686 resultados para Denture Rebasing


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objectives: The objective of this study was to evaluate the accuracy and reproducibility of three complete denture biofilm indices (Prosthesis Hygiene Index; Jeganathan et al. Index; Budtz-J circle divide rgensen Index) by means of a computerised comparison method. Background: Clinical studies into denture hygiene have employed a large number of biofilm indices among their outcome variables. However, the knowledge about the validity of these indices is still scarce. Materials and methods: Sixty-two complete denture wearers were selected. The internal surfaces of the upper complete dentures were stained (5% erythrosine) and photographed. The slides were projected on paper, and the biofilm indices were applied over the photos by means of a scoring method. For the computerised method, the areas (total and biofilm-covered) were measured by dedicated software (Image Tool). In addition, to compare the results of the computerised method and Prosthetic Hygiene Index, a new scoring scale (including four and five graded) was introduced. For the Jeganathan et al. and Budtz-J circle divide rgensen indices, the original scales were used. Values for each index were compared with the computerised method by the Friedman test. Their reproducibility was measured by means of weighed kappa. Significance for both tests was set at 0.05. Results: The indices tested provided similar mean measures but they tended to overestimate biofilm coverage when compared with the computerised method (p < 0.001). Agreement between the Prosthesis Hygiene Index and the computerised method was not significant, regardless of the scale used. Jeghanathan et al. Index showed weak agreement, and consistent results were found for Budtz-Jorgensen Index (kappa = 0.19 and 0.39 respectively). Conclusion: Assessment of accuracy for the biofilm indices showed instrument bias that was similar among the tested methods. Weak inter-instrument reproducibility was found for the indices, except for the Budtz-J circle divide rgensen Index. This should be the method of choice for clinical studies when more sophisticated approaches are not possible.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: The aim of this study was to evaluate the effect of three denture hygiene methods against different microbial biofilms formed on acrylic resin specimens. Materials and methods: The set (sterile stainless steel basket and specimens) was contaminated (37 degrees C for 48 hours) by a microbial inoculum with 106 colony-forming units (CFU)/ml (standard strains: Staphylococcus aureus, Streptococcus mutans, Escherichia coli, Candida albicans, Pseudomonas aeruginosa, and Enterococcus faecalis; field strains: S. mutans, C. albicans, C. glabrata, and C. tropicalis). After inoculation, specimens were cleansed by the following methods: (1) chemical: immersion in an alkaline peroxide solution (Bonyplus tablets) for 5 minutes; (2) mechanical: brushing with a dentifrice for removable prostheses (Dentu Creme) for 20 seconds; and (3) a combination of chemical and mechanical methods. Specimens were applied onto a Petri plate with appropriate culture medium for 10 minutes. Afterward, the specimens were removed and the plates incubated at 37 degrees C for 48 hours. Results: Chemical, mechanical, and combination methods showed no significant difference in the reduction of CFU for S. aureus, S. mutans (ATCC and field strain), and P. aeruginosa. Mechanical and combination methods were similar and more effective than the chemical method for E. faecalis, C. albicans (ATCC and field strain), and C. glabrata. The combination method was better than the chemical method for E. coli and C. tropicalis, and the mechanical method showed intermediate results. Conclusion: The three denture hygiene methods showed different effects depending on the type of microbial biofilms formed on acrylic base resin specimens.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

P>The use of seven domains for the Oral Health Impact Profile (OHIP)-EDENT was not supported for its Brazilian version, making data interpretation in clinical settings difficult. Thus, the aim of this study was to assess patients` responses for the translated OHIP-EDENT in a group of edentulous subjects and to develop factor scales for application in future studies. Data from 103 conventional and implant-retained complete denture wearers (36 men, mean age of 69 center dot 1 +/- 10 center dot 3 years) were assessed using the Brazilian version of the OHIP-EDENT. Oral health-related quality of life domains were identified by factor analysis using principal component analysis as the extraction method, followed by varimax rotation. Factor analysis identified four factors that accounted for 63% of the 19 items total variance, named masticatory discomfort and disability (four items), psychological discomfort and disability (five items), social disability (five items) and oral pain and discomfort (five items). Four factors/domains of the Brazilian OHIP-EDENT version represent patient-important aspects of oral health-related quality of life.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objectives: To examine whether denture use and recurrent sores caused by ill-fitting dentures are associated with intra-oral squamous cell carcinoma (IO-SCC) in individuals exposed to tobacco. Methods: We conducted a hospital-based case-control study. The study population comprised 124 patients with IO-SCC and the same number of controls (individually paired according to gender and age) recruited from outpatient units of the same hospital. Conditional logistic regression analysis assessed the effect of denture use and recurrent oral sores by ill-fitting dentures, adjusted by covariates on the lifetime exposure to alcohol and tobacco, socioeconomic standings, and dietary patterns. Results: The use of dentures showed no association with IO-SCC [adjusted odds ratio (OR) 1.40, 95 percent confidence interval 0.51-3.87, P = 0.513] in an assessment controlled by socioeconomic position, lifetime exposure to alcohol and tobacco, and dietary patterns. However, the report of recurrent sores caused by ill-fitting dentures showed significant association with the disease (adjusted OR 4.58, 95 percent confidence interval 1.52-13.76, P = 0.007). Conclusions: The association between recurrent oral sores caused by ill-fitting dentures and squamous cell carcinoma of the mouth in smokers is in agreement with the hypothesis that the chronic physical irritation of oral mucosa contributes to the topical carcinogenic effect of tobacco, which must be taken into careful consideration in the planning of dental services for adults and the elderly.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

P>Although photodynamic therapy (PDT) has shown great promise for the inactivation of Candida species, its effectiveness against azole-resistant pathogens remains poorly documented. This in vitro study describes the association of Photogem (R) (Photogem, Moscow, Russia) with LED (light emitting diode) light for the photoinactivation of fluconazole-resistant (FR) and American Type Culture Collection (ATCC) strains of Candida albicans and Candida glabrata. Suspensions of each Candida strain were treated with five Photogem (R) concentrations and exposed to four LED light fluences (14, 24, 34 or 50 min of illumination). After incubation (48 h at 37 degrees C), colonies were counted (CFU ml-1). Single-species biofilms were generated on cellulose membrane filters, treated with 25.0 mg l-1 of Photogem (R) and illuminated at 37.5 J cm-2. The biofilms were then disrupted and the viable yeast cells present were determined. Planktonic suspensions of FR strains were effectively killed after PDT. It was observed that the fungicidal effect of PDT was strain-dependent. Significant decreases in biofilm viability were observed for three strains of C. albicans and for two strains of C. glabrata. The results of this investigation demonstrated that although PDT was effective against Candida species, fluconazole-resistant strains showed reduced sensitivity to PDT. Moreover, single-species biofilms were less susceptible to PDT than their planktonic counterparts.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In order to consider the photodynamic therapy (PDT) as a clinical treatment for candidosis, it is necessary to know its cytotoxic effect on normal cells and tissues. Therefore, this study evaluated the toxicity of PDT with PhotogemA (R) associated with red light-emitting diode (LED) on L929 and MDPC-23 cell cultures and healthy rat palatal mucosa. In the in vitro experiment, the cells (30000 cells/cm(2)) were seeded in 24-well plates for 48 h, incubated with PhotogemA (R) (50, 100, or 150 mg/l) and either irradiated or not with a red LED source (630 +/- 3 nm; 75 or 100 J/cm(2); 22 mW/cm(2)). Cell metabolism was evaluated by the MTT assay (ANOVA and Dunnet`s post hoc tests; p < 0.05) and cell morphology was examined by scanning electron microscopy. In the in vivo evaluation, PhotogemA (R) (500 mg/l) was applied to the palatal mucosa of Wistar rats during 30 min and exposed to red LED (630 nm) during 20 min (306 J/cm(2)). The palatal mucosa was photographed for macroscopic analysis at 0, 1, 3, and 7 days posttreatment and subjected to histological analysis after sacrifice of the rats. For both cell lines, there was a statistically significant decrease of the mitochondrial activity (90-97%) for all PhotogemA (R) concentrations associated with red LED regardless of the energy density. However, in the in vivo evaluation, the PDT-treated groups presented intact mucosa with normal characteristics both macroscopically and histologically. From these results, it may be concluded that the association of PhotogemA (R) and red LED caused severe toxic effects on normal cell cultures, characterized by the reduction of mitochondrial activity and morphological alterations, but did not cause damage to the rat palatal mucosa in vivo.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The cobalt-chromium alloy is extensively used in the Odontology for the confection of metallic scaffolding in partial removable denture. During the last few years, it has been reported an increasing number of premature imperfections, with a few months of prosthesis use. The manufacture of these components is made in prosthetic laboratories and normally involves recasting, using parts of casting alloy and parts of virgin alloy. Therefore, the objective of the present study was to analyze the mechanical properties of a commercial cobalt-chromium alloy of odontological use after successive recasting, searching information to guide the dental prosthesis laboratories in the correct manipulation of the cobalt-chromium alloy in the process of casting and the possible limits of recasting in the mechanical properties of this material. Seven sample groups were confectioned, each one containing five test bodies, divided in the following way: G1: casting only with virgin alloy; G2: casting with 50% of the alloy of the G1 + 50% of virgin alloy; G3: casting with 50% of the alloy of the G2 + 50% of virgin alloy; G4: casting with 50% of the alloy of the G3 + 50% of virgin alloy; G5: 50% of alloy of the G4 + 50% of virgin alloy; G6: 50% of alloy of the G5 + 50% of virgin alloy and finally the G7, only with recasting alloy. The modifications in the mechanical behavior of the alloy were evaluated. Moreover, it was carried the micro structural characterization of the material by optic and electronic scanning microscopy, and X ray diffraction.and fluorescence looking into the correlatation of the mechanical alterations with structural modifications of the material caused by successive recasting process. Generally the results showed alterations in the fracture energy of the alloy after successive recasting, resulting mainly of the increasing presence of pores and large voids, characteristic of the casting material. Thus, the interpretation of the results showed that the material did not reveal significant differences with respect to the tensile strength or elastic limit, as a function of successive recasting. The elastic modulus increased from the third recasting cycle on, indicating that the material can be recast only twice. The fracture energy of the material decreased, as the number of recasting cycles increased. With respect to the microhardness, the statistical analyses showedno significant differences. Electronic scanning microscopy revealed the presence of imperfections and defects, resulting of the recasting process. X ray diffraction and fluorescence did not show alterations in the composition of the alloy or the formation of crystalline phases between the analyzed groups. The optical micrographs showed an increasing number of voids and porosity as the material was recast. Therefore, the general conclusion of this study is that the successive recasting of of Co-Cr alloys affects the mechanical properties of the material, consequently leading to the failure of the prosthetic work. Based on the results, the best recommendadition is that the use of the material should be limited to two recasting cycles

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The non-adaptation of the removable partial prosthesis (RPP) base to fibromucosal tissue is caused by resorption of residual ridges (RRR). The onset of bone resorption, which occurs after tooth extraction and continues throughout life, is accelerated by local or systemic factors. Aim: Assess the degree of non-adaptation of removable partial prosthesis saddles and the factors that influence it. Methodology: A sectional study was conducted with 81 patients using RPP who had their prostheses installed between 2003 and 2007 (1 to 5 years of use) at the Faculty of Dentistry of the Universidade Federal do Rio Grande do Norte (UFRN). After anamnese and clinical examination, a cast was made with polyether-based material, using the base of the prosthesis to make the impression. The base of the saddle was loaded with the casting material and positioned in the mouth, applying pressure on the supports. After polymerization, the material was removed from the saddle and measurements were taken at 3 different points using a pachymeter. Results: The non-adaptation of the saddle increased significantly with years of use (p = 0.005). The tooth-tissue supported prostheses obtained higher mean non-adaptation values than those of tooth supported prostheses (p < 0.001). Flaccid mucosa showed the worst non-adaptation results, which were statistically different from resilient mucosa (p < 0.001). The greater the extension of the saddle, the greater the non-adaptation (p < 0.001). The natural tooth antagonistic arch yielded better results than did RPP and total prosthesis (p < 0.001). Saddle non-adaptation at the free end was less near the pillar tooth and greater in the more posterior region (p < 0.001). When adaptation of the supports to the niches was poor, greater saddle non-adaptation occurred than when it was good or fair (p < 0.001). Saddles located in the posterior region of the arch had greater non-adaptation than those in the anterior region (p = 0.023). Conclusion: The mean non-adaptation of the saddle to the residual ridges was 0.27 mm. It can be concluded that, even with the use of RPP, bone height reduction was slight within the 1-5-year period of use. The following are factors that influence adaptation of the RPP saddle base: years of use, age, force transmission path to the alveolar bone, location of the toothless area, antagonistic arch, type of mucosa, adaptation of supports to the niche and extension of the saddle

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The maintenance of masticatory function is especially important for patients who wear complete dentures due to the limitations of this type of prosthesis. Thus, the bilateral balanced occlusion (BBO) is used to achieve, besides other advantages, greater masticatory efficiency. However, analyzing critically the literature, it is observed that there is not enough scientific evidence that support the BBO as the most appropriate occlusal concept in complete dentures. This way, the purpose of the present study was to verify if complete dentures wearers with BBO present better masticatory efficiency and capacity than those with canine guidance (CG). A double-blind controlled crossover clinical trial was conducted. The sample was made of 24 completely edentulous patients. The subjects wore sets of complete dentures with both occlusal concepts for equal periods of 3 months. Objective data were collected through the masticatory efficiency test, performed by the colorimetric method, in which capsules of a synthetic material enclosing fuchsine- containing granules were used. Subjective data were recorded by patient´s ratings of their chewing function, which is the masticatory ability. No significant statistical difference was found for masticatory efficiency (p=0,0952) and masticatory ability (x2=0,5711/ p=0,4498) between the two occlusal concepts studied, as well as there was no correlation between these two variables (p=0,2985). Based on these results, it seems reasonable to use CG for the setup of complete dentures, since it is an easier and quicker technical procedure, until that future researches can come to complement this question

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Aim: To evaluate user satisfaction and quality of prosthetic treatments performed in specialized dental clinics (CEOs) of Natal Metropolitan Region - RN. Methods: Cross-sectional study with subjects who underwent prosthetic CEOs in the cities of Natal, Macaíba, Parnamirim and Sao Goncalo do Amarante in the period 2007 to 2009. Data collection was performed by questionnaire, clinical examination of the oral cavity and examination of fabricated denture. This analysis involved the following aspects: retention, stability, aesthetics and prosthesis fixation. The variables are presented by means of absolute numbers and proportions. The determination of the association between the independent and dependent variables was conducted by the association of Chi-square test and Fisher exact test. Results: A total of 149 users, totaling 233 conventional dentures (148 upper and 85 lower). Most patients (56.4%) were rehabilitated with conventional complete dentures. The technical quality of the denture was regarded as satisfactory in the majority (52.7%), whereas the inferior dentures were rated as unsatisfactory in 90.5% of cases. Satisfaction with the prosthesis was 69.1% (N = 103). The average time to begin treatment was 3 months to receive while the prosthesis was 4 months old. The presence of injury from the upper prosthesis occurred in 21.5% of cases (N = 32), candidiasis being the most frequent (N = 18). The technical quality of the upper prosthesis (p=0,041), as well as retention (p=0,002) and stability (p<0,001) were significantly associated with user satisfaction. Conclusions: The specialized Dental clinics has been fulfilling its role of providing treatment of intermediate complexity for low-income population with the majority of satisfield patients, even when their dentures have problems of technical quality

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Even nowadays there is in Brasil a large number of edentulous and a precarious financial condition of most of the population. In addition, World Health Organization aims for oral health, which consists on the maintenance of a natural dentition, functional and aesthetic composed of at least 20 teeth, without need of prosthetic intervention throughout life. From this and considering the lack of researches about the permanence of edentulous spaces in the oral cavity, and also avoiding overtreatment, this research has been proposed. Thus, the aim was to evaluate the effect of different lengths of the shortened lower dental arch in the presence or absence of a removable partial denture (RPD) on masticatory function, quality of life and occurrence of temporomandibular dysfunction. To achieve this goal, we compared the masticatory efficiency (colorimetric test), the oral comfort through the analysis of the impact of oral health in quality of life (OHIP-14), the presence of temporomandibular dysfunction (RDC/TMD) and the general quality of life (WHOQOL) of patients with shortened dental arches (SDA) (n=60), which is an arch with a reduction of teeth starting posteriorly, and patients with complete dental arch (Complete DA) (n = 34). The group of patients whit SDA was divided among PPR wears (PPD + SDA) (n = 17) and non-wears (n = 43). The population of this study consisted on patients who received or looked for treatment at the clinics of the Department of Dentistry of UFRN, from clinical analysis and records. The sample was chosen by convenience. For statistical analysis, it was a database in SPSS 17.0, followed by descriptive analysis with frequencies, absolute values, tests of central tendency and variability. The statistical tests used were chi-squared and analysis of variance as well as Tukey s post test, when applicable, all with a 95% confidence level. The results shown a prevalence of TMD of 47,1% among patients using PRP and 69,8% among those who didn t, but this result wasn t statistically significant. The mean of the results of masticatory efficiency, WHOQOL and OHIP didn t show association to the presence or absence of PPR and to the lower number of occlusal units of the patients (0, 1, 2 or more occlusal). The association only occurred among the different groups of SDA and the patients with complete dental arch. Taking into account the results, it could be observed that studied patients with low posterior support using lower PRP didn t have better masticatory efficiency, general quality of life, less impacts of their oral conditions in quality of life or not even less temporomandibular dysfunction or better masticatory efficiency when compared to those who didn t use the prosthesis

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The literature has shown a relation between periodontics and the removable partial denture (RPD), with progressive destruction observed in the support structures. The aim of this study was to clinically assess periodontal condition in users of removal partial denture (RPD), and compare right abutments teeth, indirect abutments and controls before installation and after 1 year, in addition to comparing tooth-supported and tooth mucosa-supported abutments. A total of 50 patients, 32 women and 18 men, mean age of 45 years, took part in the study. The patients were examined by a single examiner at prosthesis installation and after 3, 6, 9 and 12 months. The following were verified at each examination: Probe Depth (PD), Plaque Index (PI), Gingival Index (GI), the amount of Keratinized Mucosa (KM), Gingival Recession (GR) and Dental Mobility (DM); in addition patients received oral hygiene orientation, accompanied by prophylaxis, periodontal scaling and root planing (PSRP), when necessary. Analysis of Variance (ANOVA) with Tukey-Kramer post test was used to assess the dependent variables (PD, PI, KM, GR) of the three groups over time while Friedman s test was used for GI. To assess the outcomes of prosthesis type in the right abutment group, a confidence interval-based analysis was performed. The results showed that the control group was the least compromised in all the variables studied. With respect to development of the groups over time, it was verified that the measures for GR, PD, GI and KM increased from initial examination to 1 year of use in all the groups, but only PI showed a significant increase. There was a non-discriminatory low prevalence of dental mobility. The tooth mucosa-supported prosthesis had significantly higher values for GR, GI and PI and significantly lower ones for KM when compared to tooth-supported. Over time, both types of prostheses showed no significant differences from initial to final examination for the variables GR, PD, KM and GI, with PI significant only for tooth-supported. The results showed that the teeth most involved in RPD design had greater potential of periodontal damage, probably because of greater dental biofilm accumulation. Abutments elements adjacent to the free extremities had less favorable periodontal condition than those adjacent to interpolated spaces, but the use of RPD did not worsen the initial condition

Relevância:

10.00% 10.00%

Publicador:

Resumo:

There is a lack of clinical studies evaluating techniques of functional impression for partially edentulous arches. The aim of this double-blind non-randomized controlled clinical trial was to compare the efficacy of altered cast impression (ACI) and direct functional impression (DFI) techniques. The efficacy was evaluated regarding the number of occlusal units on denture teeth, mucosa integrity at 24-hour follow-up and denture base extension. The sample included 51 patients (female and male) with mean age of 58.96 years treated at Dental Department of UFRN. The patients, exhibiting edentulous maxilla and mandibular Kennedy class I, were divided into two groups (group ACI, n=29; group DFI, n=22). Clinical evaluation was based on the number of occlusal units on natural and/or artificial teeth, mucosa integrity at 24-hour follow-up, and denture base extension. Statistical analysis was conducted using the software SPSS 17.0® (SPSS Inc., Chicago, Illinois). Student T-test was used to reveal association between number of occlusal units and impression technique while chi-square test showed association between mucosa integrity and impression technique. Fischer s exact test was applied for association between denture base extension and impression technique at 95% level of significance. No significant difference was observed between the groups regarding number of occlusal units, mucosa integrity and denture base extension. The altered cast technique did not provide significant improvement in comparison to the direct technique when the number of occlusal units, mucosa integrity and denture base extension

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Edentulous patients with complaint about mandibular conventional denture might experience poor masticatory function and negative impact of oral health on quality of life. The aim of this controlled clinical trial was to evaluate the effect of mandibular overdenture on oral health-related quality of life and masticatory efficacy in patients wearing mandibular complete dentures. The edentulous patients (n=16) were rehabilitated with new maxillary and mandibular complete dentures and, after 3 months, mandibular overdentures retained by 2 implants (bar-clip system) were fabricated. The Brazilian version of OHIP-Edent questionnaire was used to assess the oral healthrelated quality of life. Masticatory efficacy was evaluated through a colorimetric method with chewing capsules. The mean OHIP-Edent score was 8.5 with conventional dentures and 2.0 with mandibular overdenture, which means a positive impact of oral health on quality of life with overdentures (p=0.001). The mean absorbance for masticatory efficacy was 0.025 for conventional dentures and 0.073 for overdentures. There was statistically significant difference for masticatory efficacy before and after implants rehabilitation (p=0.003). However, there was no correlation between masticatory efficacy and OHIP (p>0.05). So, mandibular overdenture retained by 2 implants improved the quality of life and masticatory efficacy of edentulous patients with complaint about mandibular conventional complete dentures

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Aim: To determine the frequency and type of complications related to removable partial denture (RPD) less, Kennedy Class I, over time . Materials and Methods: This observational study consisted of a sample of 65 users PPR lower arches in Kennedy Class I and dentures, rehabilitated in the Department of Dentistry, Federal University of Rio Grande do Norte (UFRN). Patients were followed through periodic controls during periods of 60 days, 6 months and 1 year from installation. After the first year of control had other returns annually. The occurrence of complications or prosthetic failure was observed and recorded in a specific clinical record over 39 months. The patterns of failures observed were classified in the following situations: occurrence of traumatic ulcers after 2 months of installation, lack of retention, fracture or caries in the rest, fracture or dislocation of the artificial teeth, the larger connector fracture, fracture clip fracture support, poor support (need to reline the denture) and prosthesis fracture. Results: The incidence of complications was low frequency, being higher in the second year of use of the prosthesis. Among the complications that occurred more is the loss of retention (31.57%). Failures more severe and difficult to solve as the fracture elements of the metal structure of the PPR had low occurrence and were represented by only one case of the larger connector (5.3%) fractures. Conclusion: Removable partial dentures mandibular free end opposing of the conventional dentures have a low complication rate after 39 months of use when subjected to periodic controls