947 resultados para Echocardiography, Doppler, Color
Resumo:
Mestrado em Tecnologia de Diagnóstico e Intervenção Cardiovascular - Ramo de especialização: Ultrassonografia Cardiovascular
Resumo:
To study luminescence, reflectance, and color stability of dental composites and ceramics. Materials and Methods: IPS e.max, IPS Classic, Gradia, and Sinfony materials were tested, both unpolished (as-cast) and polished specimens. Coffee, tea, red wine, and distilled water (control) were used as staining drinks. Disk-shaped specimens were soaked in the staining drinks for up to 5 days. Color was measured by a colorimeter. Fluorescence was recorded using a spectrofluorometer, in the front-face geometry. Time-resolved fluorescence spectra were recorded using a laser nanosecond spectrofluorometer. Results: The exposure of the examined dental materials to staining drinks caused changes in color of the composites and ceramics, with the polished specimens exhibiting significantly lower color changes as compared to unpolished specimens. Composites exhibited lower color stability as compared to ceramic materials. Water also caused perceptible color changes in most materials. The materials tested demonstrated significantly different initial luminescence intensities. Upon exposure to staining drinks, luminescence became weaker by up to 40%, dependent on the drink and the material. Time-resolved luminescence spectra exhibited some red shift of the emission band at longer times, with the lifetimes in the range of tens of nanoseconds. Conclusions: Unpolished specimens with a more developed surface have lower color stability. Specimens stored in water develop some changes in their visual appearance. The presently proposed methods are effective in evaluating the luminescence of dental materials. Luminescence needs to be tested in addition to color, as the two characteristics are uncorrelated. It is important to further improve the color and luminescence stability of dental materials.
Resumo:
The wide use of antibiotics in aquaculture has led to the emergence of resistant microbial species. It should be avoided/minimized by controlling the amount of drug employed in fish farming. For this purpose, the present work proposes test-strip papers aiming at the detection/semi-quantitative determination of organic drugs by visual comparison of color changes, in a similar analytical procedure to that of pH monitoring by universal pH paper. This is done by establishing suitable chemical changes upon cellulose, attributing the paper the ability to react with the organic drug and to produce a color change. Quantitative data is also enabled by taking a picture and applying a suitable mathematical treatment to the color coordinates given by the HSL system used by windows. As proof of concept, this approach was applied to oxytetracycline (OXY), one of the antibiotics frequently used in aquaculture. A bottom-up modification of paper was established, starting by the reaction of the glucose moieties on the paper with 3-triethoxysilylpropylamine (APTES). The so-formed amine layer allowed binding to a metal ion by coordination chemistry, while the metal ion reacted after with the drug to produce a colored compound. The most suitable metals to carry out such modification were selected by bulk studies, and the several stages of the paper modification were optimized to produce an intense color change against the concentration of the drug. The paper strips were applied to the analysis of spiked environmental water, allowing a quantitative determination for OXY concentrations as low as 30 ng/mL. In general, this work provided a simple, method to screen and discriminate tetracycline drugs, in aquaculture, being a promising tool for local, quick and cheap monitoring of drugs.
Resumo:
BACKGROUND: Atherosclerotic carotid disease represents approximately 20% of the causes of ischemic stroke. Effective treatment options, such as endovascular or surgical revascularization procedures, are available. Doppler Ultrasound (DUS) is a non-invasive, inexpensive, routine exam used to evaluate the presence of internal carotid artery (ICA) stenosis. We retrospectively analysed the prevalence of severe atherosclerotic carotid disease in a population of patients with acute ischemic stroke/transitory ischemic attacks (TIAs), and the role of DUS in the detection of ICA stenosis and treatment decisions in these patients. METHODS: A total of 318 patients with ischemic stroke or TIAs was admitted to our stroke unit, and 260 patients were studied by DUS. ICA stenosis was evaluated by DUS according to peak systolic velocity. All DUS exams were performed by the same operator. ICA stenosis was further assessed in 43 patients by digital subtraction angiography (DSA) using NASCET criteria. RESULTS: Of the total 318 patients, 260 (82%) had DUS evaluation. Of the total 520 ICAs studied by DUS, degrees of ICA stenosis were: 0-29% n= 438 (84%); 30-49% n= 8 (2%); 50-69% n= 27 (5%); 70-89% n= 15 (3%); 90-99% n= 20 (4%); oclusão n= 14 (2%). Of the total 260 patients studied, 43 (16.5%) underwent DSA. Sensibility and specificity of DUS in the diagnosis of carotid stenosis over 70% were, respectively, 91% e 84%. Of the total 31 patients with significant carotid stenosis (70-99%), 23 (74%) underwent subsequent carotid revascularization procedures. DISCUSSION: DUS is an important screening test in our stroke unit, justifying its use as a routine exam for all patients with ischemic stroke/TIAs. Moreover, our results show the relevance of severe carotid disease in a population with acute ischemic stroke/TIAs (16.5%), with a total of 9% of patients being submitted to carotid revascularization procedures.
Resumo:
BACKGROUND: Valve surgery in children is aimed at restoring correct hemodynamics with few reoperations and limited resort to prostheses, which would imply early deterioration or definitive hypocoagulation. OBJECTIVES: Report a series of paediatric pts with acquired mitral valve disease, mostly due to rheumatic disease, in whom it was possible, for the great majority, to repair the damaged valve. DEMOGRAPHICS: Fifty children with predominant mitral valve disease, 47 rheumatic (94%) and 3 after endocarditis were consequently operated by the same surgical team over the last five years. Ages were 12.5+/-3.1 yrs and weights 33.2+/-8.4 Kg, 30 pts presented with predominant mitral regurgitation and 20 pts had significant stenosis. In 8 pts there also moderate to severe aortic regurgitation and in 2 pts severe tricuspid regurgitation was present. Patients were not operated during the acute phase of the disease. Five pts were reoperations and from those, all but one received mechanical prosthesis. RESULTS: In all operations the intention was to repair the mitral valve. In 46 pts complex mitral valvuloplasties were performed extended comissurotomies, shortening of chordae, chordal replacement with PTFE, and reconstruction of valve leaflefts by direct patching or pericardial extension of the retracted posterior leaflet (78.2% cases), plus reshaping of the annulus by using a fixed prosthetic CE ring (sizes 26 to 32) in every case. Ring sizes correlated poorly with body weights, but correlation was close and positive for the use of pericardial advancement of the posterior leaflet (p<0.01). There was no operative mortality, but one pt died early from sepsis and there was no late mortality. Maximum follow up extends now to 50 months (median 28 months) and functional evaluation, at latest follow up, as assessed by Doppler Echocardiography, showed residual mitral regurgitation, mild-moderate in 4 pts and LA-LV gradients mild in 5 and moderate in 2 pts. NYHA functional class, at present follow-up is class I for 43 pts (88%) and class II in the remaining 6 pts. Along the follow-up period 2 pts had to be reoperated for early repair failures and other three for late failures, presently freedom for reoperation is 91.8% at 5 years. CONCLUSIONS: Mitral valve repair in children with rheumatic lesions can be achieved for the great majority of cases by using different techniques. Pericardial extension of the retracted posterior leaflet allowed the use of a bigger size prosthetic ring. Intermediate functional results are good with fair functional classes and few reoperations but follow-up is short and does not allow us to draw conclusions about the long-term results of the repair in these rheumatic patients.
Resumo:
Previous studies have shown that a ratio of early transmitral flow velocity to early diastolic velocity of the mitral annulus (E/E') of > 15, obtained by tissue Doppler imaging (TDI), correlates with left ventricular filling pressure. OBJECTIVE: The aim of our study was to assess whether E/E' provides prognostic information in patients with dilated cardiomyopathy. METHODS: We studied 33 patients with dilated cardiomyopathy and mean ejection fraction of 31%. All the patients underwent routine two-dimensional and Doppler echocardiographic examination and TDI to determine early peak velocity of the mitral annulus. Pro-B-type natriuretic peptide (pro-BNP) and peak oxygen consumption (VO2max) were also measured. Patients were divided into two groups according to the value of E/E': Group I (n = 15 patients) with E/E' > or = 15 and Group II (n = 18 patients) with E/E' < 15. Patients were followed for 12+/-4 months; new hospital admission due to heart failure, heart transplantation and death were considered as cardiac events. RESULTS: There were significant differences between the two groups in conventional two-dimensional echocardiographic measurements (dimensions and ejection fraction) and Doppler parameters (mitral inflow). With regard to mitral annular velocities obtained by TDI at two different points (septum and lateral wall), the E', A' and S' velocities differed significantly between the two groups, with lower velocities in Group I. Systolic velocity measured in the lateral portion of the mitral annulus showed the most significant difference: Group I - 4.46 cm/sec versus Group II - 7.19 cm/sec, p < 0.00001. Pro-BNP was 5622 pg/ml in Group I, and 1254 pg/ml in Group II, p = 0.004. VO2 max was significantly different between the two groups: Group I - 17.6 ml/kg/min versus Group II - 22.8 ml/kg/min, p = 0.004. During follow-up, events were more common in Group I, with 9 patients (60%) having events, while in Group II, the event rate was 11.1% (2 patients), p = 0.004. CONCLUSION: The ratio of early transmitral flow velocity to early diastolic velocity of the mitral annulus is a powerful predictor of clinical outcome. Lower velocities of mitral annulus on TDI are expected in patients with E/E' > or = 15. Systolic velocities of under 5 cm/sec measured in the lateral portion of the mitral annulus appeared to be strongly related to prognosis.
Resumo:
"Cor triatriatum dexter" (CTD) is an unusual cyanotic cardiac defect in which the right atrium is subdivided into two distinct chambers due to the persistence of the "sinus venosus" valve. Two patients with CTD ho were evaluated and treatment in 1979 and 1992 are described: the first one, had total anomalous pulmonary venous return to the coronary sinus or "cor triatriatum sinister" as preoperative diagnosis based on M-mode echocardiographic findings. The presence of a membrane inside the right atrium was suspected on cineangiogram. The other one had a preoperative diagnosis of CTD. Anatomic relationships and physiological effects were established by two dimensional and Doppler ultrasonography and confirmed at cardiac catheterization and surgery. High resolution two dimensional echocardiography coupled with Doppler ultrasonography has a definite role in the study of this heart defect.
Resumo:
The authors analyzed 704 transthoracic echocardiographic (TTE) examinations, performed routinely to all admitted patients to a general 16-bed Intensive Care Unit (ICU) during an 18-month period. Data acquisition and prevalence of abnormalities of cardiac structures and function were assessed, as well as the new, previously unknown severe diagnoses. A TTE was performed within the first 24 h of admission on 704 consecutive patients, with a mean age of 61.5+/-17.5 years, ICU stay of 10.6+/-17.1 days, APACHE II 22.6+/-8.9, and SAPS II 52.7+/-20.4. In four patients, TTE could not be performed. Left ventricular (LV) dimensions were quantified in 689 (97.8%) patients, and LV function in 670 (95.2%) patients. Cardiac output (CO) was determined in 610 (86.7%), and mitral E/A in 399 (85.9% of patients in sinus rhythm). Echocardiographic abnormalities were detected in 234 (33%) patients, the most common being left atrial (LA) enlargement (n=163), and LV dysfunction (n=132). Patients with these alterations were older (66+/-16.5 vs 58.1+/-17.4, p<0.001), presented a higher APACHE II score (24.4+/-8.7 vs 21.1+/-8.9, p<0.001), and had a higher mortality rate (40.1% vs 25.4%, p<0.001). Severe, previously unknown echocardiographic diagnoses were detected in 53 (7.5%) patients; the most frequent condition was severe LV dysfunction. Through a multivariate logistic regression analysis, it was determined that mortality was affected by tricuspid regurgitation (p=0.016, CI 1.007-1.016) and ICU stay (p<0.001, CI 1-1.019). We conclude that TTE can detect most cardiac structures in a general ICU. One-third of the patients studied presented cardiac structural or functional alterations and 7.5% severe previously unknown diagnoses.
Resumo:
Introdução: A Pressão Venosa Central (PVC), é um importante parâmetro hemodinâmico, reflectindo o estado de hidratação. Embora existam estudos de cálculo não invasivo da PVC por ecocardiografia, não está descrito um método de quantificação exacta da mesma. Objectivos: Analisando diversos parâmetros ecocardiográficos, os autores propõem uma fórmula de cálculo da PVC que mostra boa correlação estatística com a PVC medida de forma invasiva. Material e Métodos: O estudo foi efectuado em 45 doentes internados na UCI, 32 em ritmo sinusal e 13 em fibrilhação auricular, 32 dos quais submetidos a ventilação mecânica. Fizeram-se simultaneamente medições invasivas da PVC e o estudo ecocardiográfico transtorácico com Doppler. Os métodos estatísticos utilizados foram a correlação bivariada e análise de variâncias. Resultados: Foram encontrados diversos parâmetros ecocardiográficos que mostram boa correlação com o valor da PVC medida. A estes foram aplicados coeficientes estandardizados e obteve-se a seguinte fórmula de cálculo da PVC: (desaceleração E tricúspide) x 0,11 + (gradiente VD/AD) x 0,16 - (variação da VCI). Conclusão: Acrescenta-se mais um elemento de avaliação hemodinâmica não invasiva quantificando um parâmetro até agora só avaliado de forma aproximada por esta abordagem.
As Alterações do Doppler Cardíaco Perante Modificação da Volémia em Cuidados Intensivos Polivalentes
Resumo:
Num grupo de 64 doentes de uma Unidade de Cuidados Intensivos, 24 dos quais submetidos a ventilação mecânica, foi determinada a influência da modificação da volémia nas características do Doppler cardíaco, através da negativização do balanço hídrico e correspondente modificação da pressão venosa central. Com a modificação da volémia, a relação E/A do fluxo transvalvular mitral mostrou uma tendência para reduzir, o tempo de desaceleração da onda E mitral para diminuir, o tempo de relaxamento isovolumétrico para aumentar, e a veia cava inferior reduziu o seu diâmetro expiratório e aumentou o valor do colapso inspiratório. Não se observou uma correlação significativa entre os valores das variáveis estudadas e a modificação da volémia, inclusivamente entre a pressão venosa central e o balanço hídrico. A modificação da volémia em doentes críticos modifica as características de determinados parâmetros de ecocardiografia- -Doppler, mas não é possível predizer a magnitude dessa variação.
Resumo:
A pilot study aimed to introduce intraoperative monitoring of liver surgery using transoesophageal echocardiography (TEE) is described. A set of TEE measurements was established as a protocol, consisting of left atrial (LA) dimension at the aortic valve plane; mitral velocity flow integral, calculation of stroke volume and cardiac output (CO); mitral annular plane systolic excursion; finally, right atrial area. A total of 165 measurements (on 21 patients) were performed, 31 occurring during hypotension. The conclusions reached were during acute blood loss LA dimension changed earlier than CVP, and, in one patient, a dynamic left ventricular (LV) obstruction was observed; in 3 patients a transient LV systolic dysfunction was documented. The comparison between 39 CO paired measurements obtained by TEE and PiCCO2 revealed a statistically significant correlation (P < 0.001, r = 0.83). In this pilot study TEE successfully answered the questions raised by the anesthesiologists. Larger cohort studies are needed to address this issue.
Resumo:
A pressão de encravamento da artéria pulmonar (Pw) é um importante parâmetro hemodinâmico frequentemente utilizado em Cuidados Intensivos. Não é portanto de estranhar o esforço aplicado por inúmeros autores na sua determinação não invasiva por ecocardiografia. Neste trabalho os autores fizeram uma revisão da literatura sobre este assunto em particular. A par de algumas fórmulas de determinação não invasiva, encontram-se muitas referências relativas a correlações entre parâmetros ecocardiográficos e a Pw. As modificações de parâmetros ecocardiográficos com a volémia é igualmente um campo de pesquisa relacionado, bem como as recentes publicações envolvendo o estudo do Doppler de tecido. Apesar do enorme esforço colocado nesta pesquisa em particular, é difícil eleger um único parâmetro fidedigno de avaliação não invasiva da Pw. O problema da transposição de fórmulas e correlações entre populações de doentes distintas é particularmente sentido neste campo. A determinação não invasiva da Pw em ambiente clínico continua a constituir um problema para a técnica ecocardiográfica, colocando em causa a sua real vocação.
Resumo:
Objectivo: estudo comparativo simultâneo de medições invasivas utilizando o cateterismo da artéria pulmonar e não invasivas utilizando a ecocardiografia transtorácica (ETT) de 4 parâmetros hemodinâmicos: débito cardíaco (DC), pressão de encravamento da artéria pulmonar (PCP), pressão venosa central (PVC), e pressão sistólica da artéria pulmonar (PSAP). Material e Métodos: estudo prospectivo numa Unidade de Cuidados Intensivos (UCI) médico-cirurgica. Foram estudados 41 doentes em pós-operatório de transplante hepático, nos quais o DC, a PCP, a PVC e a PSAP foram obtidos em simultâneo por 2 observadores independentes, utilizando a ETT e o cateterismo invasivo da artéria pulmonar. Para a quantificação por ETT dos parâmetros foram utilizadas fórmulas descritas na literatura. As medições invasivas e não invasivas foram comparadas através de uma análise de correlação linear e de Bland-Altman. Resultados: Verificou-se uma boa correlação nas medições invasivas e não invasivas do DC (r=0,97) e PVC (r=0,88). As correlações entre as medições invasivas e não invasivas da PCP e da PSAP foram fracas (r=0,41 e r= 0,118 respectivamente). O intervalo de confiança de 95% e bias para o DC foi negligenciável, em especial para valores de DC abaixo dos 6l/minuto. A ETT subestima em regra o DC, mas as duas técnicas mostraram uma correlação significativa entre si. Conclusões: a ETT pode estimar de forma fidedigna o DC em doentes submetidos a transplante hepático. A determinação não invasiva das restantes variáveis hemodinâmicas por ETT pode estar sujeita a uma variabilidade grande relacionada com as características dos doentes. Apesar dos dados terem sido obtidos num grupo específico de doentes, podem ajudar a definir uma aplicação futura da ecocardiografia em Cuidados Intensivos.
Resumo:
Apresenta-se um caso clínico de dissecção da aorta abdominal - tipo B - diagnosticada por eco-Doppler e tomografia axial computorizada (TC). Discute-se o interesse do eco-Doppler no diagnóstico de dissecção da aorta abdominal e na avaliação do envolvimento arterial visceral. É ainda um método útil no follow-up dos doentes com terapêutica conservadora.
Resumo:
PURPOSE: To determine the correlation between ocular blood flow velocities and ocular pulse amplitude (OPA) in glaucoma patients using colour Doppler imaging (CDI) waveform analysis. METHOD: A prospective, observer-masked, case-control study was performed. OPA and blood flow variables from central retinal artery and vein (CRA, CRV), nasal and temporal short posterior ciliary arteries (NPCA, TPCA) and ophthalmic artery (OA) were obtained through dynamic contour tonometry and CDI, respectively. Univariate and multiple regression analyses were performed to explore the correlations between OPA and retrobulbar CDI waveform and systemic cardiovascular parameters (blood pressure, blood pressure amplitude, mean ocular perfusion pressure and peripheral pulse). RESULTS: One hundred and ninety-two patients were included [healthy controls: 55; primary open-angle glaucoma (POAG): 74; normal-tension glaucoma (NTG): 63]. OPA was statistically different between groups (Healthy: 3.17 ± 1.2 mmHg; NTG: 2.58 ± 1.2 mmHg; POAG: 2.60 ± 1.1 mmHg; p < 0.01), but not between the glaucoma groups (p = 0.60). Multiple regression models to explain OPA variance were made for each cohort (healthy: p < 0.001, r = 0.605; NTG: p = 0.003, r = 0.372; POAG: p < 0.001, r = 0.412). OPA was independently associated with retrobulbar CDI parameters in the healthy subjects and POAG patients (healthy CRV resistance index: β = 3.37, CI: 0.16-6.59; healthy NPCA mean systolic/diastolic velocity ratio: β = 1.34, CI: 0.52-2.15; POAG TPCA mean systolic velocity: β = 0.14, CI 0.05-0.23). OPA in the NTG group was associated with diastolic blood pressure and pulse rate (β = -0.04, CI: -0.06 to -0.01; β = -0.04, CI: -0.06 to -0.001, respectively). CONCLUSIONS: Vascular-related models provide a better explanation to OPA variance in healthy individuals than in glaucoma patients. The variables that influence OPA seem to be different in healthy, POAG and NTG patients.