674 resultados para ELUTING STENTS
Resumo:
Transcatheter arterial chemoembolization (TACE) offers a survival benefit to patients with intermediate hepatocellular carcinoma (HCC). A widely accepted TACE regimen includes administration of doxorubicin-oil emulsion followed by gelatine sponge-conventional TACE. Recently, a drug-eluting bead (DC Bead) has been developed to enhance tumor drug delivery and reduce systemic availability. This randomized trial compares conventional TACE (cTACE) with TACE with DC Bead for the treatment of cirrhotic patients with HCC. Two hundred twelve patients with Child-Pugh A/B cirrhosis and large and/or multinodular, unresectable, N0, M0 HCCs were randomized to receive TACE with DC Bead loaded with doxorubicin or cTACE with doxorubicin. Randomization was stratified according to Child-Pugh status (A/B), performance status (ECOG 0/1), bilobar disease (yes/no), and prior curative treatment (yes/no). The primary endpoint was tumor response (EASL) at 6 months following independent, blinded review of MRI studies. The drug-eluting bead group showed higher rates of complete response, objective response, and disease control compared with the cTACE group (27% vs. 22%, 52% vs. 44%, and 63% vs. 52%, respectively). The hypothesis of superiority was not met (one-sided P = 0.11). However, patients with Child-Pugh B, ECOG 1, bilobar disease, and recurrent disease showed a significant increase in objective response (P = 0.038) compared to cTACE. DC Bead was associated with improved tolerability, with a significant reduction in serious liver toxicity (P < 0.001) and a significantly lower rate of doxorubicin-related side effects (P = 0.0001). TACE with DC Bead and doxorubicin is safe and effective in the treatment of HCC and offers a benefit to patients with more advanced disease.
Resumo:
BACKGROUND: Clinical small-caliber vascular prostheses are unsatisfactory. Reasons for failure are early thrombosis and late intimal hyperplasia. We thus prepared biodegradable small-caliber vascular prostheses using electrospun polycaprolactone (PCL) with slow-releasing paclitaxel (PTX), an antiproliferative drug. METHODS AND RESULTS: PCL solutions containing PTX were used to prepare nonwoven nanofibre-based 2-mm ID prostheses. Mechanical morphological properties and drug loading, distribution, and release were studied in vitro. Infrarenal abdominal aortic replacement was carried out with nondrug-loaded and drug-loaded prostheses in 18 rats and followed for 6 months. Patency, stenosis, tissue reaction, and drug effect on endothelialization, vascular remodeling, and neointima formation were studied in vivo. In vitro prostheses showed controlled morphology mimicking extracellular matrix with mechanical properties similar to those of native vessels. PTX-loaded grafts with suitable mechanical properties and controlled drug-release were obtained by factorial design. In vivo, both groups showed 100% patency, no stenosis, and no aneurysmal dilatation. Endothelial coverage and cell ingrowth were significantly reduced at 3 weeks and delayed at 12 and 24 weeks in PTX grafts, but as envisioned, neointima formation was significantly reduced in these grafts at 12 weeks and delayed at 6 months. CONCLUSIONS: Biodegradable, electrospun, nanofibre, polycaprolactone prostheses are promising because in vitro they maintain their mechanical properties (regardless of PTX loading), and in vivo show good patency, reendothelialize, and remodel with autologous cells. PTX loading delays endothelialization and cellular ingrowth. Conversely, it reduces neointima formation until the end point of our study and thus may be an interesting option for small caliber vascular grafts.
Resumo:
L’objectiu de l’estudi ha estat descriure els esdeveniments adversos en pacients portadors d’stents coronaris sotmesos a cirurgia no cardíaca, el maneig del tractament antiagregant plaquetari (AAP) i avaluar la relació entre l’aparició d’aquests esdeveniments amb la gestió perioperatòria dels AAP. Estudi observacional i prospectiu. Es van incloure 81 procediments quirúrgics. Un 96.3 % estava amb tractament AAP, la retirada es va realitzar en un 28.2%. La incidència d’esdeveniments cardíacs majors va ser 12.3 %, un 37% varen presentar altres complicacions. CONCLUSIONS El nostre estudi no mostra que el maneig del tractament AAP tingui relació amb els esdeveniments adversos.
Resumo:
La trachée et les bronches proximales sont de fins conduits subtils, ingénieusement structurés par une partie cartilagineuse antérieure résistante aux variations de pression et une partie membraneuse postérieure souple. Par leurs faibles volumes (espace mort) ils délivrent un grand pourcentage de l'air inspiré aux voies distales, puis au parenchyme pulmonaire, permettant les échanges de gaz. Cette belle harmonie respiratoire peut être rapidement mise à mal dès qu'un processus atteint ces voies respiratoires proximales, soit en les comprimant, processus sténosant, soit en affaiblissant leur structure, trachéo-bronchomalacie, soit en ouvrant leur paroi sur les structures médiastinales, fistule trachéo/broncho-médiastinales, pleurales ou autres. Le pronostic vital est alors rapidement engagé au vu de l'absolue nécessité du bon fonctionnement de ces fins conduits, une petite diminution du calibre de leurs fines lumières provoquant une baisse importante de leurs surfaces. Dans ces situations à haut potentiel de complication majeure les interventions endoscopiques pour restaurer l'intégrité de ces conduits sont alors fort risquées, et il est primordial de pouvoir les effectuer dans un cadre sécurisé au maximum. La réalisation de ces gestes par la technique décrite dans notre article « Use of combined suspension laryngoscopy, flexible bronchoscopy and high frequency jet ventilation forY-shaped airway stents delivery" permet la sécurité nécessaire à ces situations instable, en effet -la laryngoscopie en suspension expose les voies proximales en offrant un accès le plus large possible à l'arbre trachéobronchique ce qui permet l insertion de multiples instruments parfois volumineux, -la Jet ventilation assure une oxygénation et une ventilation adéquate par un fin cathéter placé soit dans le poumon sain, soit en distalité de la lésion -la bronchoscopie souple, passant au travers d'endroits exigus et courbes permet le déploiement sous vision direct, au millimètre près, de divers dispositifs. Cette association remplace avantageusement la technique traditionnelle qui insère les stents à l'aveugle, et en apnée, ce qui représente de haut risque de mauvais positionnement des stents avec des conséquences immédiates sur l'oxygénation et la ventilation souvent déjà bien altérées. Perspective et conclusion : cette technique est utile pour l'insertion des stents en Y, centraux, comme décrit dans notre article, et les indications peuvent être étendues aux stents distaux pour lesquels l'accès n'est parfois pas aisé avec le bronchoscope rigide, et pour d'autres interventions endoscopiques, laser, cryothérapie, radiofréquence ou l'insertion de nouveaux dispositifs.
Resumo:
Purpose: To evaluate the extent of quality of life (QoL) associated adverse events (AEs) following PRECISION TACE with DC Bead compared with conventional transarterial chemoembolisation (cTACE). Methods and Materials: 201 intermediate HCC patients were treated with DC Bead (PRECISION TACE) or conventional TACE (cTACE) with doxorubicin in the PRECISION V clinical study. 93 patients were treated with DC Bead and 108 Patients with cTACE every 2 months and followed up for 6 months. AEs were classified according to the South West Oncology Group criteria. QoL associated AEs were defined as alopecia, constipation, nausea, vomiting, pyrexia, chills, asthenia, fatigue, and headache. Results: The biggest difference in QoL associated AEs was for alopecia: 2 patients (2.2%) for DC-Bead versus 21 patients (19.4%) for cTACE. For other clinical symptoms, constipation (n=10; 10.8% vs. n=13; 12%), vomiting (n=10; 10.8% vs. n=14; 13.0%), pyrexia (n=16; 17.2% vs. n=26; 24.1%), chills (n=1; 1.1% vs. n=5; 4.6%), and headache (n=2; 2.2% vs. n=8; 7.4%) showed lower incidence in the DC Bead group versus cTACE. Nausea, n= 15; 13.9% (n=15; 16.1%) and fatigue, n=6; 5.6% (n=13; 14.0%) were lower for cTACE. Total dose of doxorubicin was on average 35% higher in the DC Bead group. Conclusion: Although patients in the DC Bead group received a higher doxorubicin dose, less QoL associated AEs were reported for this group. Alopecia, the most obvious outward sign of toxicity, was only reported in a tenth of DC Bead patients. Thus, PRECISION TACE with DC Bead improves quality of life associated adverse events.
Resumo:
Purpose: To load embolization particles (DC-Beads, Biocompatibles, UK) with an anti-angiogenic agent (sunitinib) and to characterize the in vitro properties of the Beads-drug association.Materials: DC Beads of 100-300µm were loaded using a specially designed 10mg/ml sunitinib solution. Loading profile was studied by spectrophotometry of the supernatant solution at 430nm at different time points. Release experiment was performed using the USP method 4 (flow-through cell). Spectrophotometric determination at 430nm was used to measure drug concentration in the eluting solution.Results: We were able to load >98% of the drug in the DC-Beads in 2 hours. The maximum concentration was 20mg sunitinib/ml DC Beads. Loaded Beads gradually released 59% of the loaded drug in the eluting solution, by an ionic exchange mechanism,over 6 hours.Conclusions: DC Beads could be loaded with the multi tyrosine kinase inhibitor sunitinib using a specially designed solution. High drug payload can be achieved. The loaded DC Beads released the drug in an ionic eluting solution with an interesting release profile.
Resumo:
Purpose: To evaluate the current management, and adherence to recommendations, of patients on oral anticoagulation (OAC) undergoing coronary stent implantation (PCI-S). Methods: By means of a contact person who had been previously identified in 8 European countries, a questionnaire was electronically forwarded between April and July 2010 to the national institutions where PCI-S is performed. Results: A total of 202 questionnaires (median response rate: 50%, range 33-78%) was received. The prevalence of OAC patients among those undergoing PCI-S is mostly reported 5-10% (97%). The peri-procedural pharmacological management mostly encompasses: preprocedural OAC interruption and bridging with low-molecular-weight heparin (59%), intraprocedural administration of an unfractionated heparin bolus (81%), and use of glycoprotein IIb/IIIa inhibitors on an individual basis (79%). The radial approach is reported as the preferred option (58%), as well as the implantation of bare metal stents (76%). Triple therapy (warfarin, aspirin, clopidogrel) is the most frequently prescribed (80%), generally for 1 month after bare metal stent (77%) and for at least 12 months after drug-eluting stent (60%). Throughout triple therapy, the International Normalized Ratio is mostly targeted to the lower end of the therapeutic range (77%), and gastric protection is routinely prescribed (69%), mostly by giving proton-pump inhibitors (70%). Conclusions: Among the 202 interventional cardiologists from the 8 European countries interviewed, the management of patients on OAC undergoing PCI-S appears variable and only partially adherent to currently available recommendations. (J Interven Cardiol 2012;25:163-169).
Resumo:
Background: Transcatheter arterial chemoembolization (TACE) has been shown to offer a survival benefit for patients with intermediate-stage hepatocellular carcinoma (HCC). A widely accepted TACE regimen includes the administration of a doxorubicin-in-oil emulsion followed by gelatine sponge particles. Recently, a drug-eluting bead (DEB) has been developed to enhance drug delivery to the tumor and reduce its systemic availability. Purpose of this randomized trial was to compare conventional TACE with DEB-TACE for the treatment of intermediate-stage HCC in patients with cirrhosis. Methods: Two hundred and twelve patients (185 males and 27 females; mean age, 67 years) with Child-Pugh A or B liver cirrhosis and large and/or multinodular, unresectable HCC were randomized to receive DEB-TACE (DC Bead; Biocompatibles, UK) uploaded with doxorubicin or conventional TACE with doxorubicin, lipiodol, and gelatin sponge particles. Randomization was stratified according to Child Pugh status (A or B), performance status (ECOG 0 or 1), bilobar disease (yes or no) and prior curative treatment (yes or no). Tumor response at 6 months was the primary study endpoint. An independent, blinded review of magnetic resonance imaging studies was conducted to assess tumor response according to amended RECIST criteria. Results: DEB-TACE with doxorubicin showed a higher rate of complete response, objective response and disease control compared with conventional TACE (27% vs 22%; 52% vs 44%; and 63% vs 52%, respectively; p>0.05). Patients with Child Pugh B, ECOG 1, bilobar disease and recurrence following curative treatment showed a significant increase in objective response (p=0.038) compared to the control. There was a marked reduction in serious liver toxicity in patients treated with DEB-TACE. The rate of doxorubicin related side effects was significantly lower (p=0.0001) in the DEB-TACE group compared with the conventional TACE group. Conclusions: DEB-TACE with doxorubicin is safe and effective in the treatment of intermediate-stage HCC and may offer benefit to patients with more advanced disease.
Resumo:
PURPOSE: The purpose of this study was to study the pharmacokinetics of irinotecan injected intravenously, intra-arterially, or loaded onto a delivery platform. MATERIAL AND METHODS: Fifty-four New Zealand White rabbits with VX2 liver tumor, divided in 3 groups of 17 rabbits, each received irinotecan either by intravenous (IV) route, intra-arterial hepatic (IA) route, or loaded on drug-eluting beads (DEBIRI). Animals were killed at 1, 6, and 24 h. Irinotecan and SN-38 concentrations were measured at different time points in serum, tumor, and normal liver. RESULTS: Twelve milligrams of irinotecan were injected IV and IA, whereas 6-16.5 mg were injected loaded onto DEBIRI. Normalized serum irinotecan reached a peak of 333 ng/ml (range 198.8-502.5) for IV, 327.1 ng/ml (range 277.1-495.6) for IA, and 189.7 ng/ml (range 111.1-261.9) for DEBIRI (P < 0.001) delivery. The area-under-the-curve value from 10 to 60 min of serum irinotecan concentration was significantly lower for DEBIRI (P = 0.0009). Tumor irinotecan levels for IV, IA, and DEBIRI (in ng/200 mg of tissue followed by ranges in parentheses) were, respectively, 23.6 (0.3-24.9), 36.5 (7.7-1914.1), and 20.2 (2.9-319) at 1 h; 4.2 (1-27.9), 99.3 (46.6-159.5), and 42.1 (11.3-189) at 6 h; and 2.7 (2.5-6.9), 18.3 (1.5-369.1), and 174.4 (3.4-5147.3) at 24 h (P = 0.02). At 24 h, tumor necrosis was 25% (10-30), 60% (40-91.25), and 95% (76.25-95) for IV, IA, and DEBIRI, respectively (P = 0.03). CONCLUSION: Compared with IV or IA, DEBIRI induces lower early serum levels of irinotecan, a high and prolonged intratumoral level of irinotecan, and a greater rate of tumor necrosis at 24 h. Further evaluation of the clinical benefit of DEBIRI is warranted.
Resumo:
Background: We demonstrated that DC Bead (Biocompatibles UK, Ltd) could be loaded with sunitinib and injected intra-arterially in the rabbit without unexpected toxicity. The purpose of this study is to evaluate the antitumoral effect of sunitinib eluting beads in the VX2 tumor model of liver cancer. Methods: VX2 tumors were implanted in the left liver lobe of New-Zealand white rabbits. Animals were assigned to 3 groups: Group 1 (n=6) received 1.5mg of sunitinib loaded in 0.05ml of 100-300um DC Bead, group 2 (n=5) received 0.05ml of 100-300um DC Bead, group 3 (n=5) received 0.05ml NaCl 0.9% in the left hepatic artery. One animal in each group was sacrificed at 24 hours and the others were followed for survival until day 15. Liver enzymes were measured daily. In group 1, plasmatic sunitinib concentration were measured daily by LC MS/MS tandem mass spectroscopy. At day 15 all living animals were sacrificed. After sacrifice, the livers were harvested for determination of the VEGF receptor tyrosine kinase activity by western blot and histopathological examination. Results: In group 1, no animals died during follow-up. In group 2, 2 animals died during follow-up on day x. In control group 3, 3 animals died during follow up on day x. In group 1 plasmatic sunitinib levels remained under therapeutic concentration throughout the experiment. Very high concentrations of sunitinib were measured in the liver tissue 24 and 15 days after embolization. Inhibition of the phosphorylation of the RTK was demonstrated at 24h and 15 days in groups 1. Sunitinib eluting beads seemed to penetrate in the tumor more effectively and there was more necrosis around the beads than their bland counterparts. Conclusions: Administration of sunitinib eluting beads in VX2 carrying rabbits resulted invery high drug concentrations at the site of embolization with minimal systemic passage. Despite the very high tissular sunitinib concentration we did not observe any additional toxicity with loaded beads. Sunitinib eluting beads inhibit the activation of RTK's triggered by ischemia and seem to prolong survival of the treated animals. Therefore we consider that local treatment with sunitinib may provide a promising approach for the treatment of liver cancer.
Resumo:
OBJECTIVE. The purpose of our study was to evaluate hepatic, gastrointestinal, and cardiac toxicity after PRECISION transarterial chemoembolization (TACE) with drug-eluting beads (DEB) versus conventional TACE with doxorubicin in the treatment of intermediate-stage hepatocellular carcinoma (HCC).SUBJECTS AND METHODS. Two hundred twelve patients (185 men and 27 women; mean age, 67 years) were randomized to TACE with DEB or conventional TACE. The majority of patients (67% in both groups) presented in a more advanced stage. Safety was measured by rate of adverse events (Southwest Oncology Group criteria) and changes in laboratory parameters. Cardiotoxicity was assessed with left ventricular ejection fraction (LVEF) mainly on MRI or echocardiography.RESULTS. The mean maximum postchemoembolization alanine transaminase increase in the DEB group was 50% less than in the conventional TACE group (p < 0.001) and 41% less in respect to aspartate transaminase (p < 0.001). End-of-study values returned to approximately baseline levels but with greater variability in conventional TACE patients. Treatment-emergent adverse events in the hepatobiliary system organ class occurred in 16.1% of DEB group patients compared with 25% of conventional TACE patients. There were fewer liver toxicity events in the DEB group. There was a small but statistically significant difference in mean change from baseline in LVEF between the two groups of 4 percentage points for the conventional TACE group (95% CI, 0.71-7.3; p = 0.018).CONCLUSION. PRECISION TACE with DEB loaded with doxorubicin offers a safe therapy option for intermediate-stage HCC, even in patients with more advanced liver disease.
Resumo:
In the last few years, there has been a growing focus on faster computational methods to support clinicians in planning stenting procedures. This study investigates the possibility of introducing computational approximations in modelling stent deployment in aneurysmatic cerebral vessels to achieve simulations compatible with the constraints of real clinical workflows. The release of a self-expandable stent in a simplified aneurysmatic vessel was modelled in four different initial positions. Six progressively simplified modelling approaches (based on Finite Element method and Fast Virtual Stenting – FVS) have been used. Comparing accuracy of the results, the final configuration of the stent is more affected by neglecting mechanical properties of materials (FVS) than by adopting 1D instead of 3D stent models. Nevertheless, the differencesshowed are acceptable compared to those achieved by considering different stent initial positions. Regarding computationalcosts, simulations involving 1D stent features are the only ones feasible in clinical context.