968 resultados para Detection of Partially Occluded Objects


Relevância:

100.00% 100.00%

Publicador:

Resumo:

SUMMARY Human Adenoviruses (HAdV) are notably resistant in the environment. These agents may serve as effective indicators of fecal contamination, and may act as causative agents of a number of different diseases in human beings. Conventional polymerase chain reaction (PCR) and, more recently, quantitative PCR (qPCR) are widely used for detection of viral agents in environmental matrices. In the present study PCR and SYBR(r)Green qPCR assays were compared for detection of HAdV in water (55) and sediments (20) samples of spring and artesian wells, ponds and streams, collected from dairy farms. By the quantitative methodology HAdV were detected in 87.3% of the water samples and 80% of the sediments, while by the conventional PCR 47.3% and 35% were detected in water samples and sediments, respectively.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

SUMMARY Leishmania infantum causes visceral leishmaniasis (VL) in the New World. The diagnosis of VL is confirmed by parasitological and serological tests, which are not always sensitive or specific. Our aim was to design new primers to perform a Polymerase Chain Reaction (PCR) for detecting L. infantum. Sequences of the minicircle kinetoplast DNA (kDNA) were obtained from GenBank, and the FLC2/RLC2 primers were designed. Samples of DNA from L. infantum, Leishmania amazonensis, Leishmania braziliensis, Leishmania guyanensis, Leishmania naiffi, Leishmania lainsoni, Leishmania panamensis, Leishmania major and Trypanosoma cruzi were used to standardize the PCR. PCR with FLC2/RLC2 primers amplified a fragment of 230 bp and the detection limit was 0.2 fg of L. infantum DNA. Of the parasite species assayed, only L. infantum DNA was amplified. After sequencing, the fragment was aligned to GenBank sequences, and showed (99%) homology with L. infantum. In the analysis of blood samples and lesion biopsy from a dog clinically suspected to have VL, the PCR detected DNA from L. infantum. In biopsy lesions from humans and dogs with cutaneous leishmaniasis, the PCR was negative. The PCR with FLC2/RLC2 primers showed high sensitivity and specificity, and constitutes a promising technique for the diagnosis of VL.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Nonhuman primates are considered as the natural hosts of Hepatitis A virus (HAV), as well as other pathogens, and can serve as natural sentinels to investigate epizootics and endemic diseases that are of public health importance. During this study, blood samples were collected from 112 Neotropical primates (NTPs) (Sapajus nigritus and S. cay, n = 75; Alouatta caraya, n = 37) trap-captured at the Paraná River basin, Brazil, located between the States of Paraná and Mato Grosso do Sul. Anti-HAV IgG antibodies were detected in 4.5% (5/112) of NTPs, specifically in 6.7% (5/75) of Sapajus spp. and 0% (0/37) of A. caraya. In addition, all samples were negative for the presence of IgM anti-HAV antibodies. These results suggest that free-ranging NTPs were exposed to HAV within the geographical regions evaluated.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Dissertação para obtenção do Grau de Doutor em Nanotecnologias e Nanociências

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Four methods for detecting household infestations with Panstrongylus megistus were compared: 1) manual collection; 2) collection after pyrethrum application; 3) search viable eggs; and 4) Gomez-Nuñez boxes. Manual collection was the most sensitive method (23% infested), followed by pyrethrum (21%), Gomez-Nuñez boxes (15%) and viable eggs (12%). About 10% of infested houses were positive exclusively on the Gomez-Nuñez box test. More over, 6 out of the 7 houses positive exclusively on the Gomez-Nuñez method were located in a recently sprayed area, where P. megistus density was low. Inspection of Gomez-Nuñez boxes at 12 weekspost-application was twice as effective as inspection at 6 weekspost-application. Triatomine feces was the most common evidencefor thepresence of P. megistus found within Gomez-Nuñez boxes. Gomez-Nuñez boxes area a useful adjunct to manual collection in detecting domestic infestations with P. megistus, especially in areas where bug densities are low. However, the utility of Gomez-Nuhez boxes must be weighed against the time and labor they require.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Two competitive enzyme immunoassays (EIA) techniques were developed: in the first (COMP-1), test sera were added together with HAV antigen on anti-HAV IgG-coated wells followed by an anti-HA VHRP conjugate; in the second (COMP-2), test sera and anti-HA VHRP conjugate competed for HAV epitopes previously adsorbed to anti-HA V IgG-coated wells. Both procedures used tetramethylbenzidine (TMB) as a substrate. Both competitive tests were shown to be reproducible and suitable for routine diagnosis and research purposes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Dissertação para obtenção do Grau de Mestre em Genética Molecular e Biomedicina

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The human lymphotropic viruses type I (HTLV-I) and type II (HTLV-II) are members of a group of mammalian retroviruses with similar biological properties, and blood transfusion is an important route of transmission. HTLV-I is endemic in a number of different geographical areas and is associated with several clinical disorders. HTLV-II is endemic in several Indian groups of the Americas and intravenous drug abusers in North and South America, Europe and Southeast Asia. During the year of 1995, all blood donors tested positive to HTLV-I/II in the State Blood Bank (HEMOPA), were directed to a physician and to the Virus Laboratory at the Universidade Federal do Pará for counselling and laboratory diagnosis confirmation. Thirty-five sera were tested by an enzyme immune assay, and a Western blot that discriminates HTLV-I and HTLV-II infection. Two HTLV-II positive samples were submitted to PCR analysis of pX and env genomic region, and confirmed to be of subtype IIa. This is the first detection in Belém of the presence of HTLV-IIa infection among blood donors. This result emphasizes that HTLV-II is also present in urban areas of the Amazon region of Brazil and highlights the need to include screening tests that are capable to detect antibodies for both types of HTLV.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In the present report we describe the results from a pilot study aimed at detecting enterovirus sequence in cardiac tissues, obtained through endomyocardial biopsies, from patients suffering from cardiac diseases in the Amazon region. Six samples that were collected from three patients were analysed by RT-PCR showing 3 positive and 3 negative results. These preliminary findings suggest the participation of enteroviruses in the etiology of cardiac diseases, mainly myocarditis, and warrant further and broader local studies on this subject.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Peripheral blood leukocytes from different animals were isolated from whole blood and maintained in Dulbeco's medium containing homologous serum without antibiotics. After 72 hrs microscopic examination of these cells showed that most animals were infected with Ehrlichia. Observation of thin blood smears from the same animals showed that only two were positive for Ehrlichia. The results of this investigation show that leukocyte culture is superior to the traditional thin blood film method in the detection of Ehrlichia and that asymptomatic carriers are easily detected. The method is inexpensive and does not require specific cell lines although it is necessary to use sterile sera.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

To evaluate the sensitivity of polymerase chain reaction (PCR) to reveal known number of trypomastigote in the blood of mice, three separate experiments were done. First: To eight samples of 500mul of normal mice blood, one aliquot of 1, 2, 3, 4, 5, 10, and 50 trypomastigotes respectively, were added. Second and third: 10 aliquots with 1 and 10 with 2 trypomastigotes were added to samples of 500mul of normal mice blood. Positive control: 500mul of blood containing 100,000 trypomastigotes. For kDNA minicircles amplification by PCR the primers:S35 and S36 were used. PCR revealed products of 330 b.p in the positive controls. When only one sample with the aliquots of 1 or 2 trypomastigotes was examined, results were negative; results were positive with aliquots of 3 to 50 trypomastigotes. In the 2nd and 3rd experiments, 9/10 aliquots with one parasite and 9/10 with 2 trypomastigotes were positive revealing a high sensitivity of this reaction. In conclusion, the presence of one single parasite in 500mul of blood, is enough for a positive PCR. This method could be used as a complement to the various parasitological cure tests in treated mice, when low volumes of blood are individually examined.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In the present study PCR was applied to detect leptospires in human urine. Several approaches for sample processing were evaluated to optimize the detection of leptospires in urine mixed with this bacterium. Furthermore, some changes in the composition of the reaction mix were studied. No amplification was observed in acidic urine, therefore neutralization of the sample immediately after collection is strongly recommended. PBS gave better results than Tris or NaOH as neutralizing reagents. Freezing and thawing of samples before processing yielded negative results. Elimination of epithelial cells, leukocytes and crystals by centrifugation at 3,000 rpm at room temperature increased sensitivity. In addition, both the washing step after collecting leptospires by centrifugation and the inclusion of 0.1% bovine serum albumin in the reaction mix minimized the interference of other inhibitory compounds. These modifications were useful to improve the detection of Leptospira in urine by PCR.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A ligase chain reaction DNA amplification method for direct detection of Mycobacterium tuberculosis (Abbott LCx MTB) in respiratory specimens was evaluated. Results from LCx MTB Assay were compared with those from acid fast bacilli smear, culture, and final clinical diagnosis for each patient. A total of 297 respiratory specimens (sputum and bronchial lavage) from 193 patients were tested. The sensitivity, specificity, positive predictive value and negative predictive value of LCx vs culture were 92.7%, 93%, 67.8% and 98.7%, respectively. When compared to the clinical final diagnosis, the sensitivity, specificity, PPV and NPV for LCx were 88.9%, 96.8%, 86.5% and 97.4%, respectively. The sensitivity of LCx MTB assay was 75% for smear-negative, culture positive samples. The results indicate that LCx MTB assay is a rapid, simple and valuable technique as a complementary tool for the diagnosis of tuberculosis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Mycobaterium leprae infection was investigated in armadillos from the State of Espírito Santo, Brazil. The ML Flow test was performed on 37 nine-banded armadillos and positive results were found in 11 (29.7%). The ML Flow test may be used to identify possible sources of Mycobaterium leprae among wild armadillos.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Breast cancer is the most common type of cancer worldwide. The effectiveness of its treatment depends on early stage detection, as well as on the accuracy of its diagnosis. Recently, diagnosis techniques have been submitted to relevant breakthroughs with the upcoming of Magnetic Resonance Imaging, Ultrasound Sonograms and Positron Emission Tomography (PET) scans, among others. The work presented here is focused on studying the application of a PET system to a Positron Emission Mammography (PEM) system. A PET/PEM system works under the principle that a scintillating crystal will detect a gamma-ray pulse, originated at the cancerous cells, converting it into a correspondent visible light pulse. The latter must then be converted into an electrical current pulse by means of a Photo- -Sensitive Device (PSD). After the PSD there must be a Transimpedance Amplifier (TIA) in order to convert the current pulse into a suitable output voltage, in a time period lower than 40 ns. In this Thesis, the PSD considered is a Silicon Photo-Multiplier (SiPM). The usage of this recently developed type of PSD is impracticable with the conventional TIA topologies, as it will be proven. Therefore, the usage of the Regulated Common-Gate (RCG) topology will be studied in the design of the amplifier. There will be also presented two RCG variations, comprising a noise response improvement and differential operation of the circuit. The mentioned topology will also be tested in a Radio-Frequency front-end, showing the versatility of the RCG. A study comprising a low-voltage self-biasing feedback TIA will also be shown. The proposed circuits will be simulated with standard CMOS technology (UMC 130 nm), using a 1.2 V power supply. A power consumption of 0.34 mW with a signal-to-noise ratio of 43 dB was achieved.