Incomplete reporting has been identified as a major source of avoidable waste in biomedical research.
Essential information is often not provided in study reports, impeding the identification, critical
appraisal, and replication of studies. To improve the quality of reporting of diagnostic accuracy
studies, the Standards for Reporting Diagnostic Accuracy (STARD) statement was developed. Here
we present STARD 2015, an updated list of 30 essential items that should be included in every
report of a diagnostic accuracy study. This update incorporates recent evidence about sources of
bias and variability in diagnostic accuracy and is intended to facilitate the use of STARD. As such,
STARD 2015 may help to improve completeness and transparency in reporting of diagnostic accuracy
studies.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Ce projet illustre cinq études, mettant l'emphase sur le développement d'une nouvelle approche diagnostique cardiovasculaire afin d'évaluer le niveau d’oxygène contenu dans le myocarde ainsi que sa fonction microvasculaire. En combinant une séquence de résonance magnétique cardiovasculaire (RMC) pouvant détecter le niveau d’oxygène (OS), des manœuvres respiratoires ainsi que des analyses de gaz artériels peuvent être utilisés comme procédure non invasive destinée à induire une réponse vasoactive afin d’évaluer la réserve d'oxygénation, une mesure clé de la fonction vasculaire. Le nombre de tests diagnostiques cardiaques prescrits ainsi que les interventions, sont en pleine expansion. L'imagerie et tests non invasifs sont souvent effectués avant l’utilisation de procédures invasives. L'imagerie cardiaque permet d’évaluer la présence ou absence de sténoses coronaires, un important facteur économique dans notre système de soins de santé. Les techniques d'imagerie non invasives fournissent de l’information précise afin d’identifier la présence et l’emplacement du déficit de perfusion chez les patients présentant des symptômes d'ischémie myocardique. Néanmoins, plusieurs techniques actuelles requièrent la nécessité de radiation, d’agents de contraste ou traceurs, sans oublier des protocoles de stress pharmacologiques ou physiques. L’imagerie RMC peut identifier une sténose coronaire significative sans radiation. De nouvelles tendances d’utilisation de RMC visent à développer des techniques diagnostiques qui ne requièrent aucun facteur de stress pharmacologiques ou d’agents de contraste. L'objectif principal de ce projet était de développer et tester une nouvelle technique diagnostique afin d’évaluer la fonction vasculaire coronarienne en utilisant l' OS-RMC, en combinaison avec des manœuvres respiratoires comme stimulus vasoactif. Ensuite, les objectifs, secondaires étaient d’utilisés l’OS-RMC pour évaluer l'oxygénation du myocarde et la réponse coronaire en présence de gaz artériels altérés. Suite aux manœuvres respiratoires la réponse vasculaire a été validée chez un modèle animal pour ensuite être utilisé chez deux volontaires sains et finalement dans une population de patients atteints de maladies cardiovasculaires. Chez le modèle animal, les manœuvres respiratoires ont pu induire un changement significatif, mesuré intrusivement par débit sanguin coronaire. Il a été démontré qu’en présence d'une sténose coronarienne hémodynamiquement significative, l’OS-RMC pouvait détecter un déficit en oxygène du myocarde. Chez l’homme sain, l'application de cette technique en comparaison avec l'adénosine (l’agent standard) pour induire une vasodilatation coronarienne et les manœuvres respiratoires ont pu induire une réponse plus significative en oxygénation dans un myocarde sain. Finalement, nous avons utilisé les manœuvres respiratoires parmi un groupe de patients atteint de maladies coronariennes. Leurs myocardes étant altérées par une sténose coronaire, en conséquence modifiant ainsi leur réponse en oxygénation. Par la suite nous avons évalué les effets des gaz artériels sanguins sur l'oxygénation du myocarde. Ils démontrent que la réponse coronarienne est atténuée au cours de l’hyperoxie, suite à un stimuli d’apnée. Ce phénomène provoque une réduction globale du débit sanguin coronaire et un déficit d'oxygénation dans le modèle animal ayant une sténose lorsqu’un supplément en oxygène est donné. En conclusion, ce travail a permis d'améliorer notre compréhension des nouvelles techniques diagnostiques en imagerie cardiovasculaire. Par ailleurs, nous avons démontré que la combinaison de manœuvres respiratoires et l’imagerie OS-RMC peut fournir une méthode non-invasive et rentable pour évaluer la fonction vasculaire coronarienne régionale et globale.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Ce projet illustre cinq études, mettant l'emphase sur le développement d'une nouvelle approche diagnostique cardiovasculaire afin d'évaluer le niveau d’oxygène contenu dans le myocarde ainsi que sa fonction microvasculaire. En combinant une séquence de résonance magnétique cardiovasculaire (RMC) pouvant détecter le niveau d’oxygène (OS), des manœuvres respiratoires ainsi que des analyses de gaz artériels peuvent être utilisés comme procédure non invasive destinée à induire une réponse vasoactive afin d’évaluer la réserve d'oxygénation, une mesure clé de la fonction vasculaire. Le nombre de tests diagnostiques cardiaques prescrits ainsi que les interventions, sont en pleine expansion. L'imagerie et tests non invasifs sont souvent effectués avant l’utilisation de procédures invasives. L'imagerie cardiaque permet d’évaluer la présence ou absence de sténoses coronaires, un important facteur économique dans notre système de soins de santé. Les techniques d'imagerie non invasives fournissent de l’information précise afin d’identifier la présence et l’emplacement du déficit de perfusion chez les patients présentant des symptômes d'ischémie myocardique. Néanmoins, plusieurs techniques actuelles requièrent la nécessité de radiation, d’agents de contraste ou traceurs, sans oublier des protocoles de stress pharmacologiques ou physiques. L’imagerie RMC peut identifier une sténose coronaire significative sans radiation. De nouvelles tendances d’utilisation de RMC visent à développer des techniques diagnostiques qui ne requièrent aucun facteur de stress pharmacologiques ou d’agents de contraste. L'objectif principal de ce projet était de développer et tester une nouvelle technique diagnostique afin d’évaluer la fonction vasculaire coronarienne en utilisant l' OS-RMC, en combinaison avec des manœuvres respiratoires comme stimulus vasoactif. Ensuite, les objectifs, secondaires étaient d’utilisés l’OS-RMC pour évaluer l'oxygénation du myocarde et la réponse coronaire en présence de gaz artériels altérés. Suite aux manœuvres respiratoires la réponse vasculaire a été validée chez un modèle animal pour ensuite être utilisé chez deux volontaires sains et finalement dans une population de patients atteints de maladies cardiovasculaires. Chez le modèle animal, les manœuvres respiratoires ont pu induire un changement significatif, mesuré intrusivement par débit sanguin coronaire. Il a été démontré qu’en présence d'une sténose coronarienne hémodynamiquement significative, l’OS-RMC pouvait détecter un déficit en oxygène du myocarde. Chez l’homme sain, l'application de cette technique en comparaison avec l'adénosine (l’agent standard) pour induire une vasodilatation coronarienne et les manœuvres respiratoires ont pu induire une réponse plus significative en oxygénation dans un myocarde sain. Finalement, nous avons utilisé les manœuvres respiratoires parmi un groupe de patients atteint de maladies coronariennes. Leurs myocardes étant altérées par une sténose coronaire, en conséquence modifiant ainsi leur réponse en oxygénation. Par la suite nous avons évalué les effets des gaz artériels sanguins sur l'oxygénation du myocarde. Ils démontrent que la réponse coronarienne est atténuée au cours de l’hyperoxie, suite à un stimuli d’apnée. Ce phénomène provoque une réduction globale du débit sanguin coronaire et un déficit d'oxygénation dans le modèle animal ayant une sténose lorsqu’un supplément en oxygène est donné. En conclusion, ce travail a permis d'améliorer notre compréhension des nouvelles techniques diagnostiques en imagerie cardiovasculaire. Par ailleurs, nous avons démontré que la combinaison de manœuvres respiratoires et l’imagerie OS-RMC peut fournir une méthode non-invasive et rentable pour évaluer la fonction vasculaire coronarienne régionale et globale.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Los niños y las niñas con disfunciones neurológicas tienen frecuentemente disfagia, condición que les ocasiona infecciones respiratorias a repetición, desnutrición, mala calidad de vida; su oportuno diagnóstico permite decidir sobre la mejor intervención. La videofluoroscopia y de videoendoscopia son técnicas diagnósticas invasivas, costosas y por lo tanto difíciles de hacerlas, lo que ocasiona retardo en el diagnóstico e intervención. Hoy en día existen nuevas tecnologías médicas no invasivas que pueden ser muy eficaces, una de ellas es la auscultación cervical que escucha los sonidos de la deglución mediante un estetoscopio u otro dispositivo de medición como la colocación de un micrófono o un acelerómetro en la superficie del cuello. Este método tiene como principio que los sonidos y/o movimientos biológicos normales de la deglución son diferentes de los anormales. En este artículo se presenta una revisión de la pertinencia social del diagnóstico de la disfagia, de las aplicaciones clínicas de la auscultación cervical y los dispositivos usados para realizarla, como una base para establecer su potencial de uso para la detección de disfagia en niños con problemas de neurodesarrollo. Estas orientaciones teóricas permiten al médico tener actuaciones más acertadas en el diagnóstico integral de niños y niñas con disfunción neurológica

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Leishmaniasis, caused by Leishmania infantum, is a vector-borne zoonotic disease that is endemic to the Mediterranean basin. The potential of rabbits and hares to serve as competent reservoirs for the disease has recently been demonstrated, although assessment of the importance of their role on disease dynamics is hampered by the absence of quantitative knowledge on the accuracy of diagnostic techniques in these species. A Bayesian latent-class model was used here to estimate the sensitivity and specificity of the Immuno-fluorescence antibody test (IFAT) in serum and a Leishmania-nested PCR (Ln-PCR) in skin for samples collected from 217 rabbits and 70 hares from two different populations in the region of Madrid, Spain. A two-population model, assuming conditional independence between test results and incorporating prior information on the performance of the tests in other animal species obtained from the literature, was used. Two alternative cut-off values were assumed for the interpretation of the IFAT results: 1/50 for conservative and 1/25 for sensitive interpretation. Results suggest that sensitivity and specificity of the IFAT were around 70–80%, whereas the Ln-PCR was highly specific (96%) but had a limited sensitivity (28.9% applying the conservative interpretation and 21.3% with the sensitive one). Prevalence was higher in the rabbit population (50.5% and 72.6%, for the conservative and sensitive interpretation, respectively) than in hares (6.7% and 13.2%). Our results demonstrate that the IFAT may be a useful screening tool for diagnosis of leishmaniasis in rabbits and hares. These results will help to design and implement surveillance programmes in wild species, with the ultimate objective of early detecting and preventing incursions of the disease into domestic and human populations.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: To evaluate changes in retinal nerve fiber layer thickness as measured by scanning laser polarimetry (SLP) after the use of medication to reduce intraocular pressure (IOP) in glaucomatous or ocular hypertensive patients. METHODS: The authors prospectively enrolled 37 eyes of 37 patients in whom IOP was reduced by more than 25% after the use of medication. The images were obtained before and 15 to 30 days after the introduction of medication. The SLP parameters measured before and after the use of medication were compared using paired Student's t Test. RESULTS: The mean IOP was significantly reduced from 26.57±4.23 mmHg to 16.54 ±2.92 mmHg after the use of medication (p<0.05). None of the 10 SLP analyzed parameters was significantly affected by the reduction of IOP with medication (p>0.05). CONCLUSION: The retinal nerve fiber layer thickness, as measured by SLP, is not affected by the reduction of IOP with medication in patients with glaucoma or ocular hypertension.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: To compare the 2% ibopamine provocative test with the water drinking test as a provocative test for glaucoma. METHODS: Primary open-angle glaucoma patients and normal individuals were selected from CEROF-Universidade Federal de Goiânia UFG, and underwent the 2% ibopamine provocative test and the water drinking test in a randomized fashion, at least 1 week apart. Intraocular pressure (IOP) before and after both tests, Bland-Altman graph, sensitivity and specificity (as mesured by ROC curves) were obtained for both methods. RESULTS: Forty-seven eyes from 25 patients were included (27 eyes from 15 glaucoma patients and 20 eyes from 10 normal individuals), with a mean age of 54.2 ± 12.7 years. The mean MD of glaucoma patients was -2.8 ± 2.11 dB. There was no statistically difference in the baseline IOP (p=0.8) comparing glaucoma patients, but positive after the provocative tests (p=0.03), and in the IOP variation (4.4 ± 1.3 mmHg for ibopamine and 3.2 ± 2.2 mmHg for water drinking test, p=0.01). There was no difference in all studied parameters for normal individuals. The Bland-Altman graph showed high dispersion comparing both methods. The areas under the ROC curve were 0.987 for the ibopamine provocative test, and 0.807 for the water-drinking test. CONCLUSION: In this selected subgroup of glaucoma patients with early visual field defect, the ibopamine provocative test has shown better sensitivity/specificity than the water drinking test.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: To evaluate the sensitivity and specificity of machine learning classifiers (MLCs) for glaucoma diagnosis using Spectral Domain OCT (SD-OCT) and standard automated perimetry (SAP). METHODS: Observational cross-sectional study. Sixty two glaucoma patients and 48 healthy individuals were included. All patients underwent a complete ophthalmologic examination, achromatic standard automated perimetry (SAP) and retinal nerve fiber layer (RNFL) imaging with SD-OCT (Cirrus HD-OCT; Carl Zeiss Meditec Inc., Dublin, California). Receiver operating characteristic (ROC) curves were obtained for all SD-OCT parameters and global indices of SAP. Subsequently, the following MLCs were tested using parameters from the SD-OCT and SAP: Bagging (BAG), Naive-Bayes (NB), Multilayer Perceptron (MLP), Radial Basis Function (RBF), Random Forest (RAN), Ensemble Selection (ENS), Classification Tree (CTREE), Ada Boost M1(ADA),Support Vector Machine Linear (SVML) and Support Vector Machine Gaussian (SVMG). Areas under the receiver operating characteristic curves (aROC) obtained for isolated SAP and OCT parameters were compared with MLCs using OCT+SAP data. RESULTS: Combining OCT and SAP data, MLCs' aROCs varied from 0.777(CTREE) to 0.946 (RAN).The best OCT+SAP aROC obtained with RAN (0.946) was significantly larger the best single OCT parameter (p<0.05), but was not significantly different from the aROC obtained with the best single SAP parameter (p=0.19). CONCLUSION: Machine learning classifiers trained on OCT and SAP data can successfully discriminate between healthy and glaucomatous eyes. The combination of OCT and SAP measurements improved the diagnostic accuracy compared with OCT data alone.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Universidade Estadual de Campinas . Faculdade de Educação Física

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Universidade Estadual de Campinas . Faculdade de Educação Física

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Universidade Estadual de Campinas . Faculdade de Educação Física

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Este estudo objetivou caracterizar a presença de pneumócitos tipo II e o início da produção de lipoproteína surfactante em bovinos, correlacionando a idade gestacional com a síntese de surfactante durante o desenvolvimento fetal. Pulmões de fetos com quatro meses de idade gestacional estavam na fase canalicular de desenvolvimento, sem a presença de pneumócitos tipo II ou bandas eletroforéticas compatíveis com a presença de proteínas surfactante. No 5° mês gestacional, os pulmões dos fetos encontravam-se em fase de saculação terminal, com a presença de alvéolos por epitélio cúbico, com áreas formadas por pneumócitos I e II. Nesse período ainda não foi possível identificar proteína surfactante nos pulmões. Esses órgãos em fetos com seis meses de idade gestacional estavam em fase de saco terminal, com presença de pneumócitos tipo I e II. Nessa fase a análise para determinação protéica do surfactante de feto bovino (SDS - PAGE) demonstrou presença de bandas entre 26 e 36kDa, confirmando produção de SP - A, proteína surfactante encontrada em maior quantidade. A partir do 7° mês gestacional, a fase de saco terminal é mais evidente e complexa, com desenvolvimento de intensa vascularização. O pneumócito tipo I apresentava aspecto mais pavimentoso, e o tipo II apresentava aspecto mais globoso. Na análise SDS - PAGE do lavado bronco - alveolar, bandas de proteína surfactante com aspecto similar ao de animais recém-nascidos foram encontradas. Em recém-nascidos, pulmões na fase alveolar foram observados com pneumócitos tipo I e II característicos. O perfil das bandas do lavado bronco-alveolar dos recém-nascidos foi igual ao de animais adultos. Esses achados sugerem que um animal nascido precocemente, a partir dos sete meses de gestação, teria sua sobrevivência garantida devido a uma possível funcionalidade do sistema respiratório do feto, pois o pulmão possuiria as características necessárias para a síntese de proteínas surfactantes. Entretanto, mais estudos clínicos sobre a funcionalidade do sistema respiratório abrem novas fronteiras de experimentos sobre fisiologia respiratória em recém-nascidos bovinos.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A modelagem da estrutura de dependência espacial pela abordagem da geoestatística é fundamental para a definição de parâmetros que definem esta estrutura, e que são utilizados na interpolação de valores em locais não amostrados pela técnica de krigagem. Entretanto, a estimação de parâmetros pode ser muito afetada pela presença de observações atípicas nos dados amostrados. O desenvolvimento deste trabalho teve por objetivo utilizar técnicas de diagnóstico de influência local em modelos espaciais lineares gaussianos, utilizados em geoestatística, para avaliar a sensibilidade dos estimadores de máxima verossimilhança e máxima verossimilhança restrita na presença de dados discrepantes. Estudos com dados experimentais mostraram que tanto a presença de valores atípicos como de valores considerados influentes, pela análise de diagnóstico, pode exercer forte influência nos mapas temáticos, alterando, assim, a estrutura de dependência espacial. As aplicações de técnicas de diagnóstico de influência local devem fazer parte de toda análise geoestatística a fim de garantir que as informações contidas nos mapas temáticos tenham maior qualidade e possam ser utilizadas com maior segurança pelo agricultor.