jets. This Letter presents a measurement of the distribution of one such variable, the jet pull angle. The pull angle is measured for jets produced in tt¯ events with one W boson decaying leptonically and the other decaying to jets using 20.3 fb−1 of data recorded with the ATLAS detector at a centre--of--mass energy of s√=8 TeV at the LHC. The jet pull angle distribution is corrected for detector resolution and acceptance effects and is compared to various models.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Dissertação de mestrado integrado em Engenharia Mecânica

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Dissertação de mestrado integrado em Engenharia Civil

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Documento submetido para revisão pelos pares. A publicar em Journal of Parallel and Distributed Computing. ISSN 0743-7315

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE - To investigate the initial energy level required for electrical cardioversion of atrial fibrillation (AF). METHODS - We studied patients undergoing electrical cardioversion in the 1st Multicenter Trial of SOCESP. Patients were divided into 2 groups according to the initial energy level of electrical cardioversion: 100J and > or = 150J. We compared the efficacy of the initial and final shock of the procedure, the number of shocks administered, and the cumulative energy levels. RESULTS - Eight-six patients underwent electrical cardioversion. In 53 patients (62%), cardioversion was started with 100J, and in 33 patients (38%), cardioversion was started with > or = 150J. Groups did not differ regarding clinical features and therapeutical interventions. A tendency existed towards greater efficacy of the initial shock in patients who received > or = 150J (61% vs. 42% in the 100J group, p=0.08). The number of shocks was smaller in the > or = 150J group (1.5±0.7 vs. 2.1±1.3, p=0.04). No difference existed regarding the final efficacy of electrical cardioversion and total cumulative energy levels in both groups. In the subgroup of patients with recent-onset AF (<=48h), the cumulative energy level was lower in the 100J group (240±227J vs. 324±225J, p=0.03). CONCLUSION - Patients who were given initial energy of > or = 150J received fewer counter shocks with a tendency toward greater success than those patients who were given 100J; however, in patients with recent-onset AF, the average cumulative energy level was lower in the 100J group. These data suggest that electrical cardioversion should be initiated with energy levels > or = 150J in patients with chronic AF.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Tese de Doutoramento em Engenharia Civil.